Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
17 Aug 2023, 11:00 amClosed
Superintending Engineer
S.E EUDC Office sec-18 Noida
33 and 11 KV Line Shifting Work in Full Deposit Scheme
2023_PVVNL_827156_2
E-Tender No. 62/2023-24, EUDC-II, Noida.
Open Tender
Electrical Works
Item Rate
30 days
S.E EUDC Office sec-18 Noida
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E., EUDC-II Noida
₹14,000
23 Aug 2023
8 Aug 2023
17 Aug 2023
8 Aug 2023
17 Aug 2023
8 Aug 2023
Amount
11 KV Line Shifting in front of M/s Bansal Wire, Dadri.
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 1 to 7
PCC Pole 8.5mtr Long
11KV XLPE Cable 3x185sqmm
11KV O/D Termination Kit
ACSR Rabbit Conductor
Line Accessories ( 11KV Top Channel - 4 Nos., 11 KV Dropper Channel - 12 Nos., 11 KV Disc with Fitting - 12 Nos., 11KV Pin Insulator with Pin - 12 Nos., Stay Set - 16 Nos., etc.)or any other material releated to work etc.)
Errection of Following material as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) 8.5mtr PCC Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) 8.5mtr PCC Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) 11M Long STP, SP-55 Round Pole
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps.
Laying, spreading, lifting and final sagging of 3 phases ACSR Rabbit conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel as per site requirement.
Making Jumpers on Sectional Pole, by providing & fixing of P.G.Clamps of proper sizes, suitable for ACSR Dog Conductor as per site requirement.
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Fixing and Comissioning of 11 KV O/D Termination Kit suitable for 3x185sqmm XLPE Cable with the help of Jointer with digging and refill of kacha/pakka hot mix road and complete connections in all respect. (Termination Kit shall be provided by the deptt. and work, material related to work in the scope of contractor).
Fixing of 11KV Pin Insulator with Pin as per RESPO.
Fixing of Top Channel as per RESPO.
Supply and Fixing of Danger Board with clamp and nut & bolt as per RESPO.
Fixing of Dropper Channel as per RESPO.
Fixing of 11KV Disc Insulator with fitting as per RESPO.
Supply and fixing of G.I. Pipe 6"dia at the tale of cable on riser of double pole.
Supply and Fixing of Stone Pad as per RESPO.
Supply and Fixing of Holding Clamps for PCC Poles.
Supply and Fixing of MS Not Bolts off size as per site requirement.
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. after digging trench for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and Providing & Laying of Ist Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, Providing 150 thickness mm River sand for cushion beneath and 150mm above the cable and Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Laying of 11KV, 1x185Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & G.I.Pipe and making connection with 11KV over head line at both ends.
Dismentaling of old & used pcc pole - 2 Nos. and Condcutor old & used in pieces Kg. - 20 and removal of other line accessories with safe carriage of above material site to any store of PVVNL including loading and unloading from both sites.
33 KV Line Shifting in front of M/s Bansal Wire, Dadri.
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 1 to 6
STP 11Mtr. Long
STP 13Mtr. Long
33KV XLPE Cable 3x300sqmm
33KV O/D Termination Kit
33KV Straight Through Kit
ACSR Dog Conductor
Line Accessories ( 33KV Top Channel - 4 Nos., 33 KV Dropper Channel - 12 Nos., 33 KV Disc with Fitting - 18 Nos., 33KV Pin Insulator with Pin - 12 Nos., Stay Set - 16 Nos., 33KV Bracing Angle -8 Nos. etc.)or any other material releated to work etc.)
Errection of Following material as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) 13 Mtr. Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) 11 Mtr. Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) 11M Long STP, SP-55 Round Pole b- 13Mtr Long STP
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps.
Laying, spreading, lifting and final sagging of 3 phases ACSR Rabbit conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel as per site requirement.
Making Jumpers on Sectional Pole, by providing & fixing of P.G.Clamps of proper sizes, suitable for ACSR Dog Conductor as per site requirement.
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Fixing and Comissioning of 33 KV O/D Termination Kit suitable for 3x300sqmm XLPE Cable with the help of Jointer with digging and refill of kacha/pakka hot mix road and complete connections in all respect. (Termination Kit shall be provided by the deptt. and work, material related to work in the scope of contractor).
Fixing and Comissioning of 33 KV Straight Through suitable for 3x300sqmm XLPE Cable with the help of Jointer with digging and refill of kacha/pakka hot mix road and complete connections in all respect. (Termination Kit shall be provided by the deptt. and work, material related to work in the scope of contractor).
Fixing of 33KV Pin Insulator with Pin as per RESPO.
Fixing of Top Channel as per RESPO.
Supply and Fixing of Danger Board with clamp and nut & bolt as per RESPO.
Fixing of Dropper Channel as per RESPO.
Fixing of 33KV Disc Insulator with fitting as per RESPO.
Supply and fixing of G.I. Pipe 6"dia at the tale of cable on riser of double pole.
Supply and Fixing of Stone Pad as per RESPO.
Supply and Fixing of Holding Clamps for PCC Poles.
Supply and Fixing of MS Not Bolts off size as per site requirement.
Fixing of Bracing Angle 65x65x6x4200mm as per site requirement.
Laying and commissiong of 33KV 3x300sqmm XLPE Cable Double Ckt. after digging trench for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and Providing & Laying of Ist Class Bricks, along the length on both side of 33KV XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, Providing 150 thickness mm River sand for cushion beneath and 150mm above the cable and Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Dismentaling of old & used ST pole - 3 Nos. and Condcutor old & used in pieces Kg. - 90 and removal of other line accessories with safe carriage of above material site to any store of PVVNL including loading and unloading from both sites.
Laying of 33KV, 3X300Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & G.I.Pipe and making connection with 11KV over head line at both ends.
R. P. T. Electrical
Vivek Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .