Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee | Not Admitted-Fee Fee not received |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
19 Oct 2020, 12:00 pmClosed
SUPREINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, MEERUT
RELEASING OF NEW CONNECTION AND CONSTRUCTION OF HT/LT LINE APPLIED IN JHATPAT/NIVESH MITRA PORTAL CONSUMER (RUNNING CONTRACT UNDER DEPOSIT SCHEME) IN THE AREA OF EDSD-III, MEERUT UNDER EDD-I, MEERUT
2020_PVVNL_514057_1
56/EDC-MT/2020-21
Open Tender
Electrical Works
Lump-sum
30 days
WORKS
RELEASING OF NEW CONNECTION AND CONSTRUCTION OF HT/LT LINE APPLIED IN JHATPAT/NIVESH MITRA PORTAL CONSUMER (RUNNING CONTRACT UNDER DEPOSIT SCHEME) IN THE AREA OF EDSD-III, MEERUT UNDER EDD-I, MEERUT
3 documents required · 3 mandatory
₹590
SUPREINTENDING ENGINEER
₹2,000
Yes
9 Nov 2020
23 Sept 2020
19 Oct 2020
23 Sept 2020
19 Oct 2020
23 Sept 2020
Amount
Cartage of following material from store center Meerut to JE Store including loading & unloading at both ends maximum distance up to 30 Km. :-
PCC Pole 8.5 Mtr Long/STP Pole 11 Mtr. Long.
Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel, TPMO, Fuse set etc.
25 KVA to 63 KVA T/F and 11 KV CT/PT Unit and Metering Cubical
Cartage of following material from JE, Store to site of work including loading & unloading at both ends maximum distance up to 30 Km. :-
PCC Pole 8.5 Mtr Long/STP Pole 11 Mtr. Long.
Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel, TPMO, Fuse set etc.
25 KVA to 63 KVA T/F and 11 KV CT/PT Unit and Metering Cubical
Erection of PCC pole 8.5 Mtr long/STP Pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of all 11 KV HT/LT line accessories.
Erection of Double pole on STP pole 11 mtr after digging a pit of size1.6 mtr deep in all type of Soil for each pole including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of MS angle and MS channel, fixing all 11 KV accessories TPMO, Fuse set 11 KV pin insulators on D/P Pole.
Mounting of 25 to 63 KVA T/F with proper jumpering of HT side and fixing of cable on LT side of T/F.
Making a section pole to exist pole after fabrication & fixing of T channel fixing of all 11 KV accessories.
Erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Laying lifting stringing & proper sagging of LT ABC Cable 3x120 sq.mm
Earthing of each 11 KV line pole & T/F properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GL wire.
Providing and fixing of Holding Clamp for STP pole
Providing and fixing of MS Nut & Bolts off size
Providing and fixing of Stay clamp for STP pole
Laying, Stringing and Sagging of 11 KV XLPE of size 3x120 sq.mm
Fixing the cable jointing kit with the end of XLPE cable including mounting the same on pole with proper binding.
Grouting of Metering Cubical
Water level earthing
Cutting & chopping tree branches near side of line for making the clearance between line and tree.
M/s Kumar Traders
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .