| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.5 L+₹1.5 L (15.5%)Rejected-Finance MCB Z 5 04939 GURU GOBIND NAGAR BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹11.9 L+₹1.9 L (19.3%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹18.6 L+₹8.7 L (87.1%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹20.1 L+₹10.1 L (101.8%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sachin H Chavan IDSE
GE NORTH BATHINDA MIL STN-151004
REPAIR CLEANING OF SEWAGE LINE IN OTM ACCN UNDER ZONE A AND M UNDER AGE BR-V OF GE NORTH BATHINDA AT BATHINDA MIL STN
2021_MES_450739_1
8936/NIT-22/21-22
Open Tender
Civil Works
Item Rate
330 days
GE NORTH BATHINDA MIL STN
E Class and category a ii
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹50,000
Yes
13 Jul 2021
11 Jun 2021
10 Jul 2021
11 Jun 2021
8 Jul 2021
26 Jun 2021
11 Jun 2021 - 18 Jun 2021
60 days
Amount
SCHEDULE 'A' B/R Works
Material and labour for Cleaning/removal of blockage from bathroom, kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning/removal of blockage from EWC/IWC (any type) including connected traps (any type), pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole not exceeding 15mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole exceeding 15 mtr but not exceeding 30 mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole exceeding 30 mtr ) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed by Engineer-in-Charge.
Note for item No 01 to 05
Contractor must employ Minimum Six nos labourer's daily i.e. 02 Nos for Manoj Pandey Enclave , 02 Nos for Gurnaam Singh Enclave and 02 Nos for Joginder Singh Enclave.
Contractor or his representative shall report daily at 09.00 AM except on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge.
In case of non attaedence of complaints against BOQ item 01 and 02 above by the contractor on the same day, a penalty of Rs 200/- per complaint per day and for complaints against BOQ item 03 to 05 above, a penalty of Rs 100/- per complaint per day will be recovered from the contractor due.
The cost for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc and all other other materials for execution of the work shall be included in the unit rate.
A complaint register shall be maintained by JE and proper record of complaints received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engineer-in-Charge after completion of work.
Excavation in trenches in soft / loose soil not exceeding 1.5 meter wide & not exceeding 1.5 meter in depth for foundations of manholes, sewerage pipe lines etc including getting out complete all as specified and as directed by Engineer-in-Charge .
Demolition and breaking up drain pipes SGSW,AC or reinforced concrete pipe up to and incl 150 mm bore pipes all as specified and directed by Engineer-in-Charge.
Material & labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate to drain pipe incl packing under & hunching against the sides of pipe 150 mm dia (internal) after they are laid and tested in trenches complete all as specified.
M&L 150 mm dia ( internal) SGSW pipes grade ‘A’ laid in trenches & jointed complete all as specified and as directed by Engineer-in-Charge .
Demolition of brick work built in cement mortar including all quoins, pillars etc., but excluding pre-cast cement concrete articles complete all as specified and as directed by Engineer-in-Charge .
M&L Brick work with sub class ‘B’ bricks old size straight or curved on plan exceeding 6 meter mean radius built in CM 1:4 complete all as specified and as directed by Engineer-in-Charge .
Demolition of cement concrete of any description in ground floor in any position not exceeding 15 cm thickness complete all as specified and as directed by Engineer-in-Charge .
Material & labour for cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate for foundations, fillings & mass concrete complete all as specified and as directed by Engineer-in-charge.
Material & labour for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for manhole benching and coping complete all as specified and as directed by Engineer-in-charge.
Material & labour for 15 mm thick cement plaster in CM 1: 4 on fair / unfair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for 10 mm thick cement plaster in CM (1:4) on fair/unfair faces of bricks work or concrete surfaces finished even and smooth without using extra cement including mixing of WPC in mortar @ 3% of cement content complete all as specified and as directed by the Engineer-in-Charge.
Material & labour pre-cast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in pre-cast manhole cover slabs of any thickness, size or shape including all necessary form work , finishing concrete surface fair & even and set in CM 1:4 all as specified and directed by Engineer-in-Charge.
Supply & laying in position TMT bars of 6 mm to 8mm dia in reinforcement, cut to length, bend to shape required including cranking, bending, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and as directed by Engineer-in-Charge.
S&F mild steel work in rungs, hooks, handels, manhole covers, hold fast & small articles all as specified
Returning/filling in including spreading, leveling , watering & well ramming in layers not exceeding 25 cm thick each all as specified and as directed by Engineer-in-Charge.
Removal of excavated material to distance not exceeding 1.5 meter above the starting point complete all as specified and as directed by Engineer-in-Charge .
Supply only integral water proofing powder ISI make complete all as specified and directed by Engineer-in Charge.
S&F in repair CI cover suitable for 75mm dia CI bend/Tee etc fixed with bolt and gasket complete all as specified and directed by Engineer-inCharge.
S&F in repair CI cover suitable for 100mm dia CI Bend/Tee etc fixed with bolt and gasket complete all as specified and directed by Engineer-in-Charge.
Dismantling and disconecting of existing cast iron soil vent pipe fixed to wall laid in trenches incl all fitting & accessories as directed by Eng-in-charge.
S & F 100 mm dia cast iron soil waste and vent pipes (sand cast) in any length with or without laid in floor with cement joints.
S & F 100 mm dia cast iron soil waste and vent pipes (sand cast) in any length fixed to wall with cement joints incl S & F Stack clamps of 50mm x 5mm flat iron & 16mm dia round iron stays, incl nuts & bolts & securing ends of stays to wall & roof.
S & F 75 mm dia cast iron soil waste and vent pipes( sand cast) in any length with or without laid in floor with cement joints.
All as per item No 28 here in before but fixed to walls incl S & F Stack clamps 50mm x 5mm flat iron & 16mm dia round iron stays, incl nuts & bolts & securing ends of stays to wall & roof.
S & F 100 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured).
All as per item No 30 here in before but with oval access door.
S & F CI cowl in repairs 100mm bore fixed with cement joint in cement mortor 1:2 complete all as specified and directed.
S & F CI branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches of 100 mm with oval access door bore complete all as specified and directed.
S & F 75 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured).
All as per item No 34 here in before but with oval access door.
S & F CI cowl 75mm bore fixed with cement joint in cement mortor 1:2 complete all as specified and directed.
S & F CI branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches of 75 mm with oval access door bore complete all as specified and directed.
S&F in repair cast iron floor trap, 75 mm outlet dia, with grating including jointing to waste pipe fixed in cement concrete type B -1, 1:2:4 complete all as specified.
S & F 75 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured).
All as per item No 39 here in before but with oval access door.
S&F in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) size of cover 0.70 x 0.70 conferming to IS 12592, fixed in cement cocrete 1:2:4. complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exc 0.11 sqm in floors etc.set jointed in neat cement slurry and pointed in white or coloured cement to match over & incl 15 mm thick screed bed built in CM 1:6 all as specified
M&L for glazed ceramic coloured tiles on vertical surfaces 450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl 10 mm thick screed plaster built in CM 1:4
S &F in RepairsVitreous china Squatting pan of pattern ,"orissa pattern", size 580x440 mm white ,with integral foot rests (excluding flushing cistern and flush pipe)
Supply & Fixed in repairs vitreous china Wash down water closet (pestel pattern) EWC with s and p trap including connection to drain ( or outgoing pipe ) and to flush pipe including seat cover complete
S&F PVC flushing cistern, low level, 10 ltr capacity, white, with inlet , ball valve, float valve and handle including brackets, pvc flushing pipe 32 mm dia (white) and pvc connection complete all as specified
Cleaning & De-sludging by removing semi solid sludge from the septic tank of any capacity at any depth manually or mechanically in foul condition including all necessary tools and plants required for removal of sludge and solid contents from the site all as specified and directed by Engineer-in-charge. Note:- The sludge obtained after de-sludging is contractors property as credit schedule.contractor should remove the sludge out side defence land immediately without any extra cost from the MoD land.
Dewatering the existing soakage well/septic tank by bailing out /pumping out or by any other means and depositing the same off into existing open drain /surrounding low lying area nearby all as specified and directed by Engineer-in-charge.
Cleaning & De-sludging by removing semi solid sludge from the septic tank/Soakage wells/Manholes of any capacity at any depth by mechanically truck mounted hydro jet sewage line cleaning machine of sewage line water sludge tank with wash down system/suck derrick arm hydraulically spring loaded rotary sliding vane compressor with V hose end section No. 33 nozzle and strainer all as specified and as directed by Engr-in-charge. Note:- (a) Copy of vehicle in and out duly defaced by Engineer-in-charge shall be produced during making of payment. (b) The quoted rates include removing and refixing of Manhole covers.
M/s GURFATEH BUILDERS
V K CONTRACTOR
R K GOYAL & COMPANY
ABHINANDAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .