Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹34.1 L+₹71,407.50 (2.14%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹40.0 L+₹6.5 L (19.5%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹40.0 L+₹6.5 L (19.6%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
13 Jun 2020, 6:00 pmClosed
MAJ ALIF MANSOOR
GARRISON ENGINEER MES NASIRABAD - 305 601 (Raj)
SPECIAL REPAIR SEWAGE LINE OF OFFRS MD ACCN IN NORTH AREA SPECIAL REPAIR SEWAGE LINE OF JCO OR MD ACCN BLDG No 88 TO 90 DOGRA LINE SPECIAL REPAIR DRAINAGE LINE BEHIND MECHANICAL LAUNDRY OF MH NASIRABAD TO INFRONT OF PATIENTS COOK HOUSE
2020_MES_339306_1
8924/E8
Open Tender
Civil Works
Item Rate
183 days
NASIRABAD
AS PER NIT
6 documents required · 6 mandatory
₹500
GE NASIRABAD
₹86,000
Yes
25 Jun 2020
17 Apr 2020
15 Jun 2020
17 Apr 2020
13 Jun 2020
26 May 2020
17 Apr 2020 - 30 Apr 2020
Amount
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified & directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified & directed.
Removal of excavated material (soil) n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified & directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations of drain complete all as specified and directed.
M&L mild steel TMT bars in reinforcement 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends , and binding with and including binding mild steel wire(annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in surface channel and drain etc. complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, metered /stopped ends etc complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landing, cover slabs, shelves and manhole cover, window or door cills, lintels, bressumers, steps, quion blocks, (for use with masonary) string courses, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete all as specified and directed.
Cutting into existing manholes for removing existing branch drain, making good to pipe and rendering cutting out branch channel, and making good benchings complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for brickwork with sub class B (old size) bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
All as per sl item no 12.00 here in before but except brick. NOTE: Old serviceable stones/brick retrieved vide Sl Item no 11.00 shall be reused.
M&L for brick work with fly ash bricks , straight or curved on plan to any radius built in half brick thick wall, built in CM 1:4 complete all as specified and directed.
M&L for stone walling of Random rubble, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
All as per sl item No 15.00 here in before but except stone. NOTE: Old 11.00 shall be reused.
Extra over stone walling of random rubble, uncoursed for hammer dressing to face stones and dressing of face beds and joints, hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 20mm complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm crushed stone aggregate) as in cills, steps, seismic and other similar bands, plinth courses, parapets, bed blocks, copings, roof kerb, benching/haunching, bed plates, roof padding and the like including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and directed .
M & L PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternate bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete is reinforced (reinforcement cut as required to facilitate demolition) in any position & of any description not otherwise specifically provided for complete all as specified and directed. complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed by Engineer-in-charge.
M & L for non-skid ceramic coloured tiles, 7 to 8 mm thick ( square/rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tile laid over and including screed bed 15 mm thick in CM (1:6) & 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate complete all as specified and directed.
M&L for glazed ceramic coloured tiles 6-8 mm thick (square/rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm, set & jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles on vertical surfaces of wall such as dados, skirting etc over & including 10 mm thick screed plaster in CM 1:4 on stone masonry wall surfaces complete all as specified and directed by Engineer-in-charge.
M&L for 18-20mm Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding the exposed edges laid over & including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster on stone/brick wall, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
BLANK
M & L for 15mm thick rendering in CM (1:4) on stone masonry surfaces of wall finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on stone masonary surfaces in cement mortar 1:6 finished even and smooth complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces as in ceiling surfaces (CM 1:4), finished even and smooth complete all as specified & directed.
M & L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed
M & L for preparation of newly plastered surfaces of ceilings and applying three coat of white wash complete all as specified and directed
M & L for preparation of newly plastered surface of wall and applying two coat of cement base paint complete all as specified and directed.
M & L for preparation of old decorated plastered or unplastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
M & L for preparation of old decorated plastered or unplastered surfaces of ceiling and applying two coat of white wash complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.50 sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and directed.
All as per srl item No 37.00 here in before but exc 1.50 sqm and n.exc 4.00 Sqm
S&F factory made PVC solid frame of size 50mmx47mm made out of 5mm prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. square tube and fixing in opening as per specification & drawing on page 160 of SSR-2010 complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawings on page 156 of SSR Part - II 2010 complete all as specified and directed. Note :- Cadmium screws to be used for fixing and fixtures
S&F in repair factory made steel ventilator glazed and gauged (combination) with side hung/ top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame including guard bars and necessary cooler arrangement in window complete all as shown in drg No. CEBZ/TD/14/11 sh No 1/7 to 7/7 complete all as specified and directed.
S & F Aluminum alloy, anodize butt hinges, medium weight, cold rolled, ISI marked of size 100 mm, complete all as specified and directed.
S & F 150mm long aluminium, anodised, barrel tower bolt of extruded section, ISI marked complete all as specified & directed.
S&F 150 mm long extruded aluminium alloy handle fabricated type anodized complete all as specified & directed.
M & L for preparation of new steel & iron surface of width or girth exceeding 10cm and applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer complete all as specified and directed
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
M & L 40mm thick sand stone slab as in cover slab, set & jointed on joints in CM 1:4 including 25mm thick PCC 1:2:4 type, B-0, using 12.5mm graded crushed stone aggregate complete all as specified and directed.
All as per sl item No 47.00 here in before but except sand stone NOTE: Old serviceable sand stones retrieved vide Sl Item no 46.00 shall be reused.
Taking up or down steel tubing and connection 15mm bore keeping aside for reuse or removing to store complete all as specified and directed.
All as per item No. 49.00 here-in-before but 20mm dia
All as per item No. 49.00 here-in-before but 25mm dia
Supply and fix mild steel water tubing 15 mm dia galvanised medium grade including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing complete all as specified and as directed.
All as per item No. 52.00 here-in-before but 20mm dia
All as per item No. 52.00 here-in-before but 25mm dia
M & L for refixing only 15mm bore old GI tubing to walls, ceiling or laid on floor including necessary cleanig, cutting, screwing and new fittings such as elbow, Tee, union, socket, reducer etc complete all as specified and directed.
All as per item No.55.00 here-in-before but 20mm dia
All as per item No.55.00 here-in-before but 25mm dia
S&F in repair bib tap long body ,fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore of pipe complete all as specified and directed.
S&F in repair chromium plated 15mm bore stop/angle valves, fancy type, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge.
S&F in repair chromium plated 15mm bore stop/angle valves, fancy type, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions with long shank & cup (concealed type) complete all as specified and as directed by Engineer-in-charge.
S & F in repairs oval shape WHB size 400mm X 400mm fixed on granite platform with CP brass waste fitting with CP center hole mixer union, waste pipe, pvc connection, pedestal etc complete all as specified & directed. NOTE :- granite platform measured and paid separately under relevent item.
Taking out old unserviceable water closet (squatt pattern) and S & F Vitreous China, Squatting pan Orissa pattern size 580X440mm, white with integral foot rests (excluding flushing cistern and flush pipe ) with chinaware ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe and making good the floor to match the existing complete all as specified and directed.
Taking down old unserviceable flushing cistern S&F PVC valveless syphonic action type low level flushing cistern, 10 Ltrs capacity . White, with inlet ball valve, float, handle with 32mm PVC flush pipe, fixed on walls by driling holes and using PVC rawl plug of suitable size complete all as specified and directed.
Taking down old unserviceable PVC connection and S & F PVC connection, heavy duty 15 mm bore, 45 cm long with two Nos PTMT nuts at both ends of approved quality complete all as specified and directed
S & F in repair vitreous China urinal, flat back, half stall type white/ivory colour with grating and union for discharge including connection to flushing pipe and outgoing waste pipe complete all as specified and directed.
S & F in repair brass chromium plated soap dish fixed to plug with chromium plated brass screws embedded in the wall complete all as specified and directed.
S & F in repair tubular towel rail, aluminium anodised, 20mm dia ‘D’ type 60cm long between flanges complete all as specified and directed.
S&F in repair brass chromium plated shower rose of 125 mm size with swivel joints, including fixing to steel pipe or union of 15mm bore complete all as specified and directed.
S&F in repairs PVC (SWR) gully trap with grating 125/110mm dia fixed with lead joint complete all as specified and directed.
Taking down eaves gutters and rain water pipe of any size complete all as specified and directed.
Dsemolition and breaking up drain pipes of size 110mm/150mm dia(salt glazed ware, AC or Reinforced concrete) set in CM and removing from site etc complete all as specified and directed.
Taking down 110mm/100mm dia CI pipe (any size or pattern) including all fitting and removing from site complete all as specified and directed.
Taking down CI bend 110mm/75mm dia and removing from site complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls, laid in trenches or in floors complete all as specified and directed.
All as per item No. 75.00 here-in-before but 75mm bore PVC (SWR) pipe
S & F PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110 mm bore bend/shoe of any radius fixed with cement joint complete all as specified and directed.
All as per item No. 78.00 here-in-before but 75mm bore bend/shoe
S&F in repairs 110mm bore PVC (SWR) junction single (single T) or (single Y) equal or unequal with oval access door complete all as specified and directed.
M & L PCC 1:4:8 Type D-2 using 40mm graded stone aggregate as in bed of drain pipe of 150mm dia (nominal) including packing under and haunching against the size of after they are laid and tested complete all as specified and directed.
M&L for 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and as directed.
M & L for 150 mm bore salt glazed stone ware drain pipe ISI Marked laid in trenches and jointed in CM (1:1) tested complete all as specified & directed.
M & L for soakage wells including excavation in any type of soil, foundation in PCC (1:3:6), walls of honey combed fly ash brick masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of fly ash brick masonry in CM (1:6), RCC cover slab in M-25 concrete & SFRC MH cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.60m dia & 3.00m effective depth all as per drg No. CEBZ/TD/78/2011 sh No 1/2 & 2/2 complete all as specified and directed.
M & L for soakage wells including excavation in any type of soil, foundation in PCC (1:3:6), walls of honey combed fly ash brick masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of fly ash brick masonry in CM (1:6), RCC cover slab in M-25 concrete & SFRC MH cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4m dia & 3.00m effective depth all as per drg No. CEBZ/TD/78/2011 sh No 1/2 & 2/2 complete all as specified and directed.
M&L septic tank for 100 users including excavation in any type of soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole cover having 6mm plate embedded all around /fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc specified in TD drg No. CEBZ/TD/76/2011 sh No 1/2 & 2/2 complete all as specified and directed.
Taking down carefully copper / aluminium point wiring complete with concealed/surface conduit/casing caping wiring connected to wall including fittings/fixtures complete removing and making good the disturbed surface of walls/ceiling etc complete all as specified and directed.
Disconnecting electric connection and taking down old unserviceable main switches/DB's steel metal enclousers 02 ways, 4 ways, 8 ways duly fitted with MCB's /cutouts 32amps capacity including unserviceable wooden boards and making good the disturbed surface of the wall/ceiling complete all as specified and directed.
M & L for point wiring with 1.5 sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLS) cable 1100 volts grade drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher with all PVC conduit accessories with suitable size of sunk type pressed steel terminal box concealed in wall, with PVC laminated sheet top cover 3mm thick with earth continuity conductor of size 1.5 sqmm single core copper conductor multistranded cable connected to common earth dolly for One light point/fan point/bell/buzzer point controlled by one way switch 5 Amps complete all as specified and directed.
All as per item No 89.00 here-in-before but 2.5sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLS) cable 1100 volts incuding 2.5sqmm stranded copper conductor (FRLS) PVC insulated greeen in colour as continous earth conductor connected to common earth and earth dolly with all accessories one 5 pin 5/15 Amp socket on independent boardcomplete all as specified and directed
S & F switch piano type, flush button, single pole, one way 5 Amps, 240 Volts, complete all as specified and directed.
S & F switch piano type, flush button, single pole, one way 15 Amps, 240 volts complete all as specified and directed.
S&F socket out let 2 in 1, multipurpose 3/5 pin 15/16 Amp flush type complete all as specified & directed.
S&F ceiling rose surface bakelite, 3 terminals, 63.5 x 17 mm complete all as specified & directed.
S&F MCB single pole and neutral 240 volt, 10 KA, 10 to 40 Amps capacity confirming to IS 8828 of 1996 curve 'C' complete all as specified & directed.
S&F MCB single pole 240 volt 10KA, 5 to 32 Amps confirming to IS 8828 of 1996 curve 'C' complete all as specified & directed.
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S & F LED light fittings, suitable for & including 1x10 watt bulk head luminaries with connector block etc complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz complete all as specified and directed. Make :- Havells cat part No LHEOAP7UZ6W010, Bajaj Cat No : BIBWP 10W LED or equivalent as per appendix 'B'.
Supply fixing testing and commissioning of energy saving street light luminiare 15 watt LED, pressure die cast housing, heat resistant glass, IP 65 protection with suitable size of street lght bracket with clamp and fixing on wall complete all as specified and directed. Make :- Havells Cat part No. LHEWEBP7PL6S015, Bajaj Cat part No. BCLST 15W LED I5 or equivalent as per appendix 'B'.
S & F LED tube light fitting retrofit batten in acrylic linear tube (1x18 watt), 230 V for single LED tube light including 1x18 W LED retrofit bar professional CW 6500 K cover channel, bipin holder, LED power driver, connector block, etc complete with all accessories internally prewired and incuding connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. Make : Bajaj Cat part No BLRB 18 W CWC for tube BLRB - DB 118 for batten, Havells cat part No LHLDDBXEUL7Z018 (for tube) LHFYBP1TB1W20 (for batten), Syska cat part No SSK - T-8-18W (tube) SSK-TL-22 F (batten).
S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-43 DB's ,made out of sheet steel enclosure, recessed type, factory made powder coated 8 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.
M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6.00mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15mm dia medium grade GI pipe and watering pipe shall be 20mm bore, medium grade including excavation & earth work in any type of soil & disposal of sil chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover, reinforced with 8mm TMT bars 100mm C/C both ways with life hook made out of 8mm dia bars, watering arrangement with funnel and wire mesh completed all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
M/S JAGDISH PRASAD AIRUN
Jyoti enterprises
M/s SUNIL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .