| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC SINCE LOWEST BIDDER | |
| 2 | L2₹38.8 L+₹4.3 L (12.6%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 3 | L3₹42.0 L+₹7.5 L (21.9%)Rejected-Finance | L3 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 4 | L4₹45.1 L+₹10.7 L (30.9%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L4 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 5 | L5₹45.4 L+₹10.9 L (31.6%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance SINCE NOT L1 BIDDER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 Aug 2023, 6:00 pmClosed
CWE AMRITSAR CANTT
HQ CWE AMRITSAR OLD CANTT
SPECIAL REPAIR OF 07 NOS VCB AGAINST BER AND ALLIED WORKS AT NAMS
2023_MES_608290_1
CWE/ASR-19/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NAMS
₹96,000
Yes
22 Sept 2023
7 Jul 2023
9 Aug 2023
7 Jul 2023
2 Aug 2023
21 Jul 2023
Amount
Supply, installation, testing and commissioning of Scada Compatible indoor type vacuum circuit breaker of 07 panel Switchboard (1 incomer & 6 Outgoings) shall be of floor mounting, sheet steel clad, free standing, and dust & vermin proof, compartmentalized type VCB switchboard with posibility of future extension at both side. The MS sheet 2mm thickness must be as per tested design of manufacturer. The switchboard shall be suitable for 12 kV, 3 Ph., 3 W, 50 Hz , AC system and complete with VCB, air insulated Copper Bus bar rated for 1250A for 12kV switchboard and suitable for a short circuit capacity of 26.3 kA for 3 Sec. Switchgear should be as per latest IEC 62271 (62271-1, 62271-100, 62271-200). All the compartments of the panel should be segregated from each other by means of earthed metallic sheet steel. The shutters which should be provided for Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement safety purpose must also be of earthed metallic sheet steel only. The shutter mechanism should be coupled with the movement of the withdraw-able truck. Except the busbar compartment, all the compartments of each cubicle should be independent from the similar compartment of the adjacent panels. The busbar compartment should run from end to end without any inter-panel barriers soas in the event of internal arc inside the bus bar compartment, the arc will travel along the length of the switchboard. The switchboard shall be painted with light grey, shade no. RAL 7032, both inside and outside with IP-4X ingress protection. Inbuilt Anti-pumping Feature. VB should be Energy management Solution enabeled . 1. EMS software should have inbuilt E-mail & SMS trigger functions. 2. EMS software must have a separate screen with minimum of 10 Analog Gauges for parameters viewing. 3. EMS Dashboard must have provision to show daily as well as monthly comparative energy consumption. 4. Must be able to generate Electricity bills directly from software. True Close Door Operation as per IEC. Individual Shutter Assy for Bus Bar Side & Cable Side. By Default Test / Service Indication. Spout with Copper Terminal .Make of VCB :- Siemens / L&T/Alstom/ Areva/ Crompton & all other equivalent makes as specified. Incommer - 1 no
Supply ,installation,testing,Commissoning of indoor extension 11kV adaptor panel with Copper bus of 1200A for us extension and suitable connection to above panel.Adaptor panel shall be manufactured by OEM company as per site requirement to match existing VCB.B71 complete all as specified and directed. Note for Srl No 1 and 2 :- Each VCB complete control Fuses/MCB's, Panel illumination Lamp, Plug & Socket, Thermostate, Panel Space heater assembly, Emergency Push Button, wiring and fabrication are included in unit quoted rates of the Contractor No extaa any have been paid to the Contractor.Only OEM is authorised to supply the eqpt at site,No subletting to any firm/company will be acceptable.
M&L for earthing complete with Copper earth plate electrode 60x60cmx3.15 mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to copper strip of size 20x3 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 20 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
S&F for copper strip of size 20x3 mm from test point to transformer or other places complete all as specified and directed.
Material and labour for end termination jointing kit cold shrinkable Outdoor type ,suitable for HT 11000 volts grade cable of size 120 to 185 sqmm 3 core complete all as specified.
Material and labour for end termination jointing kit cold shrinkable Indoor type , suitable for HT 11000 volts grade cable of size 120 to 185 sqmm 3 core complete all as specified.
RAVI KUMAR
dinesh enterprises
HARPAL ENGINEERS AND BUILDERS
kailu construction co
Raman Electric Trading Co
GULSHAN SINGH GHAI AND SON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .