| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | ₹5.3 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹6.4 L+₹1.1 L (20.5%)Rejected-Finance | ₹6.4 L+₹1.1 L (20.5%) | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | ANAND REFRIGERATION L1 | JM Engineering L2 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive Maintenance of CPSS Central A/C plant 2x24 TR capacity, control panel, complete incl material and labour, spares lubricants installed at CPSS bldg, checking of leakage on refrigerant gas, checking of refrigent pressure and toping up if reqired, replacement of glands, 'O' ring gaskets, nuts, bolts, washers and routine checks like oil level, V belts, electrical control wires, cleaning of filters, greasing to the motor, replacement of gland packing to pump, indicating lamp to panel etc, but excluding repairs to the plants all as specified and directed | 12 | Month | 9,800 ₹1,17,600 Lowest | 14,500 ₹1,74,000 |
| 2.00 | Supply and install in repair MCCB adjustable type 200 amps, 415 volts , 3 pole, 50 HZ, 36 KA including spreader links on both sides complete all as specified and directed | 1 | Each | 16,342 ₹16,342 | 15,200 ₹15,200 Lowest |
| 3.00 | All as per item No.2 above but fixed type, 3 pole, 25 to 100 A and 16 KA | 2 | Each | 5,000 ₹10,000 | 4,500 ₹9,000 Lowest |
| 4.00 | Supply & Fix in replacement MCB 40 Amps, C curve, 415 volts , TPN, 50 HZ, 10 KA complete all as specified and directed | 2 | Each | 2,672 ₹5,344 | 2,200 ₹4,400 Lowest |
| 5.00 | Supply and Fix in replacement of three phase fully automatic Star Delta starter suitable for 7.5 HP Pump/motor 3 Phase, 415 V, 50 Hz, relay range 9-15 Amp, having MN relay is with single phase prevention feature complete all as specified and directed | 1 | Each | 11,000 ₹11,000 Lowest | 14,500 ₹14,500 |
| 6.00 | M & L for taking down AHU blower motor of capacity 7.5 HP including disconnecting electric connections, dismantling of motor, taking out the burnt widings, cleaning the slots and rewinding the same with copper winding wire of exixting guage and quantity (as per original manufacturer design) including replacement of all damaged parts i.e. bearing, bush, thrust plate, connector plate, insulating materials such as insulating sheets, sealing compounds etc and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc and reinstallation of the motor in original location, checking the alingnment, making proper electric connection, testing for smooth operation, completereqired accessories all as directed | 2 | Each Job | 8,250 ₹16,500 Lowest | 9,500 ₹19,000 |
| 7.00 | All as per item no.6 above but cooling tower fan motor upto 5 HP capacity complete all as specified and directed. | 1 | Each | 6,500 ₹6,500 Lowest | 7,500 ₹7,500 |
| 8.00 | M & L for leakage testing by filling with Nitrogen & Vacumailising for Chiller unit of 24 TR | 4 | Each Job | 8,500 ₹34,000 Lowest | 9,000 ₹36,000 |
| 9.00 | Cleaning/ Servicing of each Chiller plant (having 02 nos of condesing & evaporation units) to descaling complete by using chemical to prevent the condensing coil suitable for central AC plant making the unit completely functional by OEM all as specified and directed by engineer in charge | 2 | Each jab | 11,000 ₹22,000 Lowest | 12,000 ₹24,000 |
| 10.00 | Repair/ maintenance of Air handling unit including sevicing filter section,blowing agent,scratch free platisol coating,fan section,discharge,limit switches,fittings ,valves,pressure gauges,purge cocks,flanges,strainers,hot water genearor,class b insulation,humidisats,thernostats,mixing valves,accoustic insulation,fresh air damper and mosquito proof netting and any other connected items by OEM and making the unit completely functional complete all as specified and directed by engineer in charge. | 2 | Each job | 35,000 ₹70,000 Lowest | 55,000 ₹1,10,000 |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
20 Dec 2025, 6:00 pmClosed
Shri Shubham Yadav, AEE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
COMPREHENSIVE MAINTENANCE TO CENTRAL AC PLANT SYSTEM OF CPSS AT 2AFSB MYSORE UNDER AGE (I) AF CHIMNEY HILLS
2025_MES_742160_1
8866/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
2AFSB Mysore
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF Chimney Hills, Bangalore
₹12,000
Yes
9 Feb 2026
29 Nov 2025
27 Dec 2025
29 Nov 2025
20 Dec 2025
13 Dec 2025
29 Nov 2025 - 6 Dec 2025
Amount
Comprehensive Maintenance of CPSS Central A/C plant 2x24 TR capacity, control panel, complete incl material and labour, spares lubricants installed at CPSS bldg, checking of leakage on refrigerant gas, checking of refrigent pressure and toping up if reqired, replacement of glands, 'O' ring gaskets, nuts, bolts, washers and routine checks like oil level, V belts, electrical control wires, cleaning of filters, greasing to the motor, replacement of gland packing to pump, indicating lamp to panel etc, but excluding repairs to the plants all as specified and directed
Supply and install in repair MCCB adjustable type 200 amps, 415 volts , 3 pole, 50 HZ, 36 KA including spreader links on both sides complete all as specified and directed
All as per item No.2 above but fixed type, 3 pole, 25 to 100 A and 16 KA
Supply & Fix in replacement MCB 40 Amps, C curve, 415 volts , TPN, 50 HZ, 10 KA complete all as specified and directed
Supply and Fix in replacement of three phase fully automatic Star Delta starter suitable for 7.5 HP Pump/motor 3 Phase, 415 V, 50 Hz, relay range 9-15 Amp, having MN relay is with single phase prevention feature complete all as specified and directed
M & L for taking down AHU blower motor of capacity 7.5 HP including disconnecting electric connections, dismantling of motor, taking out the burnt widings, cleaning the slots and rewinding the same with copper winding wire of exixting guage and quantity (as per original manufacturer design) including replacement of all damaged parts i.e. bearing, bush, thrust plate, connector plate, insulating materials such as insulating sheets, sealing compounds etc and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc and reinstallation of the motor in original location, checking the alingnment, making proper electric connection, testing for smooth operation, completereqired accessories all as directed
All as per item no.6 above but cooling tower fan motor upto 5 HP capacity complete all as specified and directed.
M & L for leakage testing by filling with Nitrogen & Vacumailising for Chiller unit of 24 TR
Cleaning/ Servicing of each Chiller plant (having 02 nos of condesing & evaporation units) to descaling complete by using chemical to prevent the condensing coil suitable for central AC plant making the unit completely functional by OEM all as specified and directed by engineer in charge
Repair/ maintenance of Air handling unit including sevicing filter section,blowing agent,scratch free platisol coating,fan section,discharge,limit switches,fittings ,valves,pressure gauges,purge cocks,flanges,strainers,hot water genearor,class b insulation,humidisats,thernostats,mixing valves,accoustic insulation,fresh air damper and mosquito proof netting and any other connected items by OEM and making the unit completely functional complete all as specified and directed by engineer in charge.
Servising/repaire of cooling tower consist of Supply and fix in repairs providing new mats ,mess( Honey comp Fins made of polythene/PVC), for cooling tower of 50 TR cap and servicing of induced draft fan and connected items including chemical cleaning of cooling tower servising comlete suitable for central AC plant making the unit completely functional by OEM all as specified and directed by engineer in charge
Supply only filling/topup R-22 refrigerant gas
Supply only copper harden pipe 5/8x1.1/8
Supply only drier suitable to ac plant complete all as specified and directed.
Repairs to electric driven pump set of 7.5 HP including removing from the foundation dismantling ,taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for complete all as specified and directed by Engineer in Charge (Note: Rewinding and supply of Spares will be paid under relevant items here in after)
Rewinding of motor startor coil complete using super enamelled copper wire of same gauge for coil , cleaning the slots and quantity (as per original manufacturer design) including , insulating materials such as insulating sheets, sealing compounds etc and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc and reinstallation of the motor in original location,
Supply and fix Ball bearing (drive and non dirve end)
Supply only Cooling fan blade PVC
Supply only Terminal box with terminal connector
Supply only Gunmetal bush
Supply only Gland cup with bolts and nuts
M&L for replacing old detoriated Armo flex foam insulstion of copper pipe of chiller unit of 24 TR complete with new foam insulation material
M & L for detecting and rectifying leakage of Chiller water AC water pump
Supply only Pressure guage
Supply only room temperature indication guage
Supply only single phase preventor suitable for three phase star delta starter Make : Minilec
M & L for detecting and rectifying leakage of Condensor water pump
JM Engineering (BID ID -3498668)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_831059.xls
BOQ • 0.29 MB
8866Tender.pdf
Tender Documents • 0.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .