Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L1 | Accepted-Finance ACCEPTED BEING L1 BIDDER | |
| 2 | L2₹54.2 L+₹7.2 L (15.3%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 BIDDER |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
2 Apr 2022, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG DIVISION PIN 793002
SPL REPAIR TO OVERHEAD CONDUCTOR INTO UNDER GROUND CABLE AT 119 INF BN (TA) AND CERTAIN MINOR WORKS UNDER GE SHILLONG
2022_MES_504858_4
GE / SHL / 72 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE SHILLONG
Please Refer Tender Document
8 documents required · 8 mandatory
₹500
GE SHILLONG
₹87,000
24 Jun 2022
19 Mar 2022
4 Apr 2022
19 Mar 2022
2 Apr 2022
19 Mar 2022
Amount
Supply, laying XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable with stranded aluminum conductor 1100-volt grade of size 185 sqmm 3.5 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed including taking down old unserviceable XLPE cable with brick protection and complete all as specified and as directed.
All as per Item No.01 above but size of XLPE cables 70 Sqmm 3.5 Core.
All as per Item No.01 above but size of XLPE cables 35 Sqmm 3.5 Core.
All as per Item No.01 above but size of XLPE cables 16 Sqmm 3.5 Core.
All as per Item No.01 above but size of XLPE cables 10 Sqmm 4 Core.
Excavation in trenches in soft / loose soil n.exc 1.5m wide and n.exc 1.5m in depth; for foundation etc. n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out etc complete all as specified and directed by Engineer in Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick as in any type of soil etc complete all as specified and as directed by Engineer in Charge.
Removing excavated materials (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed by Engineer in Charge.
M&L for Sand cushioning with dry clean river sand for protection/covering of under ground cable in trenches complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured for payment.
Supply lay in trenches fly ash bricks, laid flat in trenches as protection to LT XLPE cable complete all as specified and as directed.
Dismantling and taking down ACSR conductor of any type, any size after disconnectiong all incoming and out going electrical connection etc complete all as specified and directed.
Dismantling insulators of any type, any size after disconnectiong all incoming and out going electrical connection etc complete all as specified and directed.
Disamantling and taking down cross arms, bracing supports etc., after disconnectiong all incoming and out going electrical connection etc complete all as specified and directed.
S&F GI tubing 100 mm dia light grade with all necessary GI fittings, fixed on pole/wall, ceiling or floor, or lay in trenches under road/drain crossing with necessary clamp or hook if required complete all as specified and as directed. NOTE: wherever cable is to be fixed on pole through protection pipe, the existing pole coping be broken and new coping to be done. The item will be measured and paid under respective item of Schedule.
S&F GI tubing 40 mm dia light grade with all necessary GI fittings, fixed on pole/wall, ceiling or floor, or lay in trenches under road/drain crossing with necessary clamp or hook if required complete all as specified and as directed. NOTE: wherever cable is to be fixed on pole through protection pipe, the existing pole coping be broken and new coping to be done. The item will be measured and paid under respective item of Schedule.
Supply, install , testing and commissioning of outdoor/indoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly painted with powder coated paint and aluminium bus bar 600 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board witnin two fit area:- (officer ) INCOMING (a) MCCB 4 pole 400 Amps, 415 V, 36 KA-01 No (b) Changeover switch 4 pole 400 Amps, 415 V, 36 KA-01 No (c) LCD multifunctioning meter-01 No (d) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type (e) CTs 100/5 amps-set of three (f) Aluminium bus bar 600 Amps-03 Nos and 300 Amsp -01 Nos (g) Internal Wiring for panel incl insulators, sleeves etc OUTGOING (a) MCCB 4 pole 160 Amps, 415 V, 25 KA-04 No (b) MCCB 4 Pole 100 Amps, 415 V, 25 KA-02 No (c ) Timer abd Contector 63 Amps -01 Nos Set
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly painted with powder coated paint and aluminium bus bar 300 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS channel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board within two fit area:- INCOMING (a) MCCB 4 pole 200 Amps, 415 V, 25 KA-01 No (b) LCD multifunctioning meter-01 No (c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type (d) CTs 100/5 amps-set of three (e) Aluminium bus bar 300 Amps-03 Nos and 200 Amsp -01 Nos (f) Internal Wiring for panel incl insulators, sleeves etc OUTGOING (a) MCCB 4 pole 100 Amps, 415 V, 25 KA-04 No (b) MCCB 4 Pole 63 Amps, 415 V, 25 KA-3No (c ) Timer and Contactor 63 Amps -01 Nos Set
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly painted with powder coated paint and aluminium bus bar 300 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board witnin two fit area:- (Mandir) INCOMING (a) MCCB 4 pole 200 Amps, 415 V, 25 KA-01 No (b) LCD multifunctioning meter-01 No (c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type (d) CTs 100/5 amps-set of three (e) Aluminium bus bar 300 Amps-03 Nos and 150 Amsp -01 Nos (f) Internal Wiring for panel incl insulators, sleeves etc OUTGOING (a) MCCB 4 pole 100 Amps, 415 V, 25 KA-03 No (b) MCCB 4 Pole 63 Amps, 415 V, 25 KA-3 No (b) MCCB 4 Pole 40 Amps, 415 V, 25 KA- 4 No (c ) Timer and Contector 63 Amps -01 Nos Set
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly painted with powder coated paint and aluminium bus bar 300 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS channel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board within two fit area:-(Main) INCOMING (a) MCCB 4 pole 400 Amps, 415 V, 25 KA-01 No (b) LCD multifunctioning meter-01 No (c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster (d) CTs 100/5 amps-set of three (e) Aluminium bus bar 300 Amps-03 Nos and 200 Amsp -01 Nos (f) Internal Wiring for panel incl insulators, sleeves etc OUTGOING (a) MCCB 4 pole 250 Amps, 415 V, 25 KA-03 No (b) MCCB 4 Pole 160 Amps, 415 V, 25 KA-3 No (c ) Timer and Contactor 63 Amps -01 Nos Set
Supply, install , testing and commissioning of indoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly painted with powder coated paint and aluminium bus bar 600 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS channel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board within two fit area:- (PH) INCOMING (a) MCCB 4 pole 400 Amps, 415 V, 50 KA-01 No (b) LCD multifunctioning meter-01 No (c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster (d) CTs 100/5 amps-set of three (e) Aluminium bus bar 600 Amps-03 Nos and 300 Amsp -01 Nos (f) Internal Wiring for panel incl insulators, sleeves etc OUTGOING (a) MCCB 4 pole 200 Amps, 415 V, 25 KA-04 No (b) MCCB 4 Pole 160 Amps, 415 V, 25 KA-04 No
M & L for Automatic Power Factor Correction (APFC) Panel outdoor type for 3 Phase, 415 V & 50 Hz system of capacity 50 KVAR, 6 stage type with suitable size incoming MCCBs complete all as specified and directed.
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , of size 90cm x 90cmx30cm, CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly painted with powder coated paint and aluminium bus bar 300 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board witnin two fit area:- INCOMING (a) MCCB 4 pole 200 Amps, 415 V, 25 KA-01 No OUTGOING (a) Aluminium bus bar 300 Amps-03 Nos and 200 Amsp -01 Nos
Supply & fixing factory made IP-65 (Dust and power jet proof according to IEC60529) transparent street light junction box of size 340x160x90 made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant , fire retardant , fire retardant having high impact totally insulated, UV resistant ) having high grade gasket made of polyurethane including one nos MCB SP 6 Amps for control street light with two cable gland for cable size 10/16 sqmm etc., and fixing on pole with MS flat iron of size 20X3mm with necessary nut & bolts complete all as specified and directed by Engr-in-Charge. Make: Hensel /Sintex
M&L for PVC Cable of Three core 2.5 Sq.mm size PVC insulated , un sheathed , multi stranded Aluminium conductor cables in 20 mm PVC conduit including clamp and connecting up to street light fitting, complete, all as specified and directed by Engr-in-charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth strip 32X3.15mm by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete including taking down old unserviceable one, all as shown in Electrical Plate No 3 of SSR part -I.
M&L PCC, type D2, (1:4:8, using 40mm graded stone aggregates) as in PCC/Road cutting /installation area and foundation of pole etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC casing capping with accessories, incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch. Note:- Switch, socket and fan regulators to be measured and paid for separately. PVC Conduit confirming to IS 9537 part I & III. Note (All chases will be cut by chase cutter only)
Supply and fix switch piano (ISI marked) Single pole 240 volts, 5Amps all as specified and directed by Engr-in-charge. Make- Havells/anchor/ Legrand.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
S & F Exhaust fan 230 volts, sweep 250mm, copper winding made of sturdy engineering plastic with louvers shutter including making all electric connection, including cutting of rectangular hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall, complete all as specified and as directed by Engr-in-charge. Make: Bajaj/Havell's/Orient/ Crompton
S & F Exhaust fan 230 volts, sweep 150mm, copper winding made of steel with louvers shutter including making all electric connection, including cutting of circular hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall, complete all as specified and as directed by Engr-in-charge. Make: Bajaj/Havell's/Orient/ Crompton
M&L, testing, installation, commissioning of Kitchen Exhaust System with SS Hood with SS 304 Baffle, Triple layer baffle filter 6 feet, Width 40-80(cm), 180-200(cm), Suction Capacity 800-1200(m3/h), Air Flow: 1800m3/h, Frequency: 50Hz to 6Hz, High Velocity Hood, 18 Gauge Stainless Steel Duct, Duct Velocity 1750 FPM, PDCA Motor, Voltage Input 250 V, Noise Level 60db, GI Ducting for Hot air Ventilation 60 sqft. Corrosion Resistance, Commercial Exhaust Fan18inch Dia./ EPC, Commercial Exhaust fan 450 mm sweep with 1400 RPM / including all Civil work for fixing system, make hole and replastering existing wall with wall colour coding with Basic Civil work required including fixing of Duct and complete Electrical wiring as required for system running complete, all as specified and directed by Engr-in-charge. Make- EPC
M/S Mani Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .