| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.4 L+₹5.0 L (11.2%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
IMPROVEMENT TO GROUND RUN POINT NO 2 AND ASSOCIATED AREA AT AIR FORCE STATION OJHAR
2022_MES_510290_1
8852/E8
Open Tender
Civil Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹96,000
Yes
31 Mar 2022
24 Feb 2022
24 Mar 2022
25 Feb 2022
22 Mar 2022
10 Mar 2022
60 days
Amount
Dismanteling of Steel and Iron of any description MS plate including Epoxy coating complete and to be cut in required shapes through cutter and removing from site to MES store yard to deposit n exc 3 KM. The necessary arrangements are to be done by Contractor without any extra cost. Rates are deemed in quoted item.
Demolition of Cement concrete of any description i.e Lean concrete, Pavement concrete etc in ground floors and pavings complete all as specified and as directed by Engineer-In-Charge. Note : During demolition of PQC the contractor will baricade the site with temporary steel post and sheeting for ensure dust free site upto laying of PQC and No extra cost should be made for that.)
Excavating over areas n exc 1.5 m deep and getting out out in hard/hense soil (including WMM & GSB etc)
Removing the demolition materials retrieved from above item No 2 & 3 beyond defence land on daily basis and depositing own arrangement of contractor complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick with soils.Complete all as specified and directed by Engineer-in-charge.
Rolling and consolidating formation surface in cutting with 8 to 12 tonne power roller including filling in depression which occurs during the process of rolling, rolling to required gradient and camber complete.
M&L 200mm thick compected thickness in two layers (each layer of compacted thickness 100mm) Granular Sub Base , over compected sub grade ,graval crushed stone & natural sand all as per grading V, spread, rolled and consolidated to gradient and camber required.
M&L 150mm thick (each layer of compacted thickness 75mm) WMM in two layers compected separately, with coarse aggregates of grading as per MORT&H 5th revision table 400-13 of Granite trap or basalt stone, spread, rolled and consolidated to gradient and camber required.
Providing and laying Dry Lean Concrete (DLC) of thickness 150mm having minimum 7 days compressive strength of 7N/mm2 over a prepared sub grade with coarse and fine aggregate confirming to IS : 383, size of aggrgate n exc 40mm (grading and other parameters as per table 600-1 of MORTH, IRC SP : 49 specification) of design mix , minimum cement content should be 150 kg/cum as per IS 456 mixed in batching plant, transported to site, including spreading and compected by using 8 to 10 tonnes roller with necessary formwork finishing etc all as specified and directed.,
Supply only 10mm thick Fine aggregate (sand) cushion over DLC for laying of polythene film.
M & L for polythene film ,black 400 micron thick laid in floors . complete all as specified and as directed by Engineer-In-Charge.
M & L RMC in pavement Quality Concrete (PQC) (Thickness of concrete shall be 250mm of minimum field flexural strength strength 45kg/Sq cm (lower control limit- LCL) after 28 days in pavement slab using min 400 Kg of cement per cum and using non circular fibre synthetic reinforcement @ 0.25% by wt of cement /Cum of concrete with crushed stone aggrgate of grading as specified laid in panels, spread and compected , surface vibrators, vibrating screed and needle vibtator & curing , belting & finishing top concrete pavement etc compected shall be ensured as per IRC 43-2015. Flexural strength shall be estblished by beam test and job mix formula should be compatible to lab mix design as per IS 383-2386, 10262, IRC-44, 456, 516, 1192 and 8112 complete all as specified and directed.
Forming 25mm thick expension joint for full depth of PQC using diamond cutter and filled with 30mm thick pre moulded compressible filler polyethelene closed cell type board as specified, and applying closed cell, medium density, cross linked polyethylene foam back up rod over filler board, priming top 12mm with approved primer and filling with polyurethene based sealent. High Density filler board HD 100 joint sealent of life 10 yrs and MAF as +/- 30% applying masking tape on edges of joint to prevent accidential spillage of sealent and removing the masking tape after filling of sealent all as per the directions of the manufacturer complete all as specified and as directed.
Forming construction joint 25mm deep x 10mm wide using diamond cutter and filled with closed cell type board as specified and applying closed cell, medium density, cross linked polyethylene foam back up rod of 12mm dia ,joint sealent, and MAF as +/- 30% to be added for complete width of the joint. Priming top 10mm with specified primer and filling with polyutherene based sealent, applying masking tape on edges of joint to prevent accidential spillage of sealent and removing the masking tape after filling of sealent all as per the directions of the manufacturere complete all as specified and as directed.
Forming dummy Construction joint using diamond cutter with initial saw cut with 3mm blade soon after conctere sets for one third depth of PQC. Widenining the first saw cut to 8mm wide and 22 mm deep from top priming top 10mm with approved primer, Joint sealent and MAF as +/- 30% and applying masking tape on edge of joint to prenvent accidential spillage of sealent and filling with polyutherene based sealent to closed cell, medium density, cross linked polyutherene foam back up rod of 10mm dia for complete width of the joint, and removing the masking tape after filling of sealent all as per the directions of the manufacturere complete all as specified and as directed.
M&L Polyurethene flooring on concrete surface with the follows specifications. (a) The substrata concrete must be prepared by dust free pre treatment e.g vaccume cleaning. (b) Laying of 1st Coat of Primer of MASTER PRIME-52, 0.4 to 0.7mm thick, coverage 6 sqm/1 Kg of M/s CHOUKSEY or equivelant M/s CIPYPolturethene Ltd with consisting of two component solvented epoxy resin based primer suitable for priming concrete surface before laying of the primer the surface drying & loose perticles. (c) M&L Application of body coat 4.5mm thick of MASTERFLOOR - PU 1000 of M/s CHOUKSEY or equivelant M/s CIPYPolturethene Ltd . MASTERFLOOR - PU1000 consists of part A+B+C Part 'A' - Polyol M/s CHOUKSEY or equivelant M/s CIPYPolturethene Ltd . Part 'B' - isocyanate M/s CHOUKSEY or equivelant M/s CIPYPolturethene Ltd . Part 'C' - Aggregate and active fillers M/s CHOUKSEY or equivelant M/s CIPYPolturethene Ltd . The consumption of 3 parts will be 1.90 Kg per Sqm/1mm thickness layer in the ratio of A:B:C = 2.60 : 3.40 : 14.00 by wt of mixing. (d) Top coat of MASTERCOAT- PU 131, 0.60mm thick of M/s CHOUKSEY or equivelant M/s CIPYPolturethene Ltd .with glossy finish with covering capacity of 8-10 Sqm per 1 Ltr. (e) The flooring shall be provided for Ground Run Point for heavy vibrations contractor has to adhere to every instructions strictly/specifiaction all as per given above and directed. (f) The Contractor shall be responsible for any damage/ deteriotion occured during the two year after the completion of work & Contractor will make good or replace the flooring without any extra cost to Deptt.
Taking down carefully existing bitumen tarfelt including plastering upto 15mm thick cleaning the surface and make free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and removing all foreign materials / Bitumenous primer completely , cleaning and washing the existing surface of roof/slab, terraces including flashings and junctions of parapets/Curb walls etc and as directed by Engineer-in-charge. Note : (i) If taking down of plaster is exceeding 15mm than PCC and plaster both shall be measured under ser item No 20 below (ii) Removing of the rubbish to a distance outside MoD land at own arrangement of Contractor.
Demolition cement concrete of any description and in any position not otherwise specifically provided for roof pedding and removing the demolished material outside MoD land at own arrangments of Contractor.
M&L for providing ement concrete 1:2:4 Type B0 (Using 12.5mm graded stone aggregate) as in bed plate/roof kerb/PCC padding and haunching etec all as specified and directed by Engr in Charge Note : PCC shall be laid in slope and thickness shall be averege(minimum average thickness 25 or as oer site requirement for maintaing the slope) as per site including filling in depression by providing concrete bench marks for maintaining th perfect slope to drain out the rain water as directed by Engr-in-Charge. No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof by Manually/ mechanically to acheive the proper strength nand workmen ship.
M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces mixed with water proofing compound @ 0.12 ltr per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement Complete all as specified and directed by Engineer-in-charge.. Note:- (Cost of water proofing compound shall be included in this item quoted by the Contractor).
M&L providing cement slurry @ 3Kg per sqm on existing roof surface before laying PCC/ Plaster.
M&L for cleaning the newly plastered surfaces throughly with wire brushes and providing water proofing treatment all as given here in after (a) Bituminous primer @ 0.3lit per Sqm conforming to IS-3384-1986 (b) 3 mm thick APP polymer modified moply FP of M/S TEXSA Ltd or M/S STP Ltd or ASIAN PAINTS of Hydrostop Tiki Dan of M/s Tikki tar Ltd with minimum wt 3.0 Kg per square metre membrane (one layer) laid by torch application method. (c ) Applying two coat of bituminous based aluminium paint @ 0.20 Kg in two coats (total in two coats) per square metre over membrane. Complete all as specified and directed by Engineer-in-charge. (d) The overlaps of APP shall be SSR part 1 and APP shall be laid by expert/ skilled workers only, bitumen based aluminious paint applied by brushes only.
Demolition of cement concrete (unreinforced) in ground floors, pavings and walls of any description (below or above ground level).Complete all as specified and directed by Engineer-in-charge.
M & L for cement concrete type B-1 (1:2:4) usng 20 mm graded broken stone aggregate 40 mm thick as sub base . complete all as specified and as directed by Engineer-In-Charge.
M & L for vetrified ceramic tiles 10 mm thick dark shade/Double charged/ ultra charged square of size 600 x 600 in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and Including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-charge.
All as per item No 25 but in Vertical surfaces size n exc 0.36 sqm such as dado/skirting including 10 mm thick rendering of cement mortar 1:4
S&F Horizental level suspended Ceiling comprising of Armstrong GI Clip-in Micro perforated 600x600mm (nominal size) tiles of 120mm galvanised steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white colour with concealed suspension syayetm having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on other side. Tile shall have perforated of hole diameter 2.5mm and open area 16% with linear and diagonal pitch of 5.5mm and 7.7mm respectively along with a border of 10mm. The tile shall be electrostaticalkly polyster powder coated using RoHS compliant powder having coating thickness ranging from 60-80microns. Back side of the tile shall have Soundtex fleece hot pressed mechanically for uniform bonding to achieve NRC up to 0.7 all as per manufactures instructions , complete all as specified and as directed by Engineer-In-Charge. Note : If electrical cables are running at site aand required to be relocated electric fittings on walls are required to be shifted including refixing of fan/ light fittings and other light acessarry including making good the wall surface.shall be deemed to be included to the rates.
Dismantling wall/ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
S&F of Armstrong make "OPTRA" acoustical wall panel system along with its impaler accessory panelsize of 25mm thick 600mmx600mm/1200mmx600mm (of any approved standard shade) fixed on a 50mmx50mm second class hardwood timber grid frame of size 500mmx500mm duly filled with 48kg density x 50mm thick plain glasswool of UP Twiga/ Owens corning make all complete.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n.exc. 4 Sqm each compete all as specified as directed by Engineer -in -charge .
M & L for providing two component posyster powder coated alum section in Aluminiium glazed door frame with Double leaf door of size 101 mm x 44mm x 2.00 mm thick fixed with 4 Nos hinges and shutters with top rail, middle rail and bottom rail of size 90 mmx44.4mmx1.6 mm thick and Style 90 mmx44.4mmx1.6 mm thick rails and also including 200 mm long aluminium powder coated handle on both sides of shutters, aluminium tower bolt 150mm long 01 nos per leaf, including tinted glass panel 4.8 mm thick fitted in top panel and 12 mm thick prelaminated particle board in the bottom panel with necessary joining cleats, glazing clips, rubber packing, aluminium beading, screws etc including fixing of hydrolic door closer of Make : Dorma and equivilant complete all as specified by the Engineer-in-Charge.
S&F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides
S & F 100 mm MS butt hinges medium weight cold rolled mild steel compete all as specified as directed by Engineer -in -charge
S & F 150 mm aluminium anodised barrel tower bolts of extruded section, ISI marked compete all as specified as directed by Engineer -in -charge
S & F 150 mm extruded aluminium alloy handles , fabricated type, anodised, ISI marked compete all as specified as directed by Engineer -in -charge
S & F 300 mm long and Mild steel Chromium plated sliding door bolts, plate type, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed compete all as specified as directed by Engineer -in -charge
M & L two coats of synthetic enamel paint over one coat of pink primer on wood or wooden based surface exc. 10cm width or girth including preparation of new or previously untreated surfaces.compete all as specified as directed by Engineer -in -charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates similar work conforming to Fe-290 Gde E-165 Note : Angles made in shape to support the MS Gutter, the Gutter shall be measured and paid in item No 42 here in after.
Dismantling Asbestos cement /FRP sheet/GI sheet(corrugated ted, semi corrugated, etc.) sheets in roof coverings up to height 25M and taking care of earthing strip and refixing all as specified and directed by Engr in Charge
S & F in reapirs 3.15 mm thick Plain, mild steel sheeting, in ridges, hips, valley gutters, drip, funnels make in shape/ design as directed and straight flashings (length and girth as fixed) with grade of Fe 410-W 9gde-E-250) Quality B. Note : (i) Contractor shall made own arrengment for climbing and working on hangers not exceeding 16 mtr ht. (ii) Dismanteling the vally gutter through mechanical cutter ( No welding rod is allowed during cutting/Dismanteling of existing of gutters) on existing place for taking down and follow all safety & fire rules. (iii) The Contractor shall be laible to execute the work in rainy seasonwithout any objection, if any lackage occuried after execution contractor will redo the work immedeatly . All safety measures are followed by the Contractor as per safety guidlines. (iv) 100mm minimum overlap shall be provided at the joints of gutters and welding must be water tight and there shall be no seepage at joints of gutters. only straight length of the gutters shall be measured nothing shall be paid extra for overlaps. (v) Gutter shall be provision betwwen two sloping roof with supprot of angles made in shape. (Angle shall me measured and piad in above item No 40.)
S&F PVC (SWR) pipe 160mm bore of pipe, single socket in any length with rubber ring joint, fixed to walls with clamps complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) 160mm bore shoe bend specified & as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil (Including brickwork and PCC in drain below Ground level)
M & L for cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete including filling around pipes.Complete all as specified and directed by Engineer-in-charge.
M&L Brick work with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1 : 4 including trapozedial shape of brick work as in drain all as specified and directed by Engr-in-Charge
M & L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge
M&L for PCC type B0 in 1:2:4 ( using 12.5mm graded aggregate) as in coping, bed block and surface channel of drain all as specified and directed by Engr in Charge
Extra for forming fair finished drain or channel upto 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc.
S&F Precast cement concrete load class for HCV perforated and single layer of 10 mm dia steel bar 100mm C/C cover dimensions 500x550x75 mm or required size Make : KK, Universal, Hindustan and equivelent all as specified and directed by Engr in Charge.
M & L two coats of synthetic enamel paint on steel surfaces over one coat of red oxide or zinc chrome primer, of any description over 10cm width or girth including preparation of new or previously untreated surfaces of steel. compete all as specified as directed by Engineer -in -charge
S&F anti bird net, Square mesh size 20mm x 20mm Black/ White or any colour HPDE knotted Net, thickness of the net 1.00mm, weatherproof, UV stabilized and chemically inert, Breaking strength of 23.08 kg per yarn, having a melting point of 260 centigrade fixed with boarder rope of dia 4mm @ 1.20mtr C/C bothways, UV stabilized boarder rope joint with the net by machine inter locking process using three twines of the same as that of net tied to 12mm dia hooks (made to shape) or welded to steel structure and 12mm dia ancher fastner bolt fixed to RCC structure as applicable at suitable intervals complete upto ht 16mtr work shall be executed all as specified and directed. Notes: 1. work is to be executed in the technical area where restriction of time may occure as per user requirement. 2. Barricading all around the site with steel props and sheets shall we provided by the contractor of desired height at site to avoid FOD to the Aircraft testing for Ground run point.
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets etc to be measured separately) incl wooden battens and conduct etc& removing material as directed complete all as specified and as directed by Engr-in-Charge.
Taking down existing sub mainAluminium wiring any capacity & size and making good surface, complete all as specified and directed by engineer-in-charge.
Taking down old flood light any type and capacity etc all as directed.
Supply laying & testing cable XLPE insulated, screened, pvc bedded, galvanized steel strip or wire armored, electric power cable(heavy duty)with stranded aluminum conductor,1100 volts grade, of size 4 core 10 sq mm all as specified and directed by engineer-in-charge
M&L wiring for circuit/ sub main wiring of 2x2.5 Sqmm+1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in and including in Steel conduit 20mm dia medium grade complete all as directed by Engr -in- Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
M & L for Point wiring with 1.5 Sqmm (nominal area) PVC( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm medium grade as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note:- Cutting & making good of chasis in the wall/Roof/Floor is deemed to be inclued in the quoted rates.
All as per item No 59 but for One 5 Amps socket point on same board / below board with other switches.
All as per item No 59 but for One 5 Amps switch socket on independent board.
Supply & Fix ceiling rose 3 phase/pvc body Make : Anchor/ Roma/ Legrand, complete all as specified & as directed by Engineer-in-Charge.
Supply & Fix Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/ Roma/ Legrand, complete all as specified & as directed by Engineer-in-Charge.
Supply & fix Modular switch one way 6 Amp,1 Module , Make Anchor/ Legrand/ Crabetree, complete all as specified & as directed by Engineer-in-Charge.
Supply & fix Modular switch one way 16 Amp, 1 Module , Make Anchor/ Legrand/ Crabetree ,complete all as specified & as directed by Engineer-in-Charge.
Supplying and fixing Modular socket, 6/16 amps-2/3 pin combined, 2 Module, complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing in repairs Modular white cover plate with frame, 6 Module, Make Legrand /Anchor Roma/Crabetree.
Supply & fix metal fiush mounting box 6 module.
Supply, Installation, Testing and commissioning of LED High bay 120Watt With a system efficacy of minimum 130 lm/W. The luminaire shall have a rated system lifetime of 50000 burning hours at L70. the luminaries should have a colour temperature of 5700K and CRI>70. The luminaire shall meet IP66 rating with THD < 20% and PF >0.95. The luminaire housing should made of High efficiency round highbay in PDC housing suitable for industrial application. . The total power consumption should not exceed 120W (Including driver) Make: Crompton Cat.Part.No. "LHB11-120- CDL/60-HPM" Or Equivalent Bajaj Cat Pt No BGHBM NXT B156L WH NBSD 120Watt or WIPRO Cat Pt No LH21-192-060-57-XX 120 Watt.
Supply, Installation, Testing and commissioning of integral driver LED flood light 80 Watt made up of pressure dia cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. Option for 3000K. 10 KV SPD included. the total power consumption should not exceed 80 W (including driver) of Make Crompton CAT No - LFL-80- CDL/60-HPM LED , Bajaj cat part No BJFL 80 W LED and Wipro Cat Pt No LF19-931-060-57-XX 80 Watt complete all as specified and directed by Engineer- in-charge.
Supply and fix in repair decorative ultra slim square profile linear Light Linea lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 20W LED 6000K, complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No. LDL-20-WW or equivalent in Bajaj/ HAVELLS.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA C series. Cat part No-408595 Make : Legrand/ L & T./Standard ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB SPN 32 to 40 Amps 240 volts 10 KA. Cat Part No-408617 Make : Legrand /Standard/L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar ,8 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply of LIVA advanced ESE lightning protection system consist of:Radius of protection 40 mtrs with level – complying with NFC 17-102, ESE lightning terminal –Make: LIVA, Model: LAP-CX-040, or equivalent as approved by engr-in charge complete all as specified and as directed . Note :-The installation and testing of lightning protection system shall be carried out strictly by OEM complete .
Supply, of errecting adapter head mast of 5 mtr supporting mast, Adaptor & mast base plate, Complete all as specified and as directed by engineer in charge.
Supply of lightning surge counter (6 digit digital lightning surge counter), Complete all as specified and as directed by engineer in charge.
Supply of additional accessories (rope wire, lugs, clamp, flessner, hooks, etc..,), Complete all as specified and as directed by engineer in charge.
Supply of Disliking connection box, Complete all as specified and as directed by engineer in charge.
Labour only for installation of advanced lightning protection system ,with the help of additional accessories (rope wire, lugs, clamp, fastner, hooks,cable tie,nut ,Bolts & washer ,cable lugs etc..,) connecting down conductor from ESE devise to the earth electrode duly saddeled or fixed over supporting mast/wall/surface using reuisite( insulator/U shape saddle) wall/laid inhard standing /laid in floor including provision of suitable clamps and coupling,making connections with earth electrodes using exothermic welding/brazing ,necessary excavation/PCCfor laying conductor through,also including the provision of GI pipe medium grade 40 mm bore for protection of conductor upto 2 mtr above ground level and upto the earth , Complete all as specified and as directed by Engineer -In -Charge.
Supply,installl,testing & commissionning of 70 sq mm 1 core copper flexible wire (cable) polycab Make as a down conductor from air terminal to the earth pit, Complete all as specified and as directed by engineer in charge.
Material & labour for earthing in repairs including taking out old plate with pipes earthing lead fasteners etc and supply, install, testing and commissioning maintence free comprising of high tensile low carbon steel rod of 3 mtrs length & 17.2mm dia with 250 micron (average) molecularly bonded copper on the outer surface to confirm with the requirement of UL 467 placed in bore min 150mm dia upto 3 mtr deep in any type of soil / strata black soil, rock or any other along with back-fill compound strictly be a carbon based conductive concreate type which was resistively of less than 0.12 ohm mtr as per clause 14.5 D of IEEE:80 Standard back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for condition. Compound shall be suplied in sealed bags. The earth electrode should finally be housed in heavy duty concreate/PVC chamber with cover of size 300x300x300mm for future access. Back-fill compound should be enviroment freindly, should solodoty when mixed with water and sel like concreate and should not leach/diffuse into ground.
SHREE SAMARTH SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .