Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹15.4 L+₹1.3 L (9.09%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
29 Aug 2023, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR RENEWAL MAINTENANCE OF INTERNAL ELECTRIC WIRING AND CERTAIN CONNECTED WORKS INCLUDING OT LIGHT AT PHASEI MH KHADKI UNDER GE MH AND RH KHADKI
2023_MES_606250_2
8457/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹40,000
6 Nov 2023
9 Aug 2023
31 Aug 2023
9 Aug 2023
29 Aug 2023
17 Aug 2023
9 Aug 2023 - 22 Aug 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be made as per conditions laid down under schedule of credit separately) and making good disturbed surfaces of walls, floors, all as specified.
Taking down old unserviceable submain wiring of any type any size complete all as specified and directed with casing capping / surface conduit
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, PVC concealed/surface conduit on wall/roof/floor etc, ISI marked with suitable accessories , mild steel/pressed steel sunken box of 1.2 mm thick and 60 mm deep (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for the following:-
One light point controlled by one switch complete.
One Fan point controlled by one switch complete.
One 5 pin 6 Amps socket outlet on independent board.
One 5 pin 6 Amps socket outlet on same board.
One bell /buzzer point controlled by one push button on the same board with other switches or indipendent.
One light point controlled by two way switch complete.
All as per item No 4.00 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 v grade PVC insulated but unsheheted copper conductor FRLS cable 1100 volts grade and 2.5 sqmm PVC insulated but unsheathed FRLS cable as earthwire for 16 Amps power point on independent board complete all as specified and directed by Engr-in-charge.
S & F switch piano type, one way, 6 Amp all as specified
S & F switch piano type 16 Amps all as specified
S&F Bell push, flush type 6 Amp all as specified
S & F switch piano type two way 6 Amps all as specified
S&F Bell push, Modular type 6 Amp all as specified
S & F socket outlet 2 in1,3 pin 5 Amps all as specified
S & F socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type in all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type in all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 Amps flush type all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 and 15 Amps Box type in all as specified
S & F switch socket combination 2 in 1, 3 pin, 5 Amps Box type all as specified and directed by Engr-in-Charge all as specified
S & F PVC ceiling rose surface type three terminals type in replacement/ repair all as specified
S & F Buzzer / ding dong AC 230 volts, 6 Amp single Phase in white /Ivory colour finish inreplacement/ repair all as specified
S &F in replacement lamp holder, Insulated body with back plate for batten fitting complete all as specified.
S & F in repairs surface wall mounted Regal Batten with and including T8 tube rod energy efficient 20 W LED (four feet) complete in all respect including taking down old conventional type tube light fitting.
S & F in repairs surface and wall mounted LED T5 integrated batten Batten with integrated electronic driver energy efficient 10W LED (Two feet) decorative complete in all respect including taking down old conventional type tube light fitting.
S & F including taking down square 600 mm X 600 mm, 36 w-42 w reccese mounted bottom opening LED fitting including, LED Lamp with powder coated CRCA housing and polycarbonate diffuser, LED Fixture system wattage 36 -42 w,140V -260 V AC, System lumen out put min 3600 lumen in 36 w and 4200 lumen in 42 w with 5700-6500 K CCT with PF>0.95 CRI>=80 and with <=10 % THD, with Min 2.5 KV surge protection in Built complete LED fixture with BIS Mark and Registration No.
S & F in repair 600 mm X 600 mm, 36 w-42 w reccese mounted bottom opening LED clean room light fitting including, LED Lamp with powder coated CRCA housing and polycarbonate diffuser, LED Fixture system wattage 36 -42 w,140V -260 V AC ,System lumen out put min 3600 lumen in 36 w and 4200 lumen in 42 w with 5700-6500 K CCT with PF>0.95 CRI>=80 and with <=10 % THD, with Min 2.5 KV surge protection in built complete LED fixture with BIS Mark and R Registration No.
S & F in repairs 20W ultra bright glass LED Tube Rod of size 4 ft all as specified and directed.
S & F wall mounted extruded PVC housing high quality indoor batten LED tube 20 watt colour temperature 6500 K (4' long) lumen 2000 - 3000, PF> 0.9, THD less 10% diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement including taking down old conventional type tube light fitting as directed by Engr-in-charge.
S & F in repairs new genration energy saving environment friendly long life 25 Watt LED Bldg security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seprate driver compartment with IP66 Protection and impact resistance of IK07 Building security lights.
Supply and fix in repair ultra bright LED PLL with very high efficacy suited for installation in existing 2G11 lamp holder to give glare free light of capacity 18 watt, 4 pin suitable for existing fitting and all as specified and directed Make : Havells/Wipro/HPL/Philips
Supply and fix in repair of LED Driver suitable for recess mounting LED Light fitting 36W to 42W watt of (any Make) 600 mm x 600mm size. Make : Crompton / bajaj/ Havells/HPL/Syska
Supply & fix PIR Motion sensor of detection range 360, detectction distance more than 6 mtr,installation height 2.5 to 4 m and detection movement speed .06-1.5 m/s including necessary wiring with 2.5 sqmm three core multi stranded copper condcutor 1100 v grade from light/ main board to sensor all as specified and directed. Make Crabtree: Product code ACSBA005 equivalent approved make.
Supply & fix PIR surface mounted Motion sensor of detection range 360, detectction distance more than 20 mtr,installation height 2.5 to 6 m and detection movement speed .06-1.5 m/s including wiring with 2.5 sqmm three core multi stranded copper condcutor 1100 v grade from light/ main board to sensor all as specified and directed. Make Crabtree: Product code ACSBA003 equivalent approved make.
S & F for MCB DB VTPN 4 way with provision for FP MCB/ Isolator/ RCCB etc as incommer and SP/TP MCBs as out going double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and as directed
S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB TPN 8 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and as directed.
S & F for sheet metal enclosure MCB SPN DB way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and as directed of following Size.
SPN DB 8 way
SPN DB 4 way
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 1.5 sqmm 1100 volt grade drawn into PVC conduit of size 25mm dia including 1.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 1.5 Sqmm, one run of 1.5 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 2.5 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 2.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 2.5 Sqmm, one run of 2.5 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 4 Sqmm, one run of 4 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC conduit of sutaible size including 6 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Two run of 6 Sqmm, one run of 6 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC conduit of suitable size including 4 sqmm PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Four run of 4 Sqmm, one run of 4 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC conduit of suitable size including 6 sqmm PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note :- Four run of 6 Sqmm, one run of 6 sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
S & F in repairs MCCB TPN rated capacity 63 Amps, 415 volts breaking capacity 16 KA complete all as specified and as directed.
S & F in repairs MCCB TPN rated capacity 100 Amps, 415 volts breaking capacity 16 KA complete all as specified and as directed.
S & F in repairs MCCB TP rated capacity 25 to 100 Amps, 415 volts breaking capacity 16 KA complete all as specified and as directed.
S & F in repairs MCB Single pole and neutral (SPN) rated capacity 6 to 32 A, 240 volts breaking capacity 10 KA complete all as specified and as directed.
S & F in repairs MCB Single pole (SP) rated capacity 6 to 32 A, 240 volts breaking capacity 10 KA complete all as specified and as directed.
Taking down carefully electric geysers of any make, type and capacity after disconnecting of electric and water connections, opening of bottom cover, checking of all parts and taking out copper / tank, checking of its leakage and removing the dust, brazing the leakage and replacement of worn out spares and resassembling complete geysers and refixing back its position all as directed. Note : Spares shall be measured and paid sperately under relevant item of this BOQ as supply only.
Supply only thermostats ISI maked as required at site for geyser of capacity 25/35/50 ltr of any make all as directed by Engr-in-Charge.
Supply only safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
Supply only heating element of rating 1/1.5/2 KW as required at site including rubber washers all as specified and directed by Engr-in-charge.
S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engineer-in-charge.
S & F in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 CM long for hot water connection all as specified and directed by Engineer-in-charge.
S & F in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
M & L for refixing of geysers of any capacity to walls by grouting with new nut,bolts and refiixng the geysers at a location directed by Engr-in-charge complete with all necessary pipe connections, testing.
S&F plug top 16 Amps flush type complete.
M & L for stop valve, cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore
Taking down carefully ceiling fan of any make, size from its location,dimantling complete fan ,examine complete parts thoroughly, servicing oiling, greasing all parts and complete overhauling of fan including checking of winding, replacement of small parts such as split pin, nut bolt,screw and assembling complete fan and make fully functional with replacement of old unservicable rewinding with new rewinding of fan, refixing the fan to its original position including replacement of three core PVC insulated multi strandard copper wire 0.5 sq mm 1100 Volts grade from fan connector to ceiling rose complete all as directed. Note : Ball bearing, bush fan blade etc will be measured and paid seperately under relevant item of schedule as supply only.
Supply only ball bearing(DE/NDE) to match the existing make suitable for 1200/ 1400 mm sweep ceiling fan complete all as specified and directed by Engr-in-charge. Make : SKF/NBC or equivalent
Supply only fan regulator suitable for 1200/1400 mm ceiling fans (electronics step type)
Supply only capacitor 2.5 mfd for ceiling fan all as specified and as directed by Engr-in-charge.
All as per item No 55 above but Exhaust Fan of sweep 150-300 mm
Supply only ball bearing to match the existing make suitable for 275-450 mm exhaust fan. Make : SKF/NBC or equivalent
Supply only capacitor 4 mfd for exhaust fan all as specified and as directed.
Taking down carefully old unserviceable existing copper strip of size 20 mm x 3 mm and Supply & fix copper strip 20 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr-in-Charge.
Supply & fix in replacement /repair Aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr In Charge.
S&F in repair aluminium strip 25 mm x 3mm complete with saddles and screws for fitting the strip.
Supply & Fix in repair GI strip 32 mm x 6 mm complete with saddles and screws for fitting the strip.
M&L for Air terminations single pointed Aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof including taking down old all as directed.
Supply & fix four pointed (centre tip 150mm and side spike 75mm) copper spike lighting arrester heavy duty copper rod opf size 15 mm dia both end screwed for easy fitment and 1.5mtr long and heavy duty copper base plate duly drilled on four corners of size 75mm x 75mm, with necessary fixing arrangement on Top/side of pole complete including taking down old all as spcified and directed by Engineer-in-charge.
Supply and fix test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. head screw including taking down old all as spcified and directed by Engineer-in-charge.
Material & labour for fixing of 50mm bore GI Pipe medium grade galvanised 1.5 mrt. long fixed on wall with proper fixing and clamping of strip & 1.5 mtr to 300mm long copper/ Aluminium lightening arrester rod with all fitting and fixed complete to wall or roof top of bldg. Note: Joints shall be made with welding to get proper conductivity.
Material and labour for earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 2.25 metres below normal ground level connected to galvanised iron earth strip of size 20x3mm by means of bolts check nuts and washers of brass/ bronge all as shown in electrical plate No 3 connecting to earthing test point all as specified and indicated and testing on completion including excavation earth work drilling holes for electrode, PCC pit in PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete. Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length. All the joints shall be made with welding to get proper conductivity. Rate required deemed to be including excavation by compressor machine or breaker for soft /disintegrated rock to required depth and results of earthing should be below 1 Ohm.
M & L for maintenenace/servicing including attending fault on call basis and repairs philiux / Meditech / HOSPI major with standard /LED OT light of capacity (140000Lux or as per exisiting) Make Phililux / Technomed, as prescribed in repairs and maintenance manual, including fixing/replacement of spare parts (if required). The maintenance schedule shall be under each OT:- (i) Dismantling the complete OT light fittings (ii) Checking and servicing/repair and maintenance of OT Lights (iii) After repairing/servicing/Maintenence, reinstallation, realignment of OT fittings Note:- (i) Spares requried for above maintenece will be measured and paid separeataly under relevant items of this BOQ as supply only. (ii) Servicing of the above item shall be carried out by the authorized service providers specially for OT light. (iii) Any break down during the contract period should be attended by contractor with in a day.
Supply only LED Panel with 19 LED bulb yellow and white combination with Teflon coated wire suitable for Modle HOSPI CT 5+5 HEX
Supply only Controller touch Panel suitable for Modle HOSPI CT 5+5 HEX
Supply only SMPS input 220 V AC output 24 V 5 amp DC suitable for Modle HOSPI CT 5+5 HEX
Hydraulic arm set with base plate suitable for Modle HOSPI CT 5+5 HEX
Supply only 30 Minute battery backup system unit suitable for Modle HOSPI CT 5+5 HEX
M & L maintenance /servicing including attending fault on call basis and repairs, Phililux Mobile OT light capacity Make: Phililux, as per prescribed in repqirs and maintenance manual, including fixing / repalcement of spare parts (if required). The maintenance schedule shall be under each OT (i) Dismantling the complete OT light fittings (ii) Checking and servicing/repair and maintenance of OT Lights (iii) After the repairing/servicing/Maintenence, reinstlltion realignment of OT fittings Note:- (i) Spares requried for above maintenece shall be measured and paid separeataly under relevant items of this BOQ as supply only. (ii) Servicing of the above item shall be carried out by the authorized service providers specially for OT light of Philips make. (iii) Any break down during the contract period should be attended by contractor with in a day.
Supply only diffusers for for Phililux major with standard OT light Make: Philips or recommended by manufacturer or service provider.
Supply only Reflector for Phililum major with standard OT lights Make: Philips or recommended by manufacturer or service provider.
Supply only Bulb Holder for Phililum major with standard OT light Make: Philips or recommended by manufacturer or service provider.
Supply only Halogen Bulb 12 V 50 Watts for Philium major with standard OT light Make: Philipsor recommended by manufacturer or service provider.
Supply only filter glass for Phililum major with standard OT light. Make: Philipsor recommended by manufacturer or service provider.
Supply only Rotary Switch CL 05 for Phililux major with Standard OT light Make: Philipsor recommended by manufacturer or service provider.
Supply only Rotary Switch CL 06 for Phililux major with Standard OT light Make: Philipsor recommended by manufacturer or service provider.
Supply only Condensor CL 01 for Phililux major with standar OT light Make: Philipsor recommended by manufacturer or service provider.
Supply only fuse holder and base for major with standerd OT light light Make: Philips or recommended by manufacturer or service provider.
Supply only Condensor CL 02 for Phililux major with standard OT lights Make: Philips or recommended by manufacturer or service provider.
Repair to CVT 12V 250 by replaceing following burnt items:- (i) Internal wiring as per existing size. (ii) Burnt MCB of existing capacity (iii) Replacment of multi tap, stepdown transformer of existing capacity, (iv) Trial and testing completely directed by Engineer in charge
Repair to CVT 12V 500 by replaceing following burnt items:- (i) Internal wiring as per existing size. (ii) Burnt MCB of existing capacity (iii) Replacment of multi tap, stepdown transformer of existing capacity, (iv) Trial and testing completely directed by Engineer in charge
M/S kirpan Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .