Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.5 LAdmitted-Finance | -25.99% | ₹7.5 L | L1 | Admitted-Finance |
| 2 | L2₹7.7 L+₹15,150.86 (2.01%)Admitted-Finance | -24.50% | ₹7.7 L+₹15,150.86 (2.01%) | L2 | Admitted-Finance |
| 3 | L3₹7.8 L+₹27,352.89 (3.63%)Admitted-Finance | -23.30% | ₹7.8 L+₹27,352.89 (3.63%) | L3 | Admitted-Finance |
| 4 | L4₹8.0 L+₹48,604.76 (6.46%)Admitted-Finance | -21.21% | ₹8.0 L+₹48,604.76 (6.46%) | L4 | Admitted-Finance |
Tender Value
₹10.2 L
EMD Value
₹20,337
Closing Date
24 Mar 2026, 3:00 pmClosed
EE,ELD-9,DDA
EE,ELD-9,DDA
SITC of Electrical Fixtures and Compound Lighting in Community Hallin Block-E, Sector-16, Rohini.
2026_DDA_902771_1
37/EE/ELD-9/DDA/NIT/ 2025-26
Open Tender
Electrical Works
Works
180 days
ROHINI
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹20,337
10 Apr 2026
17 Mar 2026
25 Mar 2026
17 Mar 2026
24 Mar 2026
17 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) 18W-22W LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | - | Each | 734 | - |
| 2 | Supply, Installation, Testing and Commissioning of 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req | - | Each | 2,695 | - |
| 3 | supply of exhaust fan operating on single phase 50 Hz 230 volt AC supply of 380 mm sweep size 2250 cubic mtr./Hr air delivery, minimum 900 RPM with double ball bearing with permanent lubrication and having Motor protection through thermal overload protection device in metal body .(with guarantee/ warranty minimum 2 years) | - | Each | 5,480 | - |
| 4 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
A) Upto 450 mm sweep | - | Each | 450 | - |
| 5 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. | - | Each | 207 | - |
| 6 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application andthe project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | - | Each | 4,550 | - |
| 7 | Supplying of 2x10 sq. mm size of XLPE insulated aluminium conductor unarmored power cable of 1.1 KV grade conforming to IS 7098 Part-1 with up to date amendments. | - | Mtr | 97 | - |
| 8 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle) | - | Mtr | 39 | - |
| 9 | Supply and Fixing of Hot Press Moulded Side Hinged Door type SMC Junction Box with Minimum Inside Dimension of following sizes with suitable size terminal for XLPE Aluminium Power Cable as per site requirement, connection and External Bracket for Fixing on wall i/c making connection, testing etc. complete as required.
a) (H x W x D is 140 x 140 x 95 mm) | - | Each | 1,044 | - |
| 9.1 | b) (H x W x D is 570 x 280 x 220 mm) | - | Each | 4,563 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.02 MB
NIT37.pdf
Tender Documents • 1.72 MB
BOQ_948877.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .