| 1 | L1₹25.7 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹36.3 L+₹7.9 L (27.5%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L2 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Oct 2021, 6:00 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REPAIR/MAINT TO HT/LT OH LINES, HT/LT POLES, POLE PAINTING, STREET LIGHT, ELECTRICAL INSTALLATIONS AND CONNECTED ITEMS AT INS SHIVAJI, LONAVLA
2021_MES_474540_1
GE/LONAVLA/8013/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹80,000
Yes
25 Oct 2021
13 Sept 2021
11 Oct 2021
13 Sept 2021
8 Oct 2021
23 Sept 2021
13 Sept 2021 - 22 Sept 2021
Amount
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in hard/dense soil for laying of cable trenches all as specified and directed.
All as per item No.23 Herein before but in hard dense soil
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm all as specified.
Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified.
M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified. Note :- Cushioning will be measured and paid after punning down.
Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
Supply laying and testing cable XLPE insulated screened PVC beded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 50 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as specified and diercted.
All as per item no 7 above but of size 70 sq mm 3,1/2 core.
All as per item no 7 above but of size 25 sq mm 4 core.
All as per item no 7 above but of size 16 sq mm 4 core.
All as per item no 7 above but of size 10 sq mm 4 core.
Supply laying and testing in replacement cable XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cable heave duty with aluminum conductor 22000 volts earthed grade 3 core cable cross sectional area 120 sqmm
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size upto 50 sqmm,Indoor/Outdoor type complete all as specified and as directed.
All as per item No-13 but size 70 to 120 sqmm,Indoor/Outdoor type complete all as specified and as directed.
Supply and fix FR PVC insulated cable 1100 V grade with multistranded copper conductor of size 1.5 Sqmm 3 core conductor all as s specified and directed by Engineer-In -Charge at site
Supply and lay in trenches / along the wall / floor / on poles / pillars / for road / Nallah crossing, pipes GI light grade of size 50 mm dia with and including all fittings and accessories complete including taking down the old unsv all as specified and and directed for cable protection
Cutting and filling bituminus road as per direction of Engr in Charge for laying of UG cable and match the existing road to the existing system.
M&L for Scrubing of existing rusted surface of poles 11 mtr long and prepration and painting of surfaces with one coat of red oxide and two coat aliminium paint fine finishing includign cross arms bracing , clamps and supports complete all as specified and as directed.
All as per item No 18 above but of poles 9 mtr long
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized earth plate with 4.0 mm thick GI wire by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia for watering, with funnel and wire mesh including testing on completion. All as specified and as directed incl dismentling existing unsserviciable earthing .
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or ixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia GI wire.
Supply, fabricate, errect, connecting, testing, commisioning with replacement of LT Panel, Outdoor Type, weather and vermin proof made out of 3 mm thick CRCA sheet with front & Rear opening and locking arrangement, epoxy powder coated having colour siemens grey, 400 Amps capacity aluminium bus bar for phase, 3 No's and 1 No 400 Amp bus bar for neutral, mounted on epoxy insulator including neccessary copper control wiring, heat shrinkable, RYB coloured sleeves over bus bar for identification, earth shields, circular holes at bottom / top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required floor mounting angle iron frame made out mild steel angle iron of size 40 x 40 x 6 mm grouted on PCC (1:3:6) upto required height suitable for the following control/ fitments sensible for 3 phase, 50 Hz, 415 V system complete with and including following :- (a) Bus bar RYBN 400 Amp capacity - 01 Set (b) MCCB 400 Amp 4 pole 36 KA 415 Volt ( Incoming) - 01 No (c) MCCB 250 Amp 36 KA 4 pole - 02 Nos (d) MCCB 200 Amp 25 KA 4 pole - 03 + (01 Spare) (e) MCCB 160 Amp 25 KA 4 pole -01 Nos (f) MCCB 100 Amps 16 kA 4 pole -02 No + (01 Spare) (g) 01 Spare block for onload change over 250 Amps (h) LED Indicator lamp RYB - 05 Set (j) Digital multifunction meter (V, A, F, PF, KW, KVA)
Supply, fabricate, errect, connecting, testing, commisioning with replacement of LT pannels cubical outdoor type weather and vermin proof made out of 3mm thick CRCA sheet of suitable size with front and rear opening and locking arrangement epoxy powder coated having colour siemens grey 200 Amps capacity aluminium bus bar for phase 3 Nos and 1 No 200 amps bus bar for neutral mounted on epoxy insulator necessary copper control capacity control wiring heat shrinkable RYB coloured sleaves over bus bar for identification floor mounting angle iron base earth shields circular holes at bottom/top to receive incoming and outgoing cable. cable lugs, cable gland of size as required pannel suitable for the following control/filments sensible for 3 phase 50Hz 415V system complete comprising the following and including necessary PCC/Brick work for mounting of pannel. (a) 4 Nos bus bar high conductivity aluminium alloy strips proper insulated for phase (RYB) with 200 Amps & neutral rating 200 amps and mounting on porcelain support.- 01 Set (b) MCCB 250 Amp 4 pole 36 KA 415 Volt ( Incoming) - 01 No (c) MCCB 160 Amp 25 KA 4 pole - 01 (d) MCCB 100 Amp 16 KA 4 pole - 02 (e) MCCB 63 Amps 16 kA 4 pole -02 Nos (f) LED Indicator lamp RYB -Set of three-01No (g) Digital multifunction meter (V, A, F, PF, KW, KVA)
Renewal/ Repairs to LT Panel Board of any size complete as mentioned below:- (I) Repair/ replacement of damaged hinges of each compartment (ii) Taking down existing bus bars cleaning with CTC applying with becktol red solution, providing bus bar insulation and refixing with new s/s nuts, bolts, washers etc. (iii) Replacement of damaged copper flexible cable and fixing new copper flexible cable of suitable size for incoming and out going connections of each MCCB terminals to bus bars. (iv) Replacement of damaged/ worn out/ loose connections/ cable lugs for incoming & outgoing cables. (v) Replacement of u/s CT's, ammeters, Volt meters, Indication Lamps (01 Set each) including provision of new wiring for the same. Note : Ammeters and CT's shall be wired with 2.5 sqmm copper wire. (vi) Replacement of neoprene gasket for all doors of panel board. Note : i) Cost for replacement of spares are deemed to be included in the quoted rates. ii) The rate shall be deemed to be included for replacement of worn out rusted, Channels, hinges, bolts, split pins and cable lugs, cable glands and neoprene gasket with painting to all doors including raising of foundation to 0.3 M height etc. iii) Cost of replacement of MCCB's, Repairs to ACB's not included in the scope of work.
S&F in replacement of MCCB 415 Volt 16 KA, 4 Pole 63 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:ABB/Siemens/Havells.
All as per item No. 26 above but 100A, 25KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 26 above but 200A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 26 above but 250A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
Supply & fix in replacement of LED street light of 70 watt along with fixture.Make:Bajaj CAT Part No ENXT P 84L WH CR PC SD or equivalent to CG/Philips/Wipro complete all as specified and directed
Supply & fix in replacement of LED street light of 90 watt along with fixture.Make:Bajaj CAT Part No BRTFG 90W LED CR or equivalent to CG/Philips/Wipro complete all as specified and directed
Supply & fix in replacement of LED Flood light of 100 watt along with fixture.Make:Bajaj CAT Part No BJFL 100 W LED I or equivalent to CG/Philips/Wipro complete all as specified and directed
Supply & fix in replacement of decorative LED Bollard light 10 Watt .Make:Shanti electric Co or equivalent to Shakthi/Philips/Wipro complete all as specified and directed
Supply and fix in relplacement post top lantern for CFL lamp 1 x 18 watt with CFL lamp complete. Make - Crompton Greaves cat No CFPT 18 / bajaj / or Equvivalent
S&F in Timelite Distribution Board 65 Amp 3 pole / 230 Volt Digital Time Switch including Street Light Timer assembly( 01 Nos) comprising of Digital timer- FM1 Quartz with 3 Pole ML-2 Contactor duly prewired with bypass arrangement- 02 Nos, Digital Ampere Meter conformuing to DM 3258 of Conzerv Schiender-02Nos & LED Indicating Lamp for RYB phase indicator - 01 Set complete all as specified and as directed.Make Indoasian Cat Part No- TL065DBO or equivalent to Schindler / Indoasian.
S&F in Street Light Digital timer- FM1 Quartz with 3 Pole ML-2 complete all as specified and as directed.Make Indoasian or equivalent to Schindler / Indoasian.
S&F in Street Light Contactor duly prewired with bypass arrangement- 02 Nos complete all as specified and as directed.Make Indoasian or equivalent to Schindler / Indoasian.
Supply and errect steel tublar swaged poles type 410 SP-55 (11 metre long) conforming to IS complete with cast iron base plate, final taper plug, bolts, nuts and screws including painting with two coats of aluminium paint over a coat of red oxide primer above GL and taring for portion below GL (inside and out side) complete all as specified and as directed.
Supply and installation of Hot dip galavanised iron pole 7 mtr long sheet thickness 3 mm. C/s A/F - top = 70mm, bottom =130 mm, base plate 200x200x12 mm, long weatherproof reinforced door opening with junction box mounting arrangement but including of junction box with 4 Nos aluminium Bus bar and including 1.0 M long single arm bracket made of 40NB B class pipe having top 70 mm, 20 dia threaded made to J shape M20x600mm long steel grade EN8 grade foundation bolts - 4 nos with nuts, templates and all complete as per approved drawing (with internal accessorises like connectors,two runs of 1.5 sqmm single core copper multistranded conductor as per required and mcb) including taking down old rusted pole of any size by digging or cutting all as directed . Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1500 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups @ 190 mm c/c as per approved drawing(Including form work). This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, PCC, RCC,Form work and reinforcement shall be deemed to be included in qoted rates.
Supply & fix in replacement of SPD up to 50 KA complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
Supply & fix in replacement of LED DRIVER for 45 watt street light fitting complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
Supply & fix in replacement of LED DRIVER for 72 watt street light fitting complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
Supply & fix in replacement of LED DRIVER for 100 watt street light fitting complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
Taking down streetlight fitting / security lights / Building any type from pole /wall and refix the same in its own position including repair and replacement of unserviciable parts and testing complete . NOTE :-(i) Spares required to be replaced will be measured and paid separatel under respective item of Sch A. (ii) Rates quoted shall be deemed to include the cost of minor spares not catered for in the subject CA.
Supply, fabricate, errect, connecting, testing, commisioning with replacement of LT Panels cubical outdoor type, weather and vermin proof made out of 3 mm thick CRCA sheet of suitable size with front & Rear opening and locking arrangement epoxy powder coated having colour siemens grey 200 Amps capacity aluminium bus bar for phase 3 Nos and 1 No 200 Amps bus bar for neutral mounted on epoxy insulator neccessary copper control capacity control wiring heat shrinkable RYB coloured sleeves over bus bar for identification floor mounting angle iron base earth shields, circular holes at bottom / top to receive incoming and outgoing cable, cable lugs, cable gland of size as required pannel suitable for the following control /filments sensible for 3 phase 50 Hz 415V system complete comprising the following and including necessary PCC/Brick work for mounting of pannel. (a) 4 Nos bus bar high conductivity aluminium alloy strips proper insulated for phase (RYB) with 200 Amps & netural rating 200 amps and mounting on porcelain support.-01 Set (b) MCCB 250 Amp 4 pole 36 KA 415 Volt (Incoming) - 01 No (c) MCCB 160 Amp 25 KA 4 pole - 01 Nos (d) MCCB 100 Amp 16 KA 4 pole - 02 Nos (e) MCCB 63 Amps 16 kA 4 pole -02 Nos (f) LED Indicator lamp RYB - Set of three - 01 No (g) Digital multifunction meter (V, A, F, PF, KW, KVA)
SHAILENDRA B TULSANI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .