| 1.00Dismantling of old VRF and supply and installation of VRF outdoor units of the following capacities. The scope includes required supports with necessary bolts, screw & nuts etc,complete. The capacity of the units shall be the nearest rating based on manufacturer.Make: O-General/Equ | |||||
| 1.01 | 22HP | 1 | No's | 4,82,850 ₹4.8 L | 4,83,000 ₹4.8 L |
| 2.00Dismantling of old VRF and supply and installation of VRF outdoor units of the following capacities. The scope includes required supports with necessary bolts, screw & nuts etc,complete. The capacity of the units shall be the nearest rating based on manufacturer.Make: O-General/equ | |||||
| 2.01 | 12HP | 1 | No | 2,98,080 ₹3.0 L | 3,00,000 ₹3 L |
| 3.00Renewal by Supply and installation of VRF Ducted indoor units of the following actual capacities. The scope includes necessary bolts, Remote, signal Receiver, panel, screws & nuts etc, the capacity of the units shall be the nearest rating based on manufacturer. | |||||
| 3.01 | 3.0 TR Ducted | 12 | No's | 1,02,500 ₹12.3 L | 1,03,000 ₹12.4 L |
| 4.00 | Renewal by Supply and installation of Hard drawn 18G copper refrigerant pipes with necessary fittings, extension kit and associated accessories. Refrigerant pipes shall be clamped to the tray horizontal supports with necessary protection against mechanical friction with tray supports and shall be clamped firmly with heat resistant grommets. Copper refrigerant pipes shall be insulated with 19.10mm thick closed cell elastomeric tubular insulation materials (Suction + Discharge) | 252 | Rm | 1,190 ₹3.0 L | 1,200 ₹3.0 L |
| 5.00 | Renewal by Supply and installation of MS stand for ODU | 2 | No's | 5,607 ₹11,214 | 5,700 ₹11,400 |
| 6.00 | Renewal by Supply and installation of Refnets for the above units | 20 | No's | 9,590 ₹1.9 L | 9,600 ₹1.9 L |
| 7.00 | Refilling of Refrigerant gas R-410A top-up charges | 140 | Kg | 549 ₹76,860 | 600 ₹84,000 |
Tender Value
₹49.3 L
EMD Value
₹34,700
Closing Date
18 Feb 2026, 3:00 pmClosed
Superintending Engineer PWD
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle 2, Chepauk Chennai 5
Renewal of VRF Air conditioning system for East Wing Back side Ground, 1st 2nd Floor with AMC from the year 2026 to 2032 in New State Guest House, Chepauk, Chennai-5.
2026_PWD_659044_1
TNPWD/54-2 BCM/2025-26
Open Tender
Electrical Works
Chepauk
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹34,700
20 May 2026
16 Feb 2026
18 Feb 2026
16 Feb 2026
18 Feb 2026
16 Feb 2026
Dismantling of old VRF and supply and installation of VRF outdoor units of the following capacities. The scope includes required supports with necessary bolts, screw & nuts etc,complete. The capacity of the units shall be the nearest rating based on manufacturer.Make: O-General/Equ
Dismantling of old VRF and supply and installation of VRF outdoor units of the following capacities. The scope includes required supports with necessary bolts, screw & nuts etc,complete. The capacity of the units shall be the nearest rating based on manufacturer.Make: O-General/equ
Renewal by Supply and installation of VRF Ducted indoor units of the following actual capacities. The scope includes necessary bolts, Remote, signal Receiver, panel, screws & nuts etc, the capacity of the units shall be the nearest rating based on manufacturer.
3.0 TR Ducted
Renewal by Supply and installation of Hard drawn 18G copper refrigerant pipes with necessary fittings, extension kit and associated accessories. Refrigerant pipes shall be clamped to the tray horizontal supports with necessary protection against mechanical friction with tray supports and shall be clamped firmly with heat resistant grommets. Copper refrigerant pipes shall be insulated with 19.10mm thick closed cell elastomeric tubular insulation materials (Suction + Discharge)
Renewal by Supply and installation of MS stand for ODU
Renewal by Supply and installation of Refnets for the above units
Refilling of Refrigerant gas R-410A top-up charges
Renewal by Supply and installation of PVC drain pipe insulated with 6mm nitrile rubber insulation.
Renewal by Suplly and Run of Copper Armoured Cable 4c x 10sqmm- Copper Armoured Cable
Renewal by Supply and Fixing of heavyduct 50mm thick anti vibration rubber pads to with stand outdoor load.
Renewal by Supply and fixing of flexible canvas connection between indoor unit and ducting.
Renewal by Supply and Run of 3C X 1.5sqmm - Flexible copper cable with 1 inch white Flexit.
Renewal by Supply and Run of 2C X 1.0sqmm - Shielded cable with 1 inch conduit.
Renewal by Supply , Fabrication and erection of fabricated plenum ducting made up of GI sheets of complete with MS angle supports angle flanges, anchor fastess,tees and bends whereever necessary etc as required.
Renewal by Supply and providing thermal insulation of 9mm thick vidoflex with aluminum foil.
Renewal by Supply and Fixing of Outdoor Frame work.
Renewal by Supply and fixing of Filter (Med. Static Ductable) Duct Coller.
Dismantling of ODU and shifting including crane charges
Pressure testing, vaccumising & Commissioning charges
Labour charges for cutting round Holes of 3inch x 3inch and respectively to run the copper pipe and drain pipe for all 12 Rooms
Supply and fixing of 150mm x 105mm casing pipe for copper pipe work fixing on wall for all 12 Rooms. SR
Lifting, shifting & scoffolding charges for AC indoor & outdoor units.
Renewal by Supply and fixing of extruded aluminum powder coated supply and return air grilles/diffusers with volume control damper.
Replacement of Trap Door with necessary false celiling for indoor units.
Comprehensive servicing and maintenance of VRF for 5 Years (2027-2032)
GST at 18%
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
Condition.pdf
Tender Documents • 0.27 MB
BOQ_790677.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid