Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹35.3 L+₹4.2 L (13.6%)Rejected-AOC GURUDWARA LANE PORT BLAIR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | 2 | Rejected-AOC Not L1 | |
| 3 | 3₹35.7 L+₹4.6 L (14.9%)Rejected-AOC | 3 | Rejected-AOC Not L1 | |
| 4 | 4₹45.8 L+₹14.7 L (47.3%)Rejected-AOC 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | 4 | Rejected-AOC Not L1 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
16 Oct 2020, 6:00 pmClosed
BIRCHGUNJ
GE BIRCHGUNJ
PROVISION OF RADIO DET ROOM, STREET LIGHT LIGHTENING ARRESTER ADDN/ALTN TO SURVEILLANCE TOWER AT BRICHGUNJ MIL STN PORT BLAIR UNDER GE BRICHGUNJ
2020_MES_378814_1
8078A GEBG
Open Tender
Civil Works
Item Rate
180 days
BIRCHGUNJ
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE BIRCHGUNJ
₹2.3 L
Yes
2 Dec 2020
18 Sept 2020
19 Oct 2020
18 Sept 2020
16 Oct 2020
2 Oct 2020
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, Hard/dense soil., etc complete all as specified and directed.
Excavation over areas n exc. 1.5m deep and getting out in any type of soil complete all as specified and directed.
Excavation over areas exc. 1.5m but n. exc. 3.0m deep and getting out in any type of soil complete all as specified and directed
Excavating in trenches in any type of soil , n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Removing excavated surplus soils material and not exc 250 m depositing where directed at a level n exc. 1.5 m above the starting point all as directed
Material and labour for Hard core of broken stone or boulders gauge n exc 63mm deposited and spread and levelled in layers n exc 15cm thick watered and rammed to a true surfaces complete all as specified.
Material and labour for 100 mm thick PCC 1:3:6 Type C2 using 40mm graded stone aggregate in cement concrete in sub floor, sub bases floors and paving complete all as specified.
Material and labour 75 mm thick PCC 1:3:6 Type C1 (using 20mm graded aggregate) as in floor/path /plinth protection etc.
Material and labour for PCC 1:4:8 Type D2 using 40mm graded stone aggregate in foundation and filling and mass concrete etc complete all as specified.
Material and labour PCC 1:3:6 Type C2 (40 mm graded aggregate) in foundation filling and mass concrete complete all as specified and directed
Material and labour for PCC 1:2:4 Type B1 (20 mm graded aggregate) as in coping surface channels, benching etc of manholes finished fair and even complete all as specified and directed.
Extra for forming fair finished channel or drain 30cm girth (inner girth) in cement concrete using extra cement incl forms, moulds stopped complete all as specified and directed.
Material and labour for PCC 1:3:6 Type C 1 (using20 mm graded aggregate, Providing, precast cement concrete in manholes cover, window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar including all form work complete with joints to match
Material and labour for pre-cast cement concrete block PCC 1:3:6 Type C1(20mm graded stone aggregate) masonry with solid block exc 10cm in width and setting in CM 1:6 complete all as specified and directed.
Material and labour for pre-cast cement concrete block PCC 1:3:6 Type C1(20mm graded stone aggregate) masonry with solid block exc 10cm in width and setting in CM 1:4 complete all as specified and directed.
Material and labour for precast cement concrete solid block masonry with solid blocks using PCC 1:3:6 Type C1 using 20mm graded stone aggregate n.exc 10cm in width and setting in cement mortar (1:4) etc complete all as specified.
Use and waste for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat for rough finished surface of concrete
Use and waste for form work rough finished surfaces of square or rectangular pillars, posts, sruts, piers, columns and stanchions.
Use and waste for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams flat for rough finished surface of concrete etc complete.
Material and labour for RCC M 30 (design mix) for foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass conc.
Material and labour for RCC M30 (design mix) for columns, pillars, piers, posts and struts complete all as specified and directed
Material and labour for RCC M 30 (design mix) for beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed
Material and labour for Reinforced cement concrete M30 (design mix)as in shelves/Chhajas and the like complete all as specified.
Material and labour for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Material and labour for TMT steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Taking down cement plaster any description incl racking out joints, hacking for key scrubbing down with water, etc complete all as specified and directed
Material and labour for 15mm thick external rendering in two layers of 5mm thick in CM (1:4) mixed with water proofing compound (water proofing compound shall be @3% weight of cement) over and including a coat of 10mm thick in CM (1:6) over brick or concrete surfaces finished even and fair. Note: Supply only WPC will be measured and paid separately
Material and labour for Rendering 10mm thick in CM 1:6 on internal surfaces of brick work or concrete surfaces of walls, finished even and smooth ( without using extra cement) complete all as specified.
Supply only water proofing compound conforming to IS-2645 1975 complete all as specified and directed.
Material and labour for two coats of oil bound distempering to new plastered wall surfaces over a coat of primer incl preparation of surfaces complete all as specified and directed
Material and labour for applying two coats of cement base paint over a coat of primer on new plaster or untreated surfaces on walls incl preparation of wall surfaces complete all as specified and directed
Material and labour for two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer incl preparation of new or previously untreated steel surfaces of any description over 10cm width or girth complete all as specified and directed.
Material and labour for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.
Material and labour for two coat of weather proof exterior acrylic emulsion paint with anti-fungal property over a coat of primer on newly plastered wall surfaces including preparation of surfaces etc complete all as specified and as directed by Engineer-in-Charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises complete all as specified and directed.
Material and labour for coloured non-skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11 sqm n.exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with coloured cement to match the colour of tiles over and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
All as per item No 38 here in before, but on vertical surfaces incl 10mm thick CM 1:3 as in baking coat of dado/skirting
Material and labour non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm and not exceeding 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15mm thick screed bed in CM 1:6 complete all as specified and directed
Material and labour for Chequrred cement concrete tiles with grey cement and pigment of size 300x300x25 mm, set jointed and pointed in neat cement slurry over 15 mm thick screed in CM (1:6) complete all as specified and directed.
Supply and fix MS steel work in tubular /post/trusses/purlin including special shaped washers base and bed plate cleat nut and bolt etc., complete using but welded tubes confirming to IS 1161- 1979 graded St 240 complete all as specified and directed
Supply and fix Mild steel bolts exc 12mm n' exc 20mm dia , purpose made, with hexagonal or square head one end and screwed the other, or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long complete all as specified and directed
Supply and fix Plates plain channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 410-W(Gde E-250) quality B complete all as specified and directed.
Supply and fix for mild steel flat iron as wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directe
Dismantling for plain or corrugated roof sheeting of any description, any gauge, thickness, including Removing L-type or J-type bolts in Roof Covering complete all as specified and directed.
Supply and fix prepainted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/clading to wall fixed with self-tapping screws all as specified and directed.
Supply and fix prepainted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thgick of any colour having tensile strength of 550Mpa as in ridges, roof covering/clading to wall fixed with self-tapping screws all as specified and directed.
Supply and fix 2nd class Hard wood 15mm thick plain both side as in eaves board etc. complete all as specified and directed
S & F aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/ partition frames and shutters (glazed / gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, all as specified in relevant IS code and SSR Part-I and complete all as specified and as directed by engineer- in- charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- i)Weight of various Aluminium sections and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing, glazing clips, neoprene packing, fittings such as handles, butt hinges, tower bolts given in the item shall deemed to be included in the rate quoted. ii)Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only). (iii) Weight of aluminium handles, butt hinges & tower bolts shall not be accounted for payment purpose ]
Supply only 4 mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares not exceeding 0.50 sqm in each pane complete all as specified and as directed.
Supply only 4 mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed by Engineer-in-Charge.
Supply only 12mm thick pre-laminated particle board, exterior grade, lamination on one side with decorative choice lamination and the other side balancing white lamination fixed with screws as in door panel, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 4 mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed.
Supply and fix Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips of sheet cast or extruded sections and fixing bolt or cast aluminium alloy& fixed complete all as specified and directed.
Supply only aluminium anodised fly proof mesh 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium straps complete all as specified and directed.
Supply only 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on one side with decorative choice lamination and other side white lamination fixed to Aluminium frame etc all as specified and directed by Engineer-in-Charge .
Supply and fix solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed by Engineer-in-Charge.
Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC `C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame complete all as specified and directed by Engineer-in-Charge.
Supply and fix 150mm long extruded, aluminium alloy, anodised, handles, fabricated type, complete all as specified and as directed by Engr-in-Charge.
Supply and fix Butt hinges, of size 100 mm length extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 complete all as specified and directed
Supply and fix Aluminium anodised barrel tower bolt of extruded section of size 150 mm long complete all as specified and directed
Material and labour for false ceiling with aluminium grid work (Size of grid 600x600 mm) with 35 x 25 x 1.5 mm main tee and 25 x 25 x 1.4 mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof with needful adjustment bolts at an interval of 1.20 m centre to centre staggered and board with Eco board decorative type size 600 x 600 x 4 mm thick finished with two coats of oil bound distemper over a coat of primer on exposed surfaces complete including Dismantling of old ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness all as specified and directed by Engineer-in-Charge.
Material and labour for 20 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe all as specified and as directed.
Material and labour for 15 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe all as specified and as directed.
Supply and fix vitreous china wash basin white flat back size 550 x 400 mm including 15 mm dia fancy type pillar tap chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32 mm dia of required length and all necessary 450 mm long outlet and inlet PVC connections pipe with PTMT check nuts complete.
Supply and fix vitreous china half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around back in cement discharge pipe etc complete all as specified and as directed by Engr- In -Charge.
Supply and fix vitreous china squatting pan Orissa pattern of size 580x440mm white with integral foot rest and including 10 Ltr capacity low level flushing cistern with flexible pipe and necessary PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Supply and fix brass chromium plated tubular towel rail 20 mm dia, D type 60 cm long between flanges Towel rail brass chromium plated 60 cm complete all as specified and directed
Supply and fix PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed
Supply and fix stop valves 15 mm chromium plated fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed Stop valve CP 15mm complete all as specified and directed
Supply and fix 110mm bore of PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed
Supply and fix PVC (SWR) 75mm bore piipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
Supply and fix 110 mm bore PVC (SWR)bend any radius
Supply and fix 75 mm bore PVC (SWR)bend any radius
Material and labour for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed
Supply and fix Rotational moulded polyethylene water storage tanks of capacity 500 Ltr (cylindrical vertical with closed top) with 20mm dia float valve , hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed
Material and labour for PCC 1:3:6 type C2 as in bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested for CI pipe 150 mm bore complete all as specified and directed.
Material and labour for 150mm dia CI pipe (sand cast) in any length with (or) without ear laid in trenches and jointed in CM 1:1 complete all as specified and directed.
Taking down carefully, copper/aluminium point wiring (Light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
Material and labour Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc. One light point controlled by one way switch all as specified and as directed.
All as per item No 82 here in before but One 3 pin switch socket outlet point 5 amps on independent board.
All as per item No 82 here in before but One fan point controlled by one switch with one regulator.
All as per item No 82 here in before but One 3 pin switch socket outlet point 5 amps on same board.
All as per item No 82 here in before but One 3 pin switch socket outlet point 5 amps on independent board.
All as per Item No 82 here in before but for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4Sqmm copper conductor cable and earth continuity conductor, complete all as specified and as directed
Supply and fix switch piano flush type single pole one way 5 Amp all as specified and directed.
Supply and fix switch socket outlet 3 & 2 pin (multi pin) 5 amps flush/box type, complete all as specified and as directed by Engineer-in-Charge
Supply and fix switch socket multipurpose 3pin 15 and 5 amp controlled by one switch flush type, complete all as specified and as directed by Engineer-in-Charge
Supply and fix ceiling rose surface Bakelite 65 x 50 mm 3 terminal, complete all as specified and as directed by Engineer-in-Charge
Supply and fixing energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core sheathed cable from fitting to ceiling rose all as specified and as directed. Make : Philips Cat No BN021C LED20S PSU CDL/NW GR or eqvt in make of Bajaj/Wipro.
Supply and fix New genration energy saving & envoirmental friendly security light 25 Watt, long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed. Make: PhilipsCat No BRP020 LED HP CW 240V or equivalent model of Wipro / Bajaj
Supply and fix Wall mounting fan Sameera, electric driven single phase230 volts, oscillating type, 400 mm sweep, high quality ABS base with high speed motor and balanced blades and three leafed with 3 core copper cable of suitable size, complete all as per specified. Make Havells HSN code 8414 or eqvt in make of Bajaj/Wipro.
Supply and fix exhaust fan suitabe on working of 230V AC, 50Hz, 300mm sweep, 1400rpm, with heavy duty motor, incuding louvers complete all as specified and as directed by Engineer-in-Charge.
Supply & fix ceiling fan suitable for working on AC 230 volts, 50 Hz, 1200 mm sweep 5 star rating with down rod and canopy colour of milky white including suitable fan hook anchor flashner for fixing of fan on ceiling complete all as specified and as directed
Supply and fix Wall mounting fan Swing, electric driven single phase230 volts, oscillating type, 300 mm sweep, high quality ABS base with high speed motor and balanced blades and three leafed with 3 core copper cable of suitable size, complete all as per specified. Make Havells HSN code 8414 or eqvt in make of Bajaj/Wipro.
Supply and fix metal enclosure distribution board SPN, 4 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed by Engineer-in-Charge Make :Legrand/C&S/L&T Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix in repair MCB single pole 240 volts, 0.5 to 32 amps complete all as specified and as directed by Engineer-in-Charge Make : Legrand/C&S/L&T
Supply and fix in repair MCB SPN, 240 volts, 6 to 32 amps C series complete all as specified and as directed by Engineer-in-Charge Make : Legrand/C&S/L&T
Supply and installing JEF Electrical grounding system comprises of Electrode CU coated steel rods 17.2mmx3000mm (250M) UL Loresco Power fill carbon based backfill compound 2 bags of 50 pounds 17.2/OD SS clamp both side ECO friendly rust proof heavy duty weather proof Polyethylene earth pit chamber with following dimensions : 254 mm dia(top), 330mm dia (bottam) & 260mm (height) of part No R28.F03.SS02.CB1.
Material and labour copper strip 20x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground.
Material and labour Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
Supply and fix Singe pointed air termination copper rod 12mm dia and 300 mm long, fixed on overhead reservoirs for lightening protection with necessary connections to earthing etc complete all as specified and as directed.
Supply, install, testing and commissioning of CPRI approved outdoor type LT feeder pillar box powder coated suitable for 415V, 3 Phase, 4 wire system, 50Hz, AC supply system, double door, totally enclosed dust & weather/vermin proof made out of 3mm thick CRCA outer sheet and 2mm inner sheet duly powder coated of suitable size with degree of protection IP 54, floor mounted free standing type,having opening and locking arrangement of front side and shall be mounted on 4 Nos angle iron 50 x 50 x 6mm fixed with nuts-bolts of suitable size duly painted with two coats of synthetic enamel paint over one coat of red oxide primer, 60CM long, 30CM embedded in PCC 1:3:6 type C-2 suitable for mounting following switchgear and accessories in the panel complete all as directed. (a) MCB 32A TPN C Series 10 KA - 1 No Incomer (b) MCB TPN 25A, C series, 10KA - 2 Nos (Outgoing+ Spare) (c) MCB DP 16A, 10KA - 1 Nos Outgoing (d) Phase indicating lamp -01 Set
(e) Bus Bar: 50 Amps TPN bus bars of aluminium alloy. (f) VAF Meter - 01 No, CT -Set of 3 and necessary control wiring Note: Rate is deemed to be inclusive of following:- (a) Danger notice plate having conventional symbol of skull and bone. (b) Locking arrangements of door. (c) Bottom of the panel shall have detachable plate having provision for entry of armoured cable of adequate size with glands. (d) Shall have provision of earthing connection at bottom and lifting lugs on top to lift the pillar box
Supply, Laying in trenches LT underground cable of size 3.5 Core 50 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed.
Supply, Laying in trenches LT underground cable of size 4 Core 16 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed.
Supply, Laying in trenches LT underground cable of size 2 Core 10 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed.
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including spreading, punning down and consolidation complete all as specified and directed. Note : Punned thickness shall be measured for payment
Supply and laying unreinforced Precast Cement Concrete Cable covers, class LV, type-1, flat, size 250 mm X 150 mm X 40 mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and as directed.
Material and labour GI pipe light grade of size 50mm with all fittings complete laid in trenches all as specified and as directed by Engineer in Charge.
Material and labour GI pipe light grade of size 40mm with all fittings complete laid in trenches all as in repairs as specified
Supply and lay HDPE double wall corrugated pipes confirming to IS-14930 Part II for cable protection of size 50mm OD and 38mm ID including all accessories such as bend, end caps and couplers etc,, complete incl taking down old DWC pipes all as specified and as directed by Engineer-in-Charge. Make : Gemini/ Tele-rex.
Supply, install, testing and commissioning of junction boxes, weather/vermin proof made out of 3mm thick CRCA sheet (CPRI approved) duly powder coated of size 60cmX 60cm x 20cm(depth) having opening and locking arrangement of front side, floor mounted free standing type, aluminium bus bar 50 Amps current carrying capacity for 3 Nos phase & neutral with colour coded heat shrinkable insulated sleeves and insulated support, mounting the junction box shall be mounted on 4 Nos angle iron 50 x 50 x 6mm fixed with nuts-bolts of suitable size duly painted with two coats of synthetic enamel paint over one coat of red oxide primer, 40CM long, 30CM embedded in PCC 1:3:6 type C-2 with PCC (1:3:6) type C1, bedding upto height of 30cm above ground level and suitable for electrically connected with any size of incoming/ outgoing cables feeder piller box complete all as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of size 25 x 4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to and including earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, 20mm GI pipe for watering and funnel, GI Pipe medium grade 40 mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 all as directed by Engineer in Charge
Supplying, installation, testing and commissioning of 6m high hot dip galvanized iron octogonal pole 3.0mm wall thickness, with bottom size 130 mm diameter, top size 70mm diameter with 3mm thick base plate of size 220x220x12 mm, pole fabricating out of medium grade tapered pole octagonal cross section and shall be continuosly tapered with single longitudinal conforming to BSEN 100 25/100 27 with base plate Fe 410 conforming to IS 2062 of suitable thickness with provision of 4 Nos foundation bolts. The pole shall be galvanized as per IS 4759/BSEN1461 standards/housing with 4way 16A connector for loop in and out of cable and 6A MCB SP inside inbuilt junction box, complete end termination, including single luminary arm 42mm diameter, 2.6mm thick, 1m long, with grouting of base plate in concrete foundation 1:2:4 using 20mm aggregate concrete including excavation, earth work, returing filling etc. (All poles should be prewired from Junction box to fixture with 2.5 Sqmm size of wires for Phase, neutral and Earth and provision for mounting fitting on pole).
Note:(i) Quoted rate are deemed to include Earth work and excavation, necessary foundation i.e reinforcement, holding down bolts, nuts, washer of suitable size concrete etc complete pole as per manufactures instruction and standards and necessary accessories for mounting light fittings on pole. (ii) Light fitting will be measured and paid separately. MAKE : Bansal/Bajaj/CG
Supply and fix Street light fitting of 36W made up of pressure die cast housing with toughened glass and high power LEDs, IP65 class of protection and suitable for 230V, 50 Hz AC supply all as directed and as specified by Engineer-in-Charge. Make: Philips Cat Part no BRP052 LED 036 CW HP SLA FG S1 PSU GR or Crompton cat Part No LSTS-36-CDL-M
Supply and fix Street light timer panel 3 phase of maximum load 6 KW with timer switch, contactor rating 40A /TP, MCB rating 40A all as directed and as specified by Engineer-in-Charge
Cutting Hard standing/bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with the existing surfaces using cement concrete 1:2:4 B1 or tar complete all as specified and as directed by Engineer-in-charge.
B S Grewal
T.THIYAGARAJAN
Hindustan Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .