Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 46 S P MUKHERJEE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹10.0 L | L1 | Accepted-AOC AOC_issued |
| 2 | L2₹11 LRejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | ₹11 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹11.0 LRejected-Finance | ₹11.0 L | L3 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | C. CHOWDHURY AND CO L1 | Electromech Engineers Co-Operative Society Ltd. L2 | RIDHI SIDHI ELECTRICAL L3 |
|---|---|---|---|---|---|---|
| 1.00 | S & F of lead acid dry cell SMF batteries of ratting 12 V, 75 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections with 6 sqmm copper wire, and Submission of test certificate and warranty cards. | 1 | Each | 6,133 ₹6,133 | 9,500 ₹9,500 | 8,000 ₹8,000 |
| 2.00 | S & F of lead acid dry cell SMF batteries of ratting 12 V, 88 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections with 10 sqmm copper wire, and Submission of test certificate and warranty cards. | 32 | Each | 6,133 ₹2.0 L | 9,500 ₹3.0 L | 9,600 ₹3.1 L |
| 3.00 | S & F of lead acid dry cell SMF batteries of ratting 12 V, 100 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections with 10 sqmm copper wire, and Submission of test certificate and warranty cards. | 32 | Each | 6,780 ₹2.2 L | 10,500 ₹3.4 L | 10,600 ₹3.4 L |
| 4.00 | Commissioning of existing UPS after replacing old batteries with new batteries online/No Load with main supply as per direction of EIC. | 3 | Item | 10,000 ₹30,000 | 7,000 ₹21,000 | 5,000 ₹15,000 |
| 5.00 | Dismantling the existing batteries from UPS rack after disconnecting all the batteries and carry the dismantled materials to section store. | 3 | Item | 10,000 ₹30,000 | 1,500 ₹4,500 | 2,000 ₹6,000 |
| 6.00 | Supply & installation of SMF FR battery of capacity---65AH, 12V (Make--- Amaron, Model ----- MED VRLA)
(Rate shall be quoted including buy back of existing batteries as per present condition) | 85 | Nos. | 6,133 ₹5.2 L | 5,000 ₹4.3 L | 5,000 ₹4.3 L |
| 7.00Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 02 years from the date of completion of work) (Rate should be quotated including all taxes and duties) | ||||||
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
16 Jul 2022, 1:00 pmClosed
EE II KNHED PW Dte
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
Strengthening of power back up system by replacement of old Inverter and battery installed at different buildings of Kolkata Medical College Hospital SF of battery at critical card units
2022_PWDE_386624_1
WBPWD/EE-II/KNHED/NIQ-28/22-23
Open Tender
ELECTRICAL WORKS ORG
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹16,000
6 May 2026
23 Jun 2022
18 Jul 2022
27 Jun 2022
16 Jul 2022
27 Jun 2022
Amount
S & F of lead acid dry cell SMF batteries of ratting 12 V, 75 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections with 6 sqmm copper wire, and Submission of test certificate and warranty cards.
S & F of lead acid dry cell SMF batteries of ratting 12 V, 88 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections with 10 sqmm copper wire, and Submission of test certificate and warranty cards.
S & F of lead acid dry cell SMF batteries of ratting 12 V, 100 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections with 10 sqmm copper wire, and Submission of test certificate and warranty cards.
Commissioning of existing UPS after replacing old batteries with new batteries online/No Load with main supply as per direction of EIC.
Dismantling the existing batteries from UPS rack after disconnecting all the batteries and carry the dismantled materials to section store.
Supply & installation of SMF FR battery of capacity---65AH, 12V (Make--- Amaron, Model ----- MED VRLA) (Rate shall be quoted including buy back of existing batteries as per present condition)
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 02 years from the date of completion of work) (Rate should be quotated including all taxes and duties)
Electromech Engineers Co-Operative Society Ltd.
RIDHI SIDHI ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_756231.xls
BOQ • 0.25 MB
2911_.pdf
Tender Documents • 0.50 MB
suspension.pdf