Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹6.3 L+₹59,820 (10.5%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹6.5 L+₹79,290 (13.9%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
9 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Fatehgarh
AGE (I) Fatehgarh
REPAIR AND MAINT OF WINTER APPLIANCES AND SOME OTHER CERTAIN MISC E/M WORK AT FATEHGARH CANTT
2024_MES_669844_1
AGE(I)/FAT/ET-25 OF 2024-2025
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹20,000
Yes
21 Nov 2024
7 Sept 2024
15 Oct 2024
7 Sept 2024
9 Oct 2024
24 Sept 2024
7 Sept 2024 - 23 Sept 2024
Amount
Taking down carefully storage type water heater (Geysers) of any make of 50 litrs capacity at any height opening for inspection complete including heating element inner copper tank etc de-scaling cleaning and re-assembling of Geysers after necessary repairs carrying out and re-fixing in same position (spares parts as required for repair/replacement geyser are measured and paid separately) including making good to walls with CM (1:3) or PCC (1:2:4) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc all as specified & directed.
dittto as above but for Geysers of capacity 25 ltrs .
S&F of 1.5 KW Heating Element, Push/ Screw type with ‘O’ ring complete all as directed.
S&F of 2.0 KW Heating Element, Push/ Screw type with ‘O’ ring complete all as directed.
S&F of 2.0 KW Heating Element, Push/ Screw type with ‘O’ ring with and including aparatus plate assembly suitable for Recold Make geyser as per sample complete all as directed.
S&F of Geyser assembly suitable for 25 ltr capacity ISI marked including dismantling of old unserviceable geyser assembly complete all as specified & directed.
S&F of Geyser assembly suitable for 50 ltr capacity ISI marked including dismantling of old unserviceable geyser assembly complete all as specified & directed.
S&F of thermostate suitable for 50 Ltr Geyser ISI marked complete all as specified & directed.
S&F of thermostate suitable for 25 Ltr Geyser ISI marked complete all as specified & directed.
S&F of inner tank made of steel suitable for 25 Ltr geyser including dismantling of old unserviceable inner tank complete all as specified & directed.
S&F of outer tank made of steel suitable for 25 Ltr geyser including dismantling of old unserviceable inner tank complete all as specified & directed.
S&F of bottom cover suitable for 25 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
S&F of LED indicating lamp 230 volts 50 HZ AC suitable for geyser any type (round,squire or rectangular type) any capacity complete all as specified & directed.
S&F in repair of metal clad plug & socket DB with plug top including one MCB single pole 20 Amps 240 volts 50 HZ complete all as specified & directed.
S&F in repair of PVC connection heavy duty 15mm dia 45 cm long with PTMT nuts complete all as specified & directed.
S&F of pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
M&L for sub main wiring with two single core 6 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade in existing PVC conduit concealed in wall for sub main connection including 6 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly including dismantling and resurfacing the disturbed surface all as specified & directed. (Note :- Two runs of 6 sqmm (FRLS) and one run of 6 sqmm (FRLS) copper conductor shall be measured as one unit length.)
Supply and fixing in repair of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with alum thimbles as required complete incl resurfacing the disturbed surface all as specified & directed.
S&F in repair of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection by appropriate size of alum lugs complete all as specified and directed
S&F of MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F of MCB SP 10 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F in repair of MCB SP 10 to 40 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F in repair of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Dismantling complete solar water heating system of capacity 300 LPD per day including hot & cold water pipes and hot water tank complete. Repairing the system fixing back in position and testing complete all as specified and as directed. Note:- Rates quoted by the contractor shall deemed to be included for:- (a) Making good the worn out missing nuts bolts, washers, union sockets, flanges and screws etc. (b) Dismantling the solar panel descaling of hot water pipes by using appropriate chemicals, cleaning and washing all copper tube throughly cleaning the complete panel, making the tubes scale free, and re-assembling the panel. (c) Cleaning hot and cold water tanks. (d) All other materials shall be measured and paid separately under respective items.
dittto as above but for capacity 200 LPD….. dittto as above ….
S&F in repair of steel water tubing 15/20 mm bore medium grade galvanised with all fittings for transportation of hot water from hot water tank to supply point duly insulated and insulation secured with tape and covered with aluminum sheet 1 mm thick all as recommended by the manufacturer complete all as specified and directed.
Supply and fixing in repair of Angle stop valves of any colour high pressure screwed for iron pipe and fixed for 15-20 mm bore pipes.
S&F in repair of plug top 15/16 Amp complete all as specified and directed.
M/S CHAUHAN ELECTRIC WORKS (BID ID -3133277)
M/S Arvind Electricals (BID ID -3120253)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .