Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.5 L+₹18,918 (0.51%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹37.9 L+₹56,178.50 (1.51%)Rejected-Finance R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹43.5 L+₹6.2 L (16.6%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
4 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN 913862 c/o 56 APO
Special repair to bldg No T12A including certain revenue work and minor work and certain special repair under AOR of AGE B/R Dett A of GE 862 EWS
2021_MES_480617_1
GER-54/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹85,000
Yes
22 Nov 2021
8 Oct 2021
6 Nov 2021
8 Oct 2021
4 Nov 2021
22 Oct 2021
60 days
Amount
Sch 'A' Part-I (B/R works) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 450x350x7mm/ 300x200x7mm (premium quality) on vertical surface such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10 mm thick backing layer of cement plaster in cement mortar (1:4) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
M&L for 75mm thick PCC type C-2, 1:3:6 (using 40mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight) complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.5 Sqm and n.exc 4 Sqm each and removing to store complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for stone walling of random rubble masonry (except stones, using old unserviceable stone after cleaning), uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 20 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M&L for 4mm thick designer cement fibre ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section, in any position (framed work) complete all as specified and directed.
S&F for Roof trusses (framed), trussed, purlins, cranes gantries, , rails and fastening and heavy brackets framing (beam, tea, angle, channel or flat section) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
S&F for Mild steel work as in wind ties using flat iron including all necessary drilling bolting, riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long and slote 16 to 20mm complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar (1:6) on stone masonry finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar (1:4) on stone masonry (external surface) finished even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for formwork to sides and soffits of roof beam, floor beam, lintel etc. for rough finished surface of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 5mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for reinforced Cement concrete type B1 (1:1½:3) (using 20 mm graded stone agg.) in roof beams, floor beam, lintel etc. complete all as specified and as directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC (1:3:6) type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F for factory made MS tubular Box type window (double rebate and double shutter) of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge, corner welded to form a solid fused welded joint, handles shall be of z section welded with openable frame box steel section used in outer frame, shutter frame and central frame shall be ERW secton of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section of steel window to provide suitable arrangement of using tower bolt. Glazed, gauzed window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures without glazing bars including 3mm thick sheet glass ordinary quality and stainless steel wire mesh of 0.36mm nominal dia and average width of aperture 1.4 mm etc complete all as specified and directed.
M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
S&F for 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F for Second class hard wood(Hollock) small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each, complete all as specified and directed.
M&L for plain cement concrete type B-1 , 1:2:4 (using 20mm graded stone aggregate) as in coping, benching, hold fasts, water troughs, bed block, foundation and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
S& F for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F for 150 mm long extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
S&F for 150mm long aluminium anodized barrel tower bolts extruded section all as specified and directed.
S&F for 200mm long aluminium alloy, anodised, sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
M&L for preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
S&F for 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
M&L for preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of wall care putty complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for foundation etc and n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for hard core of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed.
M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete complete all as specified and directed.
M&L for reinforced Cement concrete type B1, 1:2:4 (using 20 mm graded stone agg.) in foundation inlcuding rafts, fotings, foundation beams, plinth beams, base for columns etc basement slab under reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in lintel, beam etc complete all as specified and directed.
M&L for reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in column, pillars, piers, struts etc complete all as specified and directed.
M&L for reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, columns , roof, landings, shelves and the like complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, column etc for rought finished surface of concrete complete all as specified and directed.
M&L for formwork to sides of concrete foundation, footing, bases of colums, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar (1:4) on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specifed and directed.
M&L for preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces on ceiling and applying three coats of white wash complete all as specified and directed.
M&L for steel ventilators (factory made) with top hung shutter including hinges, steel peg stay complete all as specified and directed.
M&L for Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L for Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 No, floor door stopper, anodised aluminium snap beading, screws etc including powder coating of any colour (thickness of powder coating not less than 50 micron) complete all as specified and directed.
M&L for 5.5mm thick sheet glass, ordinary quality fixed to aluminium doors in square exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for 12mm thick prelaminated partical board, interior grade both side decorative choice lamination fixed to aluminium doors or as in cup board cabinets similar works complete all as specified and directed.
M&L for Brass mortice lock vertical type 100mm long with 4 levers complete all as specfied and directed.
S&F for 150mm long aluminium alloy, anodised, sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F for 125mm long extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
S&F for 125mm long aluminium anodized barrel tower bolts extruded section all as specified and directed.
M&L for 3.0 mm thick frosted sheet glass ordinary quality and glazing with oil putty and steel pins or wooden beads in squares not exceeding 0.50 square metre in each pane, complete all as specified and directed.
M&L for 15mm dia bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe complete all as specified and directed.
M&L for Viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) and inlcuding set of CP jet with PVC pipe of superior quality complete all as specified and directed.
S&F for PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
M&L for 15mm bore stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
M&L for 15mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed complete all as specifed and directed.
S&F for 100mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors/walls complete all as specified and directed.
S&F for 100mm bend (any radius) cast iron complete all as specified and directed.
S&F for 100mm dia cast iron P or S trap complete all as specified and directed.
S&F for 110mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed..
M&L for 110mm dia PVC SWR bends complete all as specifed and directed.
S&F for vitreous China wash basin, white, flat back, size 550x 400mm including cutting for and pinning in ends of brackets or errecting stand, angle bracket (but exclusive of fixing of supply waste pipe, tap) complete all as specified and directed.
S&F for 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, brass chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F for 110mm dia PVC (SWR) 'S' trap complete all as specifed and directed.
S&F for soap dish any type fixed to plugs with chromium plated brass screw complete all as specified and directed.
S&F for 125mm shower rose fancy type, swivel type chromium plated suitable for 15mm bore and fixed complete all as specified and directed.
S&F for 15mm stop valves, cast copper alloy screwed down high byut fancy type, chromium plate pressure with long shank and cup and fixed (concealed type) complete all as specified and directed.
M&L for water proofing treatment on non-accessible roof surface horizental and verticle surfaces in following sequence through manufacturer/authorised applicator of the manufacturer complete all as specified and directed by the Engr-in-Charge:- (a) Rendering 10mm thick in Cement mortar (1:3) on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slope from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed by Engr-In-Charge. (iii) Water proofing compound shall be measured and paid for separately.
S&F for Vitreous china bowl urinal flat back of size 465x355x265mm white (minimum) including, waste pipe, coupling, floor trap, incuding necessary fitting complete all as specified and directed by the Engineer-in-Charge.
S&F for push type any colour high pressure of PTMT screwed for iron pipe and fixed suitable for urinals(minium weight 15mm-50 gms) complete all as specified and directed.
M&L for new GI Tee of size 40x40x25mm dia including necessary threading, screwing, tail piece, short pieces, jointing material etc after cutting of existing GI pipe line of 40mm dia for connection of inserting purpose complete all as specified and directed.
S&F for 25 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F for 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed.
M&L for 25mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
M&L for 20mm dia gun metal, gate/globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
M&L for construction of septic tanks exc in ordinary soil foundation in PCC 1:2:4, brick work in cement mortar (1:4), RCC slab covers inlcuding RCC precast manhole cover having 6mm plate embedded all and sludge chambers reinforced cover with angle iron frame vent shaft around/fibre etc complete for 50 user complete all as specified and directed and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2.
M&L for construction of soakage well 1.2 Mtr dia and 3 M deep including excavation and earth work in any type of soil, PCC 1:3:6 in foundation, walls of honey combed masonry with top ring of M-30 concrete including intercerpting chamber and screen chamber made of Brick masonry in CM 1:4, RCC cover slab in M-30, interconnecting pipes of RCC complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe complete all as specified and directed.
M&L for 150 mm internal dia Salt-Glazed stone ware drain pipes grade 'A' laid in trenches over concrete bedding jointed in cement mortar (1:1) and tested complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed.
M&L for precast RCC 1:2:4, type B1 as in landing, cover slab, chajjas etc and similar articles with plain faces set in cement mortar (1:6) complete all as specified and directed.
Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete etc complete all as specified and directed..
M&L for machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 80mm thick, M-40 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
M&L for rolling and consolidating formation old surfaces in cutting with power roller of capacity 8 to 12 tonne complete all as specified and directed.
M&L for 150mm thick compacted thickness water bound mecadam (in two equal layers each layer to be compacted separately) with coarse aggregates of granite, trap or basalt stone of grading 2 (63 to 40mm size), spread, rolled with power roller 8 to 12 tonne to required gradient adn camber completeall as specified and directed.
S&F for polythene film 150 micron thick laid over and including a coat of bitumen primer @ 0.30 to 0.50 kg/sqm complete all as specified and directed.
M&L for flexural cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less all as specified and directed.
M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primeed and sealed with sealing compund grade-A thickness of concrete slab 250mm including providing 20mm dia mild steel dowel bars 50cm long (25cm in each slab) with ferrules, spaced at 300mm cetners, including boring formwork and preformed filler for dowels complete all as specified and directed.
M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 300 mm bore drain pipe complete all as specified and directed.
M&L for 300mm dia reinforced concrete pipes, class NP2, laid in trenches and jointed as complete with collors all as specified and directed.
M&L for PCC (1:3:6), type C-2 using 40mm graded stone aggregates as in surface channel/foundation complete all as specified and directed.
M&L for excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
Removing of excavated material (soil) to a distance exc 250 mtr not exceeding 500 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC casing & caping of 25mm width (Medium grade double locking system) complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit)
Description all as per Serial item No 122 above but for one 5 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch complete all as specified and directed.
Description all as per Serial item No 122 above but for one 5 pin 6 Amp socket outlet on same board controlled by one 6 amp switchcomplete all as specified and directed.
Description all as per Serial item No 122 above but for one 6 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 16 Amp, 240 volts complete all as specified and directed.
M&L for Socket outlet 5 pin 5 amp flush type complete all as specified and directed.
M&L for Socket outlet 6 pin 5 amp and 15 Amp flush type complete all as specified and directed.
M&L for Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
M&L for Lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 9 watt complete all as specified and directed.
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole, 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
S&F for street light bracket made out of 40mm bore GI tubing medium grade made to shape 1.2 mtr long bent to shape 120 degree and fixing with two numbers of MS clamp of 50mm x 6mm thick flat iron including , nuts, bolts, washer duly painted with synthetic aluminium paint two coats over a coat of red oxide primer complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete after taking down old unserviceable earthing all as specified.
M&L for LED Tube light fitting, complete with 1x 18 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed. (Make :- Havells cat No LUMILINEBS18WLED865SPCWH/ Crompton Greaves, Cat No LCTLN-18-CDL or equivalent of philips.
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed. (Make :- Havells Cat part No HEXAFT10WLED857SSYMBOPC/Crompton Greaves Cat No. LBHP-10-CDL or equivalant of Philips)
S&F for exhaust fan of size 380mm heavy duty metalic body complete with louver 1400 RPM speed 230 volts AC electrical operated 50 HZ complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 2.5 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including non rigid PVC casing and caping (medium grade dobule locking system) of size 20mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 2.5 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note : - 02 run of 2.5 sqmm single core copper conductor cable and 01 run of 2.5 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit.
S&F for sheet metal enclosure with socket plug top and MCBs single pole with one MCB 240 volts 20 amps complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
M&L for 40mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
S&F for LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed (Make:- Crompton, Model No FREEDOM NEO LSTS-45-CDL-M or Havells, Cat No ENDURA PEARL NEO SL45WLED757PASYTOPC)
S&F for street light bracket made out of 32mm bore GI tubing medium grade made to shape 1.2 mtr long bent to shape 120 degree and fixing with two numbers of MS clamp of 50mm x 6mm thick flat iron including , nuts, bolts, washer duly painted with synthetic aluminium paint two coats over a coat of red oxide primer complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply, Laying, connecting and testing in replacement of service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete after taking down old unserviceable service cable all as specified and directed.
S&F for weather proof flat twin core cable with stranded aluminium conductor of size 4 Sqmm complete all as specified and directed.
Supply and errect in truly vertical position steel tubular swaged pole 09 mtr long with cast iron base plate 6mm thick, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, including painting one under coat with anti corrosive primer and two coats of aluminium paint and in the botton above ground level alternative white & black strips of 30 cm width upto 1.5 mtr above ground level and marking pole No complete all as specifed and directed. Note :- Earth work, excavation and PCC in foundation, coping etc shall be measured and paid separately under respective items.
S&F for LED street light fitting 60 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fitting of any type complete all as specified and directed. (Make:- Crompton, Model No. NEXUS NEO,LSTP-60-CDL-HPM or Havells Cat No. ENDURA PEARLPLUSSL60WLED757PASYTOPCASTHO)
M&L for sheet metal terminal box of size 30cm x 30cm x15cm made out of 2mm thick CRCA sheet, factory made power coated consisting of Aluminum bus bar of size 20x3mm -04 Nos (3phase & 1 Neutral) and MCB SP 10 Amps 01 No Complete all as specified and directed. (Make:- Sintex/Hansel).
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
S&F for Air termination single pointed aluminium rod 12mm dia and 300mm long complete wiht fixing arrangements to insulate air termination from pole complete all as specified and directed.
S&F for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as required at site complete all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the alumn strip comes in direct contract with pole. 2. Al strip will be fixed epoxy base insulators of suitable size and rates were deemed to be included in quoted prices).
S&F for galvanised iron strip 32 x 6mm buried in ground for loop earthing complete all as specified and directed.
S&F for test point terminal block made of gun metal size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass screw complete as in repair all as specified and directed.
M&L for 25mm dia galvanized steel tubing (light grade) with complete all fittings for supporting of air termination rod including supply and welding of 12mm dia nuts and bolts for fixing of air termination rod and the pipe shall be fixed on roof with 200mmx200mm PCC block of PCC (1:2:4) type B-1 using 20mm graded stone aggregate and all rates are including in the quoted rate complete all as specified and directed.
M&L for 20mm dia galvanized steel tubing (light grade) with complete all fittings for supporting of air termination rod including supply and welding of 12mm dia nuts and bolts for fixing of air termination rod and the pipe shall be fixed on roof with 200mmx200mm PCC block of PCC (1:2:4) type B-1 using 20mm graded stone aggregate and all rates are including in the quoted rate complete all as specified and directed.
Supply, fix, testing and commissioning refrigrator, electric driven (single phase), single door cooling capacity upto 310 litres. BEE 5 star rated, copper coil fixed with invertor compressor, with automatic defrost arrangement and metalic colour including all accessories complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 270V with output voltage stabilized at 230V with accuray of ± 2.5% and capacity of 1 KVA complete all as specified and directed.
M&L for switch socket combination 2 in 1, 5 pin 5 amps and 15 amps flush type complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
RAJINDER CHOUDHARY
vijay kumar
CHAND CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .