Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.9 LAdmitted-Finance | -2.58% | ₹3.9 L | L1 | Admitted-Finance |
Tender Value
₹4.0 L
EMD Value
₹7,940
Closing Date
25 May 2026, 6:00 pmClosed
EXECUTIVE ENGINEER PWD ELECT. DN BANSWARA
EXECUTIVE ENGINEER PWD ELECT. DN BANSWARA
Electrical Repair and Maintenance Work in Ist and IInd Types Residential Building at Banswara.
2026_CEPWD_558428_3
NIT 03/2026-27 EE PWD ELECTRIC DN BANSWARA
Open Tender
Electrical Works
BANSWARA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
AS MENTIONED IN NIT AND CONDITIONS
₹7,940
Yes
29 May 2026
12 May 2026
26 May 2026
12 May 2026
25 May 2026
12 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. | - | - | - | - |
| 2 | 20 mm | 150 | Mtr. | 33 | ₹4,950 |
| 3 | 25 mm | 100 | Mtr. | 47 | ₹4,700 |
| 4 | S&F of following sizes of polypropelene corrugated flexible conduit including gland on both side of flexible conduit as required. | - | - | - | - |
| 5 | 20 mm OD | 30 | Mtr. | 13 | ₹390 |
| 6 | 25 mm OD | 30 | Mtr. | 18 | ₹540 |
| 7 | S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required. | - | - | - | - |
| 8 | 20 mm x 12 mm | 150 | Mtr. | 30 | ₹4,500 |
| 9 | 25 mm x 12 mm | 100 | Mtr. | 36 | ₹3,600 |
| 10 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. | - | - | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 10.33 MB
BOQ_994182.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid