Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.0 LAdmitted-Finance | -26.70% | ₹10.0 L | L1 | Admitted-Finance |
| 2 | L2₹10.1 LAdmitted-Finance | -25.80% | ₹10.1 L | L2 | Admitted-Finance |
| 3 | L3₹13.1 LAdmitted-Finance 1ST FLOOR SHOP NO 11 MORI GATE RAJINDER MARKET NEW DELHI DELHI 110006 INDIA | NORTH | DELHI | 110006 | -4.05% | ₹13.1 L | L3 | Admitted-Finance |
| 4 | L4₹13.2 LAdmitted-Finance C 36 DUGGAL COLONY KHANPUR DEVLI ROAD DELHI 110062 | SOUTH | DELHI | 110062 | -3.68% | ₹13.2 L | L4 | Admitted-Finance |
Tender Value
₹13.7 L
EMD Value
₹27,330
Closing Date
2 Mar 2026, 3:30 pmClosed
Executive Engineer (E) BM-II
BM-II (E) Division, Palika Health Complex, Dharam Marg, NDMC, New Delhi - 110011
Upgradation of Electrical fittings, ceiling fans and other allied accessories at Palika Health Complex, Dharam Marg, NDMC
2026_NDMC_287338_1
114/EE(E)BM-II/2025-26
Open Tender
Electrical Works
45 days
Palika Health Complex, Dharam Marg, NDMC
As per NIT
2 documents required · 2 mandatory
₹0
₹27,330
25 Mar 2026
19 Feb 2026
2 Mar 2026
19 Feb 2026
2 Mar 2026
19 Feb 2026
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) Make Crompton, Usha, Havells, Orient with 02 years warranty
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying, Installation, Testing & Commissioning of Surface/Recessed Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm). Fixing of the fitting with the use of light-grade galvanized iron (GI) chains diagonally at two opposite ends of the luminaire and securely anchored to the structure/ceiling above the false ceiling for a secondary safety measure as required. Make: Philips/ crompton/ Havells with 02 year warranty. 36 Watt
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 18-22 Watt (Make: Crompton, Havells, Phillips) with 02 years warrantee
Supply, installation, testing, and commissioning of a heavy-duty exhaust fan suitable for continuous ventilation(size as mentioned below). The fan shall operate on 230V AC, 50 Hz, equipped with a copper-wound motor having thermal overload protection and sealed ball bearings for long life. The fan shall deliver a minimum air delivery of 900–1350 m³/hr with low noise operation. The body and front guard shall be made of powder-coated metal or high-strength ABS polymer depending on the model, with three aerodynamically balanced blades ensuring smooth, vibration-free running. The exhaust fan shall also include a factory-fitted louvers/shutter mechanism for preventing reverse airflow, insects, and dust ingress. Installation includes fixing of fan frame using anchor fasteners, providing necessary supports, and sealing gaps around the fan with cement mortar/PU sealant for dust-free installation. The fan shall be of approved make such as Crompton / Havells / Usha / Orient / Bajaj or equivalent, complete with all accessories with 02 years warranty. (a) 300 mm (12 inch)
(b) 380 mm (15 inch)
Supply, installation, testing, and commissioning of a high-speed wall-mounted fan of size 400 mm (16 inch) sweep, suitable for continuous indoor use in offices, rooms, corridors, and service areas. The fan shall operate on 230V AC, 50 Hz, with a copper-wound motor, thermal overload protection, and a minimum speed of 1300–1400 RPM delivering air delivery ≥70–75 m³/min. The fan body shall be made of powder-coated metal or high-strength ABS polymer with corrosion-resistant guard, three aerodynamically designed blades, and a sturdy mounting bracket with locking mechanism. The fan shall include 3-speed control through pull-cord or regulator, smooth oscillation mechanism with angle adjustment, and vibration-free operation. Installation includes drilling, fixing anchor fasteners, mounting bracket fixing, ensuring firm installation. Fan must conform to IS standards for safety and performance, and shall be of approved make such as Usha / Havells / Crompton / Bajaj / Orient.
Supply, installation, testing, and commissioning of suitable-size PVC louvers for existing exhaust fans installed in Panchkarma rooms, toilets etc. The louvers shall be of the same sweep size as the existing exhaust fan (typically 300 mm / 380 mm), designed to provide automatic back-draft prevention, restricting entry of dust, insects, rainwater, and reverse airflow. The louvers must be factory-assembled with gravity-return flaps or spring-loaded shutters, made of UV-resistant, non-corrosive material ensuring long life in humid and high-usage spaces. The job includes cleaning the mounting surface, and fixing the new louver assembly using stainless-steel screws, PVC rawl plugs, and proper sealing around the frame to ensure airtight and vibration-free installation. The louvers shall allow smooth air discharge without obstructing airflow and must be compatible with the existing exhaust fan’s frame and mounting holes. All work shall be completed using proper tools, alignment checks, and finishing so the fan operates without noise, friction, or obstruction. Louvers shall be from approved makes such as Usha / Havells / Crompton / Bajaj / Orient.
Deduct - Less credit as per credit sheet
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.10 MB
BOQ_380696.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid