SE Guwahati Building Circle-II Chandmari
SE office Guwahati Building Circle-II Chandmari
Construction of DEOC Building, Kamrup, Amingaon
2021_PWBNH_20889_1
SE/BII/DDMA/313_DEOC_Amingaon
Open Tender
Civil Works - Building
Item Wise
240 days
Amingaon, Guwahati
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,950
Assam State Road Board Maintenance (Roads) Fund
₹1.3 L
Yes
SE office Guwahati Building Circle-II Chandmari
3 Mar 2021
6 Feb 2021
18 Feb 2021
6 Feb 2021
17 Feb 2021
6 Feb 2021
9 Feb 2021
180 days
Amount
Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1)C) UNIFORM PILE(II) Concrete Grade M25 v) Pile dia 400 mm
Extra for using admixture & plasticiser(b) Concrete Grade M25 vi) Pile dia 400 mm
Empty boring for specified diameter piles from ground level to cut-off level. f) Pile dia 400 mm
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc).(A) TMT bar made of Primary producer (From Primary producer)
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified upto a depth of 2.00 m below the existing G.L. - In Ordinary Soil
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified upto a depth of 2.00 m below the existing G.L. - In hard/dense Soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. ii) With hill sand obtained by truck carriage loading and unloading, and carriage to the site of work.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately) - In prop. 1:3:6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level - M20 grade concrete
(B) In Super-structure i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. - M20 grade concrete a) In Ground Floor
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing - M20 grade concrete a) In Ground Floor
b) In First Floor
iii) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band - M20 grade concrete a) In Ground Floor
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. - Using 38mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: i) Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face a) In Ground Floor
b) In First Floor
ii) Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties for depth not exceeding 1.0M. a) In Ground Floor
b) In First Floor
c) In 2nd Floor
iii) Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like for floors etc. upto 200mm in thickness. a) In Ground Floor
b) In First Floor
iv) Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. a) In Ground Floor
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete - Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level - In proportion 1:5.
112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) - In cement mortar in proportion 1:4 (1 cement:4 sand) a) In Ground Floor
b) In First Floor
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).ii) Of size 600mmx600mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).ii) Of size 300mmx450mm and above
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (iii) Deluxe Quality.(i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
10 mm thick Cement plaster in single coat for plastering on celling and soffits of stairs up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed - In cement mortar 1:3 a) In Ground Floor
b) In First Floor
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for plastering under Ceramic Tile / Vitrified Tile flooring up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed - - In cement mortar 1:4 a) In Ground Floor
b) In First Floor
Grading roof for water proofing treatment with Cement concrete 1:2:4 - 1 cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size)
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).(a) 1.25mm thick sheet.(v) Size 165mm x 60mm (Double rebate)
Providing fitting and fixing SS (304 grade) railingmade of hollow tubes, channels, plates ets...... As per approval of Engineer in Charge
Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x75 mm x3.55mm),300x12 mm Aluminium Tower bolts-2nos,150 mm Aluminium Door handle-2nos, 300x16mm- Aluminium Sliding Door bolts-2nos and Door stopper with rubber stopper-1nos with necessay screws and furnishing with moulded timber beading of size 25mmx15mm around the panels complete as per drawing .A).With Teak wood / Sissu wood.(ii) 35 mm thick.
Providing, fitting and fixing M.S. grill of requiredpattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. ii) Ornamental Grill - Fixed to Brickwork/P.C.C/R.C.C.
SOR 12.12.2: Supplying and installing uPVC- Sliding Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass. a) 2 track sliding ii)4 panel with 5mm clear float glass a)Side hung and Top hung windows and ventilators.ii)5mm frosted glass
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) - Thickness = 1.5 mm thick
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper with ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter - Surfaces over 100mm in width or girth for General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level) - TMT-Corrosion Resistant Steel (Fe-500) reinforcement bar (TATA/SAIL) a) In Ground Floor
b) In First Floor
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete - With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete - With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof/ JSW Steel/ Spectrum or equivalent as directed by the Departement.(iii) 0.50 mm thick
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
Providing SUN ROCK HIGH CTS Tiles (Pavers blkock tiles of concrete grade M30 or above of approved quality size, shape of specification thickness over a levelling bedding layer…..(c) ) 50 mm thick
Supply, Installation, Fixing of ABC stored Pressure Fire Extinguisher with built – In Pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle as per IS:13849 with ISI mark. (10 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
(A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals) @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals) mixed with cement in the ratio 1:2 as final coat.
Providing fitting and fixing white vitreous EWC( without pedestal) P Trap water closet (European type W.C pan 400mm high) of Parryware make with seat and lid ,CP brass hinges and rubber buffers ,as directed and specified.
Supplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)Auto Cister 10 litre (Cat. No.C61002)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately).(v) Cascade NXT 550 x 440 with short Pedestal and spring set (Cat. No.C0404/C0379/C8298)
Providing fitting and fixing Decorative Mirror complete as directed and specified.
Providing fitting and fixing Glass Shelf complete as directed and specified.(iii) Jaquar make
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.(i) Jaquar Make(a) Continental (Cat.No.ACN-1331N)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified.(a) Jaquar make .(iii) Queen's (Cat.No.AQN-7721)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. i) 110mm dia.
ii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. i) 110mm dia.
ii) 75mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc.as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm dia
ii) In exposed surfaces or in trenches - 75mm dia
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. i) In exposed surfaces or in trenches - 110mm x 110mm
ii) In exposed surfaces or in trenches - 75mm x 75mm
Providing fitting and fixing 75mm dia. PVC cowel of ISI make complete as directed and specified.
Providing fiting & fixing C.P.Grating to the floors complete as directed and specified 100mm dia i) 75mm dia
ii) 100mm dia
Providing and fixing S.F.M.C. Brand 3 layer (Outer green coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R (Poly propylene- random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (A) Exposed or in trenches i) PN-16 Pipe,25 mm OD,SDR-7.4
ii) PN-16 Pipe,40 mm OD,SDR-7.4
(B) Concealed pipe with cutting chases & making good the walls i) PN-16 Pipe,16mm OD,SDR-7.4
ii) PN-16 Pipe,20 mm OD,SDR-7.4
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) - Jaquare make - Continental /Clarion - 2-Way bib cock
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) - Jaquar - Continental / Clarion - 15mm dia (Concealed stop cock extra heavy with adjustable wall flange)
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed - Jaguar make - Continental Pillar cock (ISI) / Pillar cock
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes i) 2000 Lt capacity - Sintex make
Labour for erecting and placing PCVCTank over the stagging of 5.00m up to 8.00m complete as directed. a) 2000 litre capacity
Wiring for light/fan /call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system complete. Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in flat 25mm ISI marked casing 'n' capping system.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) Richa, Bentec, Adhunic, V-Guard make) 4 way SPN double door
6 way SPN double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (ABB, Schneider MG, legrand, Hager make) 40A
Supply, installation & testing of G.I. earth station with perforated 50 mm dia and 3.00 Metre long heady duty G.I. pipe with necessary 50 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 65 mmx50 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 Kg and Charcoal 64 Kg in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2 - module type
Supplying including and fixing of following Moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of department. 1-3 module Surface Moulded PVC boxes
8 module surface Moulded PVC boxes
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 3 module
8 module
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)
Supplying,fitting fixing of LED Batten tubes high quality aluminium extetruded with decorative and caps connection with 1.5 mm2 1 core PVC insulated round copper conductor as required and directed by the department. BN 021C LED 20 S PSU CW GR S2
Supplying,fitting &fixing of LED bulb non-dimmable in the existing batten /angle holder as required and directed by the department. Prima Series Bulb 5 W
Prima Series Bulb 7 W
Prima Series Bulb 9 W
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 2 Core A2XWaY A2XFaY 6.00 Sq.mm 2 Core armoured U.G. cable
Providing, supplying and installation of Base Isolation System and complete as specified and as per direction of the reputed/ certified agency/ organization as decided by the Deptt.
RANJIT KUMAR CHAKRABARTY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .