REP MAINT OF DG SETS 750 KVA WALK IN COOLER MORTUARY BODY CABINET SOLAR WATER HEATER SEWAGE PUMP HOUSE FIRE PUMP HOUSE FIRE ALARM SYSTEM AT MH BHOPAL AND REP MAINT OF LT CABLE OH CONDUCTOR LT PANEL AND APFC PANEL AT BAIRAGARH UNDER GE BHOPAL
2024_MES_636842_1
8267/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹95,400
Yes
3 May 2024
10 Jan 2024
12 Feb 2024
10 Jan 2024
10 Feb 2024
24 Jan 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down of Solar water heating system of 200 ltrs per day capacity from its position after disconnecting water connections, and re - fixing /reassembling in position after repair and testing, complete all as specified and as directed. Note:- (a) Rate quoted by the contractor deemed to be included making good of missing Nuts, Bolts and washers, unions, sockets, flanges, screws etc to make it full functional, (b) Descalling/desludging, cleaning and washing of solar panels, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and reassembling the panels including necessary welding of collector fins as required. (c) Painting to staging,s olar panel frames, hot water tank frame using one coat of synthetic enamel paint including necessary preparation of surfaces complete. (d) Any other materials/Parts need to be replaced by contractor and will be measured and paid seperately.
All as per item No. 01.00 here-in-brfore but 100 Litre per day capacity.
S&F in replacement of stainless steel, water heater tank, suitable for 100 Litre per day to match with existng SS tank specifications with all arrangements complete all as specified and directed Note: (i) Thickess of new tank to be matched with existing tank. (ii) The work should be executed at the top of 20m height building.
All as per item No. 03.00 here-in-brfore but 200 Litre per day capacity.
S&F solar energy collector panel made of aluminium body with 5mm thick toughened glass complete with copper fins of capacity 200 litres per day as per existing make complete all as specified & directed.
S&F Solar energy collector panel gasket made out of supirior quality rubber to make system air tight, dust and water proof complete of capacity 200 litres per day as per existing make complete all as specified & directed.
S&F compressed glass wool (insulation materials) 48mm thick between solar energy collector panel copper tubes frame and aluminium body panel including securing it on panel by means of necessary adhessive complete all as specified & directed.
S&F solar energy collector panel manifold 1.40 mtr long, made out of 20mm dia copper tube having 1 No MS flange, 74mm dia welded at each end duly drilled for Nuts, Bolts and washers as per existing make including welding of solar collector tubes with manifold complete all as specified & directed.
S&F in repair of rotational moulded, 3 layer HDPE water storage tank of 500 ltrs capacity (Cylindrical vertical with closed top) (IS 12701-1996) ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball including fixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed.
All as per item No. 9.00 here-in-brfore but 1000 capacity.
S & F in repairs 15mm bore GI tubing, medium grade, along with sockets, bends, tees and other fitting as required fixed to wall, floor, or ceiling with all fittings complete all as specified and diretced.
All as per item No. 11.00 here-in-brfore but 20 mm dia.
All as per item No. 11.00 here-in-brfore but 25 mm dia.
Supply and filling anti freezing liquid in 20 ltr, PVC can for solar water heater system complete all as specified and directed by Engr-in-Charge.
M&L for 3-layer PP-RPolypropylene random copolymer) concealed pipes SDR 7.4 (PN1.6), UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc of followings sizes :-
S & F in repairs toughened glass of size as per sample not less than 2 Sqm, 4mm thick of solar water heater rated panel of capacity 200 LPD complete all as specified and directed by Engr-in-Charge.
S&F for bib taps of 15 mm dia bore, cast copper alloy with chromium plated fancy type with capstan head, screwed down, screwed iron pipe, in repairs including taking down old one complete all as specified and as directed.
S&F stop valves of 15 mm dia bore, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends iron pipe or for unions and fixed complete all as spcified by Engr-in-Charge.
All as per item No. 18.00 here-in-brfore but 20 mm dia.
All as per item No. 18.00 here-in-brfore but 25 mm dia.
Supply & replacement thermostate suitable for 200/100 Ltr, Geyser, ISI marked complete all as specified & directed.
Supply and fixing of 2 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection including taking down complete all as directed by the Engineer-in-Charge.
Supply and fix in replacement sheet metal enclosures with socket plug top and MCB's with two pin and earth plug and socket complete with one single pole MCB, 240 V grade 20 Amp.
S&F in repairs PVC insulated FRLS cable 1100 volt, unsheathed with stranded copper conductor of 4 sqmm 3 core nominal cross section area complete all as specified and directed.
Repair & comprehensive maintenance of DG sets of any make of the following capacities which include replacement of worn out spares such as fuel filter, oil filter, lubricating oil hoses, V- belt, Oil pipes, fuel pipe, water pump, cut out and tightening of nut bolts, washers etc of DG sets complete all as specified and directed. Note :- Spares shall be mesured & paid separetely)
(a) 750 KVA capacity
(b) 10 KVA capacity
(c ) 15 KVA capacity
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 10 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 10 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 10 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 15 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 15 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 15 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
Supply only following spare parts for 10 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahindra complete all as specified and directed:-
(a) Head Gas Kit complete
(b) Fuel Filter complete
(c) Lubricating Oil Filter complete
(d) Hose Pipe Set complete
Supply only following spare parts for 750 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahindra complete all as specified and directed:-
(a) Head Gasket Kit complete
(b) Fuel Filter complete
(c ) Lubricating Oil Filter complete
(d) Hose Pipe Set complete
Supply only following spare parts for 15 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahindra complete all as specified and directed:-
(a) Head Gasket Kit complete
(b) Fuel Filter complete
(c) Lubricating Oil Filter complete
(d) Hose Pipe Set complete
Dismantling and taking down radiator assembly from engine of any capacity for repairs including de-scalling, bracing as necessitated to plug leakages and M & L for transporting of the radiator of capacity 750 KVA and repair/maintenance to the radiator fins with the help of cleaning coil solution and cleaning the radiator complete and repair to the leakage places by means of gas welding and including initial filling up coolant and re-fixing after repairs including replacement of worn out nut bolts, washers, etc; and testing complete all as specified and directed.(Note :- Coolant shall be measured & paid separetely)
Dismantling and removing fuel injection pump from DG set for repairs including re-calibration at authorised service centres, replacement of necessary spare parts such as delivery valves, plunger, 'O' ring, springs etc and refixing, testing complete all as specified and directed of the following capacity:-
(a) 750 KVA capacity
(b) 10 KVA capacity
Supply only Lubrication Oil 15 W 40 complete all as specified and directed. Make :- Castrol / Servo /HP
Supply only Lubrication Oil 20 W 40 complete all as specified and directed. Make :- Castrol / Servo /HP
Repair / Overhauling of self starter 12 / 24 Volt of any make / capacity including replacement of minor items such as carbon brushes, nuts, bolts etc; all as necessitated complete all as specified and directed. Note:- All additional spares as required will be measured and paid seperately.
Supply only following spares for self starter 12 / 24 V complete all as specified and directed :-
(a) Field coil
(b) Armature
(c ) Clutch assembly
Supply only battery lead, copper conductor 25 Sq mm, multi stranded, PVC insulated with suitable terminals at both ends complete all as specified and directed.
Supply only Fan belts as per sample for DG sets of capacity:-
(a) 750 KVA capacity
(b) 10 KVA capacity
Supply only water pump suitable for DG sets of following capacity:-
(a) 750KVA capacity
(b) 10 KVA capacity
Supply only Control Safety (Lub oil) for 750 KVA DG Set complete all as specified and directed.
Supply only Control Safety (Water) Part No. for 750 KVA DG set complete all as specified and directed.
Replacement of S.D. Valve for 750 KVA DG set complete all as specified and directed.
Supply only Coolant additive concentrate pack of 10 Ltr suitable for DG Set complete all as specified and directed.
Supply only Distilled water in 5 ltr PVC Container complete all as specified and directed.
Supply only air filter outer & inner element for 750 KVA DG set as per sample complete all as specified and directed.
Supply only air filter outer & inner element for 10 KVA DG set as per sample complete all as specified and directed.
Supply only air filter outer & inner element for 15 KVA DG set as per sample complete all as specified and directed.
S&F in replacement On load changeover switches, 4 pole, 200 Amp manual changeover in open execution complete all as specified and directed.
S&F in replacement On load changeover switches, 4 pole, 100 Amp manual changeover in open execution complete all as specified and directed.
M&L in replacement maintenance free lead acid battery 12 volt, 180 AH with minium 36 months warranty of complete all as specified and directed.
M&L in replacement maintenance free lead acid battery 12 volt, 92 AH with minium 36 months warranty of complete all as specified and directed.
S&F in replacement of complete Engine controller HMI remote unit display power command with mother board for 750 KVA DG Set complete all as speified and directed.
Servicing of DG Sets of any capacity of 50 KVA Make : Kirloskar,Ruston & Commins at 250 running hours or 6 months whichever is earlier including replacement of defective/warn out parts by new spares such as filters, gaskets, V-Belts Engine oil, rubber hoses, worm drive, clamps, nuts & bolts, KIT Complete. Note- Spare parts will be measured and paid separetely in relavent items.
Supply only of the following in the repair for 50 KVA DG Set
(a) Element fuel filter
(b) Element oil filter
(c) Kit supper by pass filter Element
(d) Plug pipe Cat No -S-995
(e) Plug pipe Cat No -S-915 A
(f) Plug pipe Cat No - 67688
(g) Hose flexible
(h) Control Safety ( Water)
(j) Copping suitable for existing DG Set with Lubjoy rubber coppling
Servicing of DG Sets of any capacity from upto 320 KVA Make : Commins at 250 running hours or 6 months whichever is earlier including replacement of defective/warnout parts by new spares such as filters,gaskets, V-Belts Engine oil, rubber hoses, worn drive, clamps, nuts & bolts, KIT Complete. Note-Spare parts will be measured and paid separetely in relavent items.
Supply only of the following in the repair for 320 KVA DG Set
(a) Element Lub oil Cat No - 3238204
(b) Element Fuel filter Cat No - 3238493
(c) Kit supper by pass filter Element Cat No - 3879488
(d) Belt V Cat No - 3001600
(e) Belt V Cat No - 178567
(f) Hose flexible Cat No - AK-5041 SS
(g) Hose flexible Cat No - AK-6045 SS
(h) Hose flexible Cat No - AK-6065 SS
(j) Hose flexible Cat No - AK-10075 MS
(k) Hose flexible Cat No - AK-10024 SS
(l) Hose flexible Cat No - AK-10030 SS
(m) Hose flexible Cat No - AK-6054 ST
Supply & fix in repair, diesel filter suitable for 50 KVA and upto 110 KVA DG Set
Supply & fix in repair Engine Oil filter suitable for 50 KVA and upto 110 KVA of DG Set Cat No - 126037012
Supply & fix in repair Air cleaner elements inner and outer for 50 KVA to 200 KVA DG set of Make - Cummins
Supply & fix in repair Air cleaner elements inner and outer for 320 KVA, DG set of Make - Cummins, Cat No - 3226018,3226019
Supply& fix in repair Battery terminal heavy duty brass with nut & bolts complete.
Supply & fix in repair Petrolium jelly in 1 Kg plastic sealed container
Supply& fix in repair Battery lead for 180 AH,12 V battery copper conductor PVC multistranded 1.5 mtr long duly fixed with terminals and lugs.
Supply & fix in repair Battery link lead with battery terminal of +/- terminal 0.3 mtr long.
Supply& fix in repair Oil pressure gauge suitable for YDA series DG set.
Rapair /overhauling & removel of leakage from radiator & refixing it duly repaired, cleaning descalling, welding brazing etc. incl replacement of rubber hoses and clips etc. Complete all respect of the following capacities of DG sets :-
(a) 100 KVA to 320 KVA
(b) 10 KVA to 100 KVA
Rapair / overhauling of self starter 10 KVA -320 KVA incl. Replacement of carbon brusses, bearing, bushes, rewinding of armature and fild etc. and warnishing Complete all as directed for the 12V. Make :- Lucas
M&L for spray painting of DG Sets, Alternator, Panel, Diesel tank and Base frame etc. with one coat of synthetic enameld paint as per MES colour code after cleaning of old paint surface for paint etc. complete all as directed by EIC for the following capacity DG Set.
(a) 110 KVA to 200 KVA
(c) 10 KVA to 100 KVA
S & F heat proof asbestos rope 12mm dia in engine exhaust pipe including dismantling of worn out Asbestos rope and minor welding / tightaning in leakage exhaust complete all as directed conferming to IS specification fire proof / flame proof.
Calibration and over hauling FTP or PT pump of 10 KVA to 50 KVA DG set with replacement of the following parts :- (a) Delivery valve - 06 Nos (b) Bearing - 02 Nos (c) Elements - 06 Nos (d) Main spring - 06 Nos (e) Gasket sets (f) Seal (g) Cap Screw (h) 'O' ring - 01 set (j) Governer assembly - 01 set (k) Screen filter
Dismantling of unserviceable self starter of capacity 12/24 Volts from engine and shifting to civil workshop for repair / overhauling of the self starter by rewinding of one field coil, repair and rewinding of armature and return to the existing place after repairing.
M&L for earthing complete with galvanised iron steel earth plate electrode 60cm×60cm× 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron or steel earth wire protected by GI iron pipe 15mm bore, medium grade and connected to main switch board as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC over slab 30cm x 30cm x 10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal in coke and salt in alternate lages, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES schedule part-I and testing after completion all as specified and directed.
Supply only Rubber Coupling for DG Sets upto 100 KVA to 750 KVA
Repairing of diesel engine generator set, capacity from 10 KVA to 110 KVA and dismatling of the engine strip opening etc. (a) Valve seat cutting and fixing of the valve guide. (b) Griding and polishing of crank shaft complete. (c) Fixing of the cylinder liner. (d) Cylinder block line bearing and threading of existing holes. (e) Fixing of the piston ring complete. (f) Repair to cylinder head, injector sleeves including fixing and testing complete. Note :- All spare parts for replacement/fixing shall be supplied under relevent items.
S & F Change over switch 4 Pole 250 Amps, 50 KA complete all as specified and directed.
S & F Change over switch 4 Pole 450 Amps, 50 KA complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out all as specified and directed.
Returning, filling in including spreading, leveling and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note:- Punned thickness shall be measured & paid.
Supplying and laying Class LV, Type I, flat, size 250mm x 150mm x 40mmfor cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
M&L for tank cleaning of DG set of capacity from 10 KVA to 100KVA complete all as specified and directed by Engr-in-Charge.
M&L for tank cleaning for DG set of capacity from 110 KVA to 750KVA complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for pole foundation, cable trench, etc and getting out in soft/hard soil/rock complete all as specified and directed.
Dismantling cross arms, bracings, supports, clamps and back plates from existing poles (other than dismantled poles) and pole structures complete.
Fixing only Cross arms, bracing, supports, clamps and back plate, obtained from demolition with & including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall complete all as specified and directed
Repair of Earthing pit cover with fixing of funnel of required size in PCC 1:2:4 type B1 and RCC cover with frame as shown in electrical plate No-03 of SSR Part-I 2020 all as directed & specified by Engr-in-Charge.
M&L for painting of steel pole (swan neck type or straight type) up to 9 mtr height with cross arms, clamp of any length and shape for LT overhead line/street light with two coats of aluminium paint after scratching out old paint, cleaning the existing surface rust free, preparation of the surface including marking pole numbers in a 20 cm dia yellow circle with number writing with black synthetic paint & painting strips in alternate from bottom to top with three strips of black synthetic paint & two strips of white fluorescent paint (up to 1.5 mtr height) throughout the circumference of pole ( width of each strip shall be of 30 cm), including one coat of lime wash on PCC copping of pole complete all as specified and directed.
M&L for Painting the cross arms, clamps etc. of LT PCC poles of 9 Mtrs height after preparation of surface, making the surface smooth with two coat of aluminium paint & providing alternative bend of 30 cm width ( 3 black and 2 white) from bottom of pole to 1.5 Mtr Height with two coat painting with synthetic enameled paint , writing of pole numbers in yellow circle 15 cm with black paint on poles complete all as specified and directed.
Supply, spreading and levelling 40 mm to 80 mm size graded crushed coarse aggregate around transformer plinth/four pole and two pole structures all as specified and directed.
M&L for maintenance and cleaning of surrounding area of sub station near LT panels, transformer etc by cutting seasonal grass, bushes etc, by employing skilled mazdoor including using own T&P as required to do the job and taking all precaution while men on working in sub station being dange zone.
Cutting & trimming tree branches along HT/LT over head lines after arranging shut down and by taking all precautions while working on lines, etc including all T & P required for the purpose and removal of rubbish complete all as specified and directed by Engineer-in-Charge. Note:- Number of trees & their branches cut under this item shall be entered in MB with location.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including filling at road cuttings or making pillars for supporting pipe including necessary form work complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed. including necessary form work complete all as specified and directed.
M&L for tightening and re stringing of existing ACSR over head conductor of any size/type on LT over head line with the help of rope/line wise and tighting the conductor to permissiable sag with and including new aluminium tape/aluminium wire complete all as specified and as directed.
Dismantling of ACSR conductor of any type and size complete all as specified and directed.
S&F aluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete all as specified and directed. (Type of new conductors:- weasel/ rabbit/ Mink) Note : Measurements for the purpose of payments shall be made by measuring horinzontal distance between centers of two adjacent poles and adding 3% extra for sag, joints, jumpers etc.)
S&F in replacemnt cradle guard hexagonal/rectangular, fabricated with galvanized steel wire 3.15mm dia complete all as specified and directed.
S&F Steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC, numbering of poles in 100mm diameter yellow circle with black paint including 15 cm wide alternate black & yellow bands upto 1.5m height from ground level, type 410-SP-31 (9 meter long) including dismantling after disconnecting existing damaged LT PCC or steel poles, any length long and demolition of cement concrete complete. Note - Excavation, earth work and PCC shall be measured and paid separately.
S&F in repair MCCB, 630 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type with adjustable overload setting and adjustable short circuit setting and ground fault , including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB complete all as specified and directed.
S&F in repair MCCB, 400 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type with adjustable overload setting and adjustable short circuit setting and protection against ground fault , including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB complete all as specified and directed.
S&F in repair MCCB, 250 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type with adjustable overload setting and adjustable short circuit setting and protection against Earth protection leakage fault , including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed.
S&F in repair MCCB, 200 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type with adjustable overload setting and adjustable short circuit setting and Earth protection leakage fault module, including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed.
S&F in repair MCCB, 160 Amp, 3 Pole, 16 KA, 415 V, thermal magnetic release type with adjustable overload setting and adjustable short circuit setting, with thermal release range 125-160 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed.
S&F in repair MCCB, 100 Amp, 3 Pole, 16 KA, 415 V, thermal magnetic release typewith adjustable overload setting and adjustable short circuit setting , with thermal release range 100-125 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed.
S&F in repair MCCB, 63 Amp, 4 Pole, 16 KA, 415 V, thermal magnetic release typewith adjustable overload setting and adjustable short circuit setting , with thermal release including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed.
Dismantling of LT insulator of any type and any size complete all as specified and directed
S&F Pin type, polymer insulator, 100mm height, 65 mm diameter for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, complete all as specified and directed.
S&F Shackle type, polymer insulators 90mm diameter and 75mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 12mm diameter insulator bolts, washers & nuts complete all as specified and directed.
S&F in repairs LED indication lamps (RGY) (set of three) complete all as specified and as directed.
M&L in repair of LT cable straight through joint/ End joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 16 Sqmm to 35 Sqmm x 3.5 core complete all as specified and directed. Make: Denson/3M/M Seal.
M&L in repair of LT cable straight through joint/ End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 50 Sqmm to 70 Sqmm x 3.5 core complete all as specified and directed.Make: Denson/3M/M Seal.
M&L in repair of LT cable straight through joint/ End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 95 Sqmm to 120 Sqmm x 3.5 core complete all as specified and directed.Make: Denson/3M/M Seal.
M&L in repair of LT cable straight through joint/ End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 150 Sqmm to 185 Sqmm x 3.5 core complete all as specified and directed.Make: Denson/3M/M Seal.
M&L in repair of LT cable straight through joint/End Joint heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 240 Sqmm to 400 Sqmm x 3.5 core complete all as specified and directed.Make: Denson/3M/M Seal.
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 10 Sqmm nominal cross section x 2 core complete all as specified and directed.
All as per item No. 128.00 above but Size 16 Sqmm X 4 core complete all as specified and directed.
All as per item No. 128.00 above but Size 25 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 35 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 50 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 70 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 95 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 120 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 150 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 185 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 240 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 300 Sqmm X 3.5 core complete all as specified and directed.
All as per item No. 128.00 above but Size 630 Sqmm X 3.5 core complete all as specified and directed.
S&F 40mm GI tubing, light grade, with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut, bolt and washer including taking down old rusted pipe complete all as specified and directed.
All as per item No. 141.00 above but Size 50 mm complete all as specified and directed.
All as per item No. 141.00 above but Size 80 mm complete all as specified and directed.
All as per item No. 141.00 above but Size 100 mm complete all as specified and directed.
S&F in repairs aluminium lugs with brass thimble stud of any type for the following complete all as specified and directed:-
(a) 16 sqmm
(b) 25 sqmm
(c ) 50 sqmm
(d) 70 sqmm
(e) 95 sqmm
(f) 120 sqmm
(g) 150 sqmm
(h) 240 sqmm
(j) 300 sqmm
S & F brass thimble stud of required size complete all as specified and directed by Engr-in-Charge.
M&L for painting of extisting out door LT cubical panel of size 1700 X1500 X 250 mm from outer side with two coats of existing powder coated paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, complete all as specified and directed.
M&L for dismantling of overhead conductor of any size and type from any type of pole and lowering down safely (to avoid conductor to be damaged during tree cutting of tall branches or for replacement of pole) and refixing and tightening and stringing of existing conductor after cutting of tree on pole with the help of rope/line wise and tighting the conductor to permissiable sag with and including new aluminium tape/aluminium wire complete all as specified and as directed. (each conductor to be measured seperatly, tree cutting to be paid seperately under relevent item).
M&L for servicing/repairing of capacitor panel, any type and size upto 150 KVAR for making them functional, removing and cleaning of dust, checking control wiring and connections, replacement of any damaged control wire, checking capacitors, tightening of all electrical connections and hardware, checking of metering devices, relays, etc, replacement of defective unserviceable parts to make the panel fuly functional complete all as specified and all as directed by Engineer-in-charge. Note :- Spares required shall be measured and paid separately.
Supply only Heavy duty, resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP-20 with over pressure disconnector, dielectric -MPP of 15 KVAR complete all as specified and directed.
Supply only Heavy duty, resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP-20 with over pressure disconnector, dielectric -MPP of 10 KVAR complete all as specified and directed.
Supply only Heavy duty, resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP-20 with over pressure disconnector, dielectric -MPP of 5 KVAR complete all as specified and directed.
Supply only power factor controller of 8 step controller, complete all as specified and directed.
Supply only power factor controller of 6 step controller, complete all as specified and directed.
Supply only MCB SP, 6 to 32 Amp, 240 V, 10 KA "C" curve, IP 20, Conf to IS, complete all as specified and directed.
Supply only control coil 230 V suitable for 4 Pole contactor, complete all as specified and directed.
Supply only add on auxiliary contact block front mounting, 2 NO + 2 NC for 4 Pole contactor 25 Amp, complete all as specified and directed.
Supply , fabricating and fixing of LT panel door made up of CRCA sheet min 3.15 mm thick duly painted with powder coated Siemens Grey paint, factory made, door of size suitable for existing LT panel and fixed , welded on site with panel body with havey duty hinges, with locking arrangement complete all as specified and directed.
Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces all as per existing complete all as specified and directed. Note : GI pipe shall be measured & paid separately.
M&L required for jointing of LT cable by straight through cable joint/cable end termination of various sizes complete all as specified and directed. Note: Cable straight through joint provided by Dept.
Deduct Schedule of credit (calculation will be done off line) Rs. 143082.00
PRAGATI ELECTRICALS AND ELECTRONICS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .