Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical H NO 119 PO GOPINATH NAGAR PS PALTAN BAZAR GUWAHATI 781016 ASSAM INDIA | KAMRUP METRO | ASSAM | 781016 | Accepted-Technical TECHNICALLY QUALIFIED |
| 2 | Accepted-Technical | Accepted-Technical TECHNICALLY QUALIFIED |
| 3 | Rejected-Technical | Rejected-Technical Technically Non-responsive |
Tender Value
₹3 Cr
EMD Value
₹6 L
Closing Date
13 Apr 2026, 2:00 pmClosed
CEO GMDA
Office of GMDA Guwahati
Re-Construction of Pragjyotishpur Kala Parisad North Guwahati
2026_GMDA_52095_1
GMDA/DEV/26/2026/04
Open Tender
Civil Works
Works
Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,000
₹6 L
Yes
2 Jun 2026
16 Mar 2026
13 Apr 2026
16 Mar 2026
13 Apr 2026
27 Mar 2026
17 Mar 2026 - 25 Mar 2026
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:. Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
Providing & fixing in position Phenol bonded Bamboowood flooring with planks of sizes 14mm thick, minimum 1800mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge. Size of Tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) Second class teak wood. 35 mm thick shutters
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood. 35 mm thick
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Varnishing with varnish of approved brand and manufacture : Two or more coats glue sizing with spar varnish or an under coat of flatting varnish
Supplying and fixing of Oxidised mild steel tower bolt (barrel type) 200x10 mm
Supplying and fixing of Anodised Aluminium handles 125 mm with plate 175 x 32 mm
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Hot finished welded type tubes(20kg/sqm) complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : Natural colour insulating board 12 mm thick
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. Kiln seasoned and chemically treated hollock wood
WOODEN GROOVED ACOUSTICAL PANEL FOR WALL Providing & Fixing on (Acoustical Wooden wall paneling): P/F Wooden Slats panels with lineal perforations.The Panels shall be fire reistant grade with melamine laminate panels 2430mm X128mmX16mmwith2mm Slats at 16 mm pitch,Toungune and groove edges for seamless mounting having density of 800kg/m3 GI Framework with Screw fixed horizontal /vertical to wall at every 600mmc/c with centre & edge bracket in tongue& groove system on CC18 framework. The cavity of framework should be inserted with glasswool/polyster fibre equivalent to 48kg/cu.mt glasswool , and along with all assessories. The panelling should be properly done in proper alignment and level as per satisfaction engineer in charge all com
Stretch Fabric Panels for Walls Pannelling Specifications: P/F STRETCHED FABRIC ACOUSTICAL PANEL A on the side walls of auditorium using : GI framework of 48 mm GI studs using 0.55 mm thick and stud channels at 610mmX610mm 0.5 mm thick, fixed with MS angle cleats 1220X610 mm centers to the wall by using metal fasteners, backed with 22SWGX12.5m GI chicken wire mesh with air gap minimum of 50 mm on the back side, as per detailed drawing.The framework to be filled with glasswool of 50mm, thick of 48KG/mCu.(Owensk-flex/upTwiga)laminated with black FRP the tissue on the outer side,and chicken wire mesh support on the rear side abutting the wall face. Finished in stretched fabric finish, using UPVC grippers (Waltract/ equivalent) fixed to 50mmX12.5mm commercial plywood runners. The fabric to be treated for fire-retardancy
Fullton Board for Backstage on 50mm GI Frame filled with 50mm Glasswool
Supply & Fixing of Loop Pile Carpet (8mm pile height)
Auditorium Hall Pushback Chair Seat & Back Cushioned with Non-Sagging Molded Foam-ISO Certified Chair Width-24"
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 20 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Supplying and installation of Steel Book Shelf as directed by the Engineer-in-charge
Supplying and installation of Single seater & Three Seater Sofa as directed by the Engineer-in-charge
Supplying and installation of Office table as directed by the Engineer-in-charge
Supplying and installation of Revolving chair as directed by the Engineer-in-charge
Supplying and installation of Conference hall table as directed by the Engineer-in-charge
Supplying and installation of Wooden podium as directed by the Engineer-in-charge
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying installation testing and commissioning of CCTV set
Supplying installation testing and commissioning of 18W Quoro Round Panel CD
Supplying installation testing and commissioning of 12W Magic Line
Supplying installation testing and commissioning of 9W wow Buib
Supplying installation testing and commissioning of 1200mm Ceiling fan Gati
Supplying installation testing and commissioning of 400mm Wall Fan Erica
Supplying installation testing and commissioning of 200mm Exhaust fan
Supplying installation testing and commissioning of 5 star Air conditioner a)1.5 ton
Supplying installation testing and commissioning of 5 Star Casette AC- b) 3Ton
Supply, installation and commissioning of 2 way passive Ceiling Speaker with 30 watt at 8 ohm. Maximum Output of Speaker at 100Vand 70V is 30 watt. Low Frequency Transducer (Woofer)of Speaker is 6.5" and High Frequency Transducer is 0.5". Frequency Range of Speaker is 90Hz to 20Khz. Coverage Angle of Speaker is 155 degree Horizontally as well as Vertically at 1 KHz . Sensitivity of Speaker is 88dB with maximum SPL is 102 dB . Speaker Encloser will be Metallic with ABS Plastic Grille. Ø230 x 150 mm
Supply, installation and commissioning of Loudspeaker has a maximum SPL of 135dB and an operating range from 47 Hz to 20 kHz. It features a nominal beamwidth of 90° conical and is vertically asymmetric (+40, -50). The low-frequency transducer is a 12-inch cone with a vented design, while the high-frequency transducer is a 1-inch exit with a 1.4-inch voice coil compression driver, utilizing a linear conical waveguide. It operates in bi-amp mode for both low and high frequencies and incorporates DSP with EAW Focusing and DynO signal processing. The modes available are main/monitor and mic/line. The input type is electronically balanced XLR/TRS, and it also has an electronically balanced XLR loop type. The amplifier is a Class D type, with a maximum output of 1500W peak for both low and high frequencies. 25.2 x 15 x 14.4in (640 x 380 x 365mm)
Supply, installation and commissioning of Multichannel Amplifier. It should have output power of 4 channel x 220W @ 2ohm, 4 Channel x 140W @ 4 ohm and 4 channel x 85W @ 8 ohm or better. It should have output Power (Bridge): 400W @ 4 ohm 310W @ 8 ohm or better. Inputs (Impedance/Sensitivity): 20k ohm / 1 V / 0±1 dBu. It should have frequency Response (stereo mode): 20 Hz - 20 kHz -3dB or better and Frequency Response for subwoofer mode should be : 20 Hz - (50 Hz - 250 Hz) -3dB or better. It should have S/N Ratio: >96 dB. It should have THD: Less than 0.1% at 1kHz. It should have Input Impedance of 20k ohm balanced or 10k ohm unbalanced or better. it should have Load protection: on/off mute, DC fault grounding relay, internal fault fuses feature or more. L 0.28 M X W 0.48 M X H 0.04 M
Supply, installation and commissioning of 10-Channel Mixer with USB & Effects. W 430 mm
Supply, installation and commissioning of Digital signal processor with min. 16AEC enabled Mic/Line inputs, 16 Line outputs or better , Input channel processing should include Pre amplifier, Signal generator, Expander, Compressor, 10 band Parametric EQ or better, Output Channel processing should include 31 band Graphic equalizer, Delay, Crossover, limiter or better, Other features should include Automatic mixing console, Ducker, Feedback elimination, Noise elimination, echo elimination or better, Should have built-in Bi directional USB for Software based VC as well as for playing digital audio, Should have built in Camera tracking Module, 16 Port Freely Configurable GPIO or better with Analog/Digital dynamic range of 114dB or better, Sampling rate of 48Khz or better, Frequency response of 20Hz – 20Khz or better, per channel phantom power module or better. Should be configurable thru software. 45×482×258 mm, Size 19” 1RU
Supply, installation and commissioning of Epson Pro EX9240 3-Chip 3LCD Full HD 1080p Wireless Projector, 4,000 Lumens Color Brightness, 4,000 Lumens White Brightness, Miracast, 2 HDMI Ports, Built-in Speaker, 16,000:1 Contrast Ratio
Supply, installation and commissioning of Tabletop Power & USB Charging Hub
Supply, installation and commissioning of various cables & connectors
Supply of 125 KVA 100 KW 4K KOEL iGreen DG set Engine Model:4K1080TAG2,156 BHP, with 230 Ltrs inbuilt fuel tank capacity, DG set Dimension:3240X1340X1795
Freight charges of DG set from Naltali Factory to site including Unloading
Supply of 150 Sq mm 3.5 core Aluminum armoured UG Cable
Supply of 200 Amps 4 pole changeover switch
Supply of GI Plate Earthing masterials like 1X1 feet plate,GI pipe, GI strip, salt and charcoal etc
Supply ,laying and termination of G.I.strip 25X3
Supply of Aluminum ring lugs 150 sqmm
Supply of Aluminum ring lugs 120 sqmm
Supply of Miscellaneous Items
Service charges towards installation of DG set including Laying & termination of all cable ends after laying the cables through underground.
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
SBD.pdf
Tender Documents • 1.27 MB
BOQ_82487.xls
BOQ • 0.47 MB
LOB.pdf
Additional Documents • 0.42 MB
Corrigendum1.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .