Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.7 L+₹88,877.60 (8.23%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Other than L1 |
Tender Value
₹11.3 L
EMD Value
₹22,600
Closing Date
24 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Addn/Altn to War Memorial at HQ Northern Command under GE Utilities Udhampur
2020_MES_329324_3
GE/U-66/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹22,600
Yes
14 Aug 2020
1 Jun 2020
26 Jun 2020
1 Jun 2020
24 Jun 2020
10 Jun 2020
60 days
Amount
Taking out the existing unserviceable rusted LT panel board alongwith busbar, MCCBs etc of any size/capacity including disconnection, breaking PCC foundation etc and disposed off as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Taking out old unserviceable halogen light of any/any wattage and making good the distrubed surface of walls, floor to match with existing specification complete all as specified and directed by Engr-in-Charge.
S&F LED Flood Light 50 Watt with powder coated PDC Aluminium body with toughened glass visor, complete with accessories complete all as specified and directed by Engr-in-Charge. Cat Pt No- PAR0206005 Make: Polycab or equivalent in Havells/Wipro/ HPL
M&L for Thermoplastic Cable junction Boxes IP 66/67 "weather proof", for outdoor installation(with knockouts for cable entry) the junction box shall be insulated and made out of polycarbonate with glass fiber reinforced.The size in mm should not be less then 205x255x112 cat pt no. KF2525G . The polycarbonate JB shall be environment friendly, recyclable,UV resisitant, halogen & silicon free,anti acid & anti corrosive.The JB shall be rated for degree of ingress protection IP 66/67 in accordance with IEC 60529. The gasket material shall be polyurethane and the gasket shall be internally embedded. The JB shall be complies with requirements of the standard IEC 60998-1, IEC 60998-2-1, IEC 60670-22 and IEC 60670-2-5.
The JB colour according to RAL 9011. The manufacturer of junction box/ enclosure shall sumbit a copy of IEC certificate. For better safety the polycarbonate encl shall be fire retardant and self-extingushing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3, UL subject 94 for flammability V-2. It should be tested at glow wire test for 960 deg. Cent. The impact strenght of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. JB should be with one 6 amp SP and terminal set assemble by OEM. Manufacturer should submit routine test certificate for CJB/PJB. Hensel or equivalent complete all as specified and directed by Engr-in-Charge. Make: Hensel/siemens/GE power/Rittal.
Taking out old unserviceable post top lantern of any/any wattage and making good the distrubed surface of walls, floor to match with existing specification complete all as specified and directed by Engr-in-Charge.
M&L for LED post top lantern top fitting with powder coated die cast and spun aluminium with clear/opal diffuser, suitable for landscape Lighting, fo capacity 25 watt incl all accessories and connection etc complete all as specified and directed by Engr-in-Charge.
M&L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note:- All the joints shall be made with welding to get proper conductivity.
Taking out unsrviceable LT UG cable of any sizes complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts of size 16 sqmm 4 core complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two single core PVC insulated unseathed, FRLS flexible copper conductor cable of size 4 sqmm and one single core cable PVC insulated unseathed, Fr flexible copper conductor cable of size 2.5 sqmm as earth lead in & including PVC non metallic rigid PVC conduit medium grade and making good the distrubed surfaced complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, foundations of poles/stays etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. Note: - For payment purpose 18 cm thickness shall measured.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed by Engr-in-Charge.
Supply and laying GI tubing 40mm dia light grade laid in trenches/floor/fixing on pole / wall / in tarmac including necessary fittings etc complete all as specified and directed by Engr-in-Charge.
M&L Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floor and of paving not exceeding 15 cm thickness below and above ground level complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick PCC 1:4:8 type B2 using 40 mm graded aggregate as in sub base of floor etc complete all as specified and directed by Engr-in-Charge.
M&L for 25 mm thick PCC 1:2:4 type B1 using 20 mm graded aggregate as in sub base of floor etc complete all as specified and directed by Engr-in-Charge.
M&L for 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes under floor complete all as specified and directed by Engr-in-Charge.
M&L for non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
M&L for vitrified tiles, area of each tile not exceeding 0.36 sqm, 10 mm thick (square or rectangular) of superior quality as in floor surfaces set and jointed in neat cement slurry and pointed in white or closured cement to match the existing shade of tiles complete all as specified and directed by Engr-in-Charge.
M&L for vitrified coloured heavy duty (Dura stone) 300 x 300 x 8-10 mm thick and similar pattern tiles as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
M&L for vitrified coloured heavy duty exterior grade 600 x 600 x 18-20 mm thick and similar pattern tiles as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed by Engr-in-Charge.
M&L rendering 10 mm thick on fair faces of brick work or concrete surface in CM 1:4 on vertical surfaces/backing coat complete all as specified and directed by Engr-in-Charge.
M&L for 18-20 mm thick granite (of any type) machine but as in dado etc laid over cement backing coat and jointed with grey cement slurry and pointed with cement with admixture of pigment to match the shade of granite stone including grainding and polishing complete all as specified and directed by Engr-in-Charge.
Removing and fixing for existing granite granite (of any type) machine but as in dado etc laid over cement backing coat and jointed with grey cement slurry and pointed with cement with admixture of pigment to match the shade of granite stone including grainding and polishing complete all as specified and directed by Engr-in-Charge.
M&L for exterior grade coloured tiles of size 300 x 600 x 7 mm wall tiles set and jointed in neat cement and in white/coloured cement to match with the colour if tile etc complete all as specified and directed by Engr-in-Charge.
M&L for 50 mm thick PCC type B1 1:2:4 using 20 mm graded crushed stone aggregate as in plinth protection laid in alternate panels finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B1 using 20 mm graded aggregate as in coping, benching and similar work complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster and raking out joints, hacking for key, scrubbing down with water up to nay height of bldg built in cement mortar complete all as specified and directed by Engr-in-Charge.
M&L for two coat of heavy duty acrylic coating for walls water proofing (make Dr Fix It new coat) over a coat of Primer for sealer coat (Dr Fix It) with roller all as sper manufacturers instruction complete all as specified and directed by Engr-in-Charge.
Rendering 15 mm thick in CM 1:4 on fair faces of brick/concrete finished even and smooth without using extra cement inclduing water proofing compound complete all as specified and directed by Engr-in-Charge.
Supply only (LW+) water proofing liquid solution complete all as specified and directed by Engr-in-Charge.
M&L for preparing new surfaces of wall and applying two coats of weather proof exterior emulsion paint (APEX or equivalent) over primer up to any height of bldg etc complete all as specified and directed by Engr-in-Charge.
SINGH CONST CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .