| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹21.9 L+₹3.0 L (16.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹25.1 L+₹6.2 L (33.1%)Rejected-Finance 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur-208008
REPAIR/MAINT OF SUMMER APPLIANCES AND CONNECTED WORKS AT 7 AFH KANPUR CANTT
2024_MES_678608_1
GE (AF) BR/CHK/T-41 OF 2024-25 8975/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
7 AFH KANPUR CANTT
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹50,000
Yes
23 Dec 2024
10 Oct 2024
15 Nov 2024
10 Oct 2024
8 Nov 2024
24 Oct 2024
Amount
M&L for Servicing of window type AC 1.0/1.5 TR /2.0 TR capacity from various location and any height, like first floor, for maintenance, including taking down wherever necessary , opening cleaning with Magna/Hibird solution , applying water/ air pressure, oiling including taking out old unserviceable parts and fixing new part complete with re-fixing at existing place after repairing , servicing , testing etc all as specified and directed.
All as per item No 1 here and before but split type cap 1.5 /2.0 TR capacity including suitable T&P for cleaning of indoor assembly and making good the disturbed surface or shifting of tables/beds/lockers etc all as specified and directed at site by Engr-in-charge. Note for item No. 01 & 02:- New components /parts shall be measured and paid separately as supply only under respective items.
Supply only following items for window/ split type ACs complete all as specified.
Starting capacitor 120-150, MFD
Starting capacitor 100 – 120 MFD.
Running capacitor 45 MFD.
Running capacitor 36 MFD.
Running capacitor 4/6 MFD.
Starting relay (as per sample).
Over load protector (as per sample) .
Micron filter suitable for window / split type AC of 1.5 Ton capacity
Thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity.
Contactors suitable for invertor Acs any type and capacity.
Remote control hand set with "AAA" batteries for window/split type AC's, of any model / make.
Plug top as per existing make, type suitable for AC control box.
Inlet /outlet valves suitable for window/split type AC any type and capacity.
Sensor for invertor type window/split Acs as per existing make.
PCBs suitable for Indoor/Outdoor unit Acs any type and capacity.
Cooling coil of window type AC any cap up to 2 ton .
Front grill of window AC suitable for 1.5/2 ton.
Fan blade suitable for window/split type AC any type and capacity.
Air blower moter as per sample suitable for window/split type AC of 1.5/2 Ton capacity single phase.
M&L for minor denting work outer portion metal part to window/Split type air conditioners of 1.5 / 2 Ton capacity including applying spray painting with a coat of synthetic enamel paint of required shade complete all as specified and directed by the engineer -in -charge.
Taking down unserviceable sealed unit and S&F with new hermatically company sealed unit compressor of following capacity single phase 230 volt welding/brazing of gas pipe line, vacuum pressure leakage, testing complete including charging refrigerant gas as required complete all as specified .
Sealed unit compressor 1.5 TR capacity.
Sealed unit compressor 2.0 TR capacity.
All as per item no 5 but rotary type compressor of 1.5 TR all as specified and directed.
Ditto - but 2.0 TR capacity.
S&F following type /capacity of motors suitable for window type AC/split AC complete all as specified.
FHP motor single phase of capacity 1/6 HP , 900 RPM, 220 V for 1.5 To 2 TR Capacity for window type AC/split AC.
ditto- but 1/8 HP.
Indoor unit motor suitable for 1.5 To 2 TR Capacity for window type AC/split AC.
Outdoor unit motor suitable for 1.5 To 2 TR Capacity for window type AC/split AC.
S&F in replacement for cooling coil of 1.5 TR capacity window/Split type AC including welding/ brazing of pipe line, charging of refrigerant gas and testing of leakage as required all as specified and directed.
Ditto- but for 2TR capacity.
Taking down indoor unit of Split Acs any type from site and rectification of water leakages from indoor unit, refix the same location after replacement of minor components of water leakage portions all as specified and directed. Note:- Replacement of minor spare parts pertains to water leakages included in the quoted rate.
S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia all as specified and directed.
Charging only of refrigerant gas (R-22) in window type / Split AC's after detecting the leakage of refrigerant gas in the system and testing complete all as directed. Note : Gas will be issued from supply only for relevent items .
1.5 TR cap window type AC
2.0 TR cap window type AC
2.0 TR cap split type AC
1.5 TR cap Split type AC
S&F PVC copper stranded cable 4 core 2.5 Sqmm suitable for connection of ACs any type and size all as directed .
Shifting of existing window type A/C of any capacity from one location to another location including closing openeing with brick work in CM 1:6 and its installation by cutting holes in window/walls making good disturbed surfaces in CM (1:4) and applying two coats of cement base paint and matching with existing colour paint complete all as directed .
Shifting of existing split type A/C of any capacity from one location to another location complete pumping down refrigerant gas into compressor including disconnecting electrical/ gas connections and making good disturbed surface in CM (1:4) with existing one and its installation by making necessary electric connection incl brazing and refixing complete all as directed.
M & L for providing new insulation on existing copper pipe of split AC incl providing 0.64 mm thick aluminium sheet cover ,made to shape as required at site insulating materials for protection from Monkeys menance and weather etc complete, testing all as directed by Engr-in-Charge.
S&F copper pipe along with PVC cushion o size 5/8" dia all as specified and directed.
Ditto- but of size 1/2" dia
M&L for split type AC outer unit stand made of iron including grouting for fixing with nut, bolts and washers all as specified and directed.
REFRIGERATOR Servicing of refrigerator of any make and capacity from various location for maintenance including taking out old unserviceable parts and replacing with new parts and re-install the same at existing place after repairing, servicing and testing complete all as directed. Note :-Spare parts shall be measured & paid separately as supply only for relevent items.
Supply only in replacement following items for for refrigerator complete all as directed.
Thermostate as per existing make.
Thermostate switch as per sample
Relay as per existing.
Bulb 230 V,12 W as per sample.
Ice tray PVC 18 cubed as per existing model.
Aluminium Chiller box as per sample suitable 165 to 200 ltrs capacity
Aluminium Chiller box as per sample suitable for 285 to 310 capacity
Defrost switch as per sample
PVC Chiller tray suitable for 165 to 200 ltrs capacity
PVC Chiller tray suitable for 285 to 310 ltrs capacity
PVC Freezer door 165 to 200 ltrs capacity as per sample
PVC Freezer door for 285 to 310 ltrs capacit as per sample
Plug top 5 Amps 230V suitable of refrigerator.
Supply and fixing in replacement new sealed unit compressor capacity of 285/300/310 ltr, welding the same with existing refrigerant pipe, leakage testing/vaccum test, supply & charging of refrigerant gas of adequate quantity testing complete all as specified and directed.
Ditto- but 165/180/195/200 ltrs capacity refrigerator
S&F in replacement of condenser coil suitable for 165/180/195/200 Ltrs capacity refrigerator including Welding/brazing of pipe lines, cahrging of refrigerant gas and testing complete.
Ditto- but for 285/300/310 ltrs capacity refrigerator.
Material and labour for denting,cutting and replacing of rusted/ damaged outer cabinet of 285/300/310 ltrs capacity refrigerator with existing shape and size PBI sheet complete with and including spray painting with one coat of synthetic enamell paint over a coat of primer after proper scrapping of old painted surface of refrigerator of approved shape and getting it up to mark in its original position including necessary welding work, making holes for fixing of compressor complete all as specified and directed.
Ditto- but for 165/180/195/200 ltrs capacity refrigerator.
WATER COOLER M&L for Servicing of water cooler of any make & type of capacity 40/80/150 by disconnecting electrically & mechanically,from various location for repair and maintenence including cleaning condenser coil and storage tank with chemical base solution and soda water and repalcement of unserviceable parts and refixing , re-connecting electrical and water connections, testing complete all as specified and directed. Note :- New components/parts shall be measured and paid separately under respective items.
Supply only following item for water cooler complete all as directed :-
Starting capacitor 40-60 MFD.
Starting relay as per existing make.
Running capacitor 10 MFD.
Thermostate as per sample.
PVC float valve with PVC ball ,15mm dia as per sample.
Push tap self closing Chromium plated 15mm dia as per sample.
Brass nipple with GI socket 15mm dia duly welded with tank.
S&F in replacement sealed unit compressor single phase, 230 V and for water cooler, welding/brazing of gas pipe line, vaccume/ pressure leakage testing etc,supply and charging of refrigerant gas of adequate quantity complete and testing complete all as specified and & directed for the following capacity :-
40 Ltr Capacity.
80 Ltr Capacity.
150 Ltr capacity
S&F in repair condensor coil complete with copper tube and aluminium fins for water cooler of cap upto 80 Ltrs and including necessary refrigerant gas charging and testing complete all as specified and directed.
S&F in replacement of sheet metal enclosures with 2 pin and earth plug single pole neutral link and one No MCB SP 40 Amps complete all as specified.
M&L for sub main wiring with 2 runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC rigid conduit 20 mm dia with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking down old sub main wiring all as specified. Note. Three run of cable and one run of PVC conduit shall be measured as one run and type of wiring as per existing surface/concealed all as directed by Engr-in Charge.
S&F in replacement of FHP motor single phase suitable for 40 ltrs capacity water cooler of approved make complete all as specified and directed.
Ditto- but for 80 ltrs water cooler.
Shifting only water cooler of any capacity, any height at various location like Ist floor etc with fitting/grouting nut, bolts and making connection of electrical & water supply incl testing complete all as specified & directed.
S&F in replacement 15mm dia GI tubing medium grade with all necessary fittings such as bend, elbow, socket tee, union etc including making good disturbed surface complete all as specified and directed.
Supply and fix in repair Gun metal gate valve with iron wheel head screwed both ends suitable for GI pipe of size 15mm dia bore all as specified & directed.
Supply and fix in repair stop valve with crutch or butterfly handle screwed down screwed both ends suitable for GI pipe of size 15mm dia bore all as specified & directed.
Supply and fix in repair PVC connection pipe 15 mm dia x 45 mm long
Supply and fix in repair PVC connection pipe 15 mm dia x 60 mm long
Supply and fix in repair PVC flexible waste water pipe 40 mm dia
Material and labour for denting,cutting and replacing of rusted/ damaged outer cabinet of of 40 ltrs capacity water cooler with existing shape and size PBI sheet complete with and including spray painting with one coat of synthetic enamell paint over a coat of primer after proper scrapping of old painted surface of water cooler of approved shape and getting it up to mark in its original position as per existing including necessary welding work, making holes for fixing of compressor complete all as specified and directed.
Ditto but 80 ltrs capacity water coolers.
DESERT COOLER M&L for servicing of desert coolers of any size/any height by taking down from the existing position,cleaning of bottom tank, side panel etc including repair/replacing unserviceable parts including painting one coat after preparation of surface with synthetic enamel paint of approved quality and colour on internal & external surface complete all as specified and directed. Note:- Spares parts required shall be measured and paid separatley under respective items.
Supply only following item for deser cooler complete all as directed :-
Capacitor 4 MFD.
Indicator lamp rounded /rectangular shape
Piano type switch one way 5 Amp 240 V.
S&F Plug top 5 Amps, 230 Volts.
PVC distributor 3 way
PVC Pipe transparent heavy duty ½ inch dia.
Wood wool pad 15mm thick made out of chicken wire mesh fitted with fine quality wood wool , bind with GI wire for desert cooler of any make size complete.
Submersible water lifting pump for desert cooler 220/230 V single phase .
Blade assembly any design/shape for 18'' sweep air intake fan of desert cooler.
PVC insulated and PVC sheathed cable with stranded copper conductor of size 1.5 sq mm (19/0.0076) 3 core.
M&L for replacement of desert cooler cabinet locally fabricated 3 side povets , top cover and bottom tank including removable vertical members with fins/grills made out of 22 SWG MS Sheet with adjustable front grills version and base suitable for 18” sweep exhaust fan and making holes, PVC distributor 3 way, PVC pipe 3 to 4 Mtr, wood wool pad 3 Nos, internal wiring with 5A switch Piano type , light indicator size not less than 65cmx65cmx135cm (Water tank height not less than 35 cm ) all as specified and directed.
M & L fabrication of pedestal stand for size 65x65X75cm suitable for desert cooler made out of angle iron 35 x 35 x 6mm painted with one coat of black paint over a coat of red oxide primer complete all as specified and directed.
M&L for repairs to Air intake fan motor 18" sweep, 900 RPM any make and size by rewinding of stator with super quality enamelled copper wire of existing size, varnishing, heating, replacement of kit consist of ball bearings, motor shaft, shaft seal, bushes including painting with one coat of synthetic enamel black paint and re-install in the desert cooler at site and testing complete all as specified and directed.
DEEP FREEZER Taking out deep freezer of capacity 262 to 320 ltr from various location for repair including refixing at site after repair, cleaning the complete condenser coil & storage tank with chemical base solution and soda water and for complete restoring electrical connection and testing complete up to satisfaction of Engineer-in-Charge. Note :- Spare Parts shall be measured and paid separately under respective items .
Supply only following item for deep freezer complete all as directed :-
Starting capacitor 80/100 MFD .
Running capacitor 30 MFD .
Starting relay as per existing make.
Filter two way
S&F in replacement of sealed unit compressor hermatically company sealed for deep freezer of capacity 262 to 320 Ltr, single phase, 230 V and welding/ brazing of gas pipe line, vaccume pressure leakage testing etc incl supply and charging of adequate quantity regrigerant gas , welding/brazing of copper pipe & testing complete all as directed.
M&L for replacement of FHP motor suitable for 262 to 320 ltrs capacity deep freezer complete including all necessary works complete all as specified and directed.
VOLTAGE STABILIZER Dismantling of voltage stabilizer upto 5 KVA capacity complete for maintenance, repair and replacement of worn out /unsv spares, overhauling & re-assembling including testing and commissioning complete. Note :- Spare parts shall be measured and paid separately under respective items supply only.
Supply only following item for stabilizer complete all as specified
Voltage shown disply/Voltmeter ranges from 0 to 300 Volts for 0.5 , 2, 4 & 5 KVA voltage stabilizer as per existing make and type .
Terminal socket 3 Pin 15 Amp.
Terminal Connection 4 way.
Indicator lamp for 0.5, 2, 4 & 5 KVA stabilizer
Main relay for stabilizer SP 5 KVA
PCB switch transistor , diodes , resistance for different cap 5 KVA of voltage stabiliser as per existing make.
Plug top 3 pin 15 Amp, 240 Volt.
M&L for re-winding of main transformer 5 KVA voltage stabilizers any make and size with super quality enamelled copper winding wire of existing size/guage, insulation materials, varnishing, heating, re-assembling including testing off and on load complete all as specified and directed.
All as per item No 55.00 but 4 KVA capacity .
M&L for spray painting of voltage stabiliser of any make and capacity at different location with one coat of super enameled synthetic paint of approved colour including scraping cleaning of old painted surfaces all as specified and directed.
WALK IN COOLER M&L for repair/overhauling and servicing of walk in cooler of any make and capacity/type by opening the fan cover, blade, bushes internally & externally and providing fresh lubricant and re-assembling the same after repair/over hauling complete all as directed. Note:- Spare parts shall be measured and paid separately under respective items.
Supply only following item for walk in cooler complete all as specified and directed.
‘V’ Belt as per existing.
Thermostatic expansion valve.
Gas filter assy Make as per existing make.
Solenoid valve .
High and low cut off switch
DOL starter type MK-I relay range 6-10 Amp.
Contactor as per existing
Door gasket complete as per sample
Single phase preventor suitable for existing walk in cooler capacity.
S&F in replacement sealed unit compressor unit 1.5 TR capacity single phase, 230 V and for Walk-in-cooler, welding/brazing of gas pipe line, vaccume/ pressure leakage testing etc,Supply and charging of refrigerant gas of adequate quantity complete and testing complete all as specified and directed.
M&L for re-winding of motor upto 5 HP cap 3 phase for walk-in-Cooler with super quality enameled copper winding wire of existing guage including insulation materials, varnishing, heating re-assembling incl taking down the old U/S motor from existing location & re-installing in the original position after re-winding & testing complete all as specified and directed.
M&L for Charging only of refrigerant gas (R- 22) in walk-in-cooler after detecting the leakage of refrigerant gas in the system incl welding brazing and testing complete for all as directed. Note : Refrigerent shall be issued under the relavent item as supply only.
FOUR/TWO BODY STRUCTURE Taking down carefully unserviceable parts of four body/two body structure such as door inter locking system, temperature guage, starting capacitor, running capacitor, door gasket, sealed unit compressor etc incl replacing unservicable parts and cleaning, servicing and over hauling of both structure and testing complete Note:- Old unserviceable /spare parts shall be measured and paid separately under respective items.
Supply only the following parts of four body/ two body structure complete all as directed.
Door locks system as per existing.
Temperature Gauge as per existing make.
Starting capacitor 80-100 MFD.
Running capacitor 36 MFD
Magnet door gasket as per existing.
Capillary of existing size.
Temperature gauge + 4C to + 2C
Dryer
S&F in replacement of unserviceable cut open sealed unit compressor of two body structure with new hermatically company sealed unit compressor , single phase, 230 V and welding/ brazing of gas pipe line, vaccume pressure leakage , testing etc including supply and charging of regrigerant gas, welding of copper pipe & testing complete all as specified and directed.
M&L for Pumping down/de-caning the complete existing gas from the system of four/two body structure into to empty cylinder with and including cleaning it with nitrogen complete all as specified and directed.
Charging only of refrigerant gas in four/two body strucuture retrived here in before and testing in all respect complete all as specfied ad directed. Note : New Refrigerent if required, shall be issued under the relavent item as supply only )
Supply only of refrigerant gas Mafron (R-22) conforming to IS-5160 duly filled in sealed cylinder complete all as specified and directed. Note:- Gas cylinder arranged by the contractor and deposit to store yard all as directed.
Supply only of refrigerant gas R-134 confirming to IS – 5160 duly filled in factory sealed cylinder all as directed.
Supply only of refrigerant gas R-410 confirming to IS – 5160 duly filled in factory sealed cylinder all as directed.
Supply only of refrigerant gas Mafron (R-32) conforming to IS-5160 duly filled in sealed cylinder complete all as specified and directed.
Servicing and maintenance of UPS of Cap 30 KVA suitable for three phase in put and three phase out put installed at OT, ICU,Peadiatric Ward, Dhanwantry & NICU at 7 AFH by highly skilled Mechanic(from authorised dealer/manufacturer ) including proper cleaning of dust etc from in side and out side with suction blower including replacement of minor parts such as lugs /internal copper wires/ /thimbles tightining of loose Battery connections etc (Spare parts shall be paid seperately). Note:- Checking and regularised the load balancing and testing from the period of every three month with proper dusting ,cleaning of internal electronic acessories inside of UPS and produce load and test results to Engr-in Charge.
Supply only the following parts of UPS of Cap 30 KVA complete all as directed.
Main Card suitable for 30 KVA UPS
Charger Card suitable for 30 KVA UPS
IGBT Card with connector plate Suitable for 30 KVA UPS
AC Capacitor suitable for 30 KVA UPS
DC Capacitor Suitable for 30 KVA UPS
Silicon controler rectifier
Cooling fans suitable for 30 KVA UPS
Rotary regulator switch suitable for 30 KVA UPS
Voltage control internal transformer suitable for 30 KVA UPS
Maintenance free batteries capacity,42 AH, suitable for 30 KVA UPS with connecting leads up to panel board etc complete all as specified and directed.all as specified and directed.
Servicing,repair and maintenance of UPS of capacity up to 5KVA suitable for single phase by highly skilled Mechanic(from authorised dealer/manufacturer ) including proper cleaning of dust etc from in side and out side with suction blower including replacement of internal damaged electronics and elctrical parts as per site requirement as and when required like voltage control transformers , burned out control cards and its connected acessories,relays etc replaced including all connected spare parts all as specified and directed.(Replacement of Battery only paid and measured separately as "supply only" balance spare parts included in the quoted rate.) Note:- Checking and regularised the load balancing and testing from the period of every three month with proper dusting ,cleaning of internal electronic acessories and produce test load results to Engr-in Charge.
Supply only of maintenance free batteries capacity 65 AH,12V DC suitable for Single phase UPS, up to 5KVA and connecting lead with sockets etc complete all as specified and directed.
S & F in replacement energy meter three phase prepaid of capacity 10-100 Amps as per sample, four wire system including its all connected acessories all as specified and directed . Note:- Old Meter shall be deposited in Store yard of AGE Hosp by the contractor without any extra cost
M&L for replacement of electric shock proof anti-static (electristatic discharge (ESD)) floor mat 3mm thick surface resistance 10.6 to 10.9 ohms, static voltage 100 V, for any plant floor complete all as specified and directed by Engineer-in-Charge.
Servicing of Air curtains any type by taking down from site for servicing and greasing, cleaning inside and outside, as and when required, replacement of internal motor and other minor parts etc with new one as per existing complete all as specified and directed.
M & L for writing SM / MES No. of summer cooling appliances, water coolers, desert coolers, refrigerators and Air Conditioners with synthetic enamel paint or stickers equivalent of approved color complete all as specified and directed.
AARADHIRAJ ASSOCIATES (BID ID -3156064)
VISHAL TRADERS (BID ID -3155467)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .