Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 CrAccepted-AOC | ₹4.4 Cr | L1 | Accepted-AOC L-1 Bidder |
| 2 | L2₹4.5 Cr+₹8.0 L (1.81%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹4.5 Cr+₹8.0 L (1.81%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹4.5 Cr+₹9.4 L (2.14%)Rejected-Finance GOKUL APARTMENTS BLOCK C SHIVMANDIR ROAD PUNJABI PARA SILIGURI 734 401 WEST BENGAL | SILIGURI | WEST BENGAL | 734401 | ₹4.5 Cr+₹9.4 L (2.14%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹4.7 Cr+₹32.0 L (7.29%)Rejected-Finance PO HASIMARA NEW MARKET DISTT ALIPURDUAR STATE WEST BENGAL PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹4.7 Cr+₹32.0 L (7.29%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹4.9 Cr+₹54.5 L (12.4%)Rejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹4.9 Cr+₹54.5 L (12.4%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹5.5 L
Closing Date
24 Apr 2021, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE SILIGURI ZONE, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI PIN 734 008 WB
ADDITION/ALTERATION AND SPECIAL REPAIR TO JCOs/OR MD ACCN AT BENGDUBI UNDER GE BENGDUBI
2021_MES_426931_1
98725/BENG/SZ/E8
Open Tender
Civil Works
Item Rate
365 days
Benddubi
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
GE BENGDUBI
₹5.5 L
Yes
16 Jun 2021
1 Mar 2021
26 Apr 2021
1 Mar 2021
24 Apr 2021
12 Apr 2021
1 Mar 2021 - 12 Mar 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debries/rubbish outside the MoD land complete all as specified and directed.
M&L for coloured Non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors surfaces, set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M&L for coloured Glazed ceramic tiles 300mm x 450mm x 7mm (Square/rectangular)as in vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed
M&L for coloured Non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floor etc set and jointed in neat cement slurry complete all as specified and as directed.
M&L for coloured Non skid ceramic tiles 7 to 8mm thick (Square/rectangular) of size 600mm x 150mm, as in vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) for laying finishes in vertical surfaces, skirting, dado etc and like complete all as specified and as directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in cement mortar of any description including removing retrived debries outside the MoD land complete all as specified and as directed.
M&L for 18-20mm thick Granite (of any type) Slab machine cut, single piece in kitchen platform (projected from the edge of the slab upto the extant as directed by Engg-In-Chage), moulding/rounding the edges of the slab with groves at bottom as drip course including provision of suitable size hole for inserting LPG gas pipe into granite slab and RCC base slab also laid over and including 20mm thick backing layer in cement mortar 1:4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
M&L for 18-20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over and including 15mm thick backing layer in cement mortar 1:4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
M&L for 18-20 mm thick machine cut Kota stone slab as in flooring over and including 20 mm thick screed bed in cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and complete all as specified and as directed.
M&L for 18-20 mm thick Pre polished machine cut Kota stone slab in single piece as in treads (including making 3 parallel grooves on kota stone Treads), including moulding/rounding tthe edges of the slab, over and including 20mm thick backing layer in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and as directed.
M&L for 18-20 mm thick Pre polished machine cut Kota stone slab in single piece as in risers, skirting, dado etc including moulding/rounding tthe edges of the slab, over and including 15mm thick backing layer in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and as directed.
Taking down wooden/steel chowkat with shutter not exceeding 1.5 sqm each complete all as specified and as directed.
Taking down wooden/steel chowkat with shutter exceeding 1.5 sqm and not exceeding 4.00sqm each complete all as specified and as directed.
Taking down shutter of any description exceeding 1 sqm and not exceeding 2 sqm each complete all as specified and as directed.
S&F 105X60mm size pressed steel door frames with one or more rebates including necessary fixing lugs, hinges lock strike plate, etc including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F 165X60mm size pressed steel door frames with one or more rebates including necessary fixing lugs, hinges lock strike plate, etc including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and drawing as shown SSR Part II Section 8 complete all as specified and as directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F Factory Made Solid PVC Moulded Door Shutter, (wood free EPS) 28 to 30mm thick (stiles), with 4 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, as per specification & drawing as shown SSR Part II Section 8 complete all as specified and as directed.
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F 25mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including 4mm thick second class hardwood edging to the exposed edges of shutters complete all as specified and as directed.
S&F factory made 35mm thick second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); complete all as specified and as directed. Note:- S&F glass or guage shall be meadured and paid seperately under appropiate items.
S&F mild steel confirming to Fe-290(Gde E-165) framed work as in doors or gates of angle or other section with gusset plates, rails, braces, ladder etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F mild steel conforming to Fe.290.Gde-E-165 Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L for dismantling broken/damaged frames of steel windows/ventilators by necessary cutting and replacing the damaged sections of window/ventilators frame by necessary cutting weliding griding etc and refixing the same in the existing position and smooth functioning of old shutters including replacements of hinges as required including one coat of red oxide, zinc chrome primer complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames glazed with putty or fixed with beadscomplete all as specified and as directed.
S&F 3.00mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m including glazing pins/clips each pane complete all as specified and as directed.
S&F 3.00mm thick , Figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sq. m including glazing pins/clips each pane complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as in steel windows with and including suitable size of MS flat complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as in wooden shutters complete all as specified and as directed. Note:- Cost of wooden beading is included with Wooden Shutters as given here-in -before
S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section150mm long complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specified and as directed.
S&F for sliding door bolt of 250mm long plate Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F of 100 mm MS steel butt hinges, heavy weight, complete all as specified and as directed.
S&F of 150mm size Aluminium handles, cast type, anodised complete all as specified and as directed.
M&L for Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed.
S&F Continuous (piano) hinges,30mm Width of flaps (when open) in mm mild steel, bright finish or electrogalvanised complete all as specified and directed
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings including ridges, hips, valleys and flashings complete all as specified and as directed.
S&F pre- painted galvalume aluminum zinc coating GI based trapezoidal profiled steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and frame work of any description complete all as specified and as directed.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to urrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Hangers 6 mm dia. G.I. (upto 1800mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed.
M&L 4mm thick Pre Painted Non asbestos fibre cement desiginer building boards (600mm x 60mm) fixed or laid/ inserted to GI framework with screws complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Rolled mild steel Joist, channel, angle, or tee sections, Fe-410- W(Gde-E-250)quality B fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) including one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the MoD land, all as specified and as directed.
M&L for rendering 5mm thick plastering in CM (1:3) on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface fair and even without using extra cement.complete all as specified and as directed.
M&L for 15mm thick rendering with cement mortar (1:6) on other than fair faces of brick work finishing the surface fair and even complete all as specified and as directed.
M&L for 20mm thick rendering with cement mortar (1:4) on fair faces of brick work in two layers (10mm & 10mm)seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
Supply only Liquid water proofing compound conforming to IS: 2645 specification complete all as specified and as directed.
Taking up or down 15mm bore GI pipe and connection complete all as specified and as directed.
All as per item No.1.52 above but 20mm bore GI steel tubing and connections complete all as specified and as directed.
All as per item No.1.52 above 25mm bore GI steel tubing and connections complete all as specified and as directed.
S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed.
All as per item No.1.55 above but 20mm bore pipe
All as per item No.1.55 above but 25mm bore pipe
Dismantling water tanks of capacity exc 250 ltrs and not exc 500 ltrs complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) (confoirming to IS 12701-1996) multi layer hoisted and fixed in position 500 ltrs capacity complete all as specified in SSR Part I complete all as specified and as directed
S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) complete all as specified and as directed
S&F in repair 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
M&L for Hard drawn steel wire fabric in available size, weight not exc 4.00Kg/Sqm, fixed in tank caging including welding, riveting, framing etc complete all as specified and as directed
Taking out unserviceable APP membrane with plaster from roof surfaces and removing debries outside MoD land all as specified and as directed
M&L water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top (i) Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete (ii) Rendering 10mm thick in CM (1:4) on existing roof surface true to level after applying cement slurry @ 3Kg/Sqm.. (iii) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm. (iv) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.60 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 150gms per Sqm. Polymeric membrane shall be taken to a height as required at site/30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (iv) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions. Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted. (b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction.
Demolition of brick work built in cement mortar of any description complete all as specified and as directed.
M&L for brickwork with fly ash bricks straight or curved on plan exc 6mtr mean radius built in cement mortar (1:6) by using old size bricks complete all as specified and as directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400m with and including 32mm CP waste coupling and 32mm PVC waste pipe 610mm long and cutting for and pinning in ends of brackets or erecting stand, brackets complete all as specified and directed
S&F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed..
S&F in repair 0.5mm thick stainless steel plate rack of size 900mm x 600mm x 250mm complete all as specified and as directed.
S&F in repair Vitreous China, semi-pedestal pattern (Anglo-Indian Type), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, jet spray(SS304) with 1mtrs flexible PVC tube and plate complete all as specified and as directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F in repair brass chromium plated shower rose of 125mm size with or without swivel joint with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair valveless double action syphonic action 10 ltr capacity PVC flushing cistern low level white colour including PVC connection PVC flush pipe of required length complete all as specified and directed
S&F 15mm bore bib taps, long body, cast copper alloy chromimum plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F 15mm bore 2 way bib taps, cast copper alloy chromimum plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repairs 15mm bore stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type), screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed.
S&F in repair 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed..
S & F 15mm bore PVC Connection with PTMT nut of length 450 mm complete all as specified and directed
S&F in repairs 32mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed
S&F in repair for 75mm dia (of outlet) Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed..
Dismantling cast iron pipes upto 100mm bore, jointed in cement mortar and taking out of trenches, walls complete all as specified and direcrted.
M&L 100mm bore Cast iron soil, (Sand Cast) waste and vent pipes in any length with or without ears, with cement joints, laid in trenches, complete all as specified and as directed.
M&L 100mm bore Cast iron soil,(Sand Cast) waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and as directed.
M&L 75mm bore Cast iron soil, (Sand Cast) waste and vent pipes in any length with or without ears, with cement joints, laid in trenches complete all as specified and as directed.
M&L 75mm bore Cast iron soil, (Sand Cast) waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, complete all as specified and as directed.
S&F of 75mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured)complete all as specified and as directed.
S&F 100mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured)complete all as specified and as directed.
S&F 75mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed.
S&F 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed.
Taking down PVC rain water pipe (any size or pattern)including all fittings, head shoe etc complete all as specified and as directed.
S & F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed.
S&F 110mm dia PVC (SWR) bends of any radius complete all as specified and as directed.
Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing debries outside the MoD land complete all as specified and as directed.
M&L for 25mm thick Cement concrete type B0, (1:2:4) (using 12.5mm graded stone aggregate) as in sub base of flooring for layind floor finishes complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position including removing debries outside the MoD land complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.complete all as specified and as directed.
M&L for 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
M&L for Reinforced cement concrete (design mix) M-25 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for Reinforced cement concrete (design mix) M-25 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for Reinforced cement concrete (design mix) M-25 (20mm graded aggregate) as in Chajjas complete all as specified and as directed.
M&L for TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat, roughed finished surfaces, complete all as specified and as directed.
M&L for Formwork to chajjas, troughs and similar items including edges flat, roughed finished surfaces, complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) roughed finished surfaces, complete all as specified and as directed.
M&L for 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, for cupboard shelf fixed with and including second class hard wood supports fixed with screws as required at site complete all as specified and as directed.
M & L for providing plain cement concrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in copings, bed block,filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing plain cement concrete type B-1, (1:2:4), (using 20 mm graded stone aggregate), as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,kerbs or mud stops, rounded or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
S&F in repair mild steel, 150mm, ordinary rat tail rod pattern springs including roller and roller plate completes complete all as specified and as directed .
M&L for 20mm thick rendering with cement mortar (1:3) as in sides and soffits of sunken floor, mixed with water proofing compound as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
M&L for PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate) as in filling of sunken portion complete all as specified and as directed.
M&L for Cutting holes into or through brick walls built i in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete. superficial area exc 150Sqcm and not exc 400Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed.
S&F decorative stainless curtain rod of wooden finish 20mm dia thickness not less than 0.75mm, fixed with curtain rod holder fixed in walls with screws and finials caps with 6 Nos of curtain ring per RM complete all as specified and directed. Note: Curtain rod holder and finials caps will be measured and paid seperately at Supply only rates)
Supply only decorative stainless curtain holding braket suitable for holiding 20mm curtain rod heavy duty complete all as specified and directed.
Supply only decorative stainless steel finial end cap suitable for curtain rod of 20mm dia as approved complete all as specified and directed.
M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over and including wall care putty as required for obtaining optimum smooth finish (2mm minimum thickness) and a coat of primer complete all as specified and directed.
M&L for complete removal of existing treated surfaces of walls including cornices, pillasters and other wall feathers etc by washing rubbing down and stopping of distempered and painted surfaces and applying two coats of oil bound distemper over and including wall care putty for obtaining optimum smooth finish (2mm minimum thickness) and a coat of primer including necessary preperation of surfaces, complete all as specified and directed.
M&L for prepartion of newly plastered surfaces of walls and applying two coats of exterior emulsion weaher coat paint over a coat of primer complete all as specified and directed.
M&L for complete removal of existing treated surfaces of walls and applying two coats of exterior emulsion weaher coat paint over a coat of primer including necessary preperation of surfaces complete all as specified and directed.
M&L for preparing newly plastered or unplastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed.
M&L for preparartion of old ceiling surfaces and applying two coat of white washing complete all as specified and as directed.
M&L for preparing new wooden surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint over pink primer complete all as specified and as directed.
M&L for preparing old wooden surfaces of any description, not otherwise describe over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
M&L for cutting and cleaning of vegetation, shurbs, grass, roots etc from roof/wall/chajjas surfaces, diging out roots from the surfaces carefully, and filled with cement mortar in 1:3 over bituminous primer and removing debries of the site complete all as specified and as directed.
Demoliation of PCC padding of any description over RCC roof surfaces using chisel/concrete cutter carefully, and no damages shall be made to the existing slab and removing debries outside the MoD land complete all as specified and as directed. Note:- The work shall be carried out with due care so that any damages to the existing slab does not take place. Use of hammer shall be strictely prohibited. Engg-in-Charge will certify that demoliation is carried out using chisel/concrete cuttter only if any damage occurs to the existing slab during demoliation of PCC padding due to contractors default the same shall be made good by the contractor witout any additional cost.
M & L for providing plain cement concrete type B1, (1:2:4), (using 20mm graded stone aggregate), as in roof padding for levelling course, chajjas kerbs/stagging for water tanks etc and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing plain cement concrete type C-0, (1:3:6), (using 12.5mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Demolition of cement concrete (Unreinforced) Concrete of any description and in any position not otherwise specifically provided for including removing debries outside the MoD land complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 as in sub base of flooring using 40mm graded stone aggregate finishing cement concrete surface even & fair complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for Machine pressed precast pre polished, coloured conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade set with grey cement and pigment complete all as specified and as directed.
Surface excavation in soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting outcomplete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
Demolition and breaking up drain pipes 150mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including removing debries out side the MoD land complete all as specified and as directed.
M&L for TMT bar 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Precast Reinforced cement concrete (design mix) M-25 (20mm graded aggregate) cement concrete (1:2:4), type B1 (Using 20 mm graded stone aggregate)as in cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar (1:4) complete all as specified and as directed. Note:- Reinfocements will be measured and paid seperately under appropiate item
M&L for 15mm thick plaster of cement mortar (1:4) rendering on brick work or concrete surfaces mixed with water proofing compound as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in mass concrete complete all as specified and as directed.
M&L for 150mm bore Salt glazed stoneware drain pipes laid in trenches and jointed in cement mortar(1:1) complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in surface channels and drain complete all as specified and as directed.
M&L for 150mm bore Concrete bed in cement concrete 1:3:6 Type C2 (40mm graded aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2(using 40 mm graded stone aggregate) as in surface channels and drain complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
Add to or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. Note:- Rate quoted is for adjustment of rate only for the actual size excuted at site for the item no 2.48 mentioned as above
M&L for prepartion of newly plastered surfaces of ceilings and applying two coats of oil bound distemper over and including wall care putty as required for obtaining optimum smooth finish and a coat of primer complete all as specified and directed.
M&L for providing 25mm GI pipe light grade spout pipe in sunken slab complete all as specified and directed. Note:- Spout shall project beyond 30cm from the outer face of wall of wall.
M&L for 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed.
M&L for preparation of new plastered surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed
M&L for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and as directed.
M&L for Stops, commas, short lines, dashes, hyphens, brackets, etc. complete all as specified and as directed.
M&L for 100mm bore cast iron pipe extra over cast iron pipes and fittings if lead joints is provided in lieu of cement mortar complete all as specified and as directed. Note;- No deduction shall be made for not providing cement joints
M&L for 75mm bore cast iron pipe extra over cast iron pipes and fittings if lead joints is provided in lieu of cement mortar complete all as specified and as directed. Note;- No deduction shall be made for not providing cement joints
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and as directed.
S&F Stainless steel Soap dish of size 10cm x 13cm fixed to plugs with chromium plated brass screws complete all as specified and as directed.
M&L for preparing new Steel surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparing old steel surfaces of any description, not otherwise describe over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
Cutting chases in walls for taking out concealed 15mm bore GI pipe to the required sizes and making good the same after relaying/refxing GI pipe in cement mortar 1:3 to match with adjoining surfaces complete all as specified and as directed. Note;- Taking out GI pipe and providing new pipes shall be measured and paid seperately under appropiate items.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. including cutting chases of exsisting wall for wall taking out concealed conduit ec. and making good disturbed surfaces of walls, floors, etc as per existing specification after providing point wiring under respective items here-in-below complete all as specified and as directed.
Taking down main switches and DB's of any sizeand capacity including board/junction box complete all as specified and as directed.
M&L for concealed point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed. Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost complete all as specified and as directed for the following :- Item Continued as 2.69 to 2.72
(a) One light point/Ceiling fan/Exhaut fan/bell point controlled by one way switch 5/6 amps.
(c) One socket out let 5/6 amps point on the same board
(d) One socket out let 5/6 amps point on the independent board
(f) One Light point controlled by two numbers two way switches 5/6 Amps.
M&L for concealed point wiring complete for one socket outlet 15 Amps point on independent board with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, (clear depth of the box not less than 60mm) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, etc duly earthed. Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost complete all as specified and as directed
M&L for concealed point wiring complete for one socket outlet 15 Amps point on independent board with 4 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed. Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost complete all as specified and as directed
S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed.
S&F Switch Socket outlet 2 in 1, 3 pin, 5/6 Amps complete all as specified and as directed.
S&F Switch Socket outlet 2 in 1, 3 pin, 5/6 Amps and 15/16Amps flush type complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 5/6 Amps two way complete all as specified and as directed.
S&F Bell push, flush type, 5/6 amps complete all as specified and as directed.
S&F bell buzzer AC Single pole 220/240 Volts, surface type complete all as specified and as directed.
S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed.
S&F step type electronic fan regulator flush type (05 steps) complete all as specified and as directed.
S&F LED luminarie tube light fitting basic all purpose surface/wall mounted 4 feet LED batton with polycarbonate housing & integrated electronic driver, with high efficient LEDs 18 watt, (or nearest next higher wattage) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed.
S&F LED luminarie tube light fitting basic all purpose surface/wall mounted 2 feet LED batton with polycarbonate housing & integrated electronic driver, with high efficient LEDs 9 watt, (or next nearer higher watt) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings/pendent fitting including 7watt (or nearest next higher wattage) LED lamp complete all as specified and as directed.
S & F energy saving & environment friendly long life 18 Watt,(or nearest next higher wattage) CT ≥ 5700 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including 25mm bore GI pipe bracket (Light Grade) of length 1.0 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed.
Dismantling/taking down old ceiling fans of any sweep, dismantling of blades and refixing the same in existing position after replacement of two nos spilt pins, one connection block and one rubber seal including provision of cable from ceiling rose or connector to fan as per existing size complete all as specified and as directed.
M&L for painting of ceiling fans of any sweep and make with one coat of syntheic enamel paint of approved make and tint by spraying including necessary preperation of surfaces, removing all dust, dirt, oil marks, etc and filling in cavaties with filler materials and writing Serial No./MES No in BLOCK letters of the fan with black colour(Height of letters not exc 2cm) complete all as specified and as directed.
S&F of exhaust fan metal body with louvers 300 mm sweep, 1320 RPM or more, Air Delivery not less than 1600 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete and provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan complete all as specified and as directed.
S&F exhaust fan with automatic back shutter louvers 250 mm sweep, 1400 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan complete all as specified and as directed.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Triple pole & neutral with ated bus bar, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed. .
S&F Sheet metal enclosure for 12 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with ated bus bar, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed. .
S&F MCB, SPN, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
S&F MCB, FP, C Series 415 Volts, 40-63 Amps 50 HZ, 10KA complete all as specified and as directed.
Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories ISI marked including taking out old unserviceable submain wiring and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length.
S&F metal clad socket outlet with MCB Single pole and Neutral 20-32 Amps, 240 Volts including sheet metal encloser complete fixed on wall including cutting/ chassing and making good the distrubed surfaces of wall including necessary electrical connection by using proper size of copper lugs complete all as specified and as directed.
Material and labour for earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (M-15)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
S & F Bulk head LED fitting with injection molded Polycarbonate housing suitable for 10 Watt (or nearest next higher wattage) with IP 66 protection & impact resistance not less than IK-10 complete with integrated type, with high efficiency electronic driver, & high brightness LEDs, luminaire efficacy > 100 lumens/Watt, power factor ≥ 0.95, operating range 140 to 270 V, 50 and connecting complete all as specified and as directed.
S&F Decorative wall light fixture made up of Polycarbonate suitable for 5 Watt (or nearest next higher wattage) LED light having B-22 base lamp holder with and including 10 watt LED lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting complete all as specified and as directed.
Supply, installation, testing and commissioning of electric water heater, storage vertical type, BEE 5 star rated, 25 Litres capacity 230 volts AC, 50 Hz comprising of high wattage heating element for instant heating, extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non-ferrous pressure plate with & including provision of 04 Nos grouting bolts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable/flexible chord complete all as specified and as directed.
S&F RCBO's double pole 32Amps, 240 Volts, 30mA, 50 HZ, 10KA complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed.
M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed.
M&L for 40mm bore GI pipe medium grade with all necessary fittings (ISI marked) laid in trenches complete all as specified and as directed.
S&F 25mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair 40mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Taking up or down GI steel tubing and connections 40mm bore complete all as specified and as directed.
M/S R. K. INDUSTRIES
M/s KASHMIRA SINGH BARMI AND SONS
M/S Sohanlal Agarwala
MAA BHAGWATI ASSOCIATES
M/S JYOTI SHARMA AND SONS
Prasur Electricals & Engineering Co.
DEEP NIRMAN
NARSINGH DEVELOPERS LLP
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .