Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99,870Accepted-Finance | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹1.3 L+₹28,835 (28.9%)Accepted-Finance | L2 | Accepted-Finance 2nd Lowest | |
| 3 | L3₹1.4 L+₹42,219 (42.3%)Accepted-Finance | L3 | Accepted-Finance 3rd Lowest |
Tender Value
₹1.8 L
Closing Date
3 Feb 2021, 10:00 amClosed
EE WSD APWD
EE WSD APWD Port Blair
Supplying, installation testing and commissioning of Air Conditioners and Providing IEI in Command and Control Centre established in the Directorate of Transport Building First Floor Port Blair SW Providing IEI
2021_APWD_2157_1
99/NIT/WSD/2020-21
Open Tender
Electrical Works
Works
45 days
Port Blair
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
9 Feb 2021
29 Jan 2021
3 Feb 2021
29 Jan 2021
3 Feb 2021
29 Jan 2021
29 Jan 2021 - 3 Feb 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
a) Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
c) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
a) 2 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 5/6 A switch
b) 15/16 A switch
c) 3 pin 5/6 A socket outlet
d) 6 pin 15/16 A socket outlet
c) Telephone socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
a) 1 or 2 Module (75mmX75mm)
b) 12 Module (200mmX150mm)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
a) 1 Pair
Supplying of AC ceiling fan 1200mm sweep Make :-USHA TECHNIX FLAIR W/O REG WH 1 Star C /Bajaj/Crompton/Ortem/Khaitan/Havells/Orient or equivalent complete with all accessories etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of single phase Power unit modular AC box with mini modular MCB power unit with 20A SP MCB with ISI plug top ( with box) on surface or in recess complete with connections, testing and commissioning etc as required.Make:- Anchor Code No.98488/Legrand/Havells/Indoasian or equivalent.
Supplying and fixing of Motor Starter switch 20A Make:- Anchor code No.20427/ Legrand/Havells/Indoasian or equivalent complete with connections ,testing and commissioning etc as required.
Supplying of 12W LED Square recess PDC aluminium housing downlights Make:- C & S Cat.No.CARINA-SQ/12W/W, LTCRSLM12HPLEDSQ/W, 12W white/Havells/ Crompton/ Bajaj/Philips or equivalent complete with all accessories etc as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 6 way, Double door
b) 12 Way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying, installation, testing & commissioning of conventional photoelctric smoke detector, low current draw, operates on 12 and 24 VDC systems, remote alarm test features, easy mainenance, remote LED option, approved to EN54-7:2000 (Amenndment 1) Brand :- System Sensor Model:- ECO 1003/Qutak Security devices or equivalent etc as required.
M/s G K Construction
M K ENGINEERING
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .