Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.7 LAccepted-AOC MAHESWARI NAGAR IN WARD NO 38 TAMIL NADU TN | L1 | Accepted-AOC Less than coated estimate rate | |
| 2 | L2₹57.4 L+₹2.7 L (4.84%)Rejected-AOC TAMIL NADU | MAYILADUTHURAI | TAMIL NADU | 609001 | L2 | Rejected-AOC more than coated estimate rate |
Tender Value
₹58 L
EMD Value
₹58,000
Closing Date
21 Nov 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner,Tambaram City Municipal Corporati
NO.01,Kalaivani Street , Rajakilpakkam , Chennai -73
Consruction of lifting stations at Kannammal Nagar Om sakthi Nagar in Ward No.22
2024_MAWS_501904_2
1603/2024/E1
Open Tender
Civil Works
Works
90 days
Tambaram city Municipal Corporation, Zone -3
Consruction of lifting stations at Kannammal Nagar Om sakthi Nagar in Ward No.22
2 documents required · 2 mandatory
₹0
₹58,000
28 Jun 2025
16 Nov 2024
21 Nov 2024
16 Nov 2024
21 Nov 2024
16 Nov 2024
Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump , wear resistance with submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size withsewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smoothand designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type , single vane /multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces shoulde provided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be atleast 30% above the operating speed. Pumps should have double bearings between the pump & motor. The bearingslife shall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic couplingdevice including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitatelifting and lowering into guide rails for easy aintenance. Pump shall be provided with a stainless steel lifting chainconforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low dutypumpsets. Casing and impeller should be of CI Gr. FG 260:IS210 more preferably with hardened mpeller.Shaft shouldbe of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible motor shall be operatedwith 3ph, 415 V(+or– 10%), 50Hz(+or-5 %) dry induction type. Motor shall be capable of giving rated output withoutreduction in the expected life span when operated continuously. The rotating assembly shall be dynamically balancedas per standards. The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta orATS starting under any circumstances .The motor shall be suitable for full voltage star delta / ATS starting. The lockedrotor current of the motor shall not exceed 600% of full load current unless otherwise specified. Motor shall be designed to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction of rotation. The motor vibration shall be within the limit specified in applicable standards . Motor should be of IE2, explosion proof compatible for VFD operation together with star-Delta /ATS starter, protection against increase in stator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminal box shallbe provided and to be suitably interlocked with the control panel for tripping the pump in case of increase in temperature beyond set limit. Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS4691. Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with power cable of PVC insulated and PVC sheathed, copper, flexible, round type with required conductor size and number of cores as per starting method and of specified length for continuous use under water and air. The control cable of PVC insulated, PVC sheathed, flexible for stator winding temperaturesensor 3core x 1.5 sq.mm copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall beprovided. Motor shall be supplied with 10m of round submersible copper cable of suitable size. The non clogsubmersible pumpset shall be provided with suitable starter control panel having all protections as mentioned above.(upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta Panel and beyond 25 HP shall be ATS)
20HP Discharge discharge Upto 20 M3/hour Head 20m to 25m Kannammal Nagar
70 HP Discharge 400 to 500 M3/hour
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointingsubmersible cable with proper clamps upto the starter torequired depth and also fixing of riser pipes to therequired depth valves erection clamps, pressure gaugesupto the exterior wall of pump room and erection ofpanel board consisting of TPICN switches starter,Voltmeter, Ammeter, three pilot (indicating) lampscapacitor single phasing preventor, water level guard andlaying and jointing the cables and twin earthing as per IErules etc., complete and testing the pumpset and trail run for 10 days
70 HP Discharge 400 to 500 M3/hour
Supplying and filling the foundation and basement with stone dust in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Supply and Delivery of PVC & DI Pipes etc complete as per Standard specifications
300mm dia DI Pipe Kannammal Nagar
300mm dia DI Pipe Kannammal Nagar
Laying, jointing ,testing 300mm C. I / DI pipes 2.00Mt Depth including earthwork excavation for trenches in hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil, depositing the earth on banks with initial lead of 10 metres and carting of pipes from any of the Board’s stores to the site of work, lowering into trenches and aligning, etc., complete (Timbering included for Depths 2.50m,3.0m,3.5m,..........upto 8.5m)
300mm dia DI Pipe Kannammal Nagar
300mm dia DI Pipe Kannammal Nagar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_596891.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .