| 1 | L1₹20.0 LAccepted-AOC 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹20.0 L Quoted ₹20.4 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹22.4 L+₹2.0 L (9.87%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | ₹22.4 L+₹2.0 L (9.87%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not approved |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
18 Feb 2025, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
Repair Maint of Central AC Plant Compressor Condensor and Connected items at MH and SSA under AGE EM of GE Jaipur
2025_MES_693981_1
CWE/JPR/82439/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE JAIPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE JAIPUR
₹59,000
Yes
13 Jun 2025
20 Jan 2025
20 Feb 2025
20 Jan 2025
18 Feb 2025
4 Feb 2025
20 Jan 2025 - 4 Feb 2025
Amount
Material and Labour for overhauling of complete of 80 TR capacity chiller unit of Voltas make complete with replacement of worn out /unserviceable parts including piston, piston rings, connecting rod, connecting rod bearings, gudgeon pin, head spring, compressor bearing, crank shaft, oil seal, oil ring, oil plate, compressor cylinder, load/unload assembly, oil pressure valve, suction reed, discharge reed, oil pump, gasket, oil filter, fan belt, temperature meter, pressure meter, LP switch, HP switch, oil failure switch, oil pressure switch, temp sensor, gas sensor, drayer, solenoid coil, chiller main controller circuit, coupling etc. and reassembling the same after complete repair and replacement of parts with accessories as nut, bolts, washers etc. , installation on existing foundation, coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge Note :- Servicing & Repairing work of chiller unit to be done by the authorised representative of OEM. All spares parts mentioned in above description as required for repair /servicing shall be deemed to be quoted in this item only.
Cleaning and descaling of condensor of 80 TR Central AC plant by suitable chemical circulation and brushing of condenser tubes as required. Note:- Descaling of condensor coils of each plant will be done in every three months cycle.
Servicing of AHU's cleaning cooling coils by non acidic chemical, cleaning of filters by suitable tools as required.
M&L for renewal of unserviceable mechanical oil seal of compressor at coupling end including testing and commissioning complete. Note :-Gas/Oil required to be changed after renewal of mechanical oil seal will be measured and paid separately in respective items of BOQ.
Dismantling, opening, rewinding and refixing 3 phase, 440V, 50 Hz induction motors with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechnical works for shaft/bearing housing , renewal of DE and NDE beaings, transportation from installation to workshop & back, connecting testing and commissioning at site for satisfactorily operation as required for (i) 3 to 7.5 HP.
All as per item No 05 above but 10 HP Motor.
All as per item No 05 above but 12.5 to 20 HP Motor.
All as per item No 05 above but 100 HP Motor.
Dismantling and taking out defective monoblock pump of capacity 52 LPS. make- Kirloskar from foundation and shifting it to workshop for repair/replacement of impellers, beanings, seals etc. Refitting at foundation after repair testing and commissioning complete to the entire satisfaction as required.
Dismantling and taking out defective centrifugal pump of capacity 123 cum /hr , Make - kirloskar from foundation and shifting it to workshop for repair/replacement of impellers, bearings, seals etc, Refitting at foundation after repair testing and commissioning complete to the entire satification as required.
M&L for checking/repair/calibration of microm adjuster of compressor control panel, model-VLRP single,type dluxe (Make- Softhard intelli Sys)
S&F in repair microprocessor based controller of compressor control panel of 80 TR central AC plant with internal wiring and connections. Make:- Voltas/ Softhard Intelli/ Seimens.
M&L for renewal of PVC water tank heavy duty of capacity 5000 ltrs with CI strip ground around it to avoid bulging/deformation of tank as per existing including plumbing work as reqired. (Make- Sintex/polycon as approved)
M&L for refrigerant oil for compressor. Make- HPCL- N 68/ Indian Oil- Servo-Friz/ BPCL-Freezol 68 as approved.
S&F in repair contactor of LT panel of AC plant, MNX 18, AC supply, 230V, 50HZ , 4 Pole. Make- L&T /Siemens /ABB as approved.
S&F in repair contactor of LT panel of AC plant, MNX 22, AC supply, 230V, 50HZ , 3 Pole. Make- L&T /Siemens /ABB as approved.
S&F in repair contactor of LT panel of AC plant, MNX 25, AC supply, 230V, 50HZ , 3 Pole. Make- L&T /Siemens /ABB as approved.
S&F in repair contactor of LT panel of AC plant, MNX 32, AC supply, 230V, 50HZ , 3 Pole. Make- L&T /Siemens /ABB as approved.
S&F in repair front mounting add-on aux, contact block for contactor of LT panel of AC Plant, MNX - A1 or MNX-A2, AC, 415V, 50 Hz. Make:- L&T/Siemens/ABB as approved.
S&F in repair single phasing preventor of the LT panel of AC plant, 3 phase AC, 415 volt, 50 Hz. Make:- L&T/Minilec as approved.
S&F in repair MCB TP, 63 amps, AC, 10 KA, 'C' series of the LT panel of AC plant. Make- Legrand/ Schneider/Hagar as approved.
S&F in repair MCB TP, 40 amps, AC, 10 KA, 'C' series of the LT panel of AC plant. Make- Legrand/ Schneider/Hagar as approved.
S&F in repair contactor of compressor control panel AC,415 V, 50 Hz, 3 Phase, Model 3TF47. Make- L&T/Siemens/ ABB as approved.
S&F in repair contactor of compressor control panel, AC, 415 V, 50HZ, 3 phase, Model 3TF49. Make- L&T/ Siemens/ ABB as approved.
S&F in repair thermal overload relay of range 9-15A, 14-23A, type direct mounting on MNX, for control panel. Make- L&T /Siemens/BB as approved.
S&F in repair contactor of compressor control panel, MNX 140, 3 Phase AC, 415V, 50Hz. Make- L&T/Siemens / ABB as approved.
S&F in repair magnetic solenoid coil, 220 volts, AC supply as per existing.
S&F in repair transducer PT3-30 Bar of compressor with horness as per existing.
S&F in repair digital timer of compressor control panle, time range 3-60 secs, 24/200-240V, 50HZ as per existing.
M&L for filling of refrigerant gas R-407 for central AC plant in topping up during servicing / maintenance as required.
S&F in repair rubber coupling of motor and compressor as required
S&F in repair V belts for AHU motors of existing size and type as required.
S&F in repair heating elecments of 2.0 KW capacity of lengths from 1.5 to 2.5 ft as per site requirement.
S&F in repair heating elecments of 3.0 KW capacity of lengths from 1.5 to 2.5 ft as per site requirement.
S&F in repair phase indicating lamps LED type with the colour code as per existing.
S&F in repair water pressure indicating gauge fitted in water circulation circuit minimum range 0 to 7 kg/sqcm. Make- IEBIG/H-Guru/Gluck as approved.
S&F in repair water temperature gauge fitted in water circulation circuit minimum range 10 to 50 degree centigrade. Make -IEBIG/ H-Guru/ Gluck as approved.
S&F in repair high flow HEPA filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13, capacity 2000 CFM of size 610mm x 610mm x 305mm. Make : Thermadyne/ Puromatic /Primide /Dyna as approved.
S&F in repair high flow HEPA filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13, capacity 1000 CFM of size 610mm x 305mm x 305mm. Make : Thermadyne/ Puromatic /Primide /Dyna as approved.
S&F in repair high flow HEPA filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13 and of 1000 CFM of size 305mm x 610mmx305mm. Make : Thermadyne/ Puromatic /Primide /Dyna as approved.
S&F in repair high flow HEPA filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and EU 13 and of 500 CFM of size 305mm x 305mmx305mm. Make : Thermadyne/ Puromatic /Primide /Dyna as approved.
S&F in repair FINE fiter, flange type efficiency 99.00% down to 5.0 micron and EU 5 of size 610mmx610mm x305mm. Make- Thermadyne /Puromatic/ Primide/ Dyna as approved.
S&F in repair FINE filter, flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 305mm x 610mmx305mm. Make Thermadyne/puromatic/ Primide/Dyana as approved.
S&F in repair FINE filter flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 610mmx 305mmx 305mm. Make- Thermadyne/Puromatic/ Primide/Dyna as approved.
S&F in repair FINE filter flange type, efficiency 99.00% down to 5.0 micron and EU 5 of size 305mmX 305mm X305mm. Make- Thermadyne/Puromatic/ Primide/Dyna as approved.
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx610mmx50mm. Make- Thermadyne/Puromatic/ Primide/Dyna as approved.
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx305mmx50mm. Make- Thermadyne/Puromatic/ Primide/Dyna as approved.
S&F in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 305mmx305mmx50mm. Make- Thermadyne/Puromatic/ Primide/Dyna as approved.
S&F in repair HF type HRC cylindrical fuses of rating from 2A to 32A. Make- L&T/BCH/Havells as approved.
S&F in repair HF type HRC cylindrical fuses of rating from 63A. Make- L&T/BCH/Havells as approved.
S&F in repair HN type DIN fuse links of rating 200A. Make L&T/BCH/Havells as approved.
S&F in repair HN type DIN fuse links of rating 630A. Make L&T /BCH/Havells as approved.
Repair and Maint of 200TR capacity cooling tower. Maintenance work include cleaning of cooling tower by removing scale and sludge formation, oiling & greesing of moving parts, replacement of PVC fills, replacement of other defective parts as required and directed by Engr-in-Charge. (Note:- Parts replaced will be measured and paid separately under respective item of BOQ)
S&F in repairs sprinkler head of size 6th with 4 blades and all accessories complete.
S&F in repairs PVC drift eliminator.
S&F in repairs PVC sprinkler pipe with end cap.
S&F in repairs tension devices viz. tie rod, turn buckle and clamp.
S&F in repairs pipe louvre.
S&F in repairs PVC fills of cooling tower of size 600mm x 300mm x 150mm
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32x6 mm by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete.
S&F in repair complete electrical internal wiring of 80 TR Central AC Plant compressor contol panel all as specified and directed by Engr-in-Charge.
S&F in repair MCCB 630A, TP,415V, 50 Hz, 50KA adjustable type, thermal release of make L&T or equivalent etc. complete all as specified & as directed.
S&F in repair MCCB 400A, TP,415V, 50 Hz, 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed.
S&F in repair MCCB 250A, TP, 415V, 50 Hz 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed.
S&F in repair MCCB 160A, TP,415V, 50 Hz 36KA adjustable type of make L&T or equivalent etc. complete all as specified & as directed.
Supply, laying, connecting and testing of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 185 Sqmm, 3.5 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps/lugs/fixing arrangements complete as directed by Engr-in-Charge.
Supply, laying, connecting and testing of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 35 Sqmm, 4 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps/lugs/fixing arrangements complete as directed by Engr-in-Charge.
Less Schedule of Credit
Industrial Traders (BID ID -3241529)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .