Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.8 L+₹43,409.15 (0.92%)Rejected-Finance AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹49.4 L+₹2.0 L (4.19%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹49.8 L+₹2.4 L (5.12%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹49.9 L+₹2.5 L (5.26%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
26 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR MAINT TO PANELLED SHUTTERS GLAZED SHUTTERS UPVC DOORS AND WINDOWS WIREMESH AND OTHER ELECTRICAL CONNECTED WORKS IN ZONE A AND B AREA UNDER GE I GOS
2023_MES_635139_1
8000/121/2023-24/1020/E8
Open Tender
Civil Works
Item Rate
180 days
GOS
As per tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹70,000
18 Mar 2024
30 Dec 2023
27 Jan 2024
30 Dec 2023
26 Jan 2024
13 Jan 2024
Amount
Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
Taking down shutter of any description area exceeding 1 sqm but n exc 2 sqm each and removing to store complete all as specified and directed.
Taking down shutter of any description area not exceeding 1 sqm each and removing to store complete all as specified and directed.
M&L Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
M&L Second class hard wood 35 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed.
M&L Second class hard wood 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube in opening as per specification and shown on drg SSR Part-II 2010.
S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement , as per specification and shown on drawing in SSR Part-II (2010).
S&F Flush shutters 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking down shutter of any description not exceeding 1 sqm each leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed
Taking down shutter of any description exceeding 1 sqm but not exiding 2 Sqmeach leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed
M&L Second class hard wood 30 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed.
S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, brackets for WHB, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed.
M&L for Cutting holes in brick walls exc half brick but not exc one brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed.
S&F 100 mm long aluminium handles cast type, anodized complete all as specified and directed
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed
S&F 75 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed
S&F in repair 100 mm long aluminium anodized handles fabricated type complete all as specified and directed
S&F in repair 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed.
S&F in repair 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed
S&F in repair 75 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
S&F in repair 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S&F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repairs 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
Hacking out old broken glass (any thickness, size quality or description) form wooden frames or stone, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
S&F 3 mm thick figured glass pin headed type and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories.) (Area not exceeding 2.00 sqm)
S&F 7mm thick aluminium grills of make "Decogrill' model DG 104 surrounded by aluminium 'C' channel with mesh size 75 X 75mm all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
Demolition of brickwork built in cement or cement lime mortar including all quoins, arches pillar etc complete all as specified and directed.
M&L Brick work with flyash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed .
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed
M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and apply three coat of white wash complete all as specified and directed.
M & L for two coats of cement based paint over a coat of primer on new plastered surface of walls including preparation of surface complete all as specified and directed.
All as per item no 54 above but 70 KVAR to 125 KVAR
Replacement of power capacitor box type of 3 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
All as per item no 56 above but 5 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
All as per item no 56 above but 10 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
All as per item no 56 above but 15 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
All as per item no 56 above but 20 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
All as per item no 56 above but 25 KVAR box type heavy duty capacitor 440V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 3 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fixContactors capacitor duty rating 3 phase 415 V suitable for 5 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 10 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 15 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 20 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix Contactors capacitor duty rating 3 phase 415 V suitable for 25 KVAR Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix timer 5 A 0 - 60 seconds 230 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix display/relay unit computerised control of Power Factor Digital type 4 steps 440 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix display/relay unit computerised control of Power Factor Digital type 8 steps 440 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix display/relay unit computerised control of Power Factor Digital type 12 steps 440 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix LED Indicator 20mm dia replaced by old indicator Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply and fix LED Indicator 15mm dia replaced by old indicator Make:- L&T / HAVELLS/ ABB / SIEMENS
Taking down U/S MCB Supply & Fix MCB TP pole 63A .10 KA 415 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Taking down U/S switch ,Supply &Fix switch fuse unit TPN 500 Volts 3 phase with HRC fuses suitable for interior mounting in panel of capacity of 63 Amps each Make:- L&T / HAVELLS/ ABB / SIEMENS
Taking down U/S MCCB ,Supply & Fix MCCB 3/4 POLE 100 A 16 KA 415 V Make:- L&T / HAVELLS/ ABB / SIEMENS
All as per item no 76 above but 200 Amps 4 pole 36KA, 415 V Make:- L&T / HAVELLS/ ABB / SIEMENS
Supply, installation, testing and commissioning of CPRI approved automatic power factor correction (APFC) panel, outdoor type, with front door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level of capacity 100 KVAR ready to use design confiring to relevant IS rated for short circuit rating of 50 KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 415/ 440 Voils, 3 phase 50 Hz, AC , anti corrosive coating to achieve power factor from 0.9 to 0.99 and finally powder coated in texture seimens gray RAL 7032 & as directed by Engineer-in-Charge comprising of and including following including suitable size and length of copper conductor cable from main panel to APFC panel for connections as approved complete all as specified and directed:- (a) 200 A capacity for pahse and 100 A neutral aluminium bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) MCCB 200 A TP 25 KA TM based O/C and S/C Rel -01 Nos Incomming (c) 6 A FPMCB 10 KA - 01 Nos (d) 10 A TP MCB 10 KA - 02 Nos (e) 20 A TP MCB 10 KA - 01 Nos (f) 25 A TP MCB 10 KA - 03 Nos (g) 63 A TP MCB 10 KA - 02 Nos (h) Power contractor 9.7 kVAR TP cap duty, 230 VAC -3 Nos (j) Power contractor 12.5 kVAR TP cap duty, 230 VAC - 3 Nos (k) Power contractor 25 kVAR TP cap duty, 230 VAC - 2 Nos (l) Auxillary contact - 4NC, 230 VAC - 01 (m) Add on Auxillary contact - 4NC,-01 (n) Add on Auxillary contact - 1 NO+1NC,-01 (n) 8 Step APFC Relay MP based , 230 VAC, 1-CT- 01 (o) Indicating lamps R,Y,B -01 Nos Each (p) A/M Sel Switch , 1P, 2W - 01 Nos (q) A set of heavy duty capacitor, 440 volts. with output steps of 100 KVAR capacity capacitor bank in steps of with 8 steps (2 x 25 KVAR + 3 x 12.5 KVAR + 1 x 7.5 KVAR + 1 x 3 KVAR + 1 x 2 KVAR) in any configuration to accommodate all possible set ups. (r) Rocker switch illiminated type 230 VAC - 08 Nos (s) Fan 12 A 4" - 01 Nos
Supply, installation, testing and commissioning of CPRI approved automatic power factor correction (APFC) panel, outdoor type, with front door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level of capacity 50 KVAR ready to use design confiring to relevant IS rated for short circuit rating of 50 KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 415/ 440 Voils, 3 phase 50 Hz, AC , anti corrosive coating to achieve power factor from 0.9 to 0.99 and finally powder coated in texture seimens gray RAL 7032 & as directed by Engineer-in-Charge comprising of and including following including suitable size and length of copper conductor cable from main panel to APFC panel for connections as approved complete all as specified and directed:- (a) 100 A capacity for pahse and 63 A neutral aluminium bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) MCCB 100 A TP 25 KA TM based O/C and S/C Rel -01 Nos Incomming (c) 6 A FPMCB 10 KA - 01 Nos (d) 10 A TP MCB 10 KA - 02 Nos (e) 20 A TP MCB 10 KA - 01 Nos (f) 25 A TP MCB 10 KA - 03 Nos (g) Power contractor 9.7 kVAR TP cap duty, 230 VAC -3 Nos (j) Power contractor 12.5 kVAR TP cap duty, 230 VAC - 3 Nos (l) Auxillary contact - 4NC, 230 VAC - 01 (m) Add on Auxillary contact - 4NC,-01 (n) Add on Auxillary contact - 1 NO+1NC,-01 (n) 6 Step APFC Relay MP based , 230 VAC, 1-CT- 01 (o) Indicating lamps R,Y,B -01 Nos Each (p) A/M Sel Switch , 1P, 2W - 01 Nos (q) A set of heavy duty capacitor type MPPH box type, 440 volts. with output steps of 50 KVAR capacity capacitor bank in steps of with 6 steps ( 3 x 12.5 KVAR + 1 x 7.5 KVAR + 1 x 3 KVAR + 1 x 2 KVAR) in any configuration to accommodate all possible set ups. (r) Rocker switch illiminated type 230 VAC - 08 Nos (s) Fan 12 A 4" - 01 Nos (t) MCB busbar connector R,Y,B- 06 Nos
Supply, installation, testing and commissioning of CPRI approved automatic power factor correction (APFC) panel, outdoor type, with front door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level of capacity 75 KVAR ready to use design confiring to relevant IS rated for short circuit rating of 50 KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 415/ 440 Voils, 3 phase 50 Hz, AC , anti corrosive coating to achieve power factor from 0.9 to 0.99 and finally powder coated in texture seimens gray RAL 7032 & as directed by Engineer-in-Charge comprising of and including following including suitable size and length of copper conductor cable from main panel to APFC panel for connections as approved complete all as specified and directed:- (a) 160 A capacity for pahse and 100 A neutral aluminium bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) MCCB 160 A TP 25 KA TM based O/C and S/C Rel -01 Nos Incomming (c) 6 A FPMCB 10 KA - 01 Nos (d) 10 A TP MCB 10 KA - 02 Nos (e) 20 A TP MCB 10 KA - 01 Nos (f) 25 A TP MCB 10 KA - 03 Nos (g) 63 A TP MCB 10 KA - 01 Nos (h) Power contractor 9.7 kVAR TP cap duty, 230 VAC -3 Nos (j) Power contractor 12.5 kVAR TP cap duty, 230 VAC - 3 Nos (l) Auxillary contact - 4NC, 230 VAC - 01 (m) Add on Auxillary contact - 4NC,-01 (n) Add on Auxillary contact - 1 NO+1NC,-01 (n) 8 Step APFC Relay MP based , 230 VAC, 1-CT- 01 (o) Indicating lamps R,Y,B -01 Nos Each (p) A/M Sel Switch , 1P, 2W - 01 Nos (q) A set of heavy-duty capacitor type MPPH box type, 440 volts. with output steps of 50 KVAR capacity capacitor bank in steps of with 8 steps ( 01 X 25 kVAR +3 x 12.5 KVAR + 1 x 7.5 KVAR + 1 x 3 KVAR + 1 x 2 KVAR) in any configuration to accommodate all possible set ups. (r) Rocker switch illiminated type 230 VAC - 08 Nos (s) Fan 12 A 4" - 01 Nos (t) MCB busbar connector R,Y,B- 06 Nos
Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 50 Sqmm 3.5 Core, including taking down old, complete, all as specified and directed :-
All as per item no 81 above but 70 Sqmm 3.5 Core
All as per item no 81 above but 95 Sqmm 3.5 Core
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of MCB TP 10 Amp to 63 Amps and current carrying capacity in the DB complete with connection testing and commissioning.
M&L for rewiring of complete APFC panel of any capacity with 2.5 Sqmm of copper wire including all necessary item required on ground to complete the job all as specified and directed by Engr-in-Charge
M&L for repairing to the exisitng APFC panel by removing exisitng busbar, MCCBs, capacitor banks, contactors, MCBs, incoming and outgoing cables and repairing the APFC panel by welding hinges, fixinging nuts and bolts of suitable size, painting complete panel, proper insualation of incoming and outgoing LT cable complete all as specified and directed.
M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge.
Likitha Enterprises
R K Traders
V.Venkata Ramaiah
M/s Bapujee Builders and Traders
R J ENTERPRISES
chauhan syndicate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .