Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
17 May 2021, 2:00 pmClosed
DGM JKPCC Ltd Unit Electric Srinagar
DGM JKPCC Ltd Unit Electric Srinagar
Balance Electrical works of DCs Residence at Kulgam
2021_PWDJK_123141_1
01/DGM/Electric/JKPCC/K of 2021-22
Open Tender
Electrical Works
Item Rate
90 days
Kulgam
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
FC JKPCC Ltd a/c
Yes
25 May 2021
26 Apr 2021
18 May 2021
26 Apr 2021
17 May 2021
26 Apr 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
2 way 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100mm X 75mm)
4 Module (125mm X 75mm)
6 Module (200mm X 75mm)
8 Module (125mm X 125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 300 mm sweep
Supply of Ceiling fans (crompton greaves High Breez or approved equivalent) complete with double ball bearig, motorbearing, r, blades,down-rod complete for operation on 230V 50HZ 1-phase A.C supply complete as required
1200mm sweep
Supply,testing & commissioning of 900 RPM 300mm Exhaust Fan suitable for single phase 230v 50HZ AC supply Complete with motor louvers,shutters etc complete as required
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar,neutral link, earth bar, din bar, detachable gland plate interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating,2pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.
Surface mounting LED luminaire wattage shall be 18W or close to 18W complete in everyway with accessories. Complete technical detail shall be furnished in data sheet (comercial fitting)
wall mounting LED luminaire wattage shall be 15W or close to 15W complete in everyway with accessories. Complete technical detail shall be furnished in data sheet.(commercial fitting)
wall mounting LED luminaire wattage shall be 10W or close to 10W complete in everyway with accessories. Complete technical detail shall be furnished in data sheet.(commercial fitting) as mirror light
Supply,erection, testing & commissioning of PDB. This will be floor mounted, free standing, indoor duty, dust & vermin proof, front operated, having front hinged lockable doors, and will be complete with the main and auxiliaries bus bars, interconnection, earth terminals, earth bus and will be powder coated finished with 70 micron. The PDB panel shall use all for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panels will be made as per detailed specifications and drawings forming part of this document. The incoming and outgoing for PDB shall be as follows:
One set of TPN, Al. bus bar rated150 Amps (after considering necessary deratings of 75%) for phases and neutral for half capacity of phases.
The outgoings feeders are as under
2nos 63 Amps DP MCB. 3 no 40 Amps DP MCB
1 set of complete wiring
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface/in ground as required.
upto 50 sq. mm
Supply of multi core, stranded / solid aluminum conductor, XLPE / PVC insulated armoured, PVC outter sheathed 1100V, grade cables of the following sizes. ( Cable shall be suitable for -15ºC to + 50ºC temprature condition )
3.5c * 50sqmm Al, XLPE, arm
3.5c * 35sqmm Al, XLPE, arm
MICRO ENGINEERS
M/S Tioba Electrical Seadat
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .