| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC aoc |
| 2 | L2₹1.4 Cr+₹1.8 L (1.32%)Rejected-Finance | ₹1.4 Cr+₹1.8 L (1.32%) | L2 | Rejected-Finance EMD REFUND |
| 3 | L3₹1.5 Cr+₹6.9 L (4.97%)Rejected-Finance | ₹1.5 Cr+₹6.9 L (4.97%) | L3 | Rejected-Finance EMD REFUND |
| 4 | L4₹1.6 Cr+₹19.9 L (14.3%)Rejected-Finance 43 RR ARCADE CHAMBER NO 04 ZONE II M P NAGAR BHOPAL M P | BHOPAL | BHOPAL | MADHYA PRADESH | ₹1.6 Cr+₹19.9 L (14.3%) | L4 | Rejected-Finance EMD REFUND |
| 5 | L5₹1.6 Cr+₹21.2 L (15.2%)Rejected-Finance E 710 ANNAPURNA COMPLEX NEAR P AND T CHOURAHA KOTRA SULTANABAD BHOPAL | BHOPAL | BHOPAL | MADHYA PRADESH | ₹1.6 Cr+₹21.2 L (15.2%) | L5 | Rejected-Finance EMD REFUND |
Tender Value
₹1.7 Cr
EMD Value
₹84,741
Closing Date
17 Jan 2022, 5:30 pmClosed
P K JAIN
NEAR Smart City Office TATPAR PETROL PUMP, ENGINEERING HEAD OFFICE BMC BHOPAL
CONSTRUCTION OF FIRST FLOOR OF COMMERCIAL SHOPPING COMPLEX PHASE-1 AT NEELBAD TIRAHA ZONE 06 BHOPAL
2021_UAD_173847_1
2020204582
Open Tender
Civil Works - Buildings
Percentage
270 days
PHASE-1 AT NEELBAD TIRAHA ZONE 06 BHOPAL
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹12,500
₹84,741
15 Jul 2022
17 Dec 2021
18 Jan 2022
17 Dec 2021
17 Jan 2022
17 Dec 2021
Amount
CONSTRUCTION OF FIRST FLOOR OF COMMERCIAL SHOPPING COMPLEX (PHASE-1) AT NEELBAD TIRAHA ZONE 06 BHOPAL
Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 1239/3589 i/c fittings like elbows, tees, anges, reducer, jointing with nuts bolts, gaskets and welding etc.and fixing the pipe on wall/ ceiling with sutable hangers, clamps,supports, as required and painting with two or more coats of synthetic enamel paint of required shade complete as directed by Engineer-in-Charge. 100mm dia
Providing, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required. 100mm dia
Providing, installation, testing and commissioning of dual plate non- return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 100mm dia
Providing, installation, testing and commissioning stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet with 3 mm dia holes with stainless steel flange. 100mm dia
Providing and fixing first- Aid hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with the following as required. (a) 30/36m long, 20 mm (nominal internal dia) water hose thermoplastic (textile reinfirced ) type -2 as per IS 12585 (b) 20mm (nominal internal) dia gun metal globe valve and nozzle. (c) Drum and brakets for fixing the equipments on wall. (d) Connections from riser with 40 mm dia stop valve (gun metal) and M.S. pipe.
Supplying installation testing and commissioning of TAC approved electrical motor driven Terrace pump suitable for autometic opertion consisting of following- (i) Horizontally mounted Booster pump complete for delivery of 450 liters per minuts against a total head of 30 mtr so as to ensure a min. pressure of 2 Kg /sqcm at the highest and outlet at the specified flow complete with necessary strainers, pressure gauge. (ii) Squirel cage induction motor suitable for 415 volt 3 phase of suitable HP for the above pump and flexible coupling with the pump. (iii) Common base frame fabricated by mild steel channel suitable for above motor pump each. (iv) Suitable cement concrete pump foundation and vibrating mounting pads as required. (v) Pressure switch for pump for autometic operation I/c necessary wiring upto control panel. (vi) Direct -on line starter .
Supplying and installation of Fire GI buckets 3 nos. duly painted with red oxide and synthetic enamel paint and filled with sand, on existing stand complete as required.
Supplying and fixing of following type of ISI mark fire extinguisher with required clamps and other material complete as required. 5 Kg. ABC dry chemical powder type
(B) Supplying and fixing of following type of ISI mark fire extinguisher with required clamps and other material complete as required.4.5 kg. BC CO2 type
Providing, Fixing, Testing and Commissioning the following Supply and install following PVC insulated multistrength FRLS copper wire, 1100v grade, 2C x 1.5 Sq.mm, through MS conduits / surface / recess / above false ceiling /concealed space / wall concealed, etc. for control cabling of Fire detection and alarm devices and interconnecting them to manufactured and tested confirming as per IS:694‐ 1990 & 7098‐1988 & 1554 part‐I & ISI marked
Providing and fixing single headed hydrant valve with instaneous female Gun metal couplings of required dia with cast iron wheel lSI marked conforming to IS 5290 (Type ‐A) with blank gun metal cap and chain, adopter as required complete as directed by Engineer‐in‐ Charge.63 mm dia
Providing, installation, testing and commissioning of gun metal valves of following sizes as required.25 mm dia.
Providing and fixing hose cabinet of size 700mm x 600mm x 300mm made of 16 gauge thick MS sheet with 4 mm thick float glass doors in front painted "FIRE" in red paint i/c necessary locking arrangement suitable to accommodate internal hydrant with butterfly valve 2 nos. 15mtr. Long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respects for internal hydrant, as directed by Engineer‐in‐Charge.
Providing and fixing 63mm gun metal branch pipe with 20 mm (nominal internal diameter) size gun metal nozzle conforming to IS 903, suitable for instaneous connection to interconnect hose pipe coupling as required.
Providing and fixing 2 way fire brigade connection (FBC) of CI body with 2 nos. gun metal male instantaneous inlet couplings complete with cap and chain as required. For 150mm dia MS pipe connection, confirming to IS 904 as required.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing pressure transducer (dial type pressure gauge with isolation cock) in MS pipe line (dial diametre 100mm pressure range 0‐10 kg/cm) suitable for 12 volts 124 DC. Including connection etc. as required.
Providing and fixing Pressure switch in the MS pipe Line including connection etc. as required.
roof top harvesting from roof slab to Ground floor (each building higt up to 6.00 metar) including all fittings, jointing material with bypass arrangement.( tee,bend,socket nad clamp )with all lead and lift or hight.etc complet.as par disgin. size of pipe 110 mm dia mack of pipe kasta, kisan and plasto .working pressir of pipe 4.00 kg / sqmt
PVC GATE VALVE (SIZE OF VALVE 110 MM DIA ) UP TO 1000 SQ.FIT
Bidder Name
Amount
M/s Sunil Gupta(GSTN-23ABSPG4099E1ZI)
BARUN BUILDERS AND CONSULRANT(GSTN-23AXMPK8856F1Z4)
D S DEVELOPERS(GSTN-NA)
MS RSONS INFRA(GSTN-NA)
MRIG CONSTRUCTIONS(GSTN-NA)
IMPERIOUS ELECTRO AND INFRATECH PRIVATE LIMITED(GSTN-NA)
M/s Sunil Gupta
MRIG CONSTRUCTIONS
IMPERIOUS ELECTRO AND INFRATECH PRIVATE LIMITED
BARUN BUILDERS AND CONSULRANT
MS RSONS INFRA
IMPERIOUS ELECTRO AND INFRATECH PRIVATE LIMITED
M/s Sunil Gupta
MS RSONS INFRA
MRIG CONSTRUCTIONS
BARUN BUILDERS AND CONSULRANT
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .