| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC accepted | |
| 2 | L2₹9.5 L+₹79,064.06 (9.05%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹9.6 L+₹88,619.06 (10.1%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical technically not qualified |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
3 Jan 2022, 12:00 pmClosed
Executive_Engineer_PWD_Hooghly_Electrical_Division
Executive_Engineer_PWD_Hooghly_Electrical_Division
Electrical installation work in respect of providing new service connection for fire fighting load as well as strengthening of existing 2 nos. LT Services at Uttarpara State General Hospital, Uttarpara, Hooghly
2021_WBPWD_357484_1
WBPWD/EE/HED/NIeT-17/2021-22
Open Tender
Electrical Work/ Equipment
Item Rate
25 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹17,000
HOOGHLY ELECTRICAL DIVISION
5 May 2022
23 Dec 2021
5 Jan 2022
23 Dec 2021
3 Jan 2022
23 Dec 2021
28 Dec 2021
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
8 Mtr [4(c)/ E-25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switch as per GS.
On Board [ 3 (i) / E- 20 ]
4.5 mtr. [ 3 (iv) / E- 20 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
25 mm size [ 7(b)/ E- 16 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
25mm dia 3 mm thick [ 7 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(6 sqmm)+1 x (4 sqmm) [ 1(v) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,13(c)]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC.
4 Way ( Up to 160 A ) Make - Legrand, Enclosure 607913/Siemens-Enclosure-8GB31571RC)/Schneider-Enclosure-A9HVD04M/L&T Enclosure- (LTVD04MGN) as approved by E.I.C] [15 / D- 11 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand / Schneider/L&T/Siemens as per direction of EIC.].
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make NICCO/ Gloster/KEI/Havells as approved by E.I.C]
2 Core 10 Sq.mm
4 Core 50 Sqmm
3.5 Core 95 Sq. mm
3.5 Core 120 Sqmm
3.5 Core 185 Sqmm
Laying of cable in underground trench as per GS for the following numbers of Cables.
Above 35 and upto 185 Sq. mm [ 1(b)/ F- 2 ]
Laying of one cable through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand
Upto 150 Sq. mm [ 4(a)/ F- 3 ]
above 150 sqmm and upto 300 sqmm [ 4(b)/ F- 3 ]
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting[2(c)/F-1]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [2(e)/F-1]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
Above 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc [5(iii)/F-3]
,Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
40mm dia [11(c)/F-6]
50mm dia [11(d)/F-6]
80mm dia [11(f)/F-6]
100mm dia [11(g)/F-6]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4/3.5)Core as per GS.
2 Core 10 Sq.mm [ 7(a)/F4 & 8(b- iii) /F5]
4Core 50 Sq. mm [7(c)/F4 & 8(b- xvi) /F5]
3.5Core 95 Sq. mm [ 7(d)/F4 & 8(b- xviii) /F5]
3.5Core 120 Sq. mm [ 7(d)/F4 & 8(b- xix) /F5]
3.5Core 185 Sq. mm [ 7(d)/F4 & 8(b- xxi) /F5]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall as per GS.( Make - L&T/Havells/Siemens).
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall (240V DP with fuse on L&N) (Make- Havells/HPL)
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)
4 bars (415 V, 315 A) Dimension of Cu bars [85mm long](4 x 40x5mm) Dimension of Sheet Metal Box (500x150mm) [ D-12/19(b)]
Supply & Fixing Modular type 240 V, 16A, 3 pin plug socket with separate 16 A Modular type switch on sheet metal switch board embedded in wall as per GS. [Legrand-Model Arteror/Myrius or equivalent model of Crabtree/ Schneider) [ 9(b) / E-18]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket ([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/ Schneider) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 9(a) / E-18]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Twin fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3242 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 2 no. 18W Master LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 1 no. 18W Master LED Tube
Fixing only single/twin LED batten light fitting suspended from the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Supply of ceiling fans with brust proof P2/S3 Capacitor complete with all accessories without regulator(Make-Usha- Striker or equivalent model of CG/Orient)
a. 1200 mm Sweep
Supply & fixing heavy duty Exhaust fan(Make-EPC] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust incl. s&f louver shutter as per G.S. )
12"( 300mm ) Speed 920 RPM
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS
S & F of 240V, 50Hz Analog Time Switch (Make- L&T GIC, Cat No. J648B1 or equivalent model of Havells/Hager) on existing MCB SS enclosure and making necessary connection with exhaust fan including time setting as per direction of EIC.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification as per GS. [ 29/D-14 ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) ([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/ Schneider) ) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Engraving the deptt. number with 10 mm lettering on the body as per GS. [ 24 (a) / C-3 ]
Extra for additional one letter incl. hifen, stroke and stop [24(b)/C-3]
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS [ 26 (a) / C-3 ]
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI(M) pipe medium quality (Bansal/Jindal make) incl. making cc (6:2:1) muffing 600x600x750 mm in size with 3 mm thick neatly finished cement plaster incl. S & F 8”x6”x4” C.I. looping cable box incl. S & F 40 mm. dia. G.I.(M) 1.5 Mtr. Long arm bracket for fixing flood light & neccy connection by 2x 1.5 sq mm Cu wire. This is incl. painting as per GS.
S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC.
Supply & Fixing of 240V, 60 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Crompton Geaves-Cat no.LSTP-60-CDL- or equivalent model of Philips/Bajaj//wipro/Havells as approved by E.I.C) on existing MS Pipe/Mini Pole as per direction of E.I.C
S & F 1 phase 230V,MF-1 Starter with over load relay for compound light(Make: L & T , MF-1 cat No :SS97227OOCO or equivalent as approved by EIC)
Painting of any steel/ iron surface with 2 nos. of aluminium coats of paint over 1 coat of RO priming with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint for single/double/triple arm bracket
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil. [1(b)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-10 SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
Making holes on brick wall / RCC ceiling 125 mm depth having dia of following sizes :125 mm depth, 100 mm dia. as to GS.[9 / E-3]
Add GST @12% Rs.
Add LWC @1% except item no.-12,26 & 28:- Rs.
B.S.M ELECTRICAL
R.D.ELECTRICAL ENGINEERING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .