| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 CrAccepted-AOC | ₹35.2 Cr Quoted ₹35.3 Cr | L1 | Accepted-AOC Being Lowest and found reasonable |
| 2 | L2₹35.5 CrRejected-Finance | ₹35.5 Cr | L2 | Rejected-Finance Other than Lowest Bidder |
| 3 | L3₹38.1 CrRejected-Finance SIBAL NIWAS BAGADGANJ POST OFFICE NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | ₹38.1 Cr | L3 | Rejected-Finance Other than Lowest Bidder |
| 4 | L4₹38.8 CrRejected-Finance | ₹38.8 Cr | L4 | Rejected-Finance Other than Lowest Bidder |
| 5 | L5₹40.7 CrRejected-Finance | ₹40.7 Cr | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹27.5 Cr
EMD Value
₹15 L
Closing Date
7 Jun 2022, 6:00 pmClosed
HQ CHIEF ENGINEER BHOPAL ZONE, BHOPAL
HQ CHIEF ENGINEER BHOPAL ZONE, MILITARY ENGINEER SERVICES, SULTANIA INFANTRY LINES, BHOPAL - 462001
CONSTRUCTION OF 05 X MULTICOMPARTMENTS (06 X COMPARTMENTS) EXPLOSIVE STORAGE BLDG AND ALLIED INFRASTRUCTURE AT PULGAON.
2021_MES_494218_1
CEBZ/PUL/TOKEN/12 OF 2021-22
Open Tender
Civil Works
819 days
PULGAON
As per NIT
5 documents required · 5 mandatory
₹3,000
Yes
GARRISON ENGINEER PULGAON
₹15 L
Yes
HQ CHIEF ENGINEER BHOPAL ZONE, BHOPAL
12 Sept 2024
13 Dec 2021
14 Jun 2022
13 Dec 2021
7 Jun 2022
23 May 2022
21 Feb 2022
Amount
Note:-(i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department.
GENERAL SUMMARY
Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule ‘A’ Part- I (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for LIGHTNING PROTECTION as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for FIRE FIGHTING as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part- IX (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part- X (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for RETAINING WALL as listed in Schedule ‘A’ Part- XI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXACAVATION, EARTH WORK & SITE DEVELOPMENT as listed in Schedule ‘A’ Part- XII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for DEMOLITION as listed in Schedule ‘A’ Part- XIII (Ref prepriced schedule attached seperately)
SCH 'A' Pt - XIV (MISCELLANEOUS ITEMS)
INTERNAL ELETRIFICATION NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III (internal Electrification) shall also be applicable.
M&L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in and including medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), in mild steel/pressed steel sunken boxes( with earth dolly) with and including of 03mm thick bakelite, laminated hylem sheet top cover of suitable size for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following:-
One light point controlled by one 5/6 amps one way switch
One fan/ exhaust fan point controlled by one 5/6 amps one way switch & one fan regulator.
One Socket outlet, three/five pin, 5 Amp, controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin on independent board.
One Socket outlet, three/five pin, 5 Amp, controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin on the same board with other switches, sockets, fan regulators, etc.
M&L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper FRLS conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with and including MS/pressed steel sunken box (with earth dolly) with and including 3mm bakelite, laminated hylem sheet top cover of suitable size, including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin amps 15/16 Amp socket outlet independent complete all as specified and directed.
S&F LED tube light wall / ceiling mounting, minimum capacity of 1 x 20W LED batten type with aluminium housing, integrated electronic driver linear, tube light fitting system having lumens with system efficacy > 115 Lm /W at System level (including the driver loss) . The Luminaire should have Cool day light color temp of 6500 K CRI> 80. Life 40,000 burning hours with 70% lumen maintenance . PF > 0.95 Surge protection of > 2 KV the fitting shall be pre-wired including connecting with PVC insulated multi-stranded copper flexible cable of size 0.50 sqmm three core complete all as specified and directed. Notes: 1. Warranty for replacement of each LED shall not be less than 05 years from the date of purchase. 2. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits.
S&F LED lamp 9/10 W, Pin type B 22, 230V AC, 50Hz single phase including bakelite batton holder with all fitting fixing accessories complete all as specified and directed. Note- Warranty for replacement of each LED shall not be less than 05 years from the date of purchase.
S&F LED street light fitting, minimum capacity of 25W, made up of pressure die cast aluminium housing with high efficency LED as lighting source and lens with toughned glass having bottom seperate driver compartment with IP 66 protection and impact resistance of IK 07, etc and all accessories prewired with & including mounting bracket of 40mm bore light grade pipe of required length and shape including bending, forging or welding, etc and suitable bolts, nuts, washeres, etc and connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sqmm, three core from ceiling rose to fitting complete all as specified and directed. Notes: 1. Warranty for replacement of each LED shall not be less than 05 years from the date of purchase. 2. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits.
S&F MCB SPN, 20Amps, 220 volts AC confirming to IS: 13947-3 and IEC-60898 'B' Curve type, breaking capacity 10 kA complete all as specified and directed.
S&F MCB SP, 5 to 30Amps, 220 volts AC confirming to IS: 13947-3 and IEC-60898 'B' Curve type, breaking capacity 10 kA complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover with handle of 8 mm dia bar, charcoal/salt, funnel with wire mesh etc complete all as specified and directed. NOTE :-(i) The concrete pit (to be provided atleast 500mm away from earth pit) shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M.
S&F Flame proof switch socket & plug combined in LM6, 415 volt, 50 Hz, 32 Amps, 3 phase, certified as "Flame proof" by CMRI Dhanbad suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981, degree of protection IP-65 as per IS:2147/81, cable entry top and bottom 3/4" light grey in LM-6 construction complete all as specified and as directed. NOTE: Rate quoted shall be inclusive of brackets made of MS steel of suitable size.
S&F Flame proof 3 way lighting junction box in cast aluminium alloy LM-6, material size 3/4" ET 125mm x 75mm dia with terminal/commectors 6 Nos, 4 Square terminals with flanged cover earthings external 2 Nos & internal 2 Nos 3/4" ET entry, hardware in stainless steel with anti-corrosive epoxy powder coating with protection IP-65, equipment standard as per IS-2148/81 alongwith suitable size flame proof double compression cable glands heavy duty for gas group I/IIA/IIB/IIC approved by CCE and certified by CMRI complete all as specified and as directed. NOTE: Rate quoted shall be inclusive of brackets made of MS steel of suitable size.
S&F Flame proof 4 way lighting junction box in cast aluminium alloy LM-6, material size 3/4" ET 125mm x 75mm dia with terminal/commectors 6 Nos, 4 Square terminals with flanged cover earthings external 2 Nos & internal 2 Nos 3/4" ET entry, hardware in stainless steel with anti-corrosive epoxy powder coating with protection IP-65, equipment standard as per IS-2148/81 alongwith suitable size flame proof double compression cable glands heavy duty for gas group I/IIA/IIB/IIC approved by CCE and certified by CMRI complete all as specified and as directed. NOTE: Rate quoted shall be inclusive of brackets made of MS steel of suitable size.
S&F Flame proof well glass luminarie, 60 W LED lamp, CMRI certified, made up of die cast aluminium with heat resistant toughned glass including connection to junction box complete all as specified and as directed. NOTE: Rate quoted shall be inclusive of brackets made of MS steel of suitable size.
S&F Flame proof distribution board, SPN 8 way (totally enclosed dust & flame proof) of IP-65 protection with & including flame proof MCB SPN 20 A - 1 No, MCB SP 5-30A - 06 Nos, 240/440 volts, AC, 10 kA suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981, degree of protection IP-55 as per IS:2147/81 as powder coating having provision for one nymber of internal & two number of external screws for earthing also having O ring neoprene rubber gasket, hardware in external steel construction having two nos ET 1 to 1/4 ET outgoing cable entry from bottom suitable for 200 amp aluminium bus bar type nad 12 nos 2.5/4 sqmm clip on type all as specified and certified "flame proof" by CMRI complete all as specified and as directed. NOTE: Rate quoted shall be inclusive of brackets made of MS steel of suitable size.
S&F Flame proof distribution board, TPN 4 way (totally enclosed dust & flame proof) of IP-65 protection with & including flame proof MCB TPN 32 A - 1 No, MCB SP 5-30A - 12 Nos suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981, degree of protection IP-55 as per IS:2147/81 as powde coating having provision for one nymber of internal & two number of external screws for earthing also having O ring neoprene rubber gasket, hardware in external steel construction having two nos ET 1 to 1/4 ET outgoing cable entry from bottom side & also having terminals 4 Nos suitable for 200 amp aluminium bus bar type and 12 nos 2.5/4 sqmm clip on type all as specified and certified "flame proof" by CMRI complete all as specified and as directed. NOTE: Rate quoted shall be inclusive of brackets made of MS steel of suitable size.
EXTERNAL WATER SUPPLY--
M&L for cutting existing cast iron pipe (tyton joint) and inserting cast iron tee of size 200mm x 200mm x 150mm flanged including necessary fittings, mechanical & lead joints (as required at site), gaskets, nuts bolts, earth work, etc complete all as per site requriement and all as specified and directed. Note: The cost of earth work, cuting, new CI tee, CI fittings including lead joints, mechanical joints as required at site are deemed to be included in quoted unit rate.
M&L for cutting existing cast iron pipe (tyton joint) and inserting cast iron tee of size 150mm x 150mm x 150mm flanged including necessary fittings, mechanical & lead joints (as required at site), gaskets, nuts bolts, earth work, etc complete all as per site requriement and all as specified and directed. Note: The cost of earth work, cuting, new CI tee, CI fittings including lead joints, mechanical joints as required at site are deemed to be included in quoted unit rate.
Supplying, laying, connecting, jointing and testing ductile iron pressure pipe ISI maked IS-8329-2000 (Reaffiremed - 2005 Edition 4.1 ) of 150 mm bore with socket spigot ends, suitable for "push on joints" in standard working lengths supplied with rubber gasket duly ISI marked for water supply, class K-9 with socket and with cement mortar lining inside the metalic zinc coating with finishing layer of bituminous paint on outer side of the pipe without polythelene sleeves but including "Push on joint" supplied with ISI marked EPDM rubber gasket conforming to IS-5382-1985 (Reaffirmed - 2003) with dual hardness of type -2 (bulb) and type -5 (Heel) quality laid in trenches complete all as specified and directed.
M&L for construction of brick masonary new valve pit chamber of size 1050mm x 750mm x 1000mm (Internal dimension) with 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 20/23cm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mm x 50mm x 6mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed.
Supplying, fixing and testing of DI pipe fittings (specials) heavy duty for any type (flanged/socketed) pipes such as bends (any type radius, and angle), tapers, any type straight bend, increasing,decreasing, or double socket etc) Tee pieces, ring branch, 'Y' junction double branch, Cross (all socket or socket and spigot), collors, caps and plugs, adopters etc of any size radius and lenght confirming to IS 9523/2000 specifications with external bitumen coating and internal cement mortor lining and metalic zinc coating up to 200mm bore complete all as specified & directed.
EXTERNAL ELECTRIC SUPPLY & FIRE FIGHTING
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to test point or main switch board or main control board all as specified and testing on completion including provision of earth strip protection by 40mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover with handle of 8 mm dia bar, charcoal/salt, funnel with wire mesh etc complete all as specified and directed. NOTE :-(i) The concrete pit (to be provided atleast 500mm away from earth pit) shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of 40mm GI pipe light grade for protection of earth strip and 32 x 6 mm GI earth strip upto 7.5 M.
EXTERNAL ELETRIFICATION -
Supplying, installing, testing and commissioning copper wound, step down transformer, indoor type complete with standard fittings, HT, 11 KV, 3 phase, LT, 433 V, 3 Phase, 4 wire with off load tappings on primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 160 KVA. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil upto appropriate level, etc. all as per IS 1180 (Part-I) 2014, energy efficiency level - 2 and all jointing materials connected with electrical system, earthing, etc. complete including PCC platform as per manufacturer design complete all as specified and directed comprising of following accessories: -
Item No. 7.01 Contnd..... (a) One cable box HV side consisting of 3 Nos porcelain terminal points including nuts, bolts and washers with two Nos cable gland suitable for 3 core 95 Sqmm HT UG cable. (b) Suitable cable box LV side for mounting two LV cable consisting of 4 Nos porcelain with brass bushing rods, complete with nuts and washers with two nos cable gland suitable for LT UG cable providing with bimettalic lugs. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with fast fill of dehydrating agent. (e) Explosion vent. (f) Thermometer pocket on tank cover including thermometer. (g) Rating plate and terminal marking plate. (h) Earthing terminal two Nos to tank to faciliate fixing of earth strip (i) Oil level gauge and Oil drain filter valve. (j) Lifting lugs (k) Oil filling hole with cap/plug with connection plate complete. (l) Air relief valve plug (m) Tap changer (n) Detachable rollers - 04 Nos (o) Four Nos wheels with locking arrangement. (p) Under base channel (q) Additional neutral terminal (r) Cooling fins. (s) OTI with MRP.
Supplying, fixing, testing and commissioning HT VCB, indoor type, triple pole 400Amps, system breaking capacity 25KA for 3 seconds, 11KV, totally enclosed extendable pattern with automatic drop down and independent spring charging type, motor operated closing mechanism including motor sutable for operation on 230 volts single phase 50 cycle AC supply system and manually opeating system with 24 Volt DC shunt trip coil with auxillary switches mechanical ON/OFF indicator with protective relays including annunciation panel with alarm/hooter compete of modular design and confirming to IS:13118 of 1991 and IS:3427 of 1997 complete all as specified and also including following items:-
Supplying, installing, testing and commissioning of Automatic Power Factor Correction (APFC) Panel complete with power capacitor bank for power factor improvement, three phase, 440V and 50 HZ system, MD XL type super heavy duty suitable for non liner load upto 25% including controlling switch fuse TP housed in sheet metal enclosure of size 2mm thick CRCA sheet with locking arrangement including painting with powder coated paint including copper busbar, digital KVAR, indicator, volt meter, ammeter, contactor, suitable relays, fuse unit, bush button etc alongwith auto and manual control switch with MCCB of suitable capacity as incommer of capacity 50 KVAR complete all as specified and also including following items:-
Design, supplying, installing, testing and commissioning LT power distribution panel board, Indoor, double door IP - 54 type panel board factory fabricated cubical type weather vermin proof with locking arrangement and made out of MS CRCA sheet 2.0 mm thick, ISMC 75 x 40mm for base complete with 600 Amps rated aluminium bus bar 4 strip naturally cooled inside sepreate chamber and compartmentalised cabinet for housing and mounting MCCBs, metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixing an angle iron frame which is made out of 50 x 50 x 6 mm thick angle iron duly marked the incoming &all outgoing controls and comprising with the following duly CPRI Approved:-
Design, supplying, installing, testing and commissioning LT Power distribution panel board, outdoor type, double door IP - 65 type panel board factory fabricated cubical type weather vermin proof with locking arrangement and made out of MS CRCA sheet 3.15 mm thick, ISMC 75 x 40mm for base complete with 200 Amps rated aluminium bus bar 4 strip naturally cooled inside sepreate chamber and compartmentalised cabinet for housing and mounting MCCBs, metering eqpt prewired with suitble size of copper conductor and duly powder coated and panel board fixing an angle iron frame which is made out of 50 x 50 x 6 mm thick angle iron duly marked the incoming &all outgoing controls and comprising with the following duly CPRI Approved:-
M&L for Adopter Panel of suitable size with three Nos of Copper bus bars of suitable size with HT mounting insulator complete for connecting existing HT VCB with proposed VCB complete all as specified and directed.
LIGHTNING PROTECTION
M&L for Earthing complete with copper earth plate electrode 300 x 300 x 3 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to copper earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to earthing test point or main switch board or main control board and testing on completion including provision of earth strip protection by 40mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover with handle of 8 mm dia bar, charcoal/salt, funnel with wire mesh etc complete all as specified and directed. NOTE :-(i) The concrete pit (to be provided atleast 500mm away from earth pit) shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of 40mm GI pipe light grade for protection of earth strip and 32 x 6 mm copper earth strip upto 7.5 M.
FIRE FIGHTING
S&F MS flanged pipe 200mm NB, heavy duty for multi-storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chrom primer complete all as specified and directed.
S&F MS flanged pipe 100mm NB, heavy duty for multi-storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chrom primer complete all as specified and directed.
S&F Cast Iron Foot Valve conforming to IS 4038, 200 mm NB complete all as specified and directed.
S&F Cast Iron Foot Valve conforming to IS 4038, 100 mm NB complete all as specified and directed.
S&F MS cabinet (approx size 750mm x 600mm x 450mm) to enclose fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement duly painted with 2 coats of synthetic enamel paint over coat of zinc chrom primer and mounted on masonry platform complete all as specified and directed.
S&F fire hydrant landing valve type-B (double head outlet) of 63mm dia conforiming to IS 5290 complete all as specified and directed.
S&F gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet with all accessories complete all as specified and directed.
Supply, install and testing Star delta Starter fully automatic suitable for 415 V, 50HZ, with ML-6 contactor with suitable relay range 66-140 Amps with timer 9-30 sec SPP including incomming and outgoing electric connnection complete all as specified and as directed.
Supply, install and testing of DOL Starter fully automatic suitable for 415 V, AC, 50HZ suitable for 6-10 Amps rating including incoming and outgoing electric connection complete all as specified and as directed.
M&L for construction of brick masonry valve chamber of size 1050mm x 750mm x 1000mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 230 mm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces with & including excavation earth work in any type of soil, MS sheet cover 3.15mm thick fixed with angel iron frame 50x50x6mm with locking arrangement embedded in PCC and painting ot MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed.
SEWAGE DISPOSAL NOTE:- For items of Sewage Disposal notes given at the beginning of Sch ‘A’ Part-X (SEWAGE DISPOSAL) shall also be applicable.
S&F 1000mm dia, 2.5mtr long, RCC Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc. complete for 10 users complete all as specified and directed.
S&F soakage well with & including excavation in any type of soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25 / SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 m dia x 3.0 m effective depth complete all as specified and directed.
Supply only termite treated FRG Dunnage of size 30cm x 30cm x 20cm complete all as specified and directed.
SIBAL AND SIBAL
Parth Infrastructure Pvt. Ltd.
M/s. Vijay Construction
Beejay Associates Contracts Pvt Ltd
Roshan Lal Talwar
M/S JAI BHAWANI CONSTRUCTIONS
R K BUILDER
Bidder Name
R K BUILDER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid