| 1 | L1₹46.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹47.5 L+₹89,795 (1.93%)Rejected-Finance PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹50.6 L+₹4.0 L (8.53%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹53.5 L+₹6.9 L (14.7%)Rejected-Finance 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L4 | Rejected-Finance Being L4 bidder | |
| 5 | Rejected-Technical 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | - | Rejected-Technical Rejected being two class the eligible class |
| Sl No | Description | Qty | Unit | M/s.G.KRISHNA RAO L1 | S.M.CONSTRUCTIONS L4 | RANA ENTERPRISES L3 | SMART ENERGY SOLUTIONS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | SCH 'A' PART-I : B/R PORTION
Dismantling of plain or corrugated steel sheeting any gauge any thickness incl nainital or similar pattern roof covering complete all as specified and directed. | 890 | Sqm | 45 ₹40,050 | 90 ₹80,100 | 20 ₹17,800 Lowest | 20 ₹17,800 Lowest |
| 2.00 | Dismantling timber scantlings of framed work of 40 Sqcm and over in section, in any position complete all as specified and directed. | 7 | Cum | 1,000 ₹7,000 | 250 ₹1,750 | 150 ₹1,050 | 30 ₹210 Lowest |
| 3.00 | Dismantling of timber rails, posts, rafters, purlins, etc under 40 Sqcm in section complete all as specified and directed. | 700 | RM | 25 ₹17,500 | 35 ₹24,500 | 20 ₹14,000 Lowest | 28 ₹19,600 |
| 4.00 | Dismantling of wall and ceiling boards (fibre pulp,insulation etc) or insulation boards/slabs any thickness incl cover fillets complete all as specified and directed. | 660 | Sqm | 30 ₹19,800 | 20 ₹13,200 | 15 ₹9,900 Lowest | 20 ₹13,200 |
| 5.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. | 10 | Qtl | 680 ₹6,800 | 350 ₹3,500 Lowest | 850 ₹8,500 | 850 ₹8,500 |
| 6.00 | S & F rolled mild steel in Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.Fe-410-W(Gde-E-250) quality-B complete all as specified and directed. | 1,000 | Kg | 180 ₹1,80,000 | 155 ₹1,55,000 | 140 ₹1,40,000 | 130 ₹1,30,000 Lowest |
| 7.00 | M&L for prepraration of new surfaces of steel /iron of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed. | 150 | Sqm | 100 ₹15,000 | 95 ₹14,250 | 70 ₹10,500 Lowest | 105 ₹15,750 |
| 8.00 | M&L for prepraration of old decorated surfaces of steel /iron of any description (Plain or corrugated) exc 10 cm width or girth and applying one coat of aluminium paint at hanger wall and roof (Internal) complete all as specified and directed. | 400 | Sqm | 90 ₹36,000 | 80 ₹32,000 | 70 ₹28,000 | 65 ₹26,000 Lowest |
| 9.00 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50-0.53 mm thick of any colour having tensile strength of 550 Mpa with hot dip mettalic coating of aluminium alloy (galvalume 150 gms/sqm total of both sides, AZ 150 of BMT 0.45mm measuring 0.53mm thick with finish coat as per ASTM A-792 or AS 1392) and wall sheet coated with 25 micron thick paint on top and back coating on sheet shall be 10 micron as in roof covering/ cladding to wall, fixed with self tapping screwes as specified and also surface should be dust free. (alloy of 55% aluminium, 43.5% zinc,1.5% silicon) complete all as specified and directed. MAKE: TATA BLUESCOPE STEEL Colorbond XRW steel OR EQUIVALENT in make as mentioned in Appx 'A' to PS. (Life prior to corrosion to perforation by weathering in the natural elements of 20 years from date of manufracturer) | 840 | Sqm | 950 ₹7,98,000 Lowest | 1,074 ₹9,02,160 | 950 ₹7,98,000 Lowest | 1,070 ₹8,98,800 |
| 10.00 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50-0.53 mm thick of any colour having tensile strength of 550 Mpa with hot dip mettalic coating of aluminium alloy (galvalume 150 gms/sqm total of both sides, AZ 150 of BMT 0.45mm measuring 0.53mm thick with finish coat as per ASTM A-792 or AS 1392) and wall sheet coated with 25 micron thick paint on top and back coating on sheet shall be 10 micron as in ridge of roof, fixed with self tapping screwes as specified and also surface should be dust free. (alloy of 55% aluminium, 43.5% zinc,1.5% silicon). MAKE: TATA BLUESCOPE STEEL Colorbond XRW steel OR EQUIVALENT in make as mentioned in Appx 'A' to PS. (Life prior to corrosion to perforation by weathering in the natural elements of 20 years from date of manufracturer) | 45 | Sqm | 920 ₹41,400 Lowest | 1,024 ₹46,080 | 1,200 ₹54,000 | 1,070 ₹48,150 |
Tender Value
₹56.8 L
EMD Value
₹1.1 L
Closing Date
15 Jul 2025, 6:00 pmClosed
Shri Himanshu IDSE EE
GE (I)(CG) Bhubaneswar, Military Engineer Services, Near School Integral Education, Campus-2, Coast Guard Complex, Pallaspalli, Bhubaneswar-751 020 (Odisha)
SPECIAL REPAIR AND REPLACEMENT OF WORKS IN JUMPERS BARRACK NO 3 AND 4 AT DET PTS VIKAS AT ARC CHARBATIA
2025_MES_710646_2
8584/BBSR/05/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Charbatia
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (I) (CG) Bhubaneswar
₹1.1 L
Yes
18 Aug 2025
21 Jun 2025
17 Jul 2025
21 Jun 2025
15 Jul 2025
1 Jul 2025
Amount
SCH 'A' PART-I : B/R PORTION Dismantling of plain or corrugated steel sheeting any gauge any thickness incl nainital or similar pattern roof covering complete all as specified and directed.
Dismantling timber scantlings of framed work of 40 Sqcm and over in section, in any position complete all as specified and directed.
Dismantling of timber rails, posts, rafters, purlins, etc under 40 Sqcm in section complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre pulp,insulation etc) or insulation boards/slabs any thickness incl cover fillets complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F rolled mild steel in Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.Fe-410-W(Gde-E-250) quality-B complete all as specified and directed.
M&L for prepraration of new surfaces of steel /iron of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
M&L for prepraration of old decorated surfaces of steel /iron of any description (Plain or corrugated) exc 10 cm width or girth and applying one coat of aluminium paint at hanger wall and roof (Internal) complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50-0.53 mm thick of any colour having tensile strength of 550 Mpa with hot dip mettalic coating of aluminium alloy (galvalume 150 gms/sqm total of both sides, AZ 150 of BMT 0.45mm measuring 0.53mm thick with finish coat as per ASTM A-792 or AS 1392) and wall sheet coated with 25 micron thick paint on top and back coating on sheet shall be 10 micron as in roof covering/ cladding to wall, fixed with self tapping screwes as specified and also surface should be dust free. (alloy of 55% aluminium, 43.5% zinc,1.5% silicon) complete all as specified and directed. MAKE: TATA BLUESCOPE STEEL Colorbond XRW steel OR EQUIVALENT in make as mentioned in Appx 'A' to PS. (Life prior to corrosion to perforation by weathering in the natural elements of 20 years from date of manufracturer)
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50-0.53 mm thick of any colour having tensile strength of 550 Mpa with hot dip mettalic coating of aluminium alloy (galvalume 150 gms/sqm total of both sides, AZ 150 of BMT 0.45mm measuring 0.53mm thick with finish coat as per ASTM A-792 or AS 1392) and wall sheet coated with 25 micron thick paint on top and back coating on sheet shall be 10 micron as in ridge of roof, fixed with self tapping screwes as specified and also surface should be dust free. (alloy of 55% aluminium, 43.5% zinc,1.5% silicon). MAKE: TATA BLUESCOPE STEEL Colorbond XRW steel OR EQUIVALENT in make as mentioned in Appx 'A' to PS. (Life prior to corrosion to perforation by weathering in the natural elements of 20 years from date of manufracturer)
M&L Asbestos cement plain building boards 4mm thick, fixed to Aluminium sections with screws complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for celling Size of grid 605X605mm. (i) Aluminium sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285. (ii) The snap grid consist of anodized aluminium main/cross tee of size as indicated.(b) Workmanship:- (i) Snap grid frame work shall be fixed to ceiling with supporting hanger consisting of 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as manufacturer’s instruction.(ii) The main and cross tees shall be jointed at junction/crossings with anodized aluminium angle bracket of size as indicated, if not indicated it shall be 15mmxl5mmx1.5mm, weighing 0.12 Kg per running metre, fixed with sutiable mild steel, bolts nuts and washers, all as per manufacturer’s instructions. (iii) The snap grid (main/cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size as indicated, if not indicated it shall be 40mmx25mmx2mm, weighing 0.36 Kg per running metre. (iv) Size of the snap grid shall be as indicated. (v) PVC protected sheeting shall be used to avoid scratches, damage to the framework while fixing to ceiling. complete all as specified and directed.
Demolition of brick or stone / boulders masonary work built in cement mortar including all quins, arches, pillars etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and as directed.
M&L brick work with sub class 'B' bricks (old size bricks) straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
M&L 20 mm thick cement plaster in CM (1:4) in two layers (8mm thick with approved water proofing compound over backing layer of 12 mm thick )on fair faces of brick work incl finished even and smooth without using extra cement complete all as specified and directed. Note : WPC will be measured and paid spearately as supply only under respective item of this Sch.
Supply only integral water proofing compound complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion including one coats of primer complete all as specified and directed.
Material and labour for preparation of old treated surface of wall by complete removal of existing treatment and applying two or more coat plaster of paris putty to obtain the surface even and smooth and applying two coat of oil bound distemper complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Material & Labour for complete removal of existing treatment of old surfcaes of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. Note: (i) Complete removal of existing treatment of old surfcaes are to be carried out by means of mechanical process, contractors are deemed to be qouted the rate accordingly.
Taking down chowkats or frames with shutter (without taking off shutters from the frame exc 1.50 qm and n exc 4.0 Sqm each incl removing to store complete all as specified and directed.
M&L for pressed mild steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size 125x60 mm of thickness 1.25mm complete all as specified and directed.
M&L Black bituminous paint of Surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified and directed.
M&L for Cement concret 1:2:4 type B0 (using 12.5mm graded aggregate for filling of steel frame and fix windows and doors hold fasts etc complete all as specified and directed.
S&F of II class hard wood Plain, framed, panelled shutters (any number of panels) 30mm thick, with panels of timber flat on both sides (feather edged), or of veneered particle board 9mm thick particles medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed
S&F of II class hard wood 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
M & L two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces incl preparation of new wooden surfaces complete all as specified and directed.
S&F mild Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
S&F mild Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F mild Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L Double charged Virified Ceramic tiles 8 to10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L 40 mm thick Cement concrete type B-0 1:2:4 using 12.5mm graded stone aggregate as in floor complete all as specified and directed.
M&L Double charged Virified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, fixed in walls as dado/skrtings, set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed.
M&L Anti-Termite Treatment Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L ANTI-TERMITE TREATMENT of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L ANTI-TERMITE TREATMENT Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre includingdrilling and plugging holes etc. in apron complete all as specified and directed.
S & F 100 mm long butt hinges MS medium weight cold rolled complete all as specified and directed.
S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and avg width of aperture 1.40 mm and fixed with stainless steel wire stapples complete all as specified and directed.
Demolition of plain cement concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) Type C-2 using 20 mm graded stone aggregate as in floor/plinth protection/footpath even and smooth using extra cement complete all as specified and directed.
M & L for Plain cement concrete , type B-1, 1:2:4 (using 20 mm graded crushed stone aggregates) as in benching/haunching/coping and similar other works like bands, plinth courses, lacing courses, bed plates, water troughs and the like incl weathring, slightly rounded or chamfered angles and throating, incl necessary form work, complete all as specified and directed. (Note - Reinforcement if provided, shall be measured and paid separately under relevent items).
M&L Glass dividing strips 38x3 mm thick and inserted in position to confirm to design complete all as specified and directed.
S&F 150 mm aluminium alloy handles, cast type, anodised complete all as specified and directed.
S&F 300 mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 300 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including aminium of 6 bolts and nuts, four on bold plate and two on staple plate and fixed complete all as specified and directed.
S&F 200 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
SCH 'A' PART-II : E/M PORTION Taking down carefully aluminium/copper point wiring any type including batten/casing caping for light/ fan/bell/socket or power and including unscrewing from board, fitting and fixure such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Material and labour for point wiring for light point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade IS694-1990 controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through PVC conceal conduit medium grade of size 20 mm with all accessories on wall/floor/ceiling including necessary chipping /grooving etc with 16G MS pressed steel terminal box with 3mm thick laminated sheet cover for mounting of fittings like switch, socket and fan regulator complete and making good the disturbed surafce (including necessary painting to match the existing surface) complete all as specified and directed.
Ditto all as per item No 52 above but for one 3 Pin socket outlet 5/6 Amps, on the independent board.
Ditto all as per item No-52 above but for One 3 pin socket outlet 5/6 Amps, on the same board with other switches.
Ditto all as per item No-52 above but with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade for one 3 pin 15/16 Amps socket out let controlled by one switch on independent board complete all as specified and directed.
S & F switch piano, flush type, single pole one way 5/6 Amp complete all as specified and directed.
S & F switch piano 15/16 Amp flush type complete all as specified and directed.
S & F socket outlet 3 Pin, 6 Amp flush type complete all as specified and directed.
S & F socket outlet 15/16 Amp flush type complete all as specified and directed.
S & F step type electronic fan regulator flush type for ceiling fan on the phenolic laminated sheet complete all as specified and directed.
M & L for ceiling rose PVC/Polycarbonate, isolated body 63.5 x 23.5mm 3 terminals complete all as specified and directed.
Supply and fixing in replacement LED tube light fittings 1 x 20 watts, 230 volts, 4 feet long complete with all accessories internally pre-wired and including connecting up with twisted flexible cable of 0.75 sq mm 3 core copper conductor from ceiling rose to light fittings complete including taking down old UNSV light fitting complete all as specified and directed. Make:-Havells, Model : LHEXARP7SN1W020 or equivalent make of Crompton/Bajaj/Philips
Supply and fixing sheet metal enclosure DB TPN 240 volts 4 way double door type with suitable rated bus bar for fixing MCB, including taking down old UNSV DB complete all as specified and directed. Make-Indoasian /Havells/Legrand/C&S
Supply and fixing sheet metal enclosure DB SPN 240 volts 12 way double door type with suitable rated bus bar for fixing MCB, including taking down old UNSV DB complete all as specified and directed. Make-Indoasian /Havells/Legrand/C&S
Supply and fixing sheet metal enclosure DB SPN 240 volts 8 way double door type with suitable rated bus bar for fixing MCB, including taking down old UNSV DB complete all as specified and directed. Make-Indoasian /Havells/Legrand/C&S
Supply and fixing MCB TPN 240 volts 40 To 100 AMP, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian/Havells Standard/Legrand.
Supply and fixing MCB SPN 240 volts 40 to 63 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian/Havells Standard/Legrand.
Supply and fixing MCB SPN 240 volts 32 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian/Havells Standard/Legrand.
Supply and fixing MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian/Havells Standard/Legrand.
M&L for sub main wiring with two single core PVC insulated, PVC sheathed stranded copper conductor (FRLSH) cable of size 2 x 10 sq mm unsheathed drawn in and including PVC conduit concealed and 1 x 10 sq mm PVC insulated unsheathed copper conductor as continous earth continuity conductor drawn in including taking down old UNSV submain wiring complete all as directed and specified. Note – 2 Nos of single core cable along with earth wire and PVC conduit shall be measured as one length.
M&L for sub main wiring with two single core PVC insulated, PVC sheathed stranded copper conductor (FRLSH) cable of size 2 x 6 sq mm unsheathed drawn in PVC conduit concealed and 1 x 6 sq mm PVC insulated unsheathed copper conductor as continous earth continuity conductor drawn in including taking down old UNSV submain wiring complete all as directed and specified. Note – 2 Nos of single core cable along with earth wire and PVC conduit shall be measured as one length.
Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level, Pipe electrodes shall be cut tapered at the bottom and provided with 12 mm holes (staggered) at 75 mm Centre to centre upto 2 metre of length from bottom and connected with earthing lead of 4mm dia galvanised iron, all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8 mm dia TMT bar @150 c/c both ways, one lifting handle made out of 10 mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15cm thick, necessary excavation earth work complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wallor inside wall or batten or recess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron wire and making good the disturbed surface complete all as specified and directed.
S&F in replacement bracket for security light made out of 1.5 Mtr long, 32 mm bore GI tubing, medium grade bent to required angle/ shape with and including necessary clamps, nuts, bolts, & washers of suitable size and including taking down old existing bracket complete all as specified and directed .
Supply and fixing in replacement LED security light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed on bldg/street light pole of any height including necessary clamping connections/wire complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells)
Taking down existing ceiling fan of any sweep with disconnecting the electric connection and carrying to the store complete all as specified and directed. (Note: Old unserviceble fan will be deposited as directed)
Hanging only serviceable ceiling fan of 1400 mm sweep retrieved from Item No 76 complete all as specified and directed.
Supply and fix down rod 1/2" dia, 3 feet long of hanging of ceiling fan complete all as specified and directed.
Supplying and fixing 1100 volts, grade heavy duty cable PVC insulated 10 sqmm soild aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supplying and fixing 1100 volts, grade heavy duty cable PVC insulated 6 sqmm soild aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supply and fixing PVC rigid non-metallic conduit of size 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1400mm sweep, with copper bound Squirrel cage induction motor complete all as specified and directed. Make:Havells/Crompton/Bajaj.
S&F in replacement 200 W LED flood light/highmast light fitting energy efficient light distribution with IP66 protection including all necessary clamps, nuts , bolts or fixing arrangement complete all as specified and directed.(Make:Havells, Cat Part No - JETAIRISALPHAFL200WLED857PBOLTG equivalent model of Crompton / Bajaj / Philips.)
SMART ENERGY SOLUTIONS (BID ID -3358942)
RANA ENTERPRISES (BID ID -3346937)
S.M.CONSTRUCTIONS (BID ID -3358913)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .