Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹39.0 L+₹1.5 L (3.91%)Rejected-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹46.4 L+₹8.9 L (23.7%)Rejected-Finance | L3 | Rejected-Finance Rejected due to bidder not L1 | |
| 4 | L4₹46.8 L+₹9.2 L (24.6%)Rejected-Finance | L4 | Rejected-Finance Rejected due to bidder not L1 | |
| 5 | L5₹47.2 L+₹9.6 L (25.6%)Rejected-Finance | L5 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Apr 2020, 6:00 pmClosed
GE 865 EWS
GE 865 EWS
REPAIR MAINT OF DG SETS AND CONNECTED WORK AT SECTOR B UNDER GE 865 EWS AT LEH
2020_MES_330250_2
865/EWS-125/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per NIT
7 documents required · 7 mandatory
₹500
GE 865 EWS
₹80,000
Yes
24 Apr 2020
28 Mar 2020
6 Apr 2020
28 Mar 2020
4 Apr 2020
30 Mar 2020
Amount
Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comprising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Eng. In .Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tension properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE (1) Cost of Spare parts required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (3) Make of spare recommendation by auth service centre of manufacturer (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 125 KVA DG set
(l) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(o) 40 KVA DG set
(p) 35 KVA DG set
(q) 25 KVA DG Set
M & L for changing /toping up of best quality of engine oil 20W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed Make:-castrol/veedol/valoline
Replacement of Oil filter element as per existing for following capacity DG Sets complete all as specified and directed by Engr-in-Charge. Make- Kirloskar/Mico/TVS/Cummins/Freaves (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 125 KVA DG set
(l) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(o) 40 KVA DG set
(p) 35 KVA DG set
(o) 25 KVA DG Set
Replacement of Air cleaner element (inner and outer) suitable for following capacity DG Sets complete all as specified and directed by Engr-in-Charge. Make Kirloskar/Cummins/Greaves (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 125 KVA DG set
(l) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(o) 40 KVA DG set
(p) 35 KVA DG set
(o) 25 KVA DG Set
Replacement of Fuel filter elements(primary & secondery) for following capacity DG Sets complete all as specified and directed by Engr-in-Charge. Make Kirloskar/Cummins/Greaves (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 125 KVA DG set
(l) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(o) 40 KVA DG set
(p) 35 KVA DG set
(o) 25 KVA DG Set
Replacement of 'V' belt for water pump suitable for following capacity DG Sets complete all as specified and directed by Engr-in-Charge. Make Kirloskar/Cummins/Greaves (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 125 KVA DG set
(l) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(o) 40 KVA DG set
(p) 35 KVA DG set
(o) 25 KVA DG Set
Replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Cummins/Greaves (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 125 KVA DG set
(l) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(o) 40 KVA DG set
(p) 35 KVA DG set
(o) 25 KVA DG Set
Repair and replacement of Dynamo/Alternator Assy for following capacity DG Set complete all as specified and directed by Engr-in-Charge. Make Kirlosker/ cummins/Greaves (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 100 KVA DG set
(l) 82.5 KVA DG set
(m) 62.5/63 KVA DG set
S&F replacement of auotmatic voltage regulator(AVR) 24 volt all as specified and directed by Engr in Charge. Make: Cummins/Kirloskar/Sudhir (a) 500 KVA DG Set
(b) 400 KVA DG Set
(c) 380 KVA DG Set
(d) 320 KVA DG Set
(e) 250 KVA DG Set
(f) 125 KVA DG set
(g) 100 KVA DG set
(h) 62.5/63 KVA DG set
(j) 25 KVA DG Set
Supply and replacement of self starter for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 100 KVA DG set
(k) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(o) 25 KVA DG Set
Replacement of water pump assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 400 KVA DG Set
(d) 380 KVA DG Set
(e) 320 KVA DG Set
(f) 250 KVA DG Set
(g) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
Replacement of Turbo charger assy.for following capacity DG sets make cummins complete all as specified and directed by Engr-in-Charge. (a) 400 KVA DG Set
(b) 63 KVA DG Set
Replacement of Fan Hub assembely for following capacity DG set make cummins/Kirloskar/Greaves complete all as specified and directed by Engr-in-Charge. (a) 400/380 KVA DG set
(a) 250 KVA DG set
Strip opening of alternator of following Capacity DG Sets, removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator. (a) 1010 KVA DG Set
(b) 400 KVA DG set
(c) 380 KVA DG set
(d) 100 KVA DG set
(e) 82.5/63 KVA DG set
Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
Supply and Replacement of lub oil pump suitable for following Capacity DG Sets,make :Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. (a) 500 KVA DG Set
(b) 400 KVA DG Set
(c) 380 KVA DG set
(d) 250 KVA DG set
(e) 100 KVA DG set
(f) 82.5/63 KVA DG set
Supply and Replacement of thermostate valve suitable for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge. (c) 400/380 KVA DG set
(c) 250 KVA DG set
(c) 63/82.5 KVA DG set
Supply and Replacement of Oil seal front and rearsuitable side for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge. (a) 1010 KVA DG Set
(b) 750 KVA DG Set
(c) 400 KVA DG Set
(d) 380 KVA DG Set
(e) 82.5/63 KVA DG Set
Supplyand fix in Replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging.Make- Exide/Ameron.
M & L for Calibration of Injector unit including supply & fixing in replacement O-Ring, Pin roll, barrel, Pin spring, washer and testing complete all as specified and as directed for 25 KVA DG to 1010 KVA Set. Type TBD-2V6
M & L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing complete all as specified and as directed for 1010 KVA DG Set. Type TBD-2V6
M & L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing complete all as specified and as directed for 25 to 750 KVA DG Set. Type TBD-2V6
M & L cleaning of radiator for following capacity DG sets by using Keroscene oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/brazing and Re-assembling after painting of the same complete all as directed. (a) 1010 KVA DG Sets
(b) 750 KVA DG Set
(c) 500 KVA DG Set
(d) 400 KVA DG Set
(e) 380 KVA DG Set
(f) 320 KVA DG Set
(g) 250 KVA DG Set
(h) 200 KVA DG Set
(j) 160 KVA DG Set
(k) 125 KVA DG set
(l) 100 KVA DG set
(m) 82.5 KVA DG set
(n) 62.5/63 KVA DG set
(p) 35 KVA DG set
(o) 25 KVA DG Set
Supply and Replacement of battry terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
Supply and fixing battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete.
M&L for supply and fixing in replacement of Crank wheel suitable for 400/380 KVA DG set of Make: Kirloskar/Cummins all as specified and directed by Engr-In-Charge
Supply and topping uo of best quality antifreezing ,inhabitor (Coolant) liquid for DG Set of various capacity and locations complete all as specified and directed. Make- Castrol/Veedol/Valoline
M&L for supply and fixing in replacement of Crank wheel suitable for 100 to 380 KVA DG set of Make: Kirloskar/Cummins all as specified and directed by Engr-In-Charge
Hitech Erectors Pvt. Ltd.
M/S STANZIN NOBROO
M/S AMCO INDUSTRIES AND EXPORT CORPORATION
M/S LOBZANG NORBOO
H R CONSTRUCTION
Mehar Enterprises
M/S SHAMSHER ALI SUFI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .