Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance TEHSIL TRINTHA DISTRICT REASI 182311 JAMMU AND KASHMIR | REASI | JAMMU AND KASHMIR | 182311 | Admitted-Finance |
| 4 | Admitted-Finance UDHAMPUR | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹83,100
Closing Date
14 Jul 2023, 4:00 pmClosed
Executive Engineer Electric Division UdhampurJPDCL
Executive Engineer Electric Division UdhampurJPDCL
for Creation of 2 No. Electric Sub Stations of 250 KVA each including Erection of HT.LT lines under WSS Kud NABARD
2023_PDD_220172_1
ED/Udh/23 of 2023-24 dt. 07-07-2023
Open Tender
Electrical Works
Turn-key
45 days
In District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division UdhampurJPDCL
₹83,100
2 Aug 2023
7 Jul 2023
15 Jul 2023
7 Jul 2023
14 Jul 2023
7 Jul 2023
7 Jul 2023 - 10 Jul 2023
Survey, Supply, Transportation, Carriage, erection,Testing and Commissioning for erection of 11 KV line on 9 mtr long ST poles, 30 mm sq. ACSR condcutor at Pyt. Ghar Kud under WSS Kud (NABARD) for creation of 250 KVA Sub Station.
9 mtr. Long ST Poles (ST 410 SP33)
GI V-Cross arm with Top Bracket including clamp.
GI Channel X-arm including clamps and Braces.
30 mm sq. ACSR Weasel Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger plates with clamps
Anti Climbing device with clamps
Earthing complete by GI pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI strip.25x3 mm
Painting of 9 mtr long ST poles with two coats of aluminium paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Installation of 250 KVA substation at Pyt. Ghar Kud under WSS Kud (NABARD).
11/0.433kV, 3-phase Distribution Transformers 250 KVA with Bimetallic Terminal Connectors Energy Level-2, Copper wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
11 kV Horn Gap Fuse Set 3 Phase 200A
400 mm² (2ckt.) 1.1 kv Grade, PVC insulated ,Al. stranded conductor FRLS type
9 Mtr. Long ST Pole( ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting.
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber
11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
LT Distribution Box for 250 KVA DTR with MCCB for incomer and SFU's for outgoing Circuits.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger plates with clamps
GI Barbed wire for Anti Climbing
3 phase HT trivector meter with CT/PT unit
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
Painting of 9 mtr long ST poles with one coat of Red oxide and two coats of aluminium paint
Survey, Supply, Transportation, Carriage, ,Erection,Testing and Commissioning for erection of LT line on AB Cable 120 mm sq. AB (LT) Cable (3X120+1X16+1X70mm sq.) XLPE (1.1KV, 3+1C,AL) at Pyt. Ghar Kud under WSS Kud (NABARD) for creation of 250 KVA Sub Station.
8 mtr. Long ST Poles (ST 410 SP15)
120 mm sq. AB (LT) Cable (3X120+1X16+1X70mm sq.) XLPE (1.1KV, 3+1C,AL)
Suspension/Tension Clamp with eye hook.
Galvanized Nuts and Bolts
Danger plates with clamps
Anti Climbing device with clamps
Earthing complete by GI Rod 20 mm 2.5 mtr long through GI strip.25x3 mm
Painting of 8 mtr long ST poles with two coats of aluminium paint
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
Insulating Piercing connectors
PG Clamps
Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 nos), anchor plate (200*6mm), nuts-bolts, 2 Nos turn buckets, 1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete.
Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for erection of 11 KV line on 9 mtr long ST poles, 30 mm sq. ACSR condcutor at Mandlote Upper Kud under WSS Kud (NABARD) for creation of 250 KVA Sub Station.
9 mtr. Long ST Poles (ST 410 SP33)
GI V-Cross arm with Top Bracket including clamp.
GI Channel X-arm including clamps and Braces.
30 mm sq. ACSR Weasel Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger plates with clamps
Anti Climbing device with clamps
Earthing complete by GI Rod 20 mm 2.5 mtr long through GI strip.25x3 mm
Painting of 9 mtr long ST poles with two coats of aluminium paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Installation of 250 KVA substation at Mandlote Upper Kud under WSS Kud (NABARD).
11/0.433kV, 3-phase Distribution Transformers 250 KVA with Bimetallic Terminal Connectors Energy Level-2, Copper wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
11 kV Horn Gap Fuse Set 3 Phase 200A
400 mm² (2ckt.) 1.1 kv Grade, PVC insulated , Al.stranded conductor FRLS type
9 Mtr. Long ST Pole ( ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting.
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber
11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
LT Distribution Box for 250 KVA DTR with MCCB for incomer and SFU's for outgoing Circuits.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger plates with clamps
GI Barbed wire for Anti Climbing
3 phase HT trivector meter with CT/PT unit
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
Painting of 9 mtr long ST poles with one coat of Red oxide and two coats of aluminium paint
Survey, Supply, Transportation, Carriage, Erection ,Testing and Commissioning for erection of LT line three phase four wire on 8 mtr long ST poles, 50 mm sq. Rabbit condcutor at Mandlote Upper Kud under WSS Kud (NABARD) for creation of 250 KVA Sub Station.
8 mtr. Long ST Poles (ST 410 SP15)
GI M-Clamps for shackle insulator
50 mm sq. Rabbit Conductor
Shackle Insulators
Galvanized Nuts and Bolts
Danger plates with clamps
Anti Climbing device with clamps
Earthing complete by GI Rod 20 mm 2.5 mtr long through GI strip. 25x3 mm
Painting of 8 mtr long ST poles with two coats of aluminium paint
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 nos), anchor plate (200*6mm), nuts-bolts, 2 Nos turn buckets, 1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete.
supply only heat shrinkable Straight Through Cable Jointing Kit for 120mm² LT AB Cable
M/S JCM CONSTRUCTIONS
M/S VAISHNO TRADERS
VEENA CONSTRUCTION CO.
M/S SURAJ PARTAP SINGH
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .