Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹37.0 L+₹5.0 L (15.5%)Rejected-AOC FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-AOC ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
18 Jun 2021, 3:00 pmClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
REPAIR MAINT OF SEWAGE LINE DRAINS SEPTIC TANKS COMPOUND WALL FENCING GATE PCC PATHWAY PAVING AREA HARD STANDING AND ALLIED WORKS INCL REPAIRS TO ROAD KERB STONES AND ROAD FURNITURE AT TECH AND RESI AREA AT ORDAQA ARMT AND R AND D E ENGRS DIGHI PUNE
2021_MES_444691_1
GE I R AND D GNR TOKEN 15 OF 2021 2022
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE I R AND D GIRINAGAR PUNE 411025
₹88,000
Yes
29 Jun 2021
21 May 2021
19 Jun 2021
21 May 2021
18 Jun 2021
4 Jun 2021
21 May 2021 - 2 Jun 2021
Amount
PART-I (REPAIRS TO SEWAGE LINE) Repairs to leakage from inlet/outlet of any dia of pipe of over head water storage tanks by using M-seal or tightening of checknut etc complete all as directed by Engr in Charge.
Removing of blockage from 'S' trap/'P' trap/ Nahani trap/floor trap by flushing or by sucking by suction pumps at GF/ Ist/ IInd/ IIIrd floor or any floor including cleaning the line upto 1st manhole complete all as directed by Engr-in-charge.
Removel of Trees/Plants complete incl roots any dia, any masonary at any hight. including applying root killer chemical as per manufacturer’s instructions and making good disturbed portion with PCC 1:2:4 Type B0 (using 12.5 mm graded stone aggregate)in cm 1:3 and finishing the surface to match with existing surface and removing of rubbish out side MoD land/area complete all as directed.
Cleaning of Sewage line of dia 150 mm bore pipe lines of any description in between two consecutive manholes to the entire satisfaction of Engineer-in-Charge and testing by pouring water from manhole to manhole.
All as per Srl item No 4 above but 200 mm bore pipe.
All as per Srl item No 4 above but 300 mm bore pipe.
Cleaning of septic tanks of the following capacity by dewatering all the water, taking out the sludge/night soil. Flushing the septic tank with clean water in order to remove all stacked mud/sludge etc cleaning the choked inlets. Outlets of septic tank removing all the sludge to outside MD land including surface dressing of the septic tank around the distance not less than 3 mtr all specified and directed. Septic tank of 300 to 600 user capacity. Note:- The night soil / sludge including water obtained by cleaning of the septic tank shall be taken out in closed container and disposed off outside MD land by excavating a pit of adequate size and depth not exc.1.5m
Cleaning of manhole of any description, any size and any depth including removing sludge and deposited outside MD land etc complete all as directed by Engineer-in- Charge.
Cleaning of Gully Traps of any description, any size and depth including removing sludge and deposited outside MD land etc complete all as directed by Engineer-in- Charge.
Demolition of PCC as in foundation of below ground level n.exc 15 Cm thick etc all complete.
M&L PCC (1:4:8) type D-1 using 40 mm graded stone aggregate as in sub bases, 75 mm thick finished even & rough to receive finishing layer, etc. complete.
M&L for 50mm thick sand cusion under layer of floor
Material and labour for machine pressed precast concrete interlocking paver block any shape, colour , size and pattern as approved by GE conforming to IS 15658-2006 of 60 mm thick, M-35 Grade & glossy finish with white or coloured cement and pigment all in specified and directed.
M&L for Cement concrete tile glossy finish 25 cm x 25 cm x 22mm thick machine pressed set and including 15mm thick screed bed CM(1:6), jointed and pointed in neat cement slurry in floor with white cement & pigments and cut and polished.
Dismantling posts or struts (Wood, Steel or RCC), any section embedded in concrete, brick work etc. including taking out embedded portion and making good disturbed ground.
Dismantling of fencing any description and location
S&F for MS angle posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc ; flat/Angle iron ( for securing wire mesh etc ) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe- 410-0 or Fe 310-0.
Supply only PVC coated chain link MS galvanised fencing of size 50mm x 50mm, 3mm thick dia, weight not less than 2.20 Kg/Sqm, fixed to the M S Angle frame etc complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, GI mesh size 50mm x 50mm , 3mm dia
S&F MS flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0
Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes,Drains & Post hole etc. getting out in hard dense soil.
Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes,Drains & Post hole etc. getting out in soft/disintegratted rockl.
Demolition of plain cement concrete (Un reinforced) in benching and surface channels, drains,coping, Plinth protection and Manholes above ground level.
S&F TMT bars 8mm dia cut to lengths bent to shape required including cranking, bending spirally for hooking and binding with MS wire (annealed) not less than 0.9 mm dia etc all as specified & directed for MH covers/Drain covers etc complete.
Demolition of precast concrete block masonry or stone masonary built in cement mortar
M&L for PCC block masonry with soild blocks Type C1 1 :3:6 (20mm grade agg) exc 10 cm in width and setting in CM 1 :6
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete sufaces including finished even and smooth using extra cement.
M&L for plain cement concrete 1:3:6 Type B1 using 20mm graded aggregate as in coping including form work etc complete.
M&L for 75mm thick cement concrete type C2 1:3:6 using 40mm graded aggregate as in flooring/ plinth protection and finished concrete surfaces even & smooth without using extra cement.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl, forms mould, mi-tred/stopped ends etc.
Demolition of cement concrete bed in haunching and breaking up RCC drain pipe 150 mm dia set in cement mortar of the following dia.
Demolition of cement concrete bed in haunching and breaking up RCC drain pipe 200 mm dia set in cement mortar of the following dia.
M&L for plain cement concrete 1:3:6 Type C2 using 40mm graded aggregateas in foundation, filling in mass concrete for manholes, drains, Septic tank & Soakwell etc.
M&L for plain Cement concrete 1:2:4 Type B1 using 20 mm graded aggregate as in benching and surface channel of Manholes.
M&L for concrete bed in P.C.C. 1:4:8 type D2 (using 40mm graded aggregated) to 150 mm dia drain pipes including packing under and haunching against the sides of the pipes after laying & testing.
M&L for concrete bed in P.C.C. 1:4:8 type D2 (using 40mm graded aggregated) to 200 mm dia drain pipes including packing under and haunching against the sides of the pipes after laying & testing.
Returning filling in soft/loose soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc all complete.
M&L for reinforced concrete NP2 drain pipes 150 mm dia confirming to IS laid in trenches and jointed in CM 1:2 all as specified & directed by EIC
M&L for reinforced concrete NP2 drain pipes 200 mm dia confirming to IS laid in trenches and jointed in CM 1:2 all as specified & directed by EIC
M & L for cutting in to existing manhole for connectiing new drain 150 mm bore , making good to pipe & renderring cutting out existing benching for & forming branch channel in cement concrete ( 1:2:4) type B1 smooth finished & reforming benching as requierd.
M & L for precast cement concrete type B1 ( 1:2:4) 20 mm greded aggregate for manhole/drain cover slab setting in C:M (1:6)
M & L for mild steel round bars 10mm dia and over as in handles over manhole cover slab
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling Water Tanks & removing from site, capacity of tanks exc 250 litres & n. exc. 500 Litres capacity each
Dismantling Water Tanks & removing from site, capacity of tanks 500 ltr and n exc 1000 ltr
S/F Rotational moulded polyethelene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position all as specified in SSR Pt-I, 500 litre capacity.
S/F Rotational moulded polyethelene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position all as specified in SSR Pt-I, exc 1000 ltr capacity.
Taking up or down steel tubing 15mm bore dia & connections incl cleaning for re-fixinging or removing to store.
Taking up or down steel tubing 20mm bore dia & connections incl cleaning for re-fixinging or removing to store.
S/F steel water tubing medium grade GI with all fittings & fixed complete to walls & ceilings or laid on floors of bore of pipe 15 mm.
S/F steel water tubing medium grade GI with all fittings & fixed complete to walls & ceilings or laid on floors of bore of pipe 20 mm.
Refixing of old steel water tubing & connecting in new or old position (wall, ceiling & floor, etc.) of bore of pipe 15 mm.
Refixing of old steel water tubing & connecting in new or old position (wall, ceiling & floor, etc.) of bore of pipe 20 mm.
supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 15 mm bore pipe
S/F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm dia including taking down old pipes
S/F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75 mm dia including taking down old pipes
S/F in repair PVC (SWR) bends any radius 110 mm dia
S/F in repair PVC (SWR) bends any radius 75 mm dia
M&L for cleaning the Accessable/Inaccessable roof tops/Terraces etc including removing of Silt/Sand accumulated, small plants and leaves, mud etc. blocking the rain water pipes including removing the rubbish from roof tops, out side the MoD land.(Residential & Technical bldgs of R&DE(E) (a) Area exc 50Sqm to n.exc 200Sqm
(b) Area exc 200Sqm to n.exc 500Sqm
(c) Area exc 500Sqm to n.exc 1000Sqm
M&L for preparation of old painted surfaces concrete surface of any description exc 10cm width or girth and applying two coats of Synthetic enamel paint Block/Yellow colour for Kerb stones etc Completed all as specified and directed
M&L for preparetion of new steel surfaces exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer.
PART - II (REPAIRS TO ROAD) Repair to pot holes any depth n.exc 1.00 sqm each incl sweeping free from dust and mud or water, scoring sunken surface in roads, paths etc cutting around edges to at least 30mm in depth & making good by filling in screened and graded road metal, watering & well ramming including supply of road metal and applying tack coat at 5 kg per 10 sqm & M&L for premixed bituminous carpet 30mm thick (consolidated ) with 0.34cum of stone chipping mixed with 18.25 kg of binder and rolled & compacted to required camber and gradient & depth of pot holes exc 30mm.
Applying tack coat of hot paving bitumen of grade VG-10 conforming IS:W-73:2006 of 05Kg/10Sqm as directed.
M& L for premix bituminious macadum with using 4% binder content by weight of total mix with paving bitumen grade 60/70 rolled and compacted to required gradient and camber with 8 to 12 tonne power roller all as specified and directed by Engr-in-Charge (Consolidated thickness 75mm or less).
M&L for preparing existing black top surfaces of bituminous by wire brushing for removing caked, mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags or with compressed compressor air blower to remove all loose dirt and applying evenly a tack coat of VG-10 conforming IS:W-73:2006 paving bitumen @ 5 kg per 10 sqm using mechanical sprayer, operated by hot pressure mechanism and M&L 30mm thick (compacted) bituminous premixed semi dense asphaltic concrete using 5.5% binder contant by weight of total mix using VG-30 grade paving bitumen, spread with self propelling mechanical paver and rolled and compacted to required camber and gradient with using 8 to 12 tonne power road roller complete all as directed by Engr-in-Charge.
M&L for Applying one coat of synthetic enamel paint on existing Road side kerb stone surfaces including preparation of existing surfaces all as specified & as directed.
M&L for marking 2.50 mm thick centre line, stop line, dashes, arrows, brackets & similar work on road surfaces as per IRC pattern with thermo plastic paint of approved quality & make with 8% glass beads laid at temperature 1600 C with a special applicator machine complete all as per manufacturer’s instructions & traffic diversion arrangement. (Make-CMS Bombay/Shivalik Prime-Chandigarh/Ritactor-Meerut/SN Industries-Delhi/Reliance Thermoplast, Delhi/CMS Traffice System Ltd, Mumbai)
S&F in repairs Cata- stud ( Cat's eye) made out of ABS plastic with beams two side fixed with high intensity grade retro-reflective sheeting in Red/Yellow colour having fixing with hot melt bitumen adhesive and complete in all respect Make - 3M/Road Star/Dark Eye or equivalent as approved by GE.
Mukund Engineers and Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .