Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹48.5 L+₹3.0 L (6.58%)Rejected-AOC 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹52.9 L+₹7.4 L (16.2%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L3 | Rejected-AOC Not lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur
Provn of certain sanctioned work part-1 under GE Bharatpur
2020_MES_364430_1
8958/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE Bharatpur
Class E category a(I)
8 documents required · 8 mandatory
₹500
Yes
GE Bharatpur
₹90,000
Yes
14 Oct 2020
27 Jul 2020
21 Aug 2020
27 Jul 2020
18 Aug 2020
12 Aug 2020
60 days
Amount
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft/loose soil complete all as specified and as directed by Engineer in Charge
Excavation in trenches, not exceeding 1.50 meter wide and not exceeding 1.50 meter in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 square meter on plan and not exceeding 1.50 meter in depth and getting out in soft/ loose soil complete all as specified and as directed by Engineer in Charge
Material and labour for Cement concrete in foundations, filling and mass concrete type D2 1:4:8 using 40 mm graded stone aggregate including compaction of concrete, curing etc. complete all as specified and as directed by Engineer in Charge
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/ loose soil complete all as specified and as directed by Engineer in Charge
Form work to sides of concrete foundations, foottings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar works; vertical or to batter for rough finished surfaces complete all as specified and as directed by Engineer in Charge
RCC M-25 in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc; basement slabs, under reamed piles and mass concrete complete all as specified and as directed by Engineer in Charge
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer in Charge
S&F mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in strips, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer in Charge
S&F mild steel TMT bars 06 to 08 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips
Form work to sides of pillers, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed by Engineer in Charge
Reinforced cement concrete (design mix M-25) in columns, pillars, piers, posts and struts complete all as specified and as directed by Engineer in Charge
Form work to sides of concrete foundations, foottings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar works; vertical or to batter for rough finished surfaces complete all as specified and as directed by Engineer in Charge
Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 meter mean radius built in cement sand mortar 1:6 including curing, racking of joints etc. complete all as specified and as directed by Engineer in Charge
RCC M-25 in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc; basement slabs, under reamed piles and mass concrete complete all as specified and as directed by Engineer in Charge
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exceeding 200 mm thick (Horizontal or slopping) complete all as specified and as directed by Engineer in Charge
Reinforced cement concrete (Design Mix M-25) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.complete all as specified and as directed by Engineer in Charge
S & F powder coted Anodised Aluminium frame for door,windows,vantilators,partion wall with one or more rebates including joining cleats for fixing etc complete all as specified and as directed by Engineer in Charge
S & F powder coated Aluminium door shutter,aluminium section weighing 0.55kg/RM & for partion wall aluminium section weighing 1.4Kg/RM including necessary joining cleats zlazing clips,rubber neoprene packing handles 2 Nos in each door,hinges anodized aluminium snap beading screw etc complete all as specified and as directed by Engineer in Charge
S&F three track three panels powdre coated sliding window with fly proof SS wire meash (02 Nos glazed & 01 No wire mesh panels) made of frame 92x44mm & sash 32x60 mm both having wall thickness 1.9+ 0.2mm and single glazing bead of appropriate dimension (area of window upto 1.75sqm), including aluminium extruded interlock, EPDM rubber gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), GI fasteners 100x8 mm size for fixing frame to finished wall and necessary stainless steel screw etc. proflie of frame and sash shall be mitred cut and fusion welded at att corners, including drilling of holes for fixing hardware's after fixing frame the gap between frame and adjustment finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all as per approved drawing and section of engineer in charge.
S&F in double action floor spring hydraulically regulated made up of minium 1.25 mm thich aluminium alloy sheet foundation box,main body with stainless steel cover,govering pivot made of brass,other parts made of mild steel heavy duty and fixed.complete all as specified and as directed by Engineer in Charge
S&F Aluminium extruded section body door closer hydranlicelly regulated designation no 3 universal type suitable for door shutter up to 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.complete all as specified and as directed by Engineer in Charge
S&F Sheet glass 5.50mm thick ordinary quility and glazing with oil putty in square n.exc 0.50 sqm in each pane complete all as specified and as directed by Engineer in Charge
Providing and fixing 12 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-inCharge. Pre-laminated particle board with decorative lamination on both sides complete all as specified and as directed by Engineer in Charge
15 mm thick rendering on fair faces of brick work or concrete burfaces in cement sand mortar 1:6 as in internal surfaces of walls finished fair even and smooth. complete all as specified and as directed by Engineer in Charge
5 mm thick cement sand mortar 1:4 using water proofing compound over 10 mm thick rendering in cement sand mortar 1:6 as in plaster to external surfaces of walls complete all as specified and as directed by Engineer in Charge
Supply only integral water proofing compound complete all as specified and as directed by Engineer in Charge
5 mm thick rendering on rough faces of brick work or concrete burfaces in cement sand mortar 1:3 as in RCC surfaces of ceilling finished fair even and smooth.complete all as specified and as directed by Engineer in Charge
Material and labour for preperation of surfaces and applying three coats of white wash to ceilling complete all as specified and as directed by Engineer in Charge
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of over 3mm putty wall care putty approved shade on walls by hand roller all as specified & directed by Engineer-in-Charge
M & L for Preperation of surfaces and applying two coats of cement base paint to external surfaces of walls complete all as specified and as directed by Engineer in Charge
Preperation of surfaces and applying two coats of synthetic enamal paint over a coat of red oxide primer to steel surfaces complete all as specified and as directed by Engineer in Charge
M&L for Vitrified Light Shade double charged ceramic tiles 10 mm thick (Square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm , over 10 mm thick screed bed in CM 1:4 in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed by Engineer in Charge
75 mm thick PCC 1:4:8 using 40 mm graded stone aggregate as in sub base under floor over rammed earth complete all as specified and as directed by Engineer in Charge
Material and labour for filling under floors or in foundation including watering and consolidation etc complete all as specified and as directed by Engineer in Charge
Material and labour for treating the top surface of filled earth at the rate of 5 liters of emulsion per square meter of surface. complete all as specified and as directed by Engineer in Charge
50 mm thick PCC 1:3:6 as in plinth protection over 75 mm thick brocken stone aggregate hard core over rammed earth. complete all as specified and as directed by Engineer in Charge
M7L for broken crushed stone aggregate as in hardcoreof guage n.exc 63 mm, deposit, spread & levelled in layer, watered & rammed to a true surface complete all as specified and as directed by Engineer in Charge
Material and labour for treating the soil under plinth protection at the rate of 5 liter of emulsion per square meter of surface area. complete all as specified and as directed by Engineer in Charge
Material and labour for anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 liter per linear meter including drilling and plugging holes etc in apron. complete all as specified and as directed by Engineer in Charge
M&L Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the rati of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge Note : The roof has to be completly cleaned before applying the water proofing of roof.
M&L for screed bed or bedding layer 15 mm thick in cement mortar 1:4 mixed with water proofing compound as per manufactoring instruction, finished even and smooth without using extra cement over cement slurry over existing roof @3 kg/sqm . WPC Shall be meashured and paid seperatly complete all as specified and as directed by Engineer in Charge
M&L for providing precast cement concrete 1:2:4 type B1 20 mm graded aggregate as in landings, cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves, and similar articals with plain faces including chamfers, weatherings, throatings etc and set in cement mortar 1:4 complete with joints to match except blocks or slabs. complete all as specified and as directed by Engineer in Charge
Supply and fixing mild steel rolled section such as angles etc. As in purlins, rafter confirming to grade Fe 410-O or 310-O including one coat of sho coat of red oxide complete all as specified and as directed by Engineer in Charge
S&Fin repair of PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, ISI marked of 110mm bore. complete all as specified and as directed by Engineer in Charge
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in flooring 100 mm thick finished even and smooth with using extra cement complete all as specified and as directed by Engineer in Charge
M&L for fixing Powder coated Manglore tiles profile sheet aluminium zinc coating GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. complete all as specified and as directed by Engineer in Charge
M&L for removing excavated materials n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point in soils complete all as specified and as directed by Engineer in Charge
S&F aluminium anodised grill DG-202/MG-107 of Deco Grill including all fixtures of approved make complete all as specified and as directed by Engineer in Charge Note : (i) Make shall be of M/S Decogrill of M/S associated or equivalent as approved by GE (ii) Min Thickness of anodized shall be 15 Microns
M&L point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe size not less than 20 mm dia with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface with cadmium plated screws including suitable size of PVC boards/ existing sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor (In green colour ) to common earth and connected to earth dolly complete all as specified and directed for the following :- (a) One light point controlled by one way switch
(b) One fan point controlled by one way switch.
(c) One 3 pin 6 Amp switch socket outlet on the same board with other switches
(d) One 3 pin 6 Amp switch socket outlet on the independent board
(e) One bell/buzzer point controlled by one push button.
All as per item No 49 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps switch socket outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly.
All as per item No 49 above but with multi stranded copper conductor cable 4 Sqmm size for sheet metal enclosure including 4 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.(Note for item No 3 :-Each circuit of 4 sqmm point wiring catered One point only Hence rate should quote accordingly.
S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type multi purpose flush type 230 volt complete all as specified and as directed by Engineer in Charge
S&F switch socket combinatin 2 in 1, 16 Amp flush type multi purpose 230 volt complete all as specified and as directed by Engineer in Charge
S&F switch piano flush button single pole one way 6 Amps 230 volt grade complete all as specified and as directed by Engineer in Charge
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board complete all as specified and as directed by Engineer in Charge make : Anchor code No 3290 penta or equivelent in Legrand.
S&F step type electronic fan regulator EME type 450 watt complete all as specified and as directed by Engineer in Charge make : Anchor code No 50440 penta or equivelent in Legrand.
M&L Bell multi musical type 230 volts grade.complete all as specified and as directed by Engineer in Charge
S&F Bell push flush type 5 Amps 230 volts grade. complete all as specified and as directed by Engineer in Charge
M&L concealed submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit with all PVC accessories. complete all as specified and as directed by Engineer in Charge
S&F Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated copper bus bar,SPN 8 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make -L&T ( Exora series)/Cat Part No 607711 of legrand /NBKRENSNDD08 in Schnedier or equivalent in Make Siemens
S&F MCBs with GI hardwaer of following capacity complete all as specified and as directed by Engineer in Charge:- (a) MCB SP 240 volts 10-40 Amps
(b) MCB SPN 240 volts, 40 Amps
(c) MCB isolator 240 volts, 40 Amps
M&L Recess mounted 2x2 luminaire 36 W comprises of thermally conductive material complete with all accessories internally pre-wired and including connecting to ceiling rose with three core flexible copper conductor cable of size 1Sqmm complete all as specified and as directed by Engineer in Charge Make: Havells Code No : LEDDRIVER30V34WTWA or equivalent in Philips/Wipro.
S&F Linear LED T8 tubular lamp of 20 watt with extruded aluminium body, PC diffuser and inbuilt driver with Batten suitable for LED T8 lamps , complete with all accessories internally pre-wired and including connecting to ceiling rose with three core flexible copper conductor cable of size 1Sqmm complete all as specified and as directed by Engineer in Charge Make Cropmton Cat Part No:LTT8-20+DMLN1LT8-16, OR Havells cat No - REGALBATTENT8UPTO2X22WDSBSWH+ HOTONULTRA2.01213T8SSTL20WLED865SPC / equivalent in Philips
M&L batten holder insulated with back plate including suitable size of PVC round block.
S&F sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of SP 20 Amps, 240 volts.complete all as specified and as directed by Engineer in Charge Make- L&T, Havells, Legrand complete all as per specified by Engr-in-charge.
Cutting chases,pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing steps cills,sunshades,shelves lintel etc.and cutting chases for concealed water tubing or concealed conduit wiring etc,and making good cutting not exc 10 cm girth on stone concrete block or slab walls complete all as specified and as directed by Engineer in Charge
S & F street light GI bracket of 0.6 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole as directed.
S&F street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers with other complete necessary fixing arrangements on pole complete all as specified and as directed by Engineer in Charge
S&F 20 watts LED street light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source with warranty option of 5 years and suitable drivers etc and connecting with 4.0 sq mm multistranded aluminium conductor PVC insulated twin core weather proof cable from fittings to over head lines or to the jucntion box and fixing to complete all as specified and directed, Make :- Crompton Cat NoLST-20-CDL-M or equivalent in wipro, Bajaj, Philips.
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than1.5 Mtr below the ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5) will be measured separately under respective item.
M&L Rigid non-metallic PVC conduit 25mm dia in concealed surface including of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessoriessuch as couplers, locknuts, saddles, pipe hooks etc complete all as specified and as directed by Engineer in Charge
Excavation in trenches in hard/dense soil not exceeding 1.5 meters wide and not exc. 1.5 meters deep and getting out excavated soil/bricks/sand complete for poles stays, cables etc complete all as specified and as directed by Engineer in Charge
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and as directed by Engineer in Charge
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick. complete all as specified and as directed by Engineer in Charge
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches complete all as specified and as directed by Engineer in Charge. (Note :- Punning thickness shall be measured.)
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as specified and as directed by Engineer in Charge
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes complete all as specified and as directed by Engineer in Charge:- (a) 150 Sqmm X 3.5 core
(b) 35 Sqmm X 3.5 core
(c) 10 Sqmm X 2 core
Supply & fix 12 way VTPN Distribution Board (with provision for MCCB as incomer & WiNtrip MCB as outgoing) Make:C&S CSDBMCCB100DD12IP43 or equivalent complete all as specified and as directed by Engineer in Charge make in Indoasian/havells/L&T.
S&F MCCB 415 volts 160 Amps 04 pole 36 KA (ICU= 50% ICS) with GI hardwaer complete all as specified and as directed by Engineer in Charge.
Supply and install commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars 400 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 3.15 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings :- (a) Incoming: MCCB TPN- 200 Amps 36 KA - 01 No. (b) Outgoing: MCCB TPN- 100 Amps 16 KA - 04 No. (c) Bus bar Al TPN 400 Amps - 01 Set. Note: space of out going MCCB 1 Nos to be provide and panel mounted on 2' height pcc platform
Supply, install, commissioning and testing factory made (including CPRI type test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars 400 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. Incoming (a) MCCB TPN 250 Amps 36 KA - 01 No. (b) Bus bar Al TPN 400 Amps - 01 Set. Out going- (a) MCCB TPN 160 Amps 36 KA - 01 No. (b) MCCB TPN 63 Amp 16 KA - 4 Nos Note: Space of out going MCCB 1 Nos to be provide and panel mounted on 2' height pcc platform
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.5 Mtr below the ground level connected to GI earth strip of 32 mm x 6 mm size by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5) will be measured separately under respective item.( For Panels)
S&L pipe galvanised medium class complete including fittings 40mm dia complete all as specified and as directed by Engineer in Charge
S&L pipe galvanised medium class complete including fittings 100mm dia complete all as specified and as directed by Engineer in Charge
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe up to 100mm dia complete all as specified and as directed by Engineer in Charge Note :- GI pipe shall be measured and paid in concern Item
S&F ceiling fan (white) of 1200 mm sweep copper wound with super energy efficient BLDC motor including remote, connecting wire PVC insulated twistwd flexible 0.5sqmm copper conductore canopy set, down rod, shackle kit, including all standard accessories complete all as specified and as directed by Engineer in Charge Make: havells Model; Efficiencia Neo/ Crompton Energion HS-48 or equivalent in Bajaj/ Panasonic/Orient.
Supply and fixing of Electric storage water heater of 25 liter capacity, minimum 4 star horizontal/vertical mounting on wall, Cold rolled steel tank body, IPX4 splash-proof technology with Safety Valve,Cord Length: 1 m,Automatic thermostat for safe power cut-off , Thick Polyurethane Foam (PUF) insulation for reduced heat lossincluding wall mounting accessories heating element 2000W, 230 V complete all as specified and as directed by Engineer in Charge Make: Havells Monza Slim Product code :CHWBMDSWH025 or equivant in Bajaj
Supply and fixing of Electric storage water heater of 50 liter capacity,minimum 4 star horizontal/vertical mounting on wall, Cold rolled steel tank body, IPX4 splash-proof technology with Safety Valve,Cord Length: 1 m,Automatic thermostat for safe power cut-off , Thick Polyurethane Foam (PUF) insulation for reduced heat lossincluding wall mounting accessories heating element 2000W, 230 V complete Make: Havells Monza EC-H Product code: GHWVMESWH050 or equivant in Bajaj/Indoasian.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with fixing accessories including making hole in wall complete all as specified and as directed by Engineer in Charge Make: Havells Model: Ventil Air - DB or equivalent makes in CG/Khaitan with and including suitable size louvers complete all as specified and as directed.
Supply & fix heavy duty exhaust fans AC single phase 230/ 240 V of size 380 mm sweep, 1400 rpm with and including suitable size louvers and fixing accessories including making hole in wall complete all as specified and as directed by Engineer in Charge Make: Havells Model: Turbo Force SP or equivalent makes in CG/Khaitan
M&L for PCC (1:3:6) type C2 using 40mm grade stone aggregate in base & foundation of pole including necessary form work complete all as specified and as directed by Engineer in Charge
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and as directed by Engineer in Charge
Supplying, Errecting and fixing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) and providing 5 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide, complete all as specified and as directed by Engineer in Charge
S&F of LED flood light fitting 120Watt pressure die cast housing with IP66 protection ,Efficient high output emitter LED for better distribution and applicable for area lighting.Make : Crompton Cat Part No LFLN-120-CDL/60-M or equivalent model of Philips/Bajaj/Havells
Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal and one MCB SP 20 A complete all as specified and as directed by Engineer in Charge Make Hansel Cat part No:KF 2525 G or equivalent make in /Neptune/Legrand
Supply and fixing of hexagonal frame made out of ms Angle 50 x6mm including nut bolt and washer complete for fixing of flood lights on pole top complete all as specified and as directed by Engineer in Charge
Supply and install split Air conditioning unit (White), inverter type with split units indoor/outdoor with insulated copper tubing, Copper condenser coil, precision cooling technology,dual rotor inverter technology, R32 refrigerant, Brushless DC motor, 4-in-1 Convertible Cooling, Magic Display ecofriendly refrigerent, copper bound rotary compressor complete with cordless remote control unit, Stand for outdoor unit and dust filter for batter indoor air quality 5 star rating and of capacity 1.5 TR. Make LG Model LS-Q18MNZA Inverter Split AC/ Make BLUESTAR Model IC518DATU Inverter Split AC / Carrier 18k 5 Star Ester Neo Hybridjet Inverter R32 I015
Supply and fixing voltage stabilizer suitable for split type AC, 1.5 Ton capacity, Rated Amps-12 Amps, voltage variation range between 130Volt to 280 volts,IC controlled electronic circuit ensuring positive switching of Relay contact making it more reliable & durable,Installed with unique designed vacuum impregnated transformer ensures less heating, high efficiency & low power consumption, Elegantly designed Spray/Powder coated metallic chassis,Smart Time Delay. Rigorously tested as per BIS specificatio Make Blue Bird Model BM 513C /V-Guard Model VWI-400 /Microtek EM 4130+
M&L for wiring for circuit/submain wiring alongwith earth wire of size 2x4.0 sq. mm + 1x4.0 sq. mm earth wire of FR PVC insulated copper conductor, single core cable in concealed rigid PVC conduit pipe size not less then 20mm dia complete all as specified and as directed by Engineer in Charge
Sethi Brothers
PD GUPTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .