Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.0 LAccepted-AOC SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹9.8 L+₹33,308 (3.50%)Rejected-Finance HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | Rejected-Technical | - | Rejected-Technical DOCUMENTS NOT FOUND IN ORDER. AS NOT SUBMITTED THE ELECTRIC LICIENCE | |
| 4 | Rejected-Technical | - | Rejected-Technical DOCUMENTS NOT FOUND IN ORDER. AS NOT SUBMITTED THE ELECTRIC LICIENCE | |
| 5 | Rejected-Technical | - | Rejected-Technical DOCUMENTS NOT FOUND IN ORDER. AS NOT ENLISHTED IN CATEGORY B(I) |
Tender Value
₹10.0 L
EMD Value
₹19,964
Closing Date
4 Sept 2024, 6:00 pmClosed
BRIJ BIHARI
LAKE VIEW CAMP TALBEHAT 284125
REPAIR/REPLACEMENT OF BLDGS ELECTRICAL FITTINGS AND FIXTURES, WIRING IN ZONE -14, 9C AND 10 AT MIL STN TALBEHAT
2024_MES_665159_1
AGE(I)/TBT/TOK-26/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TALBEHAT MIL STN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I TALBEHAT
₹19,964
27 Sept 2024
10 Jul 2024
6 Sept 2024
17 Jul 2024
4 Sept 2024
24 Jul 2024
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as directed.
Taking down carefully complete light fittings removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as directed.
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete. Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc complete.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Wire: Make -Mescab/Polycab/KEI/Havells/Finolex PVC conduit: Make -Polycab/Precision/Plaza/Kalinga Note:- (i) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories. (ii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quated.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item NO 5 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 4 sq mm for phase & neutral & 4 sq mm for earth continuity conductor.
M/L for point wiring in existing conduit with 1.5 sq mm FRLS PVC insulated unsheathed single core multistranded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in PVC rigid conduit with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators and making good disturbed surfaces of wall, floors etc for the following :- Wire :- Make -Finolex/V-guard/Polycab/KEI/Havells/Plaza PVC conduit :- Make -Polycab/Precision/Plaza/Kalinga Note :- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 Amps controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item No 7 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp. MAKE:- Havells/Anchor/Gold Medal/Cona
S&F Switch Piano Flush button single pole one way 15/16 Amp. MAKE:- Havells/Anchor/Gold Medal/Cona
S&F socket outlet 2 in 1, 5 pin & 2 pin, 5/6 Amp, 240 volt. MAKE:-Havells/Anchor/Gold Medal/Cona
S&F socket outlet 2 in 1 , 5 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. MAKE:- Havells/Anchor/Gold Medal/Cona
S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F step type electronic fan regulator flush type one way on the existing phenolic laminated sheet. MAKE:- Havells/Anchor/Gold Medal/Cona
S&F Lamp holder BattenType PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting with 9watt LED bulb. MAKE:- Havells/Anchor/Gold Medal/Cona
S&F Lamp holder angular type PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting including with 9watt LED bulb. MAKE:- Havells/Anchor/Gold Medal/Cona
S&F Bell Ding Dong type, AC 230 Volts, Single pole. MAKE:- Havells/Anchor/Gold Medal/Cona
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole. MAKE:- Havells/Anchor/Gold Medal/Cona
M&L for sub main concealed wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. (iii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quated.
M&L for sub main concealed wiring with two single core PVC insulated of size 4.0 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 20 mm external dia and conduit FRLS accessories of ISI marks medium grade including 4.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit two run of 4 sq mm copper conductor & one run of 4.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. (iii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quated.
S&F in replacement single pole and neutral enclosure with a two pin and earth socket complete with one single pole MCB of 20 Amp 240 volt. Make:- Legrand/Hager/Schneider/ndoAsian/Siemens.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps 240 volts double door (Metallic) type. Make:- Legrand/Hager/Schneider/ndoAsian/Siemens.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 4 way with 200 Amps, 240 volts double door (Metallic) type. Make:- Legrand/Hager/Schneider/ndoAsian/Siemens.
S&F MCB SP 5 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 32 to 40 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Supply and fixing LED building security light fitting, 15/20 Watt made up of pressure die cast aluminium housing, inbuilt driver, top opening, IP 66, 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge. Make Havells/Surya/Crompton/Philips
Suppl and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of sutable size complete all as aspecified and directed. Make : Havells/ Panasonic/ Surya
Supply and fixing LED 4' batten light 18/20 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge. Make Havells/Surya/Crompton/Philips/Bajaj
Supply and fixing LED 2' tube light fittings 9/10 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge. Make Havells/Surya/Crompton/Philips/Bajaj
Supply and fixing building securty light bracket bend type complete with 2.0m long G.I. pipe 40mm dia light grade, with suitble clamp and nut bolts complete all as specified and directed by EIC.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of Earth strip/ cables, on roof/pole/wall/laid in floor/in trenches. Make:- JINDAL/TATA/PRAKASH.
Supply and fixing LED Inverter Lamp Make : Shakti Cat Part No - SZBLB22009 - iBB 9W B22 or equivalent complete all as specified and directed. Make : Havells/ Philips/Surya /Crompton/Halonix/ Shakti
Supply and fixing Inverter Batten T/L fitting Make : Shakti Cat Part No - SZSLBMX018-iBB 18W 4 ft or equivalent complete all as specified and directed. Make : Havells/ Philips/Surya /Crompton/Halonix/ Shakti
Note :- (i) Disconnection of Geyser and fans from electric source, inspection of problem, taking down to ground, and transportation from site to market for repair/brazing will be deemed to be included in the rate quoted by the contractor without incurring any extra cost to the department. (ii) Srl Item No 11 and 12 will be issue under Schedule ,B, free for fixing only. (iii) Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
m/s bobby enterprises (BID ID -3073648)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .