Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹14,500
Closing Date
5 Dec 2024, 3:00 pmClosed
The Director NIOT
NIOT Campus, Velachery-Tambaram Main Road , Narayanpuram, Pallikarnai, Chennai
Electrical work for NEW 60kVA UPS Power in MB/FF/RW/CMC Store room at NIOT Campus.
2024_NIOT_835259_1
NIOT/SnP/EnM/29850/2024-25
Open Tender
Electrical Works
Works
NIOT CAMPUS, CHENNAI
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹14,500
5 Dec 2024
18 Nov 2024
5 Dec 2024
18 Nov 2024
5 Dec 2024
18 Nov 2024
18 Nov 2024 - 4 Dec 2024
Amount
Supply and fixing of 200A 4Pole 36kA MCCB with all accessories along the existing UPS Main panel outgoing feeder. Location: Utility-I/FF/UPS Main Panel. Make: L&T
Supply and laying of 3.5C x 120sqmm XLPE insulated Aluminium armoured 1.1kV graded UG cable.along the closed cable trunch/Hump Pipe/excavation area as required as per site condition. Location: * Utility-I/FF/UPS Main Panel 200A feeder to MB/FF/RW/CMC 60kVA UPS room new UPS incomer panel. Make: polycab/RR kabel/KEI/SN cab
Supply and Making of end termination with doble compression Gland (3.5C x 120sqmm) suitable crimping lugs.The gland should be double earthed by suitable copper wire and earth strip. Location: * Utility-I/FF/UPS Main Panel- 1no. * MB/GF/LW/CMC 60kVA UPS New Incomer panel - 1no. Make: Comet / Comex
Excavating all types of soil (manually) up to depth 0.75 metre to 1 metre and width of 100 mm to 300 mm, 100 mm river sand cussioning for cable, laying brick above the sand cussioning and back filling the excavated earth in the trench.
Removing and refixing of Existing panel board (2000mmx300mmx1500mm) with necessary suitable size heavy MS channel support to the height of 750mm from the existing floor level.The channel should be painted with two coats of redoxide primer and over and above with another two coats of black enamel paint.The job includes welding, cutting and allied works such us removing of the existing cable to required height,reglanding,termination with suitable supports if required at site.
Taking out existing CC interlocking paver blocks from footpath/central verge,including removal of rubbish etc., and Re laying old cement concrete interlocking paver blocks of any design/shape laidin required line,level,curvature,colour and pattern over and including 50mm thick compacted bed of coarse sand,filling the joints with fine sand etc., all complete as per the direction of engineet-in-charge.(Old CC paver blocks shall be supplied by the department free of cost) Note : Existing paver block should be removed without breakage.
Supply,laying and end termination of 5Rx35sqmm (3Runs for 3phase & 2Runs for UPS neutral) FRLS PVC insulated copper conductor graded to 1.1kV ,single core multistrand cable with 2" rainforced PVC hose along the Floor/wall as required as per site condition.The job including of providing of suitable copper lugs and PVC gland also. Location : * Incomer panel to 60kVA UPS. * 60kVA UPS to Outgoing panel. Make:polycab/KEI/Kundan/RR/SN cab
Supply,laying and end termination of 2R x 50sqmm FRLS PVC insulated copper conductor graded to 1.1kV ,single core multistrand cable in existing 1¼" size PVC Conduit along the wall as required as per site condition.The job including of providing of suitable copper lugs. Location : * Incomer panel to 60kVA UPS. * 60kVA UPS to Outgoing panel. Make:polycab/KEI/Kundan/RR/SN cab
60kVA UPS Incomer Panel Supply,Erection,Testing and Commissioning of indoor type Panel,wall mounting type,dust and vermin proof,constructed of 14SWG CRCA sheets,compartmentalised,modular type and powder coated as per specification below. Incomer :- 1) 200A 4P 50kA MCCB - 1no 2) Current transformer rated 200/5A,10VA/CI 1.0 meter - 3no's. 3) Digital Multi data Meter with RS485port - 1no. 4) LED type RYB indication lamps with control fuses - 1set. Outgoing :- 1) 125A 4P 36kA MCCB - 3nos. 2) One set 200A TPN 50kA for 1sec copper Bus Bars with colour coded heat shrinkable PVC sleeves,DMC/SMC bus bar supports and suitable earth bus and accessories as required as per the TNEB norms. Note :- 1) All breakers should have shunt release arrangement. 2) All breakers should be with rotary handle mechanism. 3) The size of the outgoing compartment for 125A shall not be less than that for 200A. 4) Each outgoing compartment size shall be designed for accommodating enhanced instrumentation in future. Make:- 1) Panel board - CPRI Fabricators 2) MCCB - L&T / GE / SIEMENS (D-shine model 3) CT - KAPPA / L&T 4) METER - KRYKARD/L&T/schneider/Enercon 5) LED INDICATOR - TEKNIP/L&T/SIEMENS Location: MB/FF/RW/60kVA UPS room(CMC store room).
60kVA UPS Outgoing Panel Supply,Erection,Testing and Commissioning of indoor type Panel,wall mounting type,dust and vermin proof,constructed of 14SWG CRCA sheets,compartmentalised,modular type and powder coated as per specification below. Incomer :- 1) 200A 4P 50kA MCCB - 1no 2) Current transformer rated 200/5A,10VA/CI 1.0 meter - 3no's. 3) Digital Multi data Meter with RS485port - 1no. 4) LED type RYB indication lamps with control fuses - 1set. Outgoing :- 1) 63A 4P 36kA MCCB - 2nos. 2) 40A 4P 36kA MCCB - 2nos. 2) One set 200A TPN 50kA for 1sec copper Bus Bars with colour coded heat shrinkable PVC sleeves,DMC/SMC bus bar supports and suitable earth bus and accessories as required as per the TNEB norms. Note :- 1) All breakers should have shunt release arrangement. 2) All breakers should be with rotary handle mechanism. 3) The size of the outgoing compartment for 63A shall not be less than that for 125A. 4) Each outgoing compartment size shall be designed for accommodating enhanced instrumentation in future. Make:- 1) Panel board - CPRI Fabricators 2) MCCB - L&T / GE / SIEMENS (D-shine model 3) CT - KAPPA / L&T 4) METER -KRYKARD/L&T/schneider/Enercon 5) LED INDICATOR - TEKNIP/L&T/SIEMENS Location: MB/FF/RW/60kVA UPS room(CMC store room).
TOTAL WITHOUT GST
GST at 18%
INDIRA ENTERPRISES (BID ID -3131754)
AADHI ELECTRICAL AND CONSTRUCTION (BID ID -3130540)
Bhavani Electricals (BID ID -3128067)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .