Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹16.3 L+₹49,835 (3.15%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹22.3 L+₹6.5 L (41.0%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
2 May 2022, 6:00 pmClosed
Maj Vijay Kumar Sharma
Garrison Engineer West 62 Station Road Agra Cantt
REPAIR AND MAINTENANCE OF SPLIT WINDOW TYPE AC WATER COOLER FRIDGE DEEP FREEZER ETC WITH MISC E M WORKS UNDER AGE EM W OF GE W AGRA
2022_MES_516276_1
8012/873/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹60,000
6 Jul 2022
2 Apr 2022
4 May 2022
2 Apr 2022
2 May 2022
16 Apr 2022
Amount
Routine / Periodical / General servicing of window type AC of 1.5/2.0 TR capacity (On Site) including cleaning / washing ( by water or by blower), oiling, greasing etc as per standard engineering practice / Manufacturer's instructions under AOR of AGE E/M (W) Agra by skilled mechanic complete all as specified and directed by Engr-in-Charge. Notes:- (i) Cost of minor items such as nuts, bolts, washers, screws clips saddles oil, grease rubber gaskets etc as required at site deemed to be included in quoted unit rates of items/jobs. (ii) Location and place of complaints shall be any where under AOR of AGE E/M (W) Agra as per requirement of maintenance work (iii) Contractor shall be responsible to provide conveyance and required tools, safety measurers etc for attend the complaints. (iv) Contractor is responsible for make appliances serviceable with in two days from the date of complaint lodged by user. Job card for the same shall be collected on daily basis from office of Engr-in-Charge. If the compliant is not resolved withhin specified period, Rs 500.00 shall be recovered from the contractors dues as penalty.
All as per item No. 1 here in before but for split AC of capacity 1.5/2.0 TR capacity of any make.
All as per item No. 1 here in before but for refrigerator of any capacity of any make.
All as per item No. 1 here in before but for deep freezer/water cooler/water dispenser of any capacity of any make.
Supply and fixed in repair & testing of Reciprocating/Rotary type hermetically sealed compressor unit for 40/80 ltr capacity water cooler with compressor oil including gas charging and testing complete all as specified and directed.
Supply and fixed in repair & testing of Reciprocating / Rotary type hermetically sealed compressor unit for 60/120 ltr capacity water cooler with compressor oil including gas charging and testing complete for water cooler all as specified and directed.
Supply and fixed in repair & testing of Reciprocating/Rotary type hermetically sealed compressor unit for 150 ltr capacity water cooler with compressor oil including gas charging and testing complete for water cooler all as specified and directed.
Supply and fixed in repair & testing of Reciprocating/Rotary type hermetically sealed compressor unit for 280/310 ltr capacity Deep Freezer with compressor oil including gas charging and testing complete for Deep Freezer all as specified and directed. Note for item No. 5 to 8: Refrigerant gas shall be measured and paid separately under respective item here-in-after.
Supply and fixed in repair starting capacitor of 40-60 MFD capacity for water cooler any capacity complete all as specified and directed.
Supply and fixed in repair starting capacitor of 80-100 MFD capacity for water cooler complete all as specified and directed.
S & F repair starting capacitor of 100-120 MFD capacity for AC complete all as specified and directed. Make
S & F repair running capacitor of 10 to 45 MFD capacity for AC complete all as specified and directed.
S & F repair running capacitor of 45 +2 MFD capacity for AC complete all as specified and directed.
S & F repair running capacitor of 45+6 MFD capacity for AC complete all as specified and directed.
S & F in repair running capacitor of 50+2 MFD capacity for AC complete all as specified and directed.
S & F in repair running capacitor of 50+6 MFD capacity complete all as specified and directed.
S & F in repair running capacitor of 55+2 MFD capacity for AC complete all as specified and directed.
S & F in repair running capacitor of 55+6 MFD capacity for AC complete all as specified and directed.
S & F in repair running capacitor of 60+2 MFD capacity for AC complete all as specified and directed.
S & F in repair running capacitor of 60+6 MFD capacity for AC complete all as specified and directed.
S & F in repair electric blower motor of outdoor unit split AC of size 1/10 HP and fixing the same in its existing position after taking out existing motor and testing complete all as specified and directed.
S & F in repair electric blower motor of outdoor unit split AC of size 1/8 HP and fixing the same in its existing position after taking out existing motor and testing complete all as specified and directed.
S & F in repair electric blower motor of window AC of size 1/10 HP and fixing the same in its existing position after taking out existing motor and testing complete all as specified and directed.
S& F in repair electric blower motor of window AC of size 1/8 HP and fixing the same in its existing position after taking out existing motor and testing complete all as specified and directed.
S & F in repair flexible copper conductor cable PVC insulated & PVC sheathed of size 4.0 Sqmm or (40/0.0076), 1100 Volt grade 3 core complete all as specified and directed.
S & F in repair flexible copper conductor cable PVC insulated & PVC sheathed of size 2.5 Sqmm or(23/0.0076), 1100 Volt grade 4 core complete all as specified and directed.
S & F in repair perforated condenser unit made out of copper tube and copper 'U' joints suitable for any type water cooler complete all as specified and directed.
S & F in repair over load/starting relay kit suitable for 165-310 ltrs capacity refrigerator of approved make and testing complete all as specified and directed.
S & F in repair thermostat switch suitable for 165 to 310 Ltr capacity refrigerator of approved make complete all as specified and directed .
S & F in repair / replacement & testing of hermetically sealed unit compressor for Refrigerator of 280 / 310 ltrs capacity with compressor oil including gas charging and testing complete all as specified and directed .
S & F in repair & testing of company repaired Reciprocating/ Rotary Type hermetically sealed compressor unit for Refrigerator of 165 ltrs capacity with compressor oil including gas charging and testing complete all as specified and directed Note for item No 30 & 31 : Refrigerant gas shall be measured and paid separately under respective item here-in-after.
S & F in repair timer for frost free refrigerator (Self defrosting type) of capacity 280 to 310 ltrs capacity, suitable for LG / Samsung make refrigerators all as directed.
S & F in repair sensor switch for frost free refrigerator (Self defrosting type) of capacity 280 to 310 ltrs capacity, suitable for LG / Samsung make refrigerators all as directed.
M & L for repairing the refrigerator or water cooler body by cutting the worn out/ rusted/damaged portion of body with the help of gas welding and jointing the pieces of 18 gauge MS sheet with gas welding as required and making the surface smooth to match the existing surface by grinding and then applying two coats of Ducco paint with spray machine over one coat of red oxide primer complete all as specified and directed
S & F in repair magnetic type door gasket suitable for 165 to 310 Ltrs capacity of approve quality/ make of refrigerator complete all as specified and directed
S & F in repair vegetable tray made out of high quality PVC / plastic, clear transparent type suitable for 165 to 310 Ltrs capacity refrigerator of approve quality / make complete all as specified and directed
S & F in repair thermostat switch adjustable type with Knob suitable for window type AC of 1.5 TR / 2 TR Capacity complete all as specified and directed.
S & F in repair starting relay suitable for any type AC of 1.5 TR/2 TR capacity complete all as specified and directed.
S & F in repair & testing of company repaired Reciprocating/Rotary type hermetically sealed compressor unit with and incl first fill of compressor oil suitable for 1.5 TR capacity window type AC complete all as specified and directed.
All as per item No 39 above but suitable for 2 TR capacity window type AC complete all as specified and directed
S & F in repair & testing of company repaired hermetically sealed , Reciprocating/ rotary type compressor unit with and incl first fill of compressor oil suitable for 1.5 TR capacity Split AC complete all as specified and directed.
S & F in repair & testing of company repaired hermetically sealed , Reciprocating/ rotary type compressor unit with and incl first fill of compressor oil suitable for 2 TR capacity Split AC complete all as specified and directed. Note for Item No 39 to 42 Refrigerant gas will be measured and paid saperatly under respective item here-in-after.
Dismantling of burnt blower motor 1/6 HP capacity of split type AC and rewinding the same with super enameled copper winding wire of same gauge and turn with and including top quality insulation material such as varnish, cotton tape & sleeves etc and replacement of gun metal bush / bearing and re-fixing back in its original position after testing complete all as directed.
S & F in repair aluminium / hard PVC fan blade of blower motor suitable for window type AC of 1.5 TR / 2 TR capacity complete all as specified and directed.
S & F in repair PCB suitable for 1.5/2.0 TR capacity any type AC complete all as specified and directed .
S & F in repair PCB suitable for 4.0/5.0 KVA capacity voltage stabilizer complete all as specified and directed .
All as per item No 46 above but for 0.5/1 KVA capacity voltage stabilizer.
Taking out burnt components of auxiliary PCB of voltage stabilizer of 4.0/5.0 KVA capacity and re-fixing back in original position after making it serviceable/repair complete all as specified and directed.
All as per item No 48 above but for 0.5/1 KVA capacity voltage stabilizer.
S & F in repair auxiliary transformer of voltage stabilizer of 4.0/5.0 KVA capacity complete all as specified and directed.
All as per item No 50 above but for 0.5/1 KVA capacity voltage stabilizer.
S & F in repair main transformer of voltage stabilizer 5.0 KVA capacity complete all as specified and directed.
All as per item No 52 above but for 4.0 KVA capacity voltage stabilizer.
All as per item No 52 above but for 1.0 KVA capacity voltage stabilizer.
All as per item No 52 above but for 0.5 KVA capacity voltage stabilizer.
S & F in repair auto cut off relay /time delay relay suitable for the 4.0/5.0 KVA capacity voltage stabilizer complete all as specified and directed.
S & F in repair MCB, SP, 25 Amp complete all as specified and directed.
S & F in repair plazma filters of window type AC/Split AC of capacity 1.5 TR/ 2 TR of any make, including dismantling and cleaning the AC unit with air blower complete all as specified and directed.
M&L for cutting and removing the rusted/ worn out portions of the water cooler bottom / base of any make/ size and making new base with MS sheet and angle iron of the existing gauge and size, including provision of standing legs made either with sheets or angle iron and also carried out two coats of black synthetic enameled paint over a coat of red oxide complete all as specified and directed .
M&L for taking down carefully window type ACs of any capacity, any make and refixing the same in other location in the same complex including making necessary opening in existing wall and packing to opening surrounding the unit including packing material, necessary electric connections and making functional the AC at new location complete all as directed.
M&L for taking down carefully the indoor and out door unit of split Air conditioner of any capacity from existing location and fixing the complete unit in new location of same complex, making all electric and copper tubing connections complete all as specified and directed.
S & F in repair copper tubes of 5/8’’ dia for 2.0 TR capacity Split Air conditioner including flare nuts as required at site complete all as specified and as directed.
S & F in repair copper tubes of 3/8’’ dia for 1.5 TR capacity Split Air conditioner including flare nuts as required at site complete all as specified and as directed.
S & F in repair copper tubes of 1/2’’ dia for any type Split Air conditioner including flare nuts as required at site complete all as specified and as directed.
S & F in repair copper tubes of 1/4’’ dia for any type Split Air conditioner including flare nuts as required at site complete all as specified and as directed.
S & F in repair flexible PUF type / foam type insulation suitable for insulating the suction and discharge line/site of split Air conditioner complete all as directed.
S & F in repair remote control of any type of ACs ( Split/ Window) including battery complete all as directed.
S & F in repair swing motor as per existing type and model for any type AC complete all as specified and directed
S & F in repair blower motor as per existing type and model for indoor unit of any capacity split AC complete all as specified and directed
S & F in repair solonoied reverse switch for any type of split AC complete all as specified and directed
M & L for detection of leakage of 300 ltrs capacity deep freezer inside the cabinet/puf / insulated body including changing new insulating material of complete deep freezer, make it functional complete all as specified and as directed.
S & F in repair condenser unit made out of copper tube and copper 'U' joints for outdoor unit of split AC 2.0 TR capacity as per existing make & model complete all as specified and directed.
S & F in repair condenser unit made out of copper tube and copper 'U' joints forf outdoor unit of split AC of 1.5 TR capacity as per existing make & model complete all as specified and directed.
Supply and charging of refrigerant gas (M-22) in AC (Window/split) refrignet, water coolers etc complete all as specified and directed.
All as per item No 74 above but refrigerant Gas M-134
All as per item No 74 above but refrigerant Gas R-32
All as per item No 74 above but refrigerant Gas R-410
S& F repair in indoor unit of split type, 1.5 TR capacity AC including remote control and testing complete all as directed.
Supply & fixing in indoor unit of split type 2.0 TR capacity AC including remote control and testing complete all as directed.
M&L for Sub main single phase two wire with PVC insulated and unsheathed FRLS , multistranded copper conductor cable of size 4.0 sqmm drawn through & including PVC rigid conduit medium quality 20mm bore from main board to sub main board incl 4.0 Sqmm PVC insulated unsheathed FRLS stranded copper conductor cable as earth wire including cutting chases to brick wall for inserting conduit and making good in CM 1:4 and finishing the surface to match with the existing specifications complete all as specified and directed. (Note: (i) Measuring unit comprises two sub main wire, one earth wire, conduit and cutting chases all as described above. (ii) Proper colour code for different wires phase, neutral & earth shall be used. (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor .
Supply & fixing repair in sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket with one No.MCB, SP, 230 volts, 20 Amps complete all as specified and directed.
M/S SHARADA ASOCIATE
Shiva Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .