GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIR/REPLACEMENT OF OTHER MISC E/M WORKS AT 22 GARHWAL, IHQ OF MOD (ARMY) CAMP, WARDEC, 16 JAKRIF AND 16 KUMAON, TARAPORE OFFRS ENCLAVE AND DUNDEHERA MIL STN AND OTHER MD AND OTM ACCN UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2026_MES_796636_1
GE/TOKEN-62/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹98,000
Yes
30 Oct 2026
30 Oct 2026
23 Nov 2026
30 Oct 2026
20 Nov 2026
13 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | S&F in repair of existing Solar Flat Plate Collector of 100 LPD capacity, including repair/replacement of damaged components of the collector, fabricated from 2.0 mm thick sheet, complete with heat exchanger, as required at site, complete all as specified and as as directed. | 40 | Each | - | - |
| 3 | S&F in repair of existing Solar Evacuated Tube Collector, including supply and fixing of double-walled glass evacuated tubes of approved quality, conforming to the following dimensions Outer tube diameter: 47 ± 0.7 mm, Tube length: 1500 ± 5 mm, Inner tube diameter: 33.4 mm, Minimum tube wall thickness: 1.60 mm, as required at site, complete all as specified and as as directed. | 37 | Each | - | - |
| 4 | S&F in repairs repair of existing hot water storage tank with heat exchanger type, of 300 LPD capacity, forming part of the solar water heating system, having low-carbon steel tank with epoxy enamel coating, minimum 1.6 mm thick, provided with 50 mm thick CFC-free PUF insulation and covered with duly insulated pre-coated steel sheet, as required at site, complete all as specified and as as directed. | 35 | Each | - | - |
| 5 | Material and labour for de-scaling of Solar Flat Plate Collector/Solar Evacuated Tube Collector of 200/300/1000 LPD capacity, by approved chemical descaling process, including removal of deposits of temporary hardness, scale and other mineral deposits from the internal surfaces/passages of collector tubes and associated components and include dismantling/opening wherever required, circulation/application of suitable approved descaling chemical, flushing with clean water, neutralisation and thorough cleaning of the system, including brazing of leaking joints wherever required, replacement of minor sealing materials and making good the affected portions. The collector shall thereafter be tested for leakage and proper functioning and restored to service, complete in all respects as per site requirement, specifications and as directed by the Engineer-in-Charge. | 382 | Each Job | - | - |
| 6 | Material and labour for de-scaling of heat exchanger tank of solar water heating system up to 500 LPD capacity, by approved chemical descaling process, including removal of deposits of temporary hardness, scale and other mineral deposits from the internal surfaces/passages of the heat exchanger and associated tubes and include opening/dismantling wherever required, application/circulation of suitable approved descaling chemical, flushing with clean water, neutralisation and thorough cleaning of the system, including brazing of leaking joints wherever required, replacement of minor sealing materials and making good the affected portions. The heat exchanger tank shall thereafter be tested for leakage and proper functioning and restored to service, complete in all respects as per site requirement, specifications and as directed by the Engineer-in-Charge. | 118 | Each Job | - | - |
| 7 | Taking down and removing existing old/unserviceable GI/steel water tubing of 15 mm, 20 mm and 32 mm bore, including disconnecting and removing all connected fittings, supports and accessories, and making good the affected portions, complete in all respects as specified and as directed by the Engineer-in-Charge. | 1,920 | RM | - | - |
| 8 | Fixing only of 20 mm bore medium-grade steel water tubing, including all necessary fittings, supports, clamps and accessories, fixed to walls and ceilings or laid in floors, complete in all respects as specified and as directed by the Engineer-in-Charge. | 270 | RM | - | - |
| 9 | Fixing only of 15 mm bore medium-grade steel water tubing, including all necessary fittings, supports, clamps and accessories, fixed to walls and ceilings or laid in floors, complete in all respects as specified and as directed by the Engineer-in-Charge. | 350 | RM | - | - |
| 10 | Fixing only of 32 mm bore medium-grade steel water tubing, including all necessary fittings, supports, clamps and accessories, fixed to walls and ceilings or laid in floors, complete in all respects as specified and as directed by the Engineer-in-Charge. | 150 | RM | - | - |
| 11 | Supply and fixing of 32 mm bore medium-grade GI tube, including all necessary fittings such as bends, elbows, tees, short pieces, connectors, caps, plugs, unions and other accessories, securely fixed to walls and ceilings or laid in floors, complete in all respects as specified and as directed by the Engineer-in-Charge. | 350 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TenderpagesT62.pdf
Tender Documents • 0.79 MB
SOC62.pdf
Additional Documents • 0.37 MB
BOQ_893539.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .