Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.7 L+₹1.2 L (5.10%)Rejected-Finance COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L2 | Rejected-Finance L2 | |
| 3 | L3₹27.8 L+₹4.2 L (18.0%)Rejected-Finance 229 2 HP SHASTRI ROAD NETAJI PALLY POST RABINDRA SARANI SILIGURI 734 006 | SILIGURI | COOCH BEHAR | WEST BENGAL | 734006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹28.6 L+₹5.0 L (21.4%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Nov 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, CED, COB, SUNITY ROAD
Executive Engineer, PWD Cooch Behar Electrical Division
WBPWD/EE/CED/e-NIQ08/20-21
2020_WBPWD_295756_1
WBPWD/EE/CED/e-NIQ-08/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
25 days
ALIPURDUAR
Please refer tender documents
5 documents required · 5 mandatory
₹50,000
Yes
16 Mar 2021
9 Sept 2020
11 Nov 2020
9 Sept 2020
9 Nov 2020
9 Sept 2020
120 days
Amount
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size. [ Make:Havells/ Nicco / Fort Gloster ]
4 Core 95 Sq. mm from DG Room to sub panel
4 Core 120 Sq. mm from DG To Main panel
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core 95 sqmm
4 Core 120 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 Core 95 sqmm
4 Core 120 sqmm
Supply, Installation , testing & commissioning of cubical type back openable , compartmentalized , floor mounted, indoor type, dust & vermin proof power coated panel board for Essential & Non-Essential, suitable for 415V, 3 phase, 4 wire, 50Hz. AC supply of suitable size made out of 2mm thick MS sheet so as to accomodate the following mountings complete with CU
bars of 400A capacity , detachable gland plate, 100mm x 40mm x 4mm thick MS channel frame at the bottom, connections , interconnetions with adequate size CU wire , CU bars , CU links , cables , connectors etc , alongwith necy nuts & bolts , clamps , grouting bolts incl providing & fixing the following access etc compl as reqd (All ABB/L&T/Simens make)
INCOMING ARRANGEMENT a) 315A 415V, TPN SFU open execution in existing SS enclosure / cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating - 1 no b) 315 A 4 bar CU Bus-bar - 1 no
Supplying and fixing 315A, 415V, TPN on load front operated Changeover switch open execution type in SS enclosure/cubical with nuts bolts etc
OUTGOING ARRANGEMENT a) 250A 415V, TPN SFU open execution in existing SS enclosure/ cubical with nuts bolts etc incl. -1 NOS
OUTGOING ARRANGEMENT a) 100A 415V, TPN SFU open execution in existing SS enclosure/ cubical with nuts bolts etc incl. -2 nos
OUTGOING ARRANGEMENT a) 63A 415V, TPN SFU open execution in existing SS enclosure/ cubical with nuts bolts etc incl. -2 nos
Sliding fuse to be provided for voltmeter & indicating lamp set with lamps with HRC fuse type (sliding fuse) indicating lamp set (Make of indicating lamp - L&T)- 1 set e) 100A capacity 4 pole connector for outgoing connection for switches. I/c & O/g connections & interconnections is to be done with adequate size of CU cables, CU links , connectors etc
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level including excavation of soil & restoring surface duly rammed for soft Soil by ISI-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming for Soft Soil
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F 6 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
80 mm dia
Supply of 2.0 Ton capacity (23960 BTU ) having COP 3.29 Split Air Conditioning Machine filled with rotary compressor having cooling capacity 7020 Watt, Air flow volume 636 CFM, suitable for 230V, 50 Hz single phase power supply. ( Make- Jalim/ Mitsubishi Electric/General )
Installation charges of 2.0 Ton Split R.A.C. Machine incl. making arrangement for out door unit by suitable size angle iron frame as per direction of E.I.C.
Supply & Drawing 3/8” and 5/8” Copper pipe with 12.5 mm thick nitrile rubber insulation over it along with other accessories on wall make approved by EIC
Supply & Laying of Drain flexible pipe for condensed water.
Supply & Laying of PVC pipe 40 mm dia make Filolex/Supreme for condensed water.
SITC of 3Ø Silent Type Diesel Generating Set having Prime power Rating of 125 KVA at 415V, 50Hz, 0.8 lagging Power Factor on the existing foundation comprising of Engine, alternator, AMF panel, Base frame, Fuel tank, Battery, Acoustic Enclosure and other accessories as specified below
ENGINE
Make : Caterpiller / Cummins -Jakson
Engine Type : 4 Stroke Diesel Engine
Rated Output : 159 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 6
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 750 Ltrs.
a. Fuel Consumption at 75% rated Load with Radiator or Fan : 81.6 Ltr./ Hr. or Less b.Fuel Consumption at 100% rated Load with Radiator or Fan : 106 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator.
Exhaust Silencer : Residential Type
Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
ALTERNATOR
Make : Leroy Somer / Stamford
Rating : 415 V., 3Ph. 50 Hz., 125 KVA,
Type : Brushless, self excited and self regulated through AVR
Insulation : Class H
Protection : Screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF PANEL
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 125 KVA DG set having following specification/features
a. Suitable Capacity EDO type ACB make Siemens/LT-2/3 nos with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc
b. In Built By-Pass switch for rated capacity (On load changeover switch of suitable capacity make ABB/LT/Siemens)
c. On -delay timer for load change over
d.On-delay timer for engine shut off
e. Engine On-Off switch (Push button type)
g.Indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on' etc.
h.Audio visual alarm for Low lubricating oil pressure, High water temperature, Start failure, and DG over load
j. Microprocessor based relay with composite meter for digital display of following.
1. Generator voltage/AC Mains voltage.
2. Generator Current in all phases
3. Frequency
4. Power Factor
5. Energy
6. Indication for alternator supply
7.Running time indications number of hours of operation and service intervals, service due indications
k. The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure and vice versa
ACQUISTIC ENCLOSURE
The DG set will have high quality integrated acoustic enclosure duily designed in accordance and certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i)All materials, equipments & accessories must conform to relavent IS specifications with latest ammendments.
(ii) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(iii) All materials, equipments & accessories must conform to relavent IS specifications.
(iv) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(v) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(vi) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vii) The entire set must be warranted atleast 15 months from the date of Delivery/12 months or 5000 Hrs running from the date of Commissioning whichever is earlier. However Engin & Alternator should be warranted of 2 years/5000 Hrs running, whichever is earlier.
Providing cement concrete foundation for the DG set with 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)[M20 grade ] including excavation, providing base concrete with 1:5:10 cement concrete, required centering/ shuttering, finishing the exposed portion etc. as reqd. ( Item will be paid based on measurements for 1:2:4 CC, but excluding the 1 : 5: 10 leveling course of base concrete) as per direction of E-in-Charge and manufacturer recommendation.
Supply, Delivery including transportation of HSD Oil
Supply, Delivery including transportation of Mobil Oil
S & Delivery of 200 Ltr. Capacity Container made of heavy guage M.S. Sheet container.
S & Delivery of best quality oil hand pump with 1” dia PVC flexible pipe (12’ ft. approx)
S &F MS angle iron structure made of (80x80x6) mm/(50x50x6) mm MS angle to support 250 mm dia MS pipe &Fuel tank support for 125KVA DG set incl. painting as per per GS.
Supply & fixing of exhaust gas piping of suitable dia welded black 250 mm dia MS class B pipe incl. all necessary bend supports and clamps anti vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) for 125 KVA DG set as per direction of EIC.
Painting the 250 mm dia MS black pipe by Aluminium paint of two coat over the RO primer (approved make)
S&F rain protection canopy for 250 mm exhaust pipe
S&F atomatic timer switch for 2TR ac machine (for single phase) make OPTO / approved.
CENTRAL ELECTRIC CO.
M/S. A.D.ELECTRICAL ENTERPRISE
M/S DAS ENTERPRISE
stage.html
html • 0.05 MB
technical_551432.pdf
PDF • 0.20 MB
techsummary_551432.pdf
PDF • 0.04 MB
finance_551432.pdf
PDF • 0.18 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_551432.pdf
PDF • 0.04 MB
NIQ08AOC.pdf
PDF • 0.26 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .