| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.3 Cr+₹1.6 L (0.69%)Rejected-AOC | ₹2.3 Cr+₹1.6 L (0.69%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.4 Cr+₹3.6 L (1.56%)Rejected-AOC S O LT MANINDRA BASUMATARY VILL P O BANARGAON P S DOTMA DIST KOKRAJHAR BTC ASSAM | BANARGAON | KOKRAJHAR | ASSAM | ₹2.4 Cr+₹3.6 L (1.56%) | L3 | Rejected-AOC L3 |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
24 Feb 2020, 2:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Renovation of existing Lavatory Block of Ground Floor, First Floor and Second Floor including basement Renovation, Store Room and Renewing of Kitchen Room etc. at Bodoland Guest House at Kailash Colony A-29, New Delhi for the financial year 2020-21.
2020_BTC_16449_1
27/KOJ/IFB/2016-17/PT-I/20
Open Tender
Civil Works - Building
Item Rate
365 days
Kailash Colony, New Delhi
Refer to SBD
6 documents required · 6 mandatory
₹7,000
Principal Secretary, BTC, Kokrajhar
₹4.6 L
Yes
5 Mar 2020
13 Feb 2020
24 Feb 2020
13 Feb 2020
24 Feb 2020
13 Feb 2020
13 Feb 2020 - 24 Feb 2020
Amount
15.23 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.1 For thickness of tiles 10mm to 25mm.
15.25 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
15.40 Dismantling precast concrete or ctone slabs in walls, partitions walls etc. including stacking within 50 metres lead.
15.4 Demolishing R.B. work manually by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
15.44 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge: 15.44.1 15mm to 40mm nominal bore
15.56 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
15.60 Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50m initial lead, for all leads including all lifts involved.
17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.3.1 W.C. pan with ISI marked white solid plastic seat lid
17.4 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal of 430 X 260 X 350mm and 340 X 410 X 265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors, wherever required: 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
17.7 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:
17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
17.16 A Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer-in-charge.
17.22 B Providing and fixing CP Brass Single lever telephonic wall mixer of qulity & make as approved by the Engineer-in-Charge.
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.1 Semi rigid pipe 17.28.1.2 40mm dia.
17.32 Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing: 17.32.1 Circular shape 450mm dia.
17.32.4 Rectangular shape 1500 X 450mm
17.34 Providing and fixing toilet paper holder: 17.34.1 C.P. brass
17.35 Providing and fixing soil, waste and vent pipes: 17.35.1 100mm dia. 17.35.1.1 Sand cast iron S&S pipe as per IS; 1729
17.38.1.1 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, boltsand nuts complete. 100mm dia.
17.441.2 Providing and fixing single equial plain junction of required degree: 100 X 100 X 100mm Sand cast iron S&S as per IS-1729 Sand cast S&S as per IS-3989
17.59.1 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of dia,eter.
18.8.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge: Concealed work, including cutting chases and making good the walls etc. 15mm nominal outer dia. pipes
18.8.3 25mm nominal outer dia. Pipes
18.50.1 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15mm nominal bore
18.52.1 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS; 8931. 15mm nominal bore.
18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931: 15mm nominal bore
17.10.11 Providing and fixing Stainless steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board
22.5 Providing and laying water proofing treatment in sunken portion of WC's bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. this layer will be allowed to air cut for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry).
22.23A Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @ 14.35kg/ 10 sqm. One coat of self priming of cementatious waterproofing polymer (dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-charge.
9.6.1 Providing and fixing 35mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part-B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-in-charge and panelling with panels of: (note:- Butt hinges and necessary screws shall be paid separately) 12mm thick plain grade - 1 medium density flat pressed three layer particle board FPT-1 or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848:
9.46.3 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc. wherever necessary complete.
9.88 Providing and fixing chromium plated brass 100mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
97.3 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to reqired colour of shade with necessary screws etc. complete:
APWD SOR(7.8.2) Providing, fitting and fixing in position 62mm thcik double skin partion with well seasoned Sal/Bonsum/Sundi/Hollock frame in size 75mm X 38mm and internal frame of 50mm X 38mm and fixing on both sides 8mm thick flat pressed melamine faced pre-laminated baggage board medium density fibre boards (MDF) bonded with phenol formaldehyde synthetic resin of approved shade as specified and directed at all levels. (a) With Bajaj- exterior grade (one side decorative) (i) 8mm thick
11.46.2 Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacture) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigment etc. complete.
11.23.1 Marble stone flooring with 18mm thcik marble stone as per sample of marble shall be approved by Engineer-in-charge over 20mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with: Makrana white second quality.
12.58.1 8mm thick fully enforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225kg/ Sq. cm. bending strength 100kg/sq. cm, of size 595 X 595 mm, having perforation of dia. 10mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50mm thick rockwool of 48kg/cum backing.
6.3.3(WS)/APWD Supplying fitting fixing iron removal filter filling treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of TARUS make with all necessary fittings such as valve, bib cock, pipe connection etc. with a free maintanance period of six months (IV) 500 liters capacity.
11.20.1 Chequerred precast cement concrete tiles 22mm thick foothpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand). Light shade using white cement.
11.5.3 (APWED SOR) Providing , fitting and fixing anodised aluminium framed sliding glazed doors with partitions walls with anodised aluminium frames made of 100mm X 43mm X 2mm sections of approved brand with door style of size 81mm X 43mm X 2mm, top rails 46mm X 43mm X 2mm, lock rails 81mm X 43mm X 2mm, paints and 12mm prelaminated board fittings with glazing clip, special type rubber gasket complete including roller , door handle, lock angle, cleat etc.complete as directed by the department at all levels. (i) Partly 6mm thcik coloured reflectory glass and partly with perlaminated board.
13.41.1 Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade.New work (two or more coats) over and including water thinable priming coat with cement primer.
13.45.1 Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10sqm) over and including priming coats of exterior primer applied @ 2.20kg/10sqm.
13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufactures specification: Two or more coats applied on walls @ 1.25 ltr/ 10 sqm. Over and including one coats of special primer applied @ 0.75 ltr/10Sqm
(5 seater) Sofa set.
Wooden Chair armless
Dinong Table (6 Seater) Wooden
Wooden Bed (Delux Size) with Teak/Sisu
Mattress double (Kurlon 6 X 6.5 X 4)
Steel almirah (78" X 36" X 6")
Aqua Guard Filter
ELECTRICAL ITEMS: 2.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kable/Nicco/Anchor or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2 mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/AKG/Precision/Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked)with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.2 Medium point up to 6.00 metre Length.
2.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kable/Nicco/Anchor or equivalent make as approved by the Deptt.) in surface/recessed conduit wiring system with 20mm dia 2 mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/AKG/Precision/Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) including 6 Amp flush type switch/bell push(Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked)with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.3 Long point up to 10.00 metre Length.
2.2 Wiring to 5 a pin 6 Amps plug point with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/ RR Kable or equivalent make as approved by the Deptt.) in surface/recessed 2 mm thick/heavy rigid ISI marked IS: 9537 Part - III rigid PVC conduit (Berlia/AKG/Precision /Presto Plast/polycab/MW or equivalent makes as approved by the Deptt.) wiring system including 5 pin 6 Amp flush type plug socket and 6 Amps F/T switch (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 2.2.3 Long point up to 10.00 metre Length.
2.4 Wiring for 5/6 pin 16 Amp power plug point with 4 mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR kable/Nicco/Anchor or equivalent make as approved by deptt.) in surface/recessed conduit wiring system including and fixing 5/6 pin 16Amps flash type socket outlets and 16Amps flash type switch (Anchor penta/gold medal/Kolor Kany.Kom/Havells or equivalent make as approved by Deptt./Havells make), G.I/ M.S. switch board (I.S.I. mark with phadelite laminated sheet cover earth continuity with 2.5 mm cable to the 3rd pin of the socket as required complete with 20mm dia. 2 mm thick/heavy ISI marked IS : 9537 part-III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the dept.) 2.4.3 Extra long point up to 25.00 mtr Length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.1 With 2 X 2.5 sq.mm + earth continuity with 1 X 2.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.2 With 2 X 4 sq.mm + earth continuity with 1 X 2.5 sq.mm cable in 20mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. 2.7.3 With 2 X 6 sq.mm + earth continuity with 1 X 4 sq.mm cable in 25 mm dia . 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.9 Wiring for drawing sub-main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kable or equivalent make as approved by the Deptt.) in surface/recessed PVC 20mm dia. 2mm thick/heavy ISI marked IS:9537PART- III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/M.W or equivalent make as approved by the deptt.) Wiring system. 2.9.4 With 4 X 10 sq.mm + earth continuity with 2 X 6 sq.mm cable in 40 mm dia 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G. 25 cm long cast back plate and brass lamp holder complete including connection as approved by the deptt. As required without Lamp.
15.4 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door IP-43 surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grounting nuts & bolts as required. complete with making necessary connection as approved and specified as directed by the department. 15.4.1 Schneider neo break, C & S, Havells,INDOASIAN, HPL or equivalent as approved by the deptt.) make 15.4.1.3 8 way SPN double door
15.8 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 ABB, Schneider MG, legrand, Hager make) 15.8.1.2 6 way TPN (4+18) double door.
14.2 Supplying fitting and fixing industrial plug & socket in durface mounting TPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link earth bar of the following rating of 4P MCB complete with making necessary connection etc. as specified and directed by the deptt. 14.2.1 (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the deptt.) 14.2.1.2 30/32A capacity
16.2 supplying with fitting and fixing SPN 10 KA 240/415v 50 Hz MCB of the following capacity complete with making neoessary connection as approved, specified and directed by deptt. 16.2.1 B Series (Schneider MG, legrand, Hager make) 16.2.1.1 B 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.3 D Series (ABB, Schneider MG, Legrand, Hager make) 16.3.3.2 40A
16.6 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.6.3 D series (ABB, Schneider MG, legrand, Hager make) 16.6.1.3 63A
16.7 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.7.1 30mA Sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 16.7.1.2 40A
16.7 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.7.1 30mA Sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 16.7.1.4 80A
16.8 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.8.2 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.8.2.3 63A
16.8 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.8.2 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 16.8.2.4 80A
16.16 Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50 Hz 4P MCCB (Ics= ICU, adjustable Iron setting 0.7) (without enclosure) of the following capacity complete with main necessary connection as approved, specified and directed by the deptt. 16.16.1 25KA 415V 50Hz 4P MCCB (Schneider, Legrand, Siemens, Indo Asian, Hager make) 16.16.1.4 63A
16.17 Supplying with fitting and fixing panel mounting open execution 35/36 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Iron setting 0.7) (Without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.17.1 35/36 KA 415v 50Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 16.17.1.3 315A
16.44 Supplying with fitting and fixing Four Pole 415V front handle operated on load Change over Switch (IP-20 Peotection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.44.1 C&S Havelles, Indo Asiamn, HPL. GECO Make 16.44.1.6 400A
Supplying, installation, connection, testing and commission of the following indor decorative recessesd typed LED down lighter luminaries complete with all accessories including driver in the false ceiling type Armstong/Gypsum or similar ceiling mounting with necessary support and connection with 1.5 sq. mm. PVC insulated S.C> copper conductor as required and as directed by the department. (600 X 600 module) 13.1 Philips model RC 380 B LED-25-6500/4000 PSE OD WH Luminaries down lighter with latest LED technology or rquivalent as approved by the deptt.
Supplying, installation, connection, testing and commission of the LED surface downlight lumineries complete with all arrangement and connection with 1.5 sq.mm PVC insulated SC copper conductor as required and as directed by the department. 13.1. Philips model DN 170C LED IOS-6500/4000/3000 PSU WH 15W or equivalent as approved by the department.
Supplying, installation, connection, testing and commission of the following surface/suspended twin LED luminarious complete with all acessories driver in the ceiling/wall by providing necessary mounting bracket etc. and necessary. Connection with 1.5 sq.mm PVC insulated S.C> copper conductor as required and as directed by the dept. 16.1 Philips 40 model BN 208 C LED 40/(DL/CDL/NW) L 1200 FR or equivalent as approved by the deptt. (Twin 1200mm)
Supplying, installation, testing and commission of the following LED lames as directed by the deptt. 12.25 Philips LED bulbs non-dimmable 7W or equivalent as approved by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the deptt.) as required complete and as directed by the department [Without regulator] 27.1.3 Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. Havells make)
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1 Domestic 27.2.1.2 Power Flow 225mm sweep (ORIENT make)
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweep with making necessary connection as approved by the Deptt.) as required complete and as directed by the Deptt. 27.2.1.7 Heavy Duty 450mm sweep 900 RPM Single phase (ORIENT make)
ECBC 2.1 Supplying and fitting fixing of Electric storage water heater [Geyser] of Bajaj/Crompton/Racold/V. Guard or equivalent make including necessary connection cable, as approved by the deptt.) etc. as required complete and as directed by the deptt. ECBC. 2.1.1 Vertical type: ECBC 2.1.1.4 25.00 litres, capacity (5 star model) (Crompton/Racold/V. Guard or equivalent make)
39.7 Supplying including installation, connection as approved by the Deptt. testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase)with steel cable rope and submersible cable complete as directed and specified by the Deptt. 39.7.4 Three phase Submersible motor pump set (Texmo/Crompton Greaves/Aquatic /CRI/V-Guar suitable for 100mm bore well and above 3HP STAGE 7 to 40 with MCB controlled Submersible motor pump set control panel.
30.5 Supplying, fitting and fixing of single Phase fan Motor of 1.00 Ton to 2.00 Ton capacity Split type Air Conditioner machine.
30.8 Gas Charging of split type A.C. with F-22 fresh refrigerant 30.89.2 1.50 Ton capacity
30.11 Supplying with fitting and fixing single phase D.O.L starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 30.11.2 Overload Realy Range 6.0-9.3 Amps for 3.7 KW
30.15 Dismantling & shifting of existing A.C. Machine 30.15.2 1.50 Ton capacity
30.16 Painting A.C. outdoor unit Split type machine 30.16.2 1.50 Ton Capacity
31.1 Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND/Vee-Dee/V GUARD/VERTEX/INDO/VENUS make. 31.1.7 4.0 KVA Automatic input 90-280 V out put 200-240V
29.9 Supplying with fitting and fixing of Angle iron framing made 50 mm X 50mm X 5mm size angle iron for accommodation of 1.00 Ton to 2.00 Ton Windows/split type A.C> machine
Supplying with fitting fixing SONY make-42" Android Smart LED TV. (Rate as Company Price List)
Supplying and fitting fixing of kitchen Chimney with all accessories including making necessary connection as approved and specified by the deptt. (KUTCHINA/ALIEN/FLEY Make).
ECBC 7.3 Supplying with installation testing and commissioning of Hi- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and elevtrical connection cable, as approved by the deptt.) up to 5m between the room unit and out door unit as directed by the deptt. ECBC 7.3.1 1.5 Ton capacity ECBC 7.3.1.7 Mitsubishi make Heavy duty Hybrid AC Model SRK 52 HE- 2 Heating+ COOLING
Mwikwm Basumatary
DHANANJAY BASUMATARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .