Loading…
Loading…
Tender Value
₹12.6 L
EMD Value
₹25,500
Closing Date
11 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
GE 861 EWS
GE 861 EWS
SPL REPAIR BY ADDN/ ALTERNATION TO LT PANEL , LED BOARD FITTINGS NEAR PUMP HOUSE , OFFICE COMPLEX AND CERTAIN E/M INSTALLATIONS AT KHANBAL MIL STATION UNDER GE 861 EWS
2026_MES_773438_1
GE 861 EWS-15(T)/2026-27
Open Tender
Civil Works
150 days
GE 861 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 861 EWS
₹25,500
GE 861 EWS
19 Jun 2026
19 Jun 2026
14 Jul 2026
19 Jun 2026
11 Jul 2026
4 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed by Engineer-in- charge. | 100.8 | Cum | - | - |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soilcomplete all as specified and as directed by Engineer-in- charge. | 47.85 | Cum | - | - |
| 3 | Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as specified and as directed by Engineer-in- charge. | 52.95 | Cum | - | - |
| 4 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as spefied and as directed by Engineer-in-Charge.
(Note:- Punned thickness shall be considered for payment purpose) | 38.22 | Cum | - | - |
| 5 | Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. | 4.74 | Per 1000 Nos | - | - |
| 6 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 95 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) | 100 | RM | - | - |
| 7 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 70 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) | 120 | RM | - | - |
| 8 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 50 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) | 105 | RM | - | - |
| 9 | Supply and laying replacement , jointing and testing galvanized iron 100 mm bore medium grade pipe (ISI marked) with and including all necessary fittings such as elbow, Tee, union , nipples etc as requried at site laid in trench complete all as specified and as directed by Engineer-in-Charge.Note: Earh work such as exavation, returning and removal shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ. | 12 | RM | - | - |
| 10 | Supply & Fixing in replacement off load Changeover switch , 415 volts , 50Hz ,TPN , 4 Pole , 100 Amps capacity, enclosed in sheet metal enclosure , floor/ wall mounter complete with handle mechanism, interlocking arrangements, connections , and all accesories compete all as per manufacturer's instructions , compete all as specified and directed by Engineer-in-Charge. | 3 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender15T.pdf
Tender Documents • 1.09 MB
BOQ_866033.xls
BOQ • 3.76 MB
credit15T.pdf
Additional Documents • 0.02 MB
Download all tender documents and submit your bid