Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC PROTHRAPUR SRI VIJAYA PURAM SOUTH ANDAMAN 744105 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC Accept | |
| 2 | L2₹5.9 L+₹1.5 L (33.8%)Rejected-Finance ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹5.9 L+₹1.5 L (35.2%)Rejected-Finance ROOM NO 01 1ST FLOOR SIMA TRADING BUILDING SURVEY NO 268 GARACHARMA VILL SRI VIJAY PURAM 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not recommended due to category not found | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended due to category not found |
| Sl No | Description | Qty | Unit | M/s Gurunath Construction L3 | RPG AND COMPANY L2 | RISING ENGINEERING L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR including required gas charging complete all as specified and directed.
Note:- (a) The cost of compressor oil, remote with batteries, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine.
(c) Quoted rate inclusive of copper piping upto 3 mtr and refrigerant gas upto 3 mtr piping.
(d) Additional cost of copper tubing (>3 mtr), refrigerant gas (>3mtr) & bracket for mounting outdoor unit shall be measured and paid seperately. | 3 | Each | 1,15,000 ₹3,45,000 | 1,12,000 ₹3,36,000 | 1,02,000 ₹3,06,000 Lowest |
| 2.00 | Supply & Fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket completewith one single pole MCB 20 Amps complete all as specified. | 3 | Each | 2,150 ₹6,450 | 1,950 ₹5,850 | 1,750 ₹5,250 Lowest |
| 3.00 | M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and directed. | 3 | Each Set | 2,500 ₹7,500 | 2,350 ₹7,050 | 2,150 ₹6,450 Lowest |
| 4.00 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed. | 3 | Each | 34,900 ₹1,04,700 | 38,500 ₹1,15,500 | 4,050 ₹12,150 Lowest |
| 5.00 | Supply and fixing of Copper tubing of size 1/2" or 1/4" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed. | 6 | RM | 2,850 ₹17,100 | 2,450 ₹14,700 | 2,000 ₹12,000 Lowest |
| 6.00 | Supply and fixing of Copper tubing of size 3/8" or 5/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed. | 6 | RM | 2,850 ₹17,100 | 2,450 ₹14,700 | 2,200 ₹13,200 Lowest |
| 7.00 | M&L for submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 4 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification and one run of 4 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed.
Note :
(a) Three run of single core cable with one run of PVC conduit/PVC casing caping and accessories will be measured as one length.
(b) The quoted rate inclusive of following:-
(i) Proper colour coding is to be followed as per IS specifications.
(ii) Test certificates of cables is to be submitted before commencement of work/claiming for payment.
(iii) Wiring shall be concealed/on surface with rigid PVC conduit medium grade / PVC casinf caping of suitable size as per site requirement. | 30 | RM | 295 ₹8,850 | 300 ₹9,000 | 235 ₹7,050 Lowest |
| 8.00 | Supplying and fixing rigid non-metallic PVC conduit 25 mm dia inclusive of all fittinngs as accessories complete all as specified. | 6 | RM | 110 ₹660 | 105 ₹630 | 90 ₹540 Lowest |
| 9.00 | Supply and charging refrigerant gas environmental friendly refrigerant gas as per OEM design for gas charging complete. | 2 | Kg | 3,100 ₹6,200 | 2,680 ₹5,360 | 2,500 ₹5,000 Lowest |
| 10.00 | Supply, installation, testing and commissioning of electrical chimney, wall mount type, filter less maximum suction 1400 Cum/Hr, driven by 130W BLDC motor with input voltage 220V, 50 Hz complete all as specified and as directed. | 1 | Each | 52,000 ₹52,000 | 51,500 ₹51,500 | 47,550 ₹47,550 Lowest |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
25 Feb 2026, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8721/E8- PROVISION OF THREE NUMBER SPLIT AIR CONDITIONER CAPACITY 02 TON FOR DSC DINING HALL AND PROVISION OF ELECTRIC CHIMNEY AND BOOSTER PUMP AT INS UTKROSH UNDER AGE EM-I OF GE MINNIE BAY, SRI VIJAYA PURAM
2026_MES_751187_1
8721/E8
Open Tender
Civil Works
Item Rate
30 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
13 documents required · 13 mandatory
₹300
Yes
GE, Minniebay
₹9,000
Yes
8 Apr 2026
4 Feb 2026
27 Feb 2026
4 Feb 2026
25 Feb 2026
18 Feb 2026
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR including required gas charging complete all as specified and directed. Note:- (a) The cost of compressor oil, remote with batteries, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine. (c) Quoted rate inclusive of copper piping upto 3 mtr and refrigerant gas upto 3 mtr piping. (d) Additional cost of copper tubing (>3 mtr), refrigerant gas (>3mtr) & bracket for mounting outdoor unit shall be measured and paid seperately.
Supply & Fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket completewith one single pole MCB 20 Amps complete all as specified.
M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
Supply and fixing of Copper tubing of size 1/2" or 1/4" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply and fixing of Copper tubing of size 3/8" or 5/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
M&L for submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 4 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification and one run of 4 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed. Note : (a) Three run of single core cable with one run of PVC conduit/PVC casing caping and accessories will be measured as one length. (b) The quoted rate inclusive of following:- (i) Proper colour coding is to be followed as per IS specifications. (ii) Test certificates of cables is to be submitted before commencement of work/claiming for payment. (iii) Wiring shall be concealed/on surface with rigid PVC conduit medium grade / PVC casinf caping of suitable size as per site requirement.
Supplying and fixing rigid non-metallic PVC conduit 25 mm dia inclusive of all fittinngs as accessories complete all as specified.
Supply and charging refrigerant gas environmental friendly refrigerant gas as per OEM design for gas charging complete.
Supply, installation, testing and commissioning of electrical chimney, wall mount type, filter less maximum suction 1400 Cum/Hr, driven by 130W BLDC motor with input voltage 220V, 50 Hz complete all as specified and as directed.
Supply, fixing, testing & commissioning of booster pump with motor suitable for 230 V, 50 Hz, 1 phase system, 2800 RPM, head range 6 to 28 mtr having capacity 0.5HP complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 2.5 sqmm (FRLSH), PVC conduit medium grade/ PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing one run of 2.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting for socket outlet 16Amps independed complete all as specified and as directed.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.
S&F modular switch one way 16 Amps, 1 module complete all as specified and as directed.
S&F modular socket, 2/3 pin 6/16 amps, 2 module complete all as specified and as directed.
stage.html
html • 0.06 MB
technical_841321.pdf
techsummary_841321.pdf
finance_841321.pdf
BOQ Comparative Chart
xlsx
finsummary_841321.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8721TENDER.pdf
Tender Documents • 0.82 MB
BOQ_841321.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .