Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹1.9 L+₹768 (0.40%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹1.9 L+₹1,390 (0.72%)Rejected-Finance VILL PO URA BURDWAN | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | BURDWAN REFRIGARATION SERVICE L2 | S.S. ELECTRICAL ENTERPRISE L1 | ANANTA ELECTRICAL ENGG CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00 | Part: A (Electrical Installation Work):
Supply & Fixing 240 V, 20 A Piano key type switch (Make - Anchor) on sheet metal switch board incl. S&F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required | 2 | Nos. | 240 ₹480 | 235 ₹470 Lowest | 237 ₹474 |
| 2.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Havells/Gloster/Polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision/Polycab make, HMS/MMS type) incl. necy. fittings as required
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 70 | Mtr. | 170 ₹11,900 Lowest | 170 ₹11,900 Lowest | 172 ₹12,040 |
| 3.00 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 8 | Set | 25 ₹200 | 23 ₹184 Lowest | 23 ₹184 Lowest |
| 4.00 | S&F 250V 25A Timer controller for AC machine in SS double door (IP 42/43) 2+10-way DB enclosure (Make:- L&T/Schnider/ABB Elegance) with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :-
i) 10kA, C-Curve, 240V, 25A DPMCB (LT/Schnider/ABB Elegance)- 1No
ii) 24 Hr programmable Digital Timer (LT make cat no 67DDT0) - 1 No
iii) 3 pole power contractor (LT make cat no MNX 22/230V) with 1 NO +1 NC additional contact block -- 2 sets
iv) 2 Moduler AC motor stater (Make:- Legrand/Myrius) - 1 No.
v) 2 Module plate with cover (Make :- Legrand/Myrius) -- 1 No
vi) 20A Auto-Off-Bipass SPDT toggle switch (Approved/reputed make)- 2 Nos.
vii) 10A SPST Moduler type switch (Make :- Legrand/Myrius) - 1 No.
viii)Outgoing connector make ELMAX (Approved/reputed make) - 2 Nos
(Single phase Twin timer) | 1 | Set | 9,950 ₹9,950 | 9,850 ₹9,850 Lowest | 10,000 ₹10,000 |
| 5.00 | Part: B (SITC of Airconditioning System):
SITC of 2.0 Tr capacity type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 No. Rotary compressor, 1 no. IDU of rated power supply -230V-1ph-50Hz., 1 no. ODU of rated power supply - 230V, 1ph, 50Hz. Air-flow/per IDU:- 800CFM. (Make: O General/Mitshubishi Electric/or equivalent) | 2 | Nos. | 69,920 ₹1,39,840 | 69,850 ₹1,39,700 Lowest | 69,968 ₹1,39,936 |
| 6.00 | Supply, fabrication & fixing of 2 Nos. M.S Equal Angle of 6mm thick of Size (50mm X 50mm) of 1 m length for making platform for installation of outdoor unit of 2.0 Tr Split Air Conditioner incl. drilling 2 nos hole in each channel including making necessary guarding arrangement of outdoor unit as per site condition as per direction of EIC. | 1 | Item | 4,892 ₹4,892 | 4,800 ₹4,800 Lowest | 4,925 ₹4,925 |
| 7.00Supply & fixing of HVAC grade copper pipe of following sizes for liquid and gas line between ODU and IDU (Make - Ryoku/Nippon):- | ||||||
| 7.01 | (a) 5/8" (gas line). | 20 | Mtrs | 482 ₹9,640 | 480 ₹9,600 Lowest | 485 ₹9,700 |
| 7.02 | (b) 1/4" (liquid line). | 20 | Mtrs | 255 ₹5,100 | 250 ₹5,000 Lowest | 265 ₹5,300 |
| 8.00Supply & fixing of Nitril Rubber insulation for refrigerant copper pipe minimum thickness 9 mm. incl. all accessories as per direction of EIC. (Make - Supreme/Aroflex):- | ||||||
Tender Value
Refer Docs
EMD Value
₹4,100
Closing Date
7 Mar 2026, 3:00 pmClosed
AE(LR)_SSKM(H.)ESD_PWDte.
244 A.J.C. Bose Road
Urgent Requirement 2.0 Tr. Split AC Machine in BIRAC Office room, department of Endocrinology at 3rd floor of Ronald Ross Building
2026_WBPWD_1014875_1
WBPWD/SSKM(H.)ESD/NIQ-166 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,100
28 Jul 2026
25 Feb 2026
9 Mar 2026
28 Feb 2026
7 Mar 2026
28 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Part: A (Electrical Installation Work):
Supply & Fixing 240 V, 20 A Piano key type switch (Make - Anchor) on sheet metal switch board incl. S&F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required | 2 | Nos. | - | - |
| 2 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Havells/Gloster/Polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision/Polycab make, HMS/MMS type) incl. necy. fittings as required
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 70 | Mtr. | - | - |
| 3 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 8 | Set | - | - |
| 4 | S&F 250V 25A Timer controller for AC machine in SS double door (IP 42/43) 2+10-way DB enclosure (Make:- L&T/Schnider/ABB Elegance) with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :-
i) 10kA, C-Curve, 240V, 25A DPMCB (LT/Schnider/ABB Elegance)- 1No
ii) 24 Hr programmable Digital Timer (LT make cat no 67DDT0) - 1 No
iii) 3 pole power contractor (LT make cat no MNX 22/230V) with 1 NO +1 NC additional contact block -- 2 sets
iv) 2 Moduler AC motor stater (Make:- Legrand/Myrius) - 1 No.
v) 2 Module plate with cover (Make :- Legrand/Myrius) -- 1 No
vi) 20A Auto-Off-Bipass SPDT toggle switch (Approved/reputed make)- 2 Nos.
vii) 10A SPST Moduler type switch (Make :- Legrand/Myrius) - 1 No.
viii)Outgoing connector make ELMAX (Approved/reputed make) - 2 Nos
(Single phase Twin timer) | 1 | Set | - | - |
| 5 | Part: B (SITC of Airconditioning System):
SITC of 2.0 Tr capacity type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 No. Rotary compressor, 1 no. IDU of rated power supply -230V-1ph-50Hz., 1 no. ODU of rated power supply - 230V, 1ph, 50Hz. Air-flow/per IDU:- 800CFM. (Make: O General/Mitshubishi Electric/or equivalent) | 2 | Nos. | - | - |
| 6 | Supply, fabrication & fixing of 2 Nos. M.S Equal Angle of 6mm thick of Size (50mm X 50mm) of 1 m length for making platform for installation of outdoor unit of 2.0 Tr Split Air Conditioner incl. drilling 2 nos hole in each channel including making necessary guarding arrangement of outdoor unit as per site condition as per direction of EIC. | 1 | Item | - | - |
| 7Supply & fixing of HVAC grade copper pipe of following sizes for liquid and gas line between ODU and IDU (Make - Ryoku/Nippon):- | |||||
| 7.01 | (a) 5/8" (gas line). | 20 | Mtrs | - | - |
| 7.02 | (b) 1/4" (liquid line). | 20 | Mtrs | - | - |
| 8Supply & fixing of Nitril Rubber insulation for refrigerant copper pipe minimum thickness 9 mm. incl. all accessories as per direction of EIC. (Make - Supreme/Aroflex):- | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
BOQ_2492655.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .