Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹40.5 L+₹4.6 L (12.7%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹49.8 L+₹13.9 L (38.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/s Rahat Traders L3 | M/S KALSI ENGINEERS AND CONTRACTORS L2 | narayan construction L1 |
|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE-A PART-I (B/R WORKS) Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed. | 2 | Cum | 50 ₹100 Lowest | 200 ₹400 | 100 ₹200 |
| 2.00 | Material & Labour Brick work with sub class 'B' bricks built in CM 1:6 straight or curved on plan exc 6 m mean radius complete all as specified and directed.. | 2 | Cum | 4,000 ₹8,000 Lowest | 5,000 ₹10,000 | 6,000 ₹12,000 |
| 3.00 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. | 190 | Sqm | 30 ₹5,700 | 10 ₹1,900 | 2 ₹380 Lowest |
| 4.00 | Rendering 10 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 compound finished even and smooth without using extra cement complete all as specified and as directed. | 140 | Sqm | 222 ₹31,080 | 150 ₹21,000 Lowest | 200 ₹28,000 |
| 5.00 | M & L for rendering 15mm thick in two layer (10mm+5mm) in cement mortar 1:4 on fair faces of brick work / concrete surfaces finished even and smooth with out extra cement with WPC complete all as specified and as directed by the Engineer-in-Charge
Note:- (i) water proofing compound on only top layer of plaster (ie 5mm thick)
(ii) Qty of WPC 200ml per cement bag as per manufacturer instructions
(iii) WPC shall be measured and paid separately) | 120 | Sqm | 150 ₹18,000 Lowest | 150 ₹18,000 Lowest | 200 ₹24,000 |
| 6.00 | Supply only liquid water proofing compound complete all as specified and directed | 2.5 | Ltr | 20 ₹50 Lowest | 50 ₹125 | 100 ₹250 |
| 7.00 | Material & Labour Preparation of newly plastered wall surfaces and applying two coats of distemper oil emulsion over one coat of birla white putty 2-3 mm thick preparatory to distempering complete all as specified and directed. | 140 | Sqm | 111 ₹15,540 | 100 ₹14,000 | 80 ₹11,200 Lowest |
| 8.00 | Material & Labour for priming new surface of wall with alkal iresistant priming paint of and applying two coats of cement base paint complete all as specified and directed. | 120 | Sqm | 80 ₹9,600 | 80 ₹9,600 | 35 ₹4,200 Lowest |
| 9.00 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.. | 130 | Sqm | 20 ₹2,600 | 20 ₹2,600 | 10 ₹1,300 Lowest |
| 10.00 | Material & Labour Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. | 115 | Sqm | 1,200 ₹1,38,000 | 900 ₹1,03,500 | 750 ₹86,250 Lowest |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
30 Jul 2025, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR DESILTING CLEANING MANHOLES SEPTICTANKS MAINTENANCE OF FAN GEYSER DESERT COOLER AIR CONDITIONER WATERCOOLER REPAIR TO GEN SET AND COMPREHENSIVE MAINTENANCE AT VARIOUS LOCATIONS MANHORE GOOL BAGGA KALAL KALAKOTE SAMOTE BUDHALETC UNDER AGE REASI
2025_MES_718058_1
CANO GEN-56/2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE NAGROTA
Class D Cat a(i) b(i)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹99,800
Yes
9 Oct 2025
2 Jul 2025
6 Aug 2025
2 Jul 2025
30 Jul 2025
16 Jul 2025
Amount
SCHEDULE-A PART-I (B/R WORKS) Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
Material & Labour Brick work with sub class 'B' bricks built in CM 1:6 straight or curved on plan exc 6 m mean radius complete all as specified and directed..
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
Rendering 10 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 compound finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 15mm thick in two layer (10mm+5mm) in cement mortar 1:4 on fair faces of brick work / concrete surfaces finished even and smooth with out extra cement with WPC complete all as specified and as directed by the Engineer-in-Charge Note:- (i) water proofing compound on only top layer of plaster (ie 5mm thick) (ii) Qty of WPC 200ml per cement bag as per manufacturer instructions (iii) WPC shall be measured and paid separately)
Supply only liquid water proofing compound complete all as specified and directed
Material & Labour Preparation of newly plastered wall surfaces and applying two coats of distemper oil emulsion over one coat of birla white putty 2-3 mm thick preparatory to distempering complete all as specified and directed.
Material & Labour for priming new surface of wall with alkal iresistant priming paint of and applying two coats of cement base paint complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed..
Material & Labour Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply & Fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets/AC boards etc any thickness . complete all as specified and directed.
Supply & Fix Anodised aluminium snap grid frame work for false ceiling all as specified. (Size of grid 605 X 605 mm) complete all as specified and directed.
Supply & Fix 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws.) fixed in ciiling surface complete all as specified and directed
Supply & Fix 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. complete all as specified and directed.
Supply & Fix Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as spd and directed.
Taking down Chowkats or frames n. exceeding 1.5 Sqm each (Without taking off shutters from the frame). complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4.00 Sqm each (Without taking off shutters from the frame). complete all as specified and directed.
Taking down Shutter exceeding 1.0 Sqm but not exceeding 2.00 Sqm each. complete all as specified and directed.
Taking down Shutter exceeding 2.0 Sqm each. complete all as specified and directed.
Supply & Fix Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs,hinges, lock strike plate, hinges etc complete, size of frame 125x60mm including tarring ends and back of chowkats and lugs including back filling of PCC 1:3:6 for chowkats & PCC 1:2:4 for block for hold fast including two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces all as specified and directed.
Supply & Fix 35 mm thick 2nd class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply & Fix 35mm thick, 2nd class hard wood glazed and skelton shutter, open rebated and prepare to receive glass, gauzed etc(without sash bars) edges of framming plain , chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR PART I Section 8 clause 8.24(a) supplied and fitted to chowkhat complete all as specified and directed.
Supply & Fix 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commerial type of one side and another face is covered with aluminium sheet, 0.5mm thick, fixed with aluminium alloys screws complete all as specified and directed.
Material & Labour preparation of new wooden surfaces over10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer complete all as specified and directed.
Supply & Fix Steel windows/ventilator with tubular frame factory made with double shutter (wire gauged shutter & glass/glazed shutter, (wire cloth and glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete, two coats of synthetic enamel paint over one coat of red oxide primer including taking down old windows/ventilators all as specified & as shown on drg .CEUZ/TD/1269/2008 SHT 1/1 to 1/3.
Supply and Fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as perspecification & drawing complete all as specified and directed.
Supply and Fix Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2,4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing including all fittings complete all as specified and directed (
Supply & Fix Floor door stopper of aluminium alloy body and tongue,anodised, with hard drawn steel spring, fixed in floor Door Stopper 140 mm complete all as specified and directed
Supply & Fix Galvanised mild steel wire cloth,0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Supply & Fix Powder coated Anodised aluminium frame(Thickness of powder coating not less than 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed
Supply & Fix Powder coated Anodised aluminium door shutters,aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, mortice lock,screws etc. complete all as specified and directed.
Supply & Fix Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sectionsweighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified complete all as specified and directed
Supply & Fix Aluminium anodised handle extruded section of size 150mm complete all as specified and directed.
Supply & Fix Aluminium anodised handle extruded section of size 125mm complete all as specified and directed.
Supply & Fix 100 mm butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
Supply & Fix Aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed.
Supply & Fix Aluminium anodised barrel tower bolts extruded section of size 200 mm, all as specified and directed
Supply & Fix Aluminium anodised barrel tower bolts extruded section of size150 mm, all as complete all as specified and directed
Supply & Fix Aluminium anodised handle extruded section of size 100mm complete all as specified and directed.
Supply & Fix 75 mm butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
Supply & Fix Aluminium alloy, anodised, sliding door bolt of length 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed.
Supply & Fix Aluminium anodised barrel tower bolts extruded section of size 125 mm, all as specified and directed
Supply & Fix Aluminium anodised barrel tower bolts extruded section of size100 mm, all as complete all as specified and directed.
Supply & Fix 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
Supply & Fix 5.5mm thick plain sheet glass as in window and door shutters with and including rubber gasket and natural colour anodized 15micron snap on aluminium beading/glazing, clips etc complete all as specified and directed.
Supply & Fix Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as spd and direcetd.
Securing glass of any description in existing glass in metal frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work (New length of frame reputtied shall be Measured ) complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/ steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
Supply & Fix 3 mm thick sheet glass pin headed quality and glazing with oil putty or fixed with bead/glazing pins in squares any size in each pane all as specified and directed.
Supply & Fix sheet glass ordinary quality 3 mm thick in squares n exc 0.5 sqm each pane and glazing with complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of floor concrete in ground floors and pavings n exc15 cm thickness (below or above ground level) complete all as specified and directed.
Material and Labour for Non - skid coloured eramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl Screed bed or bedding layer of mortar 10 mm thick for laying floor finishes over & incl 25 mm thick PCC 1:2:4 type B0 complete all as specified and directed.
Material and Labour for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl Screed bed or bedding layer of mortar 10 mm thick for laying floor finishes over & incl 25 mm thick PCC 1:2:4 type B0 complete all as specified and directed.
Material & Labour vitrified tiles double charged,10 mm thick ,area of each tile exc 0.36 Sqm but n.exc 0.42sqm, in floor etc set and jointed in neat cement slurry over & incl 15 mm screed bed CM 1:4 over25 mm thick PCC 1:2:4 type B0 complete all as specified and directed.
Material & Labour Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl10mm thick plaster in cm 1:4 complete all as specified and directed.
Supply & Fixed in repairs 15mm Chromium plated fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified
Supply & Fixed in repairs 15 mm chromium plated pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified.
S & F in repairs cast aluminium (extruded section body) door closer by hydraulically regulated, designation No.3 univrsal type, suitable for door shutters up to 851mm to 1000 mm in width and of weight between 61 to 80 kg fixed complete alll as specified and directed.
Supply & Fixed in repairs 15 mm Stop valves, fancy type, chromium platedcast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply & Fixed in repairs gratting 125 mm dia with waste hole of PTMT (Min weights 40 gms) complete all as specified and directed.
Supply & Fixed in repairs CP Brass shower rose 125mm of size with or with out swivel joints any size including fixing to steel pipe or union as fixed in repair complete all as specified and directed.
Supply & Fix PVC connections 15mm size 600 mm long as fixed in repairs complete all as specified and directed.
Supply & Fixed in repairs brass float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe of bore 20mm complete all as specified and directed.
Supply & Fixed in repairs brass float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe of bore 15mm complete all as specified and directed.
Supply & Fix PVC connections 15mm size 600 mm long as fixed in repairs complete all as specified and directed.
Dismantling water tanks and removing to store capacity exceeding 250 ltrs and not exceding 500 ltrs complete all as specified and directed.
Dismantling water tanks and removing to store capacity exceeding 500 ltrs and not exceding 1000 ltrs complete all as specified and directed.
Supply & Fix rotational moulded PVC water tank double layered (Cylindrical vertical with closed top) 1000 ltrs capacity hoisted and fixed in positoin all as specified.
Supply & Fix rotational moulded PVC water tank double layered (Cylindrical vertical with closed top) 500 ltrs capacity hoisted and fixed in positoin all as specified.
Supply & Fixed in repairs PVC body valve less syphonic action type flushing cistern white low level with inlet ball valve float and handle including brackets 10 lits capacity with 32mm dia PVC bend pipe for low level cistern. complete all as specified and directed.
Supply & Fixed in repairs vitreous china pedestal pattern type white wash down water closet pan with Antimicrobial Solid Seat Cover but excluding flushing cistern and flush pipe complete all as specified and directed.
Supply & Fixed in repairs Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests ( complete all as specified and directed.
Supply & Fixed Aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
Supply & Fixed in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or floors Bore 110 mm inclding dismantling of old U/S pipes complete all as specified and directed.
Supply & Fixed in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or floors Bore 75 mm inclding dismantling of old U/S pipes complete all as specified and directed.
Supply & Fixed in repairs PVC (SWR) bends 75 mm dia radius complete all as specified and directed.
Supply & Fixed in repairs PVC (SWR) bends 110 mm dia radius complete all as specified and directed.
Supply & Fixed in repairs PVC (SWR) vent cowl 75 mm dia complete all as specified and directed.
S&F in repair vitreous china wash basin with pedastal, white flat back size 550x400mm excluding chain and plug and porcelain stopper but including brackets, including 32mm bore CP based fittings and PVC waste pipe suitable for 32mm bore complete all as specified & directed
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store. complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed.
S& F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors. complete all as specified and directed.
Supply & Fix 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors. complete all as specified and directed.
Supply and fix of Brass chromium plated 15mm wall mixer valve 3-in-1 for mixing hot and cold water, fancy type (Make Jaguar/Johnson/Parry ware or equivalent in specified makes as approved) including taking down the existing one.
Supply and Fix in repairs Health faucet (Hand shower) with 1metre flexible tube with wall hook, Chromium Plated (Make Jaguar/Johnson/Parry ware or equivalent in specified makes as approved) all as specified and as directed by the Engineer-in-Charge.
Supply & Fix in repairs 32mm dia waste coupling of PTMT (minimum weight 45 gms) with PVC waste pipe for WHB/urinal 750mm long complete all as specified and directed.
Supply & Fix in repair 40/50mm dia suitable for Sink waste coupling of PTMT with PVC waste pipe for Sink 750mm long complete all as specified and directed.
S&F plastic water closet seat cover, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device of make fixed with CI brackets fixed in repairs. complete all as specified and directed.
Supply & Fixed 15 mm CP angle cock chrome finish cast copper alloy, with wall flange complete all as specified and directed.
Supply & Fix in replacemnet of following fiiting of GI fittings of size 15mm bore pipe including necessary plumbing work taking up or down G I pipe and refixing at the same position complete all as specified and directed.
Long bend
Socket
Elbow
Nipple upto 100 mm long
Reducer socket 15/20mm
Reducer socket 25/20mm
Reducer socket 25/15mm
Supply & Fix in replacemnet of following fiiting of GI fittings of size 20mm bore pipe including necessary plumbing work taking up or down G I pipe and refixing at the same position complete all as specified and directed.
Long bend
Socket
Elbow
Nipple upto 100 mm long
Npple upto 150 mm long
Supply & Fix 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed by the Engineer-in-Charge.
S&F coloured Toilet paper holder of CP fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F fancy type stainless steel Drapery rods 19/20 mm bore for curtain rails with fixing stainless steel brackets, fency stainless steel stops and curtain rings (06 Nos per mtr) complete all as specified and directed .
S &F of 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed .
S&F Vitreous China Urinal bowl type or half stall pattern , white including flush pipe and waste pipe) Make Parryware including Spreader Code No C8095 and other accessories and Bracket with fixing arrangement complete all as directed by the Eng-in-Charge
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60 gms ) complete all as directed by the Eng-in-Charge
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as directed by the Eng-in-Charge
Supply & Fix Shelf of PTMT fixed with including chromium plated brass screw and wooden/plastic cleats (Minimum weight 300 gms ) complete all as specified and directed .
M& L for aluminium dividing strips width 28mm and , 1.5mm thick as in door stopper inserted in position conform to design complete all as specified and directed .
M& L for Cleaning of sewage lines which are blocked /filled with sludge, semi solid/ material etc by roding manholes to manholes manually or by sewage cleaning machine without causing any damage to sewage line / manholes manholes covers taking out and refixing the covers and removing the sludge to a non inhabitant area or buried into ground all as specified for the 150mm internal dia of pipe complete all as specified and directed.
M& L for Cleaning of sewage lines which are blocked /filled with sludge, semi solid/ material etc by roding manholes to manholes manually or by sewage cleaning machine without causing any damage to sewage line / manholes manholes covers taking out and refixing the covers and removing the sludge to a non inhabitant area or buried into ground all as specified for the 100mm internal dia of pipe complete all as specified and directed.
Cleaning of septic tanks, soakage well of any capacity and manholes by Desludging / dewatering including inlet/ outlet chambers, removing out all scum, silt, residuals sludge (both organic and inorganic nature) after plugging the incoming sewage lines through combined high pressure water jetting cum suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, all as directed by Engineer-in-Charge
Cleaning of blockage of any type of wc (Indian/pedestal) from WC pan to Ist manhole in single storied bldg including resetting/ refitting of asccess door in soil pipe where opened without causing any damage to the wc pan 'P' or 'S' trap and pipe including fitting complete all as specified and directed.
M& L for Cleaning of blockage of any type in Nahani trap provided in bath room, kitchen and indoor waste water pipe of kitchen sinks and WHB and removing all the sludge and foreign material from the trap and waste pipe from blocked trap to gully trap/ surface drain wherever opened or without causing any damage to the trap and pipe complete all as speciffied
M& L for Cleaning of service RCC/Ferro/PVC service/over head tank cleaning process as under (a) Dewatering using submerssible pump/bailing out of water to dispose the minimum level of dirty water from the tank. (b) Cleaning the tank/ UG sump bottom, walls and ceiling using high pressure water jet to dislodge the algae calcinations, dirt etc. (c) Disposing the dirt water sludge etc., using specially designed sludge removal pump. (d) Cleaning the tank inside throughly by using industrial grade vaccum pump to make the tank inside free from dirt, algea and sludge etc. (e) Treating the inside walls, bottom, ceiling of tank including all nooks and corners by using and spraying anti bacterial agent such as hydrogenperoxide (bio degradable) for disinfection of tank inside. (f) Total disinfection and sterlisation of tank hyginecally cleaned and bacteria free and safeby Eco-Friendly for storage of water. Note :- Incl cleaning of outlet pipe upto stop cock/gate valve by removing and refixing the same and making the line serviceable after cleaning & Qty of tank are consider for cleaning twice in a Year and Date of cleaning to be written over head tank after cleaning.
For exc 250 ltrs and not exc 500 ltrs capacity
For exc 501 ltrs and not exc 1000 ltrs capacity
For exc 1001 ltrs and not exc 2000 lt capacty
For exc 2001 ltrs and not exc 5000 lt capacty
S&L in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in repair 15 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Excavation in trenches in soft/ loose soil exc 1.5 m deep and getting out including forming bottom to required level or slop for laying pipe, concrete bed manhole etc n.exc 10 Sqm on plan complete all as specified (pipe and concrete bed shall be measured and paid separately )
Returning filling in soft/ loose soil including spreading levelling ,watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
Removing of excavated surplas materials to a distance exc 50 m but nexc 100 mm and depositing where directed a level n.exc 1.5 mtrs above the starting point complete all as specificed complete all as specified and directed.
Demolition or breaking up 150 mm dia drain pipe including fittings of any desciption in any position and removing rubbish upto a distance of n. exc 50 mtr complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 for 150 m bore of pipe complete all as specified and directed.
M&L Reinforced concrete pipes, class NP3, laid and jointed complete with collars 150 mm bore laid in trenches and jointed with CM 1:1 complete all as specified and directed.
Demolition of brick work of any description and in any position built in CM and removing rubbish upto a distance of n exc 50 mtr complete all as specified and directed.
M&L for brick work built in CM 1:4 with sub class 'B' bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work internal faces in manhole in CM 1:4 using WPC as per manufacturer instruction incl finishing the surfaces even & smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick on other than fair faces of brick surfaces or concrete surfaces and finished surfaces even & fair in CM 1:6 complete all as specified and directed.
Demolition of reinforced cement concrete as in cover slabs of any description, removal of debris to beyond MD land as directed complete all as specified and directed.
M&L for precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in manhole cover slab with plain fair faces and set in CM 1:4 complete all as specified and directed.
M&L TMT mild steel bars 6 mm to 8 mm dia cut to length, bent to shape required, including cracking, bending,spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per Srl item No 125 but 10 mm dia MS round bar as in handle complete all as specified and directed.
SCHEULE-A PART-II (E/M WORKS) M & L for Dismantaling /Opening of upper portion of Disel Engine 82.5 KVA (Make : Greaves/ Kirloskar/ Cummins or any other make) air cooled,turbo charged ,Vertical type for top over hauling, repair/ servicing of engine including taking out rediator /fuel pump,water Pump,Turbo charger etc (Egnine oil and coolent reaquired for this job is deemed to be included in the quoted rate. (a) Dismantaling/Opening of complete cyllinder head assebly rockers arms assemblypiston head assembly ,sleeves byremoving nuts &bolts for repair complete. (b) Servicing & washing of complete engine partswith kerosine oil ( c) Re- assembling of engine after replacementof UNSV/defective parts with new parts as listed in given below per job shall be deemed to be included in this rates and testing of engineas per company recommendation after reassembling all parts as directed to the satifaction of the Engr-in -Charge Note : Repair and Transportation (BY JCB / HYDRA OR ANY OTHER MEANS) charge for carrying out repair & reinstall on same installation back shall be deemed to be included in this rates
Supply in replacement of following parts given below rates shall be deemed to be above job included . complete all as specified and directed.
Valve Exhaust
Valve inlet
Insert Valve Seat
Guide Valve
Cup Injector
Fip Element
Gasket Set
Hose Pipe
Fuel Filter
Lubrication Oil Filter
Super By Pass Fillter
Hose Clip Set
Piston set Complete
Ring Set Complete
Cyllinder Linner
Connecting Rod Bearing
Gasket Set Cyllinder Head
Callibration of Fuel Pump
Head Repair Work
Callibration of injectors of Nozzels
Lubrication Oil Pump
O ' Ring Set Complete
Set of Fuel Flexible Pipe
Stem Seal
M & L for Dismantaling /Opening of upper portion of Disel Engine 62.5 KVA to 40 KVA (Make : Greaves/ Kirloskar/ Cumiuns or any other make) air cooled,turbo charged ,Vertical type for top over hauling, repair/ servicing of engine including taking out rediator /fuel pump,water Pump,Turbo charger etc (Egnine oil and coolent reaquired for this job is deemed to be included in the quoted rate. (a) Dismantaling/Opening of complete cyllinder head assebly rockers arms assemblypiston head assembly ,sleeves byremoving nuts &bolts for repair complete. (b) Servicing & washing of complete engine partswith kerosine oil ( c) Re- assembling of engine after replacementof UNSV/defective parts with new parts as listed in given below per job shall be deemed to be included in this rates and testing of engineas per company recommendation after reassembling all parts as directed to the satifaction of the Engr-in -Charge Note : Repair and Transportation (BY JCB / HYDRA OR ANY OTHER MEANS) charge for carrying out repair & reinstall on same installation back shall be deemed to be included in this rates
Supply in replacement of following parts given below rates rates shall be deemed to be above job included .
Valve Exhaust
Valve inlet
Insert Valve Seat
Guide Valve
Cup Injector
Fip Element
Gasket Set
Hose Pipe
Fuel Filter
Lubrication Oil Filter
Super By Pass Fillter
Hose Clip Set
Piston set Complete
Ring Set Complete
Cyllinder Linner
Connecting Rod Bearing
Gasket Set Cyllinder Head
Callibration of Fuel Pump
Head Repair Work
Callibration of injectors of Nozzels
Lubrication Oil Pump
O ' Ring Set Complete
Set of Fuel Flexible Pipe
Stem Seal
M & L for Servicing of DG Sets of capacity 82.5 KVA of make (Make : Greaves/ Kirloskar/ Cummins or any other make) by the authorised Engineer of respective manufacturer of DG Set continous operational condition including the following checkings all as specified and directed by Engr-in -charge (Egnine oil and coolent reaquired for this job is deemed to be included in the quoted rate . (i) Removing the existing engine oil, clean the oil sump and refilling with required quantity of new engine oil 20W40 & coolant upto top. (ii) Checking of fan motor hub (iii) Checking exhaust and inlet manifold belt and cap screw (iv)Cleaning of radiator inside and out side thoroughly with solution (caustic soda) to the entire satisfaction of Eng-in-charge by removing and re-fixing in original position after cleaning. (v) Checking and adjusting injector and valves, tappet and replace the gasket including cost of gasket. (vi) Cleaning fuel inlet connections and screw, (vii) Checking of vibration damper and rectified. (viii) Servicing of turbocharger by checking, leakage tightening of mounting screws & nuts and replace oil. (ix) Checking water temperature safety control (x) Checking and correcting up impeller of water pump for excess play. (xi) Servicing of governer and Changing of governor oil. (xii) Checking and adjusting all fan belt. (xiii) Any other check as per manufacturer`s instruction Note:- Necessary spare parts required if any will be measured and paid under relevant item
S & F in repairs Kit, fuel filter and ring
S & F in repairs Element for Lubrication oil filter.
S & F in repairs Kit, Element of super bypass filter.
S & F in repairs Seal, O Ring and Air cleaner.
S & F in repairs Kit Conversion
S & F in repairs Gasket, Rocker lever cover
All as per item no.131 above but Diesl Engine of 62.5 KVA DG Set. complete all as specified and directed.
S & F in repairs Kit, fuel filter and ring
S & F in repairs Element for Lubrication oil filter.
S & F in repairs Kit, Element of super bypass filter.
S & F in repairs Seal, O Ring and Air cleaner.
S & F in repairs Kit Conversion
S & F in repairs Gasket, Rocker lever cover
All as per item no.131 above but DG Sets of Capacity 40/30 KVA DG set complete all as specified and directed.
S & F in repairs Kit, fuel filter and ring
S & F in repairs Element for Lubrication oil filter.
S & F in repairs Kit, Element of super bypass filter.
S & F in repairs Kit Conversion
S & F in repairs Gasket, Rocker lever cover
M&L for Rewinding of armature of Dynamo/alternators 12V/24V volts with `F' class copper wire to match existing gauge including dismantling of old coil , cleaning thoroughly winding with super enameled copper wire of existing size and gauge,varnishing, drying etc and fixed with dynamo/alternator properly tesing and commissioning all as specified all and directed by Engr-in-Charge.
S & F repair radiator hoses of size 40mm dia or as per existing dia and 60 cm length for any capacity of DG set including jublee clip, clamp nuts etc are properly fixed and connected.as directed to the satifaction of the Engr-in -Charge
S & F in replacement of flexible pressure pipe for lubricant size of 60 cm length for oil and fuel connection for complete suitable for 40/62.5/82.5 KVA Engineas directed to the satifaction of the Engr-in -Charge
Supply & filling of Engine oil 20W/40f complete all as specified and directed.
Supply & filling of water packed in sealed gallan of 5 Ltrs complete all as specified and directed.
Supply only water coolant(diluted)in radiator (make volve line or equivalent) including removal of old water/coolant, all as directed by Engineer-in-Charge.
M & L for Dismantling and removing of water pump assembly of any capacity any type of DG Set complete from the engine,repair/overhauling the same by replacing tornout components like bearing,impeller,bushes, oil seal,water seal,gaskets etc. reassembling,refixing and testing complete as directed to the satifaction of the Engr-in -Charge
Repair/overhauling of self starter 12V/24V including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch,carbon brushes,brush spring etc.as directed to the satifaction of the Engr-in -Charge for the 40/62.5/82.5 KVA DG Set
M & L for replacement of totally damaged self starter 12V/24V complete assembly suitable for any capacity of DG Set complete as specified and as directed.
Repair/overhauling of dynamo including replacement carbon, brushes holder, spring, commutator /slipring assembly bearing, regulator etc. of any make, type and capacity.
Supply in replacement of electrically operated fuel shut down valve assembly complete testing and commissioning as specified and directed by Engr.in-charge including dismantling and removal of old U/S valves of any capacity DG set. complete as specified and as directed.
M & L for Servicing/repairs of AMF panel complete including cleaning resetting/adjustment of relays,calibration of time delay relays, checking and replcement of diods, if required ,resistors contactor etc. complete for any make/type and capacity of DG sets. complete all as specified and directed.
M & L for Disconnecting and dismantling the alternator unit of 82.5 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
M & L for Disconnecting and dismantling the alternator unit of 62.5 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
Supply & fix in replacement of diode assembly complete suitable to match the existing one of 82.5 KVA alternator excitor unit. complete as specified and as directed.
Supply & fix in replacement of diode assembly complete suitable to match the existing one of 62.5/40 KVA alternator excitor unit. complete as specified and as directed.
Supply & fix in replacement of PVC insulated battery lead with 16 Sq.mm copper conductor cable of length 2 mtr with copper/brass clamps and lugs for fixing on battery terminals and self starter complete as specified and as directed.
Supply & fix in replacement of rectifiers for alternators suitable for Gensets upto 40/62.5/82.5 KVA capacity complete as specified and as directed.
Supply & Fix in replacement of water temperature gauge complete with cable and accessories at the last range 0 to 150 degree centigrate complete as specified and as directed.
Supply in replacement of oil temp gauge as per existing site requirement complete as specified and as directed.
Supply in replacement of oil pressue gauge as per existing site requirement complete as specified and as directed.
M & L for Dismantling the following defective Fuel Injector Assembly of any capacity from the existing foundation and engine including taking down all electrical connections transporting to approved authorised workshop, after setting up opening the complete, connector plate, gasket & complete overhauling re- assembling the Fuel Injector after transporting back to site re-installing carrying out alignment of complete DG set reconnecting up all electrical connections testing and commissioning complete the following capacity of DG set (Note:- (a) Rate quoted shall be deemed to be inclusive making good the distrubed surfaces (b) The DG set shall be tested for the satisfaction of Engr -in -charge to achive designed parameters.
82.5/62.5 KVA DG
40 KVA DG
S & F in repair battery terminal brass superior quality suitable for 180 AH 12 Volts Battery complete as specified and as directed.
Supply and fixing in replacement of ignition switch and key of 82.5 KVA DG Set complete as specified and as directed.
Supply and fixing in replacement of ignition switch and key of 62.5/40 KVA DG Set
Supply and fixing in replacement of AVR unit of 82.5 KVA for matching the existing AVR unit, complete all as specified and directed by Eng-in charge.
Supply and fixing in replacement of AVR unit of 62.5 KVA to 40 KVA for matching the existing AVR unit, complete all as specified and directed by Eng-in charge.
S&F in replacement of contactor suitable for AMF panel contactor MNX 25 3pole 240V as per existing contactor of site complete all as specified and as directed
S&F in replacement of contactor suitable for AMF panel contactor MNX 16 3pole 240V as per existing contactor of site complete all as specified and as directed
S&F free lead acid battery 12 volts 180 AH complete all as specified and as directed
M&L for servicing/ cleaning of MS diesel tank of DG set 82.5 KVA by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including repalcement of drain valve, outlet pipe complete all as specified and as directed.
M&L for servicing/ cleaning of MS diesel tank of DG set 62.5/40 KVA by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including repalcement of drain valve, outlet pipe complete all as specified and as directed.
S&F in replacement of MCCB, three pole, 160 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed
S&F in replacement of MCCB, three pole, 125 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed
S&F in replacement of MCCB, three pole, 100 Amp 415 volts, 50 Hz breaking capacity not less than 25 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed(
S&F in replacement, fan belt suitable for 40 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 62.5 KVA DG set complete all as specified and as directed.
S&F in replacement, fan belt suitable for 82.5 KVA DG set complete all as specified and as directed.
M & L for Dismantling/ taking down complete radiator assembly of DG set 82.5 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete all as specified and directed.
M & L for Dismantling/ taking down complete radiator assembly of DG set 62.5 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete all as specified and directed.
M & L for Dismantling/ taking down complete radiator assembly of DG set 40 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete all as specified and directed.
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 70 sq 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 50 sq 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 35 sq 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply , laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavu duty aluminium conductor LT 1100 V grade cross sectional area 25 sq 4 core, complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a soft/Hard soil for laying underground cables/ errection of steel tubular poles / stay pit etc all as directed by Engr-in-charge.
Returning, filling in incl spreading,levelling watering and well ramming in layer n exc .25 cm in soil each layer complete specified and directed by Engr-in-Charge.
Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge.
M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed.
M & L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class 'B' (old size) bricks laid dry flat, complete all as specified and directed.
S&F in replacement of Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 100 amps, including taking out unservicable one complete all as specified and directed by Engineer-in -Charge.
S&F in replacement of Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 200 amps, including taking out unservicable one complete all as specified and directed by Engineer-in -Charge.
Supply in replacement of 24 Volt Relay ,taking down and reconnecting up all electrical connections testing and commissioning complete as directed to the satifaction of the Engr-in -Charge
Supply in replacement of 12 Volt Relay ,taking down and reconnecting up all electrical connections testing and commissioning complete as directed to the satifaction of the Engr-in -Charge
Supply and fixing in replacement of Didital volt meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of Digital Amp meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of Digital Frequency meter as per existing size complete all as specified and directed.
Supply and fixing in replacement of indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead of galvanised iron strip of size 25x4 mm connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore light gradeGI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009 and testing on completion.
Taking down unsv ceiling fans 1200/1400 mm sweep 230 v, AC supply, single phase from site, depositing in MES store yard, dismantling all parts, checking serviceability of all parts & continuity of copper winding, (Burn out winding Fan should be staking aside for rewinding), including cleaning all the components of fan, oiling , greesing, including replacement of rusted /unsv nuts, bolts split pin rubber reel , machine screws, shaft, capacitor, clamps,etc as required, reassembling the fan and testing complete all as specified and directed. Note:- (i) Rewinding of fans should be measure and paid separately under appropriate items of schedule (ii) Major parts like Fan capacitor, clamps with rubber real etc measured and paid separately as Supply only items (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete
Taking down unsv Exhaust Fan 200/230/300 mm sweep 230 v, AC supply, single phase from site, depositing in MES store yard, dismantling all parts, checking serviceability of all parts & continuity of copper winding, (Burn out winding Fan should be staking aside for rewinding), including cleaning all the components of fan, oiling , greesing, including replacement of rusted /unsv nuts, bolts split pin rubber pad , machine screws, shaft, capacitor, clamps, etc as required, reassembling the fan and testing complete all as specified and directed. Note:- (i) Rewinding of fans should be measure and paid separately under appropriate items of schedule (ii) Major parts like Fan capacitor, clamps with rubber Pad etc measured and paid separately as Supply only items (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete
Taking out, burnt winding wire from ceiling fans (Which required rewinging, Obtained from item No.01) motor of 1200/1400 mm sweep 230 v, AC supply, single phase, Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & size, thoroughly cleaning all the components of fan, oiling , greesing, replacement of rusted /unsv nuts, bolts split pin rubber reel , machine screws, shaft etc as required reassembling the fan, testing complete & Transporting back to MES store yard complete all as specified and directed.
Taking out, burnt winding wire from Exhaust fans (Which required rewinging, Obtained from item No.02) motor of 300 mm sweep 230 v, AC supply, single phase, Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & size, thoroughly cleaning all the components of fan, oiling , greesing, replacement of rusted /unsv nuts, bolts split pin rubber Pad , machine screws, shaft etc as required reassembling the fan, testing complete & Transporting back to MES store yard complete all as specified and directed.
All as per Srl Item No-198 above but for exhaust fan of size 400/450 mm of any make complete all as specified.
S&f in replacement of rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required.
S&f in replacement ball bearing of ceiling / exhaust fan of any sweep complete all as specified and directed.
S&F in replacement condensor 1.5 MFD suitable for PVC exhaust fan / wall mounting fan of any sweep complete all as specified and directed.
S&F in replacement condensor 2.5 MFD suitable for ceiling fan / wall mounting fan of any sweep complete all as specified and directed.
S&F in replacement condensor 4 MFD suitable for PVC exhaust fan of any sweep complete all as specified and directed.
M&L spray painting of ceiling fan, fan blades, down rod, canopy etc with a coat of synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the MES fan numbers etc with black paint complete all as directed.
M&L spray painting of Metalic body Exhaust fan, fan blades etc with a coat of synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the MES fan numbers etc with black paint complete all as directed.
S&F motor of Exhaust Fan Capacity 300 mm including taking down of old unsv motor complete all as specified and directed.
S&F 1200 mm sweep ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V. Min air delivery 210 CFM, Five star rating complete all as specified and directed. Note: Old unsv Ceiling Fan will be deposited in MES store yard.
Supply & fix Exhaust fans made of sturdy Engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, RPM 1200, copper winding of sweep 200/250 mm, incl all fixing accessories required including making hole & regd length of 3 core 1.0 sqmm PVC multistranded copper conductor, and testing complete all as specified and directed. Note: Old unsv Exhaust fan will be deposited in MES store yard.
Replacement of old unserviceable ceiling fan blades made of MS sheet duly powder coated ,of type make and colour as of ceiling fan suitable for 1200mm sweep ceiling fan of any make incl all accessories complete all as specified and directed.
Replacement of Blade assembly of Exhaust fan with fixing hexagonal nut of size 300/450mm complete all as specified and directed.
Replacement of iron Frame of exhaust fan 300/450 mm sweep 4 way with welded and painted complete as specified and as directed.
. M/L Gun metal bush of exhaust fan complete all as specified and directed
S&F in replacementl of PVC canopy suitable for ceiling fan of any size and make as required. complete all as specified and directed.
S&F in replacement of PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm complete all as specified and directed.
S&F in replacement of down rod of ceiling fan made of GI pipe medium grade 15 mm bore of length upto 600 mm including cutting, threading, painting etc as required. complete all as specified and directed.
S&F in replacement and connecting new fan motor, single phase 230 volt 50 Hz copper wounded three speed suitable for desert cooler up to 500 mm sweep size etc complete including dismantling and removing of existing unserviceable fan motor with blades from the desert cooler of any make/type/capacity including removing of all accessories etc all as specified and directed by Engineer-in-Charge.
S&F in replacement of submersible type tullu pump for desert cooler of capacity 1/85 HP, single phase 230 volt 50 Hz copper bound etc incl fixing accessories complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of wooden wool pads including wire mesh suitable for up to 5000 cuf/M complete all as specified and directed by Engineer-in-Charge. (Note :- Weight will be measured dry).
Taking down of desert cooler fixed at any position, cleaning internally and externally by scraping all scales dirt etc and repairs to desert cooler to check leakage, tightening ( By replacing screws, nuts and bolts etc ) including painting of desert cooler with spray machine with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer, letters, Refixing of the desert cooler after necessary oilling and greasing of fan and water lifting pump complete all specified and directed
S&F in replacement of side grill made out of 22 SWG gauge Gl sheet including applying two coats of spray paint of off white I grey colour over one coat of primer (red oxide) suitable for desert cooler of capacity up to 5000 cuff min complete all as directed by the Engineer-in-Charge.
S&F in replacement of PVC pipe of 15 mm dia with water PVC Three way water distributor, heavy duty and PVC elbow complete all as specified and directed by the Engineer-in-Charge.
S&F in replacement of desert cooler body made of 20 guage PGI Sheet suitable for evaporative type desert cooler of any size including side panel-03 Nos and front grill with 20 guage PGI sheet and water tank height 20 cm and grill with fins, electriclal wiring and connection with on/off switch piano type with distribution PVC cable 3 core 23/0.0076-3m with top plug 5 Amp-Ol No, 15mm float vlave-01 including duly painted complete body internaly and externaly and all side panel inner and outer side applying two coats of synthetic enamel paint by spraying with gun of approved colour over a coat of red oxide primer complete all as specified and directed.
M& L for Re-wiring of desert cooler with suitable size of copper conductor PVC insulated cable and providing main lead three metre long of 3 core PVC insulated copper conductor of size 23/ .0076 complete all specified and directed
S&F in replacement of legs for fan motor for desert cooler made out for 18 SWG MS plate complete all as specified and directed by the Engineer-in-Charge.
Dismanting and taking out Old, Unservicable fan motor from the desert cooler and Rewinding with supper enamel copper winding wire of suitable size, varnishing etc including replacement of bushes, assembling testing and refixing at the existing site complete all as specified and directed
M& L for fabrication of desert cooler stand made out of MS angle iron 40x40x6mm thick all as per existing size suitable at site incl painting ith two coats of synthetic enameld paint over a coat of red oxide primer coat replacement complete all as specified and directed.
S&F in replacement of factory made PVC fan blade suitable for desert cooler of capacity up to 5000 cuf/Min complete all as directed by the Engineer-in-Charge.
S&F in replacement of factory made metalic fan blade suitable for desert cooler of capacity up to 5000 cuf/Min complete all as directed by the Engineer-in-Charge.
S&F in replacement of front grill made out of Gl sheet of 20 SWG gauge including applying two coats of spray paint of off white/gray colour over one coat of primer (red oxide) suitable for desert cooler of capacity up to 5000 cuf/Min complete all as directed by the Engineer-in-Charge.
Disconnecting the inlet and outlet connections of the existing Geyser 25/50 Ltr, taking down carefully, cleaning/descaling the blocks both in GI pipes and water heater refixing the bolts by proper grouting in the wall and refixing the water heater in the same or in other places as directed by Engr in charge
S&F in place of unsv PVC connection of any make with (ISI Mark) having10mm dia, 45 cm long with steel reinforcement suitable for hot & cold water geyser outlet supply with 02 Nos of Unions/ cup shaped cover with washers complete all as specified & directed
S&F in Replacement of unserviceable heating element of geyser 2KW/1.5 KW of any pattern complete all as specified & directed
S&F in Replacement of unserviceable thermostat of geyser 2KW/1.5 KW of any pattern complete all as specified & directed
S & F in replacement of pressure release valve suitrable for 25/50 ltr electric water heater complete all as specified & directed
S&F in replacement of U/S apparatus plate of geysers 25/50 litre capacity by brazing not exceeding 5 mm thick complete all as specified & directed
S&F in Replacement of unserviceable Inner Tank of geyser steel body of capaciy 25/50 Ltrs as existing pattern complete all as specified & directed
S&F in Replacement of unserviceable PVC flexible pipe inlet 16mm outer dia and 450 mm long for hot/cold water heavy duty with brass nuts & bolts. complete all as specified & directed
Disconnecting the inlet and outlet connections of the existing solar water heater 300 Ltr, taking down carefully, cleaning/descaling the blocks both in GI pipes and water heater refixing the bolts by proper grouting in the wall and refixing the water heater in the same or in other places as directed by Engr in charge
S&F in Replacement of unserviceable heating element of solar water heater 300 Ltr 2KW/1.5 KW of any pattern complete all as specified and directed.
S&F in Replacement of unserviceable thermostat of solar water heater 300 Ltr 2KW/1.5 KW of any pattern complete all as specified and directed.
S&F in replacement of apparatus plate of solar water heater 300 Ltr 25/50 litre capacity by brazing not exceeding 5 mm thick complete all as specified and directed.
S&F in Replacement of unserviceable float valve with new brass Float valve of desert coolers complete any make 15 mm dia complete all as specified and directed.
Taking out existing unserviceable compressor sealed unit from window/split type air conditioner 1.5 Ton capacity including removal of unserviceable strainer filter etc. complete all as specified and directed by Engineer-in-charge.
S&F in replacement and connecting of new compressor sealed unit of capacity 1.5 Ton for window/ split type suitable for air conditioner of any make/as per existing type including replacement of foundation bolts, rubber pad, strainer capillary tubes, suction and discharge pipe line, wiring kit, vacuuming the system, supply and charging Gas (R-22/R-134A), detection of leakage etc., brazing and testing to achieve proper cooling effect complete all as specified and directed by Engineer-in-charge.
M&L for leak detection by nitrogen pressure test in refrigerant system for split/ window type AC 1.5 TR capacity, cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required quantity to achieve desired cooling including installation at site and testing on full load for 24 hours complete all as specified an directed. (Note:- Additional gas required will be measured & paid separately under relevant item as supply only).
Taking blower motor from air conditioner of 1.5 Ton capacity and make / and fixing as per existing type and replacing with the new motor, single phase, 200/230 volt, 50 Hz, 1/5 HP capacity, ISI Marked in the same position, testing etc complete all as specified and directed by Engineerin-Charge.
S&F in replacement of running capacitor (36 mfd) suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of starting capacitor (100/120 mfd) suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostate switch of temperature range of 160C to 300C suitable for air conditioner of any make / type I capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of grill with knob made of fiber plastic body suitable for window type AC of any make /type/ capacity complete as per existing make all as specified and directed by Engineer-in-Charge.
S&F in repair of factory made wall mounted/ floor mounted type AC outdoor unit (coloured) stand of superior quality ISI Marked suitable for AC of 1.5 TR capacity complete all as specified and directed.
S&F in replacement of starting relay suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of plastic filter for window type AC 1.5 ton capacity complete all as specified and directed.
S&F in replacement of fan motor ISI marked for indoor unit of split type air conditioner of any make / type and capacity including making connection etc complete all as specified and by Engineer-in-Charge.
S&F in replacement of fan motor ISI marked for outdoor unit of split type air conditioner of any make / type and capacity including making connection etc complete all as specified and by Engineer-in-Charge.
S & F in Repair/ replacement of electronic control circuit card suitable for air conditioner of any make I type and 1.5 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of split/ window type air conditioner of capacity 1.5 Ton of any make and type by replacing unserviceable compressor and other parts from the machine including charging of refrigerant gas and changing of wiring with proper size PVC insulated wires as directed by replacing air filter, oiling of blower, condensor fan motors, replacement of bushes 2 Nos for fan motor, cleaning of condensor coil by high pressure water & cleaning liquid complete as directed, installing the air conditioner at location where directed after proper repair and testing complete at site as per the satisfaction of Engineer-in-Charge. (Note • M&L for replacement of compressor, spare parts and gas shall be measured and paid separately under relevant items).
M&Lfor scraping of old paint by wire brush from body of window type AC and applying base material for smooth surface and applying 2 coat of synthetic enameled spray paint with gun over one coat of primer complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of plastic filter for split type AC 1.5 ton capacity complete as as directed
S&F in replacement of cooling coil 1.5 ton split type AC make as directed by Engr-in-Charge.
Supply and fixing in replacement sheet metal enclosure industrial type complete plug socket, plug top and earth plug complete with SP MCB 20 Amp complete all as specified and directed.
Supply and replacement of fan blade suitable for split type/ window AC capacity 1.5 ton as per sample all as spacified and directed.
S&F in replacement of plug top 3 Pin 5 Amp 240 volts all as specified and directed.
S&F in replacement of plug top 3 Pin 15 Amp 240 volts all as specified and directed.
Taking down existing unserviceable outdoor unit and supply and fix for new outdoor unit for 1.5 TR capacity split AC suitable for working with and including non CFC refrgerant gas with blower fan motor, cooling coil all pre-wired with compressor of make as per existing complete all as specified and as directed.
S&F in replacement for indoor unit for split type air conditioner+ 10% capacity wall mounted operation on 230 volts 1.5 ton 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system including fan motor of make as per existing including taking down of old existing unserviceable one, complete all as specified and as directed.
M&L for sub main wiring PVC insulated, 1100 volts grade single core multistranded copper conductor FRLSH cable conforming to is specifications, 2 run of 4 sqmm including 1 run of 4 sqmm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25mm dia rigid PVC conduit and conduit accessories fixed on wall/ ceiling etc or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wireing. (Note :- 3 run of 4 sqmm and 1 run of PVC conduit will be measured as 1 unit).
Taking out unserviceable compressor from refrigerator of capacity 175 to 360 ltr of any make by un-screwing from base plate after disconnecting all electrical and suction / discharge pipe connections complete and providing all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing charging of refrigerant gas as per requirement to achieve proper cooling effect and testing on completion complete all as specified and as directed. (Note :- M&L in replacement of compressor (sealed unit), Gas and Parts required for satisfactory repair shall be paid and measured separately under relevant items).
Supply and fixing in replacement and connecting of new compressor sealed unit suitable for refrigerator of capacity 300/ 310/ 360 ltrs and any make/type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line, vacuuming the system, supply and charging Gas (R-22/R134A), detection of leakage etc., brazing and testing to achieve proper cooling effect complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 271 above but for capacity 175/180 ltrs.
M&L for leak detection by nitrogen pressure test in refrigerant system of Refrigerator of any capacity and make, by cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required quantity to achieve desire cooling including installation at site and testing on full load for 24 hours complete all as specified an directed. (Note:- Supply and charging additional gas required will measured & paid separately under relevant item.)
S&F in replacement of starting relay and over load protector ISI marked suitable for refrigerator of any make/ type/capacity including making connection complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostat switch with knob ISI marked suitable for refrigerator of any make/ type/ capacity including making connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of cabinet bulb with door switch ISI marked suitable for refrigerator of any make/ type/ capacity including making connection complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of vegetable tray of single/ two pieces type suitable for refrigerator of any make/ type/ capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of crisper tray suitable for refrigerator of any make/ type/ capacity complete all as specified and dire&d by Engineer-in-Charge.
S&F in replacementof bottle shelf/ egg shelf suitable for refrigerator of any make/ type/ capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of magnet type door gasket suitable for refrigerator of any make/ type/ capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of toughened glass self/ cover for vegetable tray suitable for refrigerator of any make/ type/capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of evaporator coil ISI marked suitable for refrigerator of any make/type/capacity including making connection complete all as specified and directed by Engineer in-Charge.
S&F in replacement of condenser coil ISI marked suitable for refrigerator of any make/type/capacity including making connection complete all as specified and directed by Engineer in-Charge.
S&F in replacement fan motor for refrigerator 175/ 180/ 300/ 310/ 360 ltrs capacity complete as per existing make all as specified and directed
S&F in replacement freezer with cooling/pipe capillary or compressed freezer complete for refrigerator 175/ 180/ 300/ 310/ 360 ltrs as per existing make complete all as specified and directed.
S&F in replacement PC Board for 175 to 360 ltr refrigerator suitable make complete all as specified and directed by Engr-
Supply and fixing in replacement of timer for refrigerator ISI marked complete all as specified and directed by Engineer-in-Charge.
Taking out existing unserviceable compressor sealed unit from the water cooler of any make/ type/ capacity including removing of all other unserviceable pans/ spares such as strainer filer, capillary tube, suction / discharge pipe, thermostat switch, float valve, push cook running capacitor, starting capacitor, over load relay etc complete all as specified and directed by Engineerin-Charge.
S&F in replacement and connecting of new compressor sealed unit suitable for water cooler of any make/ type, 120/150 ltr/ hr cooling capacity, medium temperature range, including replacement of filter and making connection, vacuuming the system, supply and charging Gas (R-22/R134A/R-410A), detection of leakage etc., brazing and testing to achieve proper cooling effect complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 289 here-in-before but water cooler of any make / type and 40/80 ltr/ hr cooling capacity. complete all as specified and directed.
M&L for leak detection by nitrogen pressure test in refrigerant system of water cooler of any make/ type of 40/801trs/ hr cooling capacity, by cutting, brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required quantity to achieve desired cooling including installation at site, testing of water cooler on full load for 24 hours continuously complete all as specified an directed. (Note:- Supply additional gas required will measured & paid separately under relevant item).
S&F in replacement of fan motor ISI marked in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of fan motor blade ISI marked PVC/ metallic type in existing water cooler of any make/type/ capacity including all fixing accessories etc complete all as specified and dire&d by Engineer-in-Charge.
S&F in replacement and connecting of running capacitor 30 Mfd ISI marked in existing water cooler of any make/ type/ capacity including fixing accessories etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement and connecting of thermostat switch ISI marked in existing water cooler of any make/type/ capacity including fixing accessories etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement and connecting of chromium plated push cock tap, in existing water cooler of any make/ type/ capacity including fixing accessories etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement and connecting of PVC heavy duty waste water pipe of 32/40 mm size and min 1.5 m long, including repair of waste water tray in existing water cooler of any make/type/capacity including fixing accessories etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of damaged water tank from water cooler of any make/type but of capacity 120/150 ltr and supply & fl)dng new stainless steel water tank ISI marked including fixing accessories etc complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 298 above but water cooler of any make/type but of 40/80 ltr capacity. complete all as specified and directed.
S&F in replacement of evaporator coil ISI marked suitable for water cooler of any make/ type/ capacity including fixing accessories and making connection charging etc, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of condenser coil ISI marked suitable for water cooler of any make/ type/ capacity including fixing accessories and making connection etc complete all as specified and directed by Engineer-in-Charge.
M&L for repairing to base/stand of water cooler of any make/type/capacity including welding of MS/GI sheet 16 SWG of suitable size to fill up rusted patches, grinding and applying base material for smooth surface and applying two coats of synthetic enameled spray paint of existing colour over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for scraping of old paint / rust etc by wire brush from body of water cooler of any make/type/capacity and applying base material for smooth surface and applying two coats of synthetic enameled spray paint over one coat of primer after denting etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for capacitor 4.00 Mfd for water cooler and desert cooler fan motor complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of water cooler body 40/80 ltr/hr capacity including fan motor, running capacitor, starting capacitor, evaporator coil, condensor coil, water tank, thermostate switch and all electrical connections complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of starting relay/ overload protector suitable for water cooler of any size/ type as per site requirement complete all as specified and directed by Engineer-in-Charge.
Taking out compressor sealed unit from deep freezer any capacity and make including removal of unserviceable parts/ spares, such as over load protector, strainer capillary tube etc complete all as specified and directed by Engineer-in charge.
M&L for replacement of unserviceable sealed unit (compressor) with new sealed unit (compressor) for deep freezer capacity 210/ 320/ 350/ 425 ltres, including vacuuming the system, supply and charging Gas at rated pressure, detection of leakage etc., brazing and testing to achieve proper cooling effect complete all as specified and directed.
M&L for leak detection by nitrogen pressure test in refrigerant system of deep freezer of any make/type/ capacity, by cutting, brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required quantity to achieve desire cooling including installation at site, testing of water cooler on full load for 24 hours continuously complete all as specified an directed. (Note:- Supply of additional gas required will measured & paid separately under relevant item).
S&F in replacement of thermostat suitable for deep freezer 210/ 320/ 350/ 425 ltrs capacity all as specified directed by Engineer- in-Charge .
S&F in replacement starting relay of deep freezer of different make and capacity 210/ 320/ 350/ 425 ltrs complete all as specified and directed.
S&F in replacement of fan motor for deep freezer 210/ 320/ 350/ 425 Hrs capacity complete as per existing make all as specified and directed .
S&F in replacement of toughened fibre body with glass wool/ foam insulation including top cover suitable for 210/ 320/ 350/ 425 ltr capacity deep freezer body including copper cooling coil of specified dia and length for smooth cooling complete all as specified and directed.
S&F in replacment of condensing coil for 210/ 320/ 350/ 425 ltr capacity deep freezer all as specified and directed.
Repairs to voltage stabilizer of any make, single phase with input voltage 135 - 190 V and out put voltage 200-240 volt, capacity 5 KVA by dismantling and taking out burnt main transformer and rewinding with super enamelled copper wire of suitable size including varnishing and insulation material etc.complete all as specified and directed
All as per item No- 315 above but for capacity 03 KVA complete all as specified and directed.
All as per item No- 315 abovee but for capacity 01 to 02 KVA complete all as specified and directed.
S&F in replacement of old voltmeter 0-300 volt range complete all as specified and directed by the Engineer-inCharge.
S&F in replacement of old analog type AC ammeter 0-100 amp range complete all as specified and directed by the Engineer-in-Charge.
S&F in replacement of indicator lamp neon type green/ red etc complete all as specified and directed by the Engineer-in-
S&F in replacement of relay 24 volt, 25 Amps, ISI marked suitable for voltage stabilizer of any type/ make / capacity etc complete all as specified and directed by the Engineer-inCharge.
S&F in replacement of electronic circuit ISI marked suitable for voltage stabilizer of any type/make/capacity etc complete all as specified and directed by the Engineer-in-Charge.
S&F of voltage stabilizer, copper wound of 5 KVA capacity digital display type having I/P correction range of 140-280 volt complete all as specified and directed by Engineer-in-Charge. Note : - Old unsv voltage stabilizer will be deposited to MES store yard.
S&F of voltage stabilizer, copper wound of 3 KVA capacity digital display type having I/P correction range of 140-280 volt complete all as specified and directed by Engineer-in-Charge Note : - Old unsv voltage stabilizer will be deposited to MES store yard.
S&F of voltage stabilizer, copper wound of 1 KVA capacity digital display type having I/P correction range of 140-280 volt complete all as specified and directed by Engineer-in-Charge Note : - Old unsv voltage stabilizer will be deposited to MES store yard.
M/S KALSI ENGINEERS AND CONTRACTORS (BID ID -3377238)
M/s Rahat Traders (BID ID -3377315)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .