Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 CrAccepted-AOC | ₹33.9 Cr Quoted ₹35.0 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹35.3 CrRejected-Finance | ₹35.3 Cr | L2 | Rejected-Finance Rejected |
| 3 | Rejected-Technical GUWAHATI | KAMRUP | ASSAM | 781030 | - | - | Rejected-Technical Rejected |
Tender Value
₹33.9 Cr
EMD Value
₹43.9 L
Closing Date
2 Sept 2021, 11:00 amClosed
Executive Engineer-III,PDA Manipur.
PDA Complex, North AOC, Imphal- 795001.
Development of Integrated Command and Control Centre (ICCC) Building under Imphal Smart City Mission.
2021_PDA_1495_1
No. EE-III-PDA/NIT/2021-22/1
Open Tender
Civil Works
730 days
As Per Tender Document
Please refer Tender documents.
7 documents required · 7 mandatory
₹15,000
Planning and Development Authority, Manipur.
₹43.9 L
27 Sept 2021
13 Aug 2021
2 Sept 2021
16 Aug 2021
2 Sept 2021
16 Aug 2021
Amount
(A) BUILDING:-
EARTHWORK:-
Earthwork in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms lift upto 1.5 metres I/c getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres (a)Loose/Soft soil.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Extra for every additional lift of 1.5 m or part thereof in Loose/Soft or Hard/Dense soil
Rolling and consoldating formation surfaces including filling in depressions which occur during the process with power roller exceeding 8 tonnes but not exceeding 12 tonnes.
Dry flat brick flooring with 3rd class (local mixed class) bricks & filling joints with fine sand .
Providing laying and compacting granular base/sub-base according to lines, grades and cross sections by using naturally occured sand gravel/conforming to IRC Grading-II of M.O.S.T. specifications free from organic or other deleterious constituents compact by rolling with power roller of 8 to 10 tonnes capacity in layers not exceeding 150 mm ( spread thickness ) including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer in charge ( with carriage of materials)
Honeycomb brick work (75mm) thick with first class brick in cement mortar 1:4 (1 cement: 4 coarse sand)
Providing & fixing GI pipes complete with GI fittings i/c trenching and refilling etc. (external work) 65 mm dia.
Providing & laying four course water proofing treatment with bitument felt over roofs consisting of first & third courses of blown or/and residual bitument applied hot 13.61 kg per 9.29 sqm of area for each course second course of roofing felt type 3 grade 1 (Hessian base self finished bitumen felt) & fourth & final course of stone grit 6 mm & down size or pea size gravel spread at 0.06 cum per cum per 9.29 sqm i/c preparation of the surface etc complete.
CONCRETE WORKS:
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size)
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
Providing and laying 22 mm thick precast cement concrete chequered tiles on fpptpath over 20mm thick bed of cement mortar 1:3 complete as per drawing and technical specifications.
REINFORCED CEMENT CONCRETE WORKS:
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 380kg. of cement per cum of concrete. All work upto Plinth Level.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 380kg. of cement per cum of concrete. All work above Plinth Level upto floor V Level.
Boring, providing and installation bored cast-in-situ reinforced cement pile of specified dia meter and length below the pile cap M-25 in cement concrete, to carry a safe working load not less than specified, excluding the cost of steel rainforcement but including the cost of boring with casing and / or bentonite solution and the length of pile to be embeded in the pile cap etc. all completed (Length of the pile for payment shall be measured upto bottom of pile cap) 600mm diameter piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne Safe capacity(Refer DSR-2018 (20.6.2)). Initial test (Test Load 2.5 times the Safe capacity) Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete Thermo-Machanically Treated bars
FORM WORK:
Centering and shuttering including strutting, propping etc. and removal of form for :
(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Suspended floors, roofs, landings, balconies and access platform
( C )Vertical and horizontal fins individually or forming box louversVertical and horizontal fins individually or forming box louvers band, facias and eaves boards
( d ) Columns, Pillars, Piers, Abutments, Posts and Struts
(e) Lintels, beams, plinth beams, girders, bressumers and cantilevers
( f ) Edges of slabs and breaks in floors and walls . Under 20 cm wide
(g) Chimneys and shafts
(h) Stairs, (excluding landings) except spiral-staircases
BRICK WORK:
2nd class (local first class) brick work in foundation and plinth and superstructure in cement mortar 1:4 (1 cement : 4 coarse sand) up to first floor level
Half brick masonry 2nd class (local first class) in c/mortar 1:3 ( 1 c :3 c/sand) in superstructure.
STEEL & IRON WORK:-
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
FLOORING WORK:
Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by manufactureer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand ) including grouting the joints with white cement and matcing pigments etc., complete.(ii) Size of Tile 600 x 600mm.(Double charge) (a) Branded
Providing and laying rectified (No-skid) Glazed ceramic floor tiles 300x300mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Granite stone slab flooring over 20mm (average) thick base cement mortar 1:6 ( 1 cement: 6 Deopani sand) laid and jointed with grey cement slurry including rubbing and polishing complete with (b) Granite 12.5 mm thick slab(i) Black onix(30cmx60cm)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting and dado, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. size of tile 30x30cm (Double charged) Branded
FINISHING WORK:-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized wirh zinc coating of 120gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25mm wide x1.6mm thick with flanges of 27mm flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 45mm centre, with 25mm long dry wall screwa @ 230mm interval, including fixing of gypsum board to 12.5mm thick tapered edge gypsum plain board conforming to IS:2095-part-1
12mm cement plaster 1:3 (1 cement : 3 fine sand)
15mm cement plaster 1:4 (1 cement : 4 fine sand)
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering (two or more coats) with oil bound washable distemper of approved quality on new work i/c priming coat to give an even shade.
Applying one coat of cement primer of approved quality on wall surface.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.409 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge
SS Patch Fitting Fix Glass: Providing and fixing 12mm thk. Toughened float glass glazing cut and fixed in openings of desired shape as per drawing with 3/4" beveling all around, fixed with the help of SS patch fittings, with top and bottom 'C' channels, fixed firmly to the slab/ MS Structure ,as directed by Engineer in Charge. Area of openings to be measured). Assume frameless glass. Rate of above item to include P/F of : 20x20mm "C" channel SS patch Fittings.
WOOD WORKS:
Providing wood works in frames of doors, window, clerestory windows & other frames, wrought framed & fixed in position Local best quality Teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts nuts & wooden plugs & embedding to ceement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 20mm nominal gauge).
Providing and fixing Aluminium sliding bolts bright finished or black enamelled with nuts & screws etc. complete. 300mm x 16mm
Providing and fixing Aluminium Tower bolts (barrel type) with screws etc. complete. 250mm x 10mm
Providing and fixing Aluminium handles with necessary screws etc. complete. 125mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing RFID Card locking system with necessary accessories and screws etc. complete
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) (Refer DSR-2018 (9.147B.1))
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.)
STEEL & IRON WORK:
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint. In gratings, framed guard bars, ladders, railings, brackets and similar works.
ACOUSTICAL TREATMENT WALL SYSTEM: Providing and fixing of fire retardant fabric panels (colour as approved by the consultant) glued to 25mm thick melamine foam over a layer of 9 mm thick commercial ply with 15% perforations fixed over a framework of 48mm GI Stud of 0.55mm thk @ 600mm c/c . The ply to have perforations as per design drawings. The foam to be backed with 50mm 1000GSM thermally bonded polyester wadding. The rate includes for all Geometry of wall, openings etc. and for complete item including all the required approved material, labour and fixing as per drawings. The work shall be executed by the suppliers Authorized applicators. Approved Make: Malimiano of ABSOUND OVERSEAS, ANUTONE or equivalent.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. (Refer DSR-2018 (8.10)) Granite Stone of approved shade
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. (a) Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): with float glass panes of 5.5mm thickness
Supply and Installation of Compact Interior grade 12mm thick panels of standard size with both side decor as per specification. The panels are durmor high pressure laminates (HPL) in accordance with EN438 /4 type CGS for demanding application as Cubicles, Wall Partition, wall cladding etc. Toilet Partition Cubicle System with approved color laminate and system, the system shall be designed for the sizes mentioned in the drawing, all fixtures like SS thumb turn, SS occupancy indicators Door nob, SS hinges and door opening shall be as per detail drawing, ( Note: Patch fittings, Pedestals , laminate colour shall be as approved by Clients /Architect) Size:- 2000mm in height, door opening 600mm, side partition will be 1800mm
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound confirming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand ) admixed with water proofing compound confirming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement of 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound confirming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound confirming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar 1:4 (1 cement : 4 coarse sand ) admixed with water proofing compound confirming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-charge: With average thickness of 120mm and minimum thickness at khurra as 65mm.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm
UNDERGROUND WATER RESERVOIR :-
Earthwork in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms lift upto 1.5 metres I/c getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres (a)Loose/Soft soil.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size)
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 380kg. of cement per cum of concrete. All work upto Plinth Level.
Steel reinforcement for R.C.C. work including straightening, …......... (a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :
(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Suspended floors, roofs, landings, balconies and access platform
(c ) Lintels, beams, plinth beams, girders, bressumers and cantilevers
15mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement.
C.I cover with frame 450x600mm
ROAD WORKS:-
Preparing subgrade by excavating earth upto 22.5cm deep dressing to camber and consolidating with road roller including disposal of surplus earth within 50m.
Extra for completion of earth in embankmets under suitable moisture content condition as directed by the Engineer-in-charge to give at least 95 p.c. of the maximum dry density (proctor density).
Providing laying and compacting granular base / sub-base according to lines, grades & cross-sections by using naturally occurring sand gravel / conforming to IRC grade 2 of M.O.S.T. specification free from organic or other deleterious constituents compact by rolling with power roller of 8 to 10 tonnes capacity in layers not exceeding 150mm (spread thickness) including rolling of the road surface to prper level & grade 30cm width edging on both sides etc. complete as directed by the engineer-in-charge. (without carriage charge of all materials)
Providing and laying 60mm thick factory made cement concrete interlocking paver block (Rubber moulded) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of the Engineer-in-charge.
Precast cement concrete M-15 karb including fixing at site
2No. Main Gate:-
Earthwork in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms lift upto 1.5 metres I/c getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres (a)Loose/Soft soil.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 380kg. of cement per cum of concrete. All work above Plinth Level upto floor V Level.
Steel reinforcement for R.C.C. work including straightening, …......... (a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :
(a) Foundations, footings, bases of columns, etc. for mass concrete
( b ) Columns, Pillars, Piers, Abutments, Posts and Struts
15mm cement plaster 1:4 (1 cement : 4 fine sand)
Steel work welded in built up sections framed work i/c cutting,hoisting, fixing in position and applying coat of red lead paints. (a) in gratings, framed guard bars, ladders, railings, brackets and similar works.
Painting two more coats (excluding priming coat) with chocolate, red, grey of buff paint approved quality on new steel or wood work.
Providing and fixing cast iron spear head over the top of iron grills
Finishing walls with weather shield paint of approved quality on new work(three or more coats) to give an even shade.
Boundary:-
Earthwork in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms lift upto 1.5 metres I/c getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres (a)Loose/Soft soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 380kg. of cement per cum of concrete. All work upto Plinth Level.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 380kg. of cement per cum of concrete. All work above Plinth Level upto floor V Level.
Steel reinforcement for R.C.C. work including straightening, …......... (a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :
(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Vertical and horizontal fins individually or forming box louversVertical and horizontal fins individually or forming box louvers band, facias and eaves boards
Steel work welded in built up sections framed work i/c cutting,hoisting, fixing in position and applying coat of red lead paints. (a) in gratings, framed guard bars, ladders, railings, brackets and similar works.
Applying ready mixed priming coat (Red lead primer of approved quality) on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shade.
P/F cast iron spear head over the top of iron grills
Providingand applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with weather shield paint of approved quality on new works (three or more coats) to give an even shade
DEMOLITION AND DISMANTLING WORKS:-
Dismantling sheet roofing including ridges, hips, valleys, gutters etc. stacking the serviceable materials and disposal of unserviceable materials within 50 m lead. (a) G.I sheet roofing
Dismantling wood work wrought framed and fixing in frames, other frames and trusses of span up to 10m and height between ridge and floor level upto 5m including stacking the materials within 50m lead. (a) Section area average 40 sq.cm or over.
Dismantling textile covering in ceiling/walling including frames and cover fillets stacking of serviceable materials and disposal of unserviceable materials within 50m lead.
Demolition of brick work above G.L upto floor two level including stacking of serviceable materials and disposal of unserviceable materials within 50m lead.
Dismantling doors, windows and clerestory windows ventilators etc. (wood or steel) shutters including choukhats archraves, holdfasts and other attachment etc complete and stacking them within 50m lead. (a) Not exceeding 3 sqm in area.
Demolition of brick work below G.L upto 1m depth including stacking of serviceable materials within 50m lead and disposal of unserviceable materials within 50m lead. (a) In cement mortar
Demolition above G.L. upto floor two level including disposal of unserviceable materials with 50m lead. (a0 Unreinforced cement con crete upto 15cm thickness.
C.G.I SHEET FENCING :-
Earthwork in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms lift upto 1.5 metres I/c getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres (a)Loose/Soft soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying of Bamboo Saneibi species above 75 mm to 125 mm dia
Supplying of Bamboo Moubi 40 mm to 50 mm dia
Hiring of labours for fixing C.G.I to Bamboo (i) Belder (Unskilled labour)
HORTICULTURE AND LAND SCAPING WORKS:-
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete.
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : (Refer DSR-2018 (2.4)). Screened through sieve of I.S. designation 16 mm
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : (Refer DSR-2018 (2.4)). Screened through sieve of I.S. designation 4.75 mm
Rough dressing the trenched ground including breaking clods.
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing of the ground.
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : (Refer DSR-2018 (2.14))Holes 90 cm dia, and 90 cm deep
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : (Refer DSR-2018 (2.14)). Holes 60 cm dia, and 60 cm deep
Providing and wartering of irrigation water through water tanker of Horticulture features i.e. lawn, tree, shrubs, hedge/edge, ground cover etc. at the site of work. Water tanker having 5000 lit. capacity with one labour for watering i/c cost of water, filling of tanker, wartering at site with all leads and lifts as per direction of officer-in-charge.
Providing and applying anti termite treatment of infected trees i/c all branches/leaves by spraying chemical emulsion 0.5% (Chlorpyriphos 20% EC) concentration through power spray machine (@ 100 ml Chlorpyriphos per tree i/c cost of chemical) and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Chorisia speciosa of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Erythrina indica of height 150-165 cm. in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-incharge.
Providing and stacking of Jacaranda mimosifolia of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Washingtonia filifera palm well developed 90 to 105 cm ht. having 5 to 6 straight fresh and healthy leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy as per direction of the officer-in-charge.
Providing and stacking of Allamanda cathartica of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and Displaying Acalypha green well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot / Plastic Pot bushy as per direction of the officer-in-charge.
Providing and stacking of Ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in p.bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Hibiscus variegated of height 45-60 cm. with 3-4 branches and healthy variegated foliage in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge.
Providing and stacking of Plumbego capensis well developed with fresh and healthy 30 to 45 cm ht., with bloom in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge.
Providing and stacking of Tabernaemontana coronaria (chandni variegated) of height 45-60 cm. with 3-4 branches earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Tecoma gaudichaudi of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and Displaying Tapioca varigated (Manihot esculenta) well developed fresh & healthy 30 to 45 cm ht. in bright colour foliage in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Providing and stacking of Syngonium variegated,of height 20-30 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge.
Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge.
(B) INTERNAL PLUMBING WORKS:-
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fitting & C.I. brackets, 40 mm flush bend,overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, including paintingof fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550X400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perIS: 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610X510 mm bowl depth 200 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Flixible pipe 32 mm dia
Providing and fixing toilet paper holder : C.P brass
Providing and fixing PTMT pillar cock of approved quality and colour .15 mm nominal bore, 107 mm long, weighing not less than 110 gmsEach374
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mmEach374.86238621.69high and 112 mm distance from wall of standard shape with bracket ofthe same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Rectangular shape 1500x450 mm
Soil,Waste and Vent Pipes :-
Providing and fixing uPVC Soil ,Waste,Rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer in charge
75 mm dia
110 mm dia
160 mm dia
Providing and fixing PVC traps with 100 mm inlet and 75 mm outlet of self cleaning design with screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
Providing and fixing 125 mm dia, 1 mm thick CP grating with frame for floor traps or drains of required pattern including cutting and making good the floors complete. 125 mm dia
Providing & fixing uPVC clean out plug with suitable insert keys for opening in PVC cap, male threaded joint with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 110 mm
Providing and fixing reducing floor drain of 110x63 mm OD as floor drain in cement concrete 1 : 2 : 4 float with floor complete in all respects.
Providing and fixing in position 125x125 mm square stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.0 mm thick top grating (Jali) with ring to be fixed inside uPVC ‘P’ traps with cement concrete.(for kitchen and pantry)
Providing and fixing 100 mm dia horizontal /100 x 100 mm vertical grating as required, 1 mm thick CP grating with frame for Balcony drains of required pattern including cutting and making good the floors complete.
Making khurras with average minimum thickness of 5 cm cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1m x 400m, finished with 12 mm cement plaster 1 : 3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete.
Khurras with CI grating 450 x 450 mm
Internal Water Supply :-
Providing and fixing chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direcrion og Engineer in charge.Concealed work, including cutting chases and making good the same
15mm nominal outer dia pipes
20mm nominal outer dia pipes
25mm nominal outer dia pipes
External work:-
Providing and fixing chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direcrion og Engineer in charge.
32mm nominal outer dia pipes
WATER SUPPLY RISER (IN SHAFT VERTICAL & BASEMENT CEILING LEVEL)
32mm nominal outer dia pipes
Providing and fixing ball valve (brass) complete of approved quality.
20mm nominal outer dia pipes
25mm nominal outer dia pipes
Providing and fixing Double layered insulated Water Tank (SINTEX), Use for Hygiene application water storage. Capacity described below; Material shall be provide with necessary mounting arrangement, valve, bend, Air vent provision, Level indicator & coupling etc. (with float type sensors) additional level indicator wiring/ panel and sensors in water tanks including necessary cables, conduits, upto junction box, pipe, butter fly/ball valves etc., complete. (OUT DOOR TYPE OPERATION)
Providing, installation, fixing, Testing and Commissioning of Hydro pneumatic pumping set with Double pump with equal Head loss. Pressure Vessel, Stand, Fixing Arrangement Complete with VFD, VFD panel with Cooling system including necessary accessories to operate independent operation. Capacity described below;Material shall be provide with necessary mounting arrangement, valve, bend, Air vent provision & coupling etc. (with all type sensors) additional wiring/ panel and sensors. Including necessary cables, conduits, upto junction box, pipe, butter fly/ball valves etc., complete. (OUT DOOR TYPE OPERATION ) Open type shed shall be provide by the Client. 4500 USGPM @ 26 mtr WG
Providing and fixing pressure regulating valve (PRV) for water supply line. PRV is tested to a pressure not less than 15.0 kg/cm2 and suitable to reduce the pressure as desired, including flanges/unions, nuts, bolts and washers complete as required for application.
32mm dia
Providing and fixing pressure gauges with isolation cocks and chrome plated copper pipes as PRV station to read pressure from 0-15 kg/cm2 complete. (For PRV pressure setting)
GARDEN IRRIGATION SYSTEM:-
Providing, fixing, jointing and testing of uPVC pipes conforming to IS 4985 class v (10 kg/cm2) including injection moulded fittings with bosses like bends, tees, adoptors etc. suitable for rubber ring jointing complete.
EXTERNAL SEWERAGE AND DRAINAGE WORKS :-
Supply, laying and jointing Spigot & Socket type R.C.C. NP-2 Pipe suitable for rubber ring joints, including lowering in trenches, laid to correct levels up to required depth including excavation in all kind of soil (hard / soft), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required. testing of joints and connection with the respective manhole complete in all respects as per the direction of engg-in-charge.jointing procedure - A rubber ring shall be placed on the spigot which shall be forced into the socket of pipe previously laid. This compresses the rubber ring as it rolls into the annular space formed between the two surfaces of the spigot and socket, stiff mixture of cement and mortar 1:2 ( 1 cement : 2 fine sand) shall then be filled into the remaining annular space and rammed with a caulking tool. After days work any extraneous material shall then be removed from inside of the pipe and the newly made joint shall be cured.
150 mm. dia. Spigot & Socket type RCC Pipes
Providing and laying cement concrete 1:4:8 (1cement : 4 coarse sand : 8 graded stone agg. 40 mm nominal size) in bedding & haunches of RCC pipes.
150 mm diameter RCC Pipe
Providing & fixing square-mouth uPVC Gully trap complete with grating, brick masonry chamber with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 coarse sand) inside plaster above trap 12mm thick m cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside plaster 12mm thick in cement mortar 1 :3 ( 1 cement : 3 coarse sand) 10cm thick foundation concrete 1 : 5 : 10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) space between chamber, and trap filled with cement concrete 1:2:4 (1 cement : 2 coarses and : 4 graded stone aggregate 20 mm nominal size) and water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg asper standard design. 300 x 300 mm gully trap chamber with 150 x 150 mm 'P' trap
Constructing brick masonry catch pit with F.P.S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete with PVC encased 12 mm dia steel bar foot rests fixing with 20x20x10 cm cement concrete blocks 1:2:4, including fixing of CI / PCCC / SFRC grating / cover and frame in 150 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 gradded stone aggregate of 20 mm nominal size) including centering, shuttering, excavation, refilling and disposal of surplus earth as directed complete in all respects. (The cost of grating/cover and frame shall be included) Inside size 650 x 650 mm & 750 mm deep
Constructing brick masonry manhole / Inspection Chamber with F.P.S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete with PVC encased 12 mm dia steel bar foot rests fixing with 20x20x10 cm cement concrete blocks 1:2:4, including fixing of CI / SFRC / PCCC MH cover and frame in 150 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 gradded stone aggregate of 20 mm nominal size) including centering, shuttering, excavation, refilling and disposal of surplus earth as directed complete in all respects. (The cost of MH cover and frame shall be included) Inside size 900 x 800 mm & upto 900 mm deep
Extra for depth for manhole with F.P.S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) as per above item (8). size 900 X 800 mm
Sub Head - XXI (Water Supply, Dewatering Pump):-
S.I.T.C of 3 HP, Mono-block pump set capable of delivering at a head 15-27 meter , Suc Del. Size 50mmX40mm , 3000RPM & Discharge Range 450-150 (LPM) electric motor suitable for 220 volt, Single phase, 50 HZ Ac supply, with chain pulley block and tripod stand, i/c connection etc. complete as reqd. (1W+1S) in One Set complete with Accessories.
S.I.T.C of 3 HP, submersible pump set capable of delivering 150 LPM at a head 100-50 meter directly coupled with submersible electric motor suitable for 220 volt, Single phase, 50 HZ Ac supply,with chain pulley block and tripod stand, i/c connection etc. complete as reqd. (1W+1S) in One Set complete with Accessories.
Providing & fixing of 08 mm Dia PVC insulated steel wire rope twisted for holding the pump set to avoid slippage with necessary clamp etc as reqd.
S & F 50 mm dia G.M gate Valve IS 778, class-2 body T.P 2.4 MPA Hyd.
S & F 50 mm dia G.M Horizontal Lift Check Valve IS 778, class-2 body T.P 2.4 MPA Hyd.
Providing and fixing submersible pump holding clamp set made out of 8 mm. thick M.S. Strip alongwith bore well cover suitable for 200 mm dia bore-well tested for holding of 05 HP multi stage
( C ) HVAC :-
Sub Head XVI - (VRF Air Conditioners)
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.
16 HP Out Door Unit
22 HP Out Door Unit
28 HP Out Door Unit
36 HP Out Door Unit
40 HP Out Door Unit
Indoor Units : -
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree CWB temperature.
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
Refrigerant Piping
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19mm thick insulation
31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Drain Piping
Supplying, laying/ fixing, testing and commissioning of Rigid uPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
32 mm dia
50 mm dia
Control & Transmission Wiring:-
Providing and fixing of Control wiring/power cabling with following sizes of copper conductor cable between indoor unit/outdoor unit/controllers inside/outside building in PVC Conduit ,on surface/existing channel, cable tray i/c making connection etc as reqd.
3c x 2.5 sqmm with required PVC conduit.
2core x 1.5 sqmm shielded cable or as per OEM Standard for operating all the indoor and outdoor units. The cost shall include with PVC conduit.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying of following sizes XLPE insulated armoured aluminium/Copper conductor, wrapped HDPE tape inner sheathed, Galvanised flat steel strip armoured and overall PVC sheathed cable suitable for 1.1 KV grade confirming to IS :7098/Pt.1 with up to date amdt. as reqd.
4C x 50sq mm.
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV grade of following size on wall surface as required
Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
4 X 50 sq. mm (35 mm)
(D) FIRE FIGHTING :-
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast iron body& bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 lpm at 70 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered.
2280 lpm at 70 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump).
Horizontal type, multistage, centrifugal pump of cast iron bodyand bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 70 m Head
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
Incoming
Outgoing
Main Fire Pump
Jockey Pump
Diesel Engine Control
Control for diesel engine comprising Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication
All standard relays and accessories for automatic operation of diesel engine
System Controller
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
150 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal cap and chain as required
Supplying and fixing single headed external Yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal coupling and cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal cap and chain as required
Supplying, fixing, testing and commissioning of butterfly valveof PN 1.6 rating with bronze/gunmetal seat dulyISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
150 mm dia
100 mm dia
80 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
150 mm dia
100 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
150 mm dia
100 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
150 mm dia
100 mm dia
80 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : GUN Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : GUN Metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way-150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Horizontal side wall sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working ressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as reqd.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
(F) Electrical-Internal Point Wiring :-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. : 4 X 4 sq. mm + 2 X 4 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. : 4 X 10 sq. mm + 2 X 6 sq. mm earth wire.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. : 2 Pair
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. : 1 run of cable.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. : 20 mm.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. : 25 mm.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 1 nos. 3 pin 5/6 A modular socket outlet and 1 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required TV antenna socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. : RJ 45
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as reqd. (But without MCB/RCCB/Isolator). : 8 way, Double door.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar formounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required. : 8 way (4 + 24), Double door.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar formounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. : Single pole.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole 40/60 Amp
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral 40/63 Amp
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. : 63 A.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 kA,TPMCCB ( For UPS)
Electrical-LT Cables
Supplying of following sizes XLPE insulated armoured aluminium/Copper conductor, wrapped HDPE tape inner sheathed, Galvanised flat steel strip armoured and overall PVC sheathed cable suitable for 1.1 KV grade confirming to IS :7098/Pt.1 with up to date amdt. as reqd.
3.5C x 240sq mm.(LT Panel to VRF Outdoor and ACDB)
3.5C x 150sq mm.(LT Panel to MPDB)
3.5C x 95sq mm.(LT Panel to Fire Panel)
3.5C x 35sq mm.(LT Panel to plumbing panel)
4C x 25sq mm.(LT Panel to Lift Panel, MLDB)
1C x 16sq mm.Copper(LT Panel to UPS Incomer)
4C x 10 sq mm. Copper
4C x 6 sq mm.Copper
3C x 4 sq mm.Copper
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV grade of following size in the existing RCC / HUME / M ETAL pipe as required.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1KV grade of following size on wall surface as required
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as reqd.
3.5 x 300 sq mm (70 mm)
3.5 x 150 sq mm (50 mm)
3.5 x 95 sq mm (45 mm)
3.5C x 35 sq mm (32 mm)
4C x 25 sq mm (28 mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-200 mm & ID-175 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supply and fixing of following size of under floor GI 3 compartment raceway in screed floor. Raceway should be made up of Pre galvanized sheet with thickness of 1.6mm consist of body and cover. It should have average of 120GSM zinc coating. Raceway should be openable from top. Cover fitted on to the body with self forming screw and can be opened easily if required. Raceway should be supplied with required accessories like fixing brackets and coupling plates etc. as required
300 mm width X 40 mm depth X 1.6 mm thickness
Supply and fixing of under floor crossover Junction box with flyover for above mentioned raceway for direct access to cables at the intersection of raceways supplied completely with base and cover plate(lid). Junction box should be made of 120 GSM zinc coated 1.6 mm thick pre galvanized sheet consisting of body and cover. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site etc. as required
Junction box for 300 mm width X 40 mm depth X 1.6 mm thickness raceway.
Electrical (LV Panels )
Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 100mmx50mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears.
All relays to operate at 240Volts, Single phase, 50Hz., AC supply through UPS. UPS of suitable Rating is also in the scope of Supply
Multifinction Meter: Flush mounting, 96X96 mm size class 1 accuracy and LCD display. Panel meter should be suitable for true RMS reading. Meter should measure line and phase voltage, current of all 3 phasees and neutral, HZ, PF, KW, KWH, KVAR, KVARH, KVA, KVAH, Voltage and current including one set of CT. Meter should be EMI/ EMC complaint. Meter should be with RS 485 port for communication on Modbus protocol.
All ACBs shall have Ics=Icu=Icw=50 KA for 1 second.
All ACBs should have Icw =Ics=Icu=100%
All MCCBs shall have Ics=Icu.
TMD based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection.
R, Y & B phase indicating lamp (LED type) with 6A control SP MCB & ON, OFF, TRIP Indication (LED type).
Separate fault indication for O/L, S/C & E/F to be provided on Panel Door.
Extended rotary operating mechanism with door interlocking with defeat feature and padlock facility. MCCB should have spreader links & phase barriers.
INCOMER:-
1 Nos. 63 Amps. TPN MCCB (25 KA) Thermal Magnetic based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-200 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
100 Amps. TP&N copper bus bars (25 KA)
OUT GOINGS:-
8 Nos. 40A TPN, MCB
INCOMER:-
1 Nos. 200 Amps. TPN MCCB (36 KA) Thermal Magnetic based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection.
R, Y & B Phase indicating lamps (LED type) with 6A control SP MCBs.
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-400 Amp. Ammeter (digital type) with inbuilt ASS .
BUS BARS:-
300A Amps. TP&N copper bus bars (36 KA)
OUT GOINGS:-
10 Nos. 63A TPN, MCB
INCOMER:-
1 Nos. 630 Amps. TPN MCCB (36 KA) Thermal Magnetic based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection.
Indicating lamps with 6A protection MCBs to indicate OPEN, CLOSE, TRIP for ACB
R, Y & B Phase indicating lamps (LED type) with 6A control SP MCBs
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-630 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
800 Amps. TP&N copper bus bars (36 KA)
OUT GOINGS:-
6 Nos. 125A TPN, MCCB (25KA).
VRF OUTDOOR PANEL
INCOMER:-
1 Nos. 630 Amps. TPN MCCB (36 KA) Thermal Magnetic based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection
Indicating lamps with 6A protection MCBs to indicate OPEN, CLOSE, TRIP for ACB
R, Y & B Phase indicating lamps (LED type) with 6A control SP MCBs
MFM as mentioned above including one set of C.Ts
BUS BARS:-
800 Amps. TP&N aluminium copper busbars (36 KA)
OUT GOINGS:-
18 Nos. 100A TPN, MCCB (25KA).
PLUMBING PANEL
INCOMER:-
1 Nos. 63 Amps. TPN MCCB (25 KA) Thermal Magnetic based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection.
Indicating lamps with 6A protection MCBs to indicate OPEN, CLOSE, TRIP for ACB
R, Y & B Phase indicating lamps (LED type) with 6A control SP MCBs
MFM as mentioned above including one set of C.Ts
BUS BARS:-
100 Amps. TP&N copper bus bars (25 KA)
OUT GOINGS:-
3 Nos 40A TPN MCB with DOL starter(25KA)
4 Nos 32A TPN MCB with DOL starter(25KA)
LIFT PANEL
INCOMER:-
1 Nos. 100Amps. TPN MCCB (25 KA) Thermal Magnetic based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection.
Indicating lamps with 6A protection MCBs to indicate OPEN, CLOSE, TRIP.
R, Y & B Phase indicating lamps (LED type) with 6A control SP MCBs.
MFM as mentioned above including one set of C.Ts
BUS BARS:-
100Amps. TP&N copper busbars (25 KA)
OUT GOINGS:-
03 Nos. 63 Amps. TPN MCCB (25 KA)
UPS PANEL
INCOMER:-
1 Nos. 63 Amps. TPN MCCB (25 KA) Thermal Magnetic based MCCB with variable current settings and having O/L, S/C & inbuilt E/F protection
1 Set phase indication lights (R, Y, B)
1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
1 No. 0-200 Amp. Ammeter (digital type) with inbuilt ASS
BUS BARS:-
100 Amps. TP&N copper bus bars (25 KA)
OUT GOINGS:-
8 Nos. 40A TPN, MCB
Totla of Sub Head - III (LV Panels )
Electrical (Earthing & Lightning Conductor)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and laying earth connection from earth electrode with 6SWG dia G.I.Wire in 15 mm dia G.I.pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.(For street light pole).
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Sub Head - V (SAFETY EQUIPMENTS)
Providing & Fixing danger notice plates made of mild steel sheet at least 2mm thick & vitreous enamelled white on both sides & with inscriptions in single red colour on front side as required.
Medium Voltage size 200mm x 150mm
Supplying & erection of the following equipment at suitable place in the sub-station building as required.
Supply and fixing of CO2 type fire extinguisher having 4.5 Kg capacity ISI marked for IS 2878 filled with CO2 gas with 1 mtr long horn pipe fixing with dash fastener complete in all respect i/c numbering etc as required.
First Aid Box as approved by St. John Ambulance Brigade/Indian red Cross Society conforming to IS 2217-1963.
Shock treatment chart duly laminated etc. as required.(approximate front area 1.20 Sqmtr).
Electrical (Fan , Fittings)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing LED bulk head luminaries deep down polycarbonate boby resistant prismatic glass cover (bajaj/BIBWP 10 W LED)
Supplying, Installation, Testing and Commissioning of 34 watt to 40 watt 600 mm (Length) x 600 mm (Width) recessed mounted LED Luminaries made out of extruded aluminium housing duly powder coated suitable for operation on 230 Volt +- 10% single phase A.C. supply alongwith 36 to 40 watt. LED lamp, luman efficacy of fitting should not be < 100 Luman per watt., THD < 10% surge protection of 2 KV alongwith heavy duty BIS certified driver etc. including connection with 1.5 sq. mm. PVC insulated copper conductor cable etc. complete as required.
SITC of 18 to 20 watt. LED Lumainaries with extruded Aluminium housing with heavy duty BIS Certified driver, having Lumen efficacy 100 lumen per watt, THD < 20% CRI > 80% power factor > 0.9 driver efficenicy of 85% and Surge protection of 2 kv suitable for operation on 230 volt+ - 10%, 50 Hz A.C. Supply complete i/c connection, testing etc. as required.
Supplying, Installation, Testing and Commissioning of 18 watt LED down lighter surface/recessed type of Luman efficacy 100 Lumen/watt, THD<10% of cut out dimension not less than 145 mm suitable for operation on 230 Volt +- 10% single phase A.C. supply made out of pressure die-cast aluminium housing duly powder painted with white frosted glass, spring loaded mounting clips for easy mounting, in-built constant current driver etc. complete as required.
Supply, Installation, Testing and Commissioning of LED mirror light fitting including driver etc.as required. (Make:CG: LCL-07-CDL/ equivalent to bajaj/wipro/Philips).
Supplying, Installation of heavy duty of 900 RPM. having double ball bearing motor with high air delivery Exhaust fan with louver and shutter of size 300 mm sweep suitable for single phase AC supply in the existing opening including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as reqd.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Fabricating, Supplying & Fixing of Hexagonal Fan Box, in existing reinforement before casrting of slab and made out of 1.6 mm MS sheet and 12mm dia MS fan hock, duly painted, having MS cover of 1.6mm thick on top side and 3mm thick 200mm dia phinolica laminatad sheet cover with screw on other side (bottom) etc. complet as required
Sub Head - VII (Street Lighting)
Supplying, Installation, Testing and Commissioning of 35 watt post top lantern fitting made out of pressure die cast aluminium housing and IP 65 protection with round glass and hight power LED with lenses operation on 220 Volt 50 Hz AC supply having efficiecy of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV burning life not less than 50000 Hours, system efficacy 100 lumen perwatt colour temperature of 5500 to 6000 K, CRI >80 including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable i/c connection testing suitable to mount on 80 mm dia compound light poles with necessary arrangement etc. as required. (Make :- RUBYPT35WLED757PSYMPOPC / HAVELLS)
Supplying, Installation, Testing and Commissioning of Flood light fitting 70-80 Watt LED made out of aluminum die cast housing, IP 65 with high power LED as light source, system lumen efficiency of >110 lumen per watt, colour rendering (CRI) > 70, and correlated colour temperature (CCT) of 5500-6500( +- 300K), The luminaries should have 10KV surge protection, PF>0.95, the total harmonic distortion< 10% operatable in voltage range of 120-270 V, total burning hours 50000 with LM 70/79/80 Certificates. The driver used must be a constant current driver with efficiency of >85% and driving, current<725mA complete with duitable fasteners as required and as per direction of Engineer-in-Charge i/c dismantling of existing fittings.
Supply of steel tubular pole 4.5 mtr long 65 mm dia with base plate i/c painting etc as required, as per direction of engineer-in-charge.
Providing and laying (0.45 x 0.45 x0 .90) + (0.90 x 0.90 x 0.90) cum type muffing and errection of 4.5 mtr long pole embedded in 1:3:6 (1 cement : 3 coarse sand: 6 stone aggregate 40mm nominal gauge) i/c centering and shuttering the earth work etc as required.
Providing and fixing non metallic pole box of size 250mm X 200mm X 105mm (product code GSJB2520) with side openable hinged cover complete with two strip aluminium bus-bar of 100 amps capacity mounted on DMC bus support and 1 no. of SPMCB of 6 amps 'C' series capacity with din rail on the existing street light pole with the help of two nos. MS clamps of suitable size, including making hole to insert the cable and dismantling the worn out MS box etc. complete as required. (Hensel / K-8350/ size 260mm X 210mm X 116 mm)
Supplying and laying of 3x10 sq. mm. PVC insulated and PVC sheathed/ XLPE aluminium conductor armoured power cable suitable for rated voltage 1.1 KV grade (ISI marked) on surface/ RCC/HUME/ Metal/ HDPE etc. complete as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3x10 sq. mm. (22 mm.)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of one no. XLPE/PVC insulated sheathed Allmunium conductor armoured cable of 1.1 KV grade of size 3.5 X 35 sq. mm on surface/ Cable trya/HDPE Pipe etc. complete as required.
Electrical (Providing 1 Nos. 13 Passenger Lifts )
Supply installation testing & commissioning with machine room - gearless, 13 passanger (884 Kg) barrier free Lifts having contract speed of 1.5 MPS serving different floors in the lift shaft as per detailed specifications as under:
Location of Lifts : At lift lobby in connected to corridor.
Speed : 1.5 MPS
Controller : AC variable voltage & variable frequency
Automatic rescue device complete with dry maintenance free batteries as reqd.
Power : 415 V; AC 3 phase 50 HZ 4 wires system.
Type of doors :-
(a)Car : Power operated center opening horizontal sliding stainless steel scratch proof (moon rock finish)
(b)Landing doors : Stainless steel scratch proof (moon rock finish).
Stainless steel hand rail on three sides at a height of not more than 900 mm from car floor
Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator with intercom system
Brail signage/buttons both inside and outside of car.
Floors : B+G + 4
Travel : 18 Mtr. (Approx)
Stops & Opening : 6 Stops & 6 Opening
Electrical (SITC of 30 KVA UPS)
Supplying, installation, testing and commissioning of online IGBT based double conversion (IGBT based rectifier & IGBT based inverter), three phase input 415 volts + 10% & -15%, 50 Hz and three phase output 415 volts +/- 5% 50Hz, 20 KVA transformer on input and output side, efficiency >90% automatic UPS by pass arrangement on overload or UPS failure, capable to handle overload of 125% for 10 minutes, 150% for 1 network and modbus card with software to monitor and control the operation of UPS, cabinet, suitable ventilation arrangement suitable nos. of 12 volts, 42 AH 40 Nos. maintenance free batteries with battery management units, connecting strips complete set to support 30 minute backup for 20 KVA UPS set as per specification complete set as per specification.
Electrical (Addresable Fire Alarm System)
Two Loop Panel
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required
Supplying, installation, testing & commissioning of addressable manual call point complete as required
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. .
Supplying, installation, testing & commissioning of fault isolator complete with base as required
PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Cabling & Wiring
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required
speaker cable Two pair, 2-core, 1.5 sqmm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Electrical (CCTV)
Indoor type surveillance camera full HD (1080p Resolution,1920 x 1080 with 25/30fps) IP cameras with night vision-capability (0.01 Lux Infrared Night Vision) to cover entire complex and capacity to store recording for a period of minimum 7 days.CAT6 Structured Cabling Should be done for all IP Camera with power over Ethernet (POE) and complete with other peripherals like Racks, Patch Panel, Cisco Giga POE Switch, Cable Manager etc.Honeywell /Zexel/Pelco make.
Outdoor surveillance cameras- PTZ Full HD (1080p Resolution,1920 x 1080 with 25/30fps) P66 Weatherproof CCTV camera, HDR, Motion Detection, adjustable high / low Infrared beam, Infrared effective up to 200ft, Should include Smart IR Infrared illumination technology/Sense-Up Image Intensifier Technology, Automatic Day & Night Vision Modes, Digital Noise Reduction (DNR), Alarm Relay In / Out, Digital Alarm Output,and should be Power Over Ethernet. Cover entire Outdoor complex and capacity to store recording for a period of minimum 7 days, Keyboard controller for ptz camera. Approved Brand for CCTV Camera is Honeywell, Zexel, Pelco.CAT6 Structured Cabling Should be done for all IP Cameras with power over Ethernet (POE)
Supply,installation,testing and commissioning of color Digital Video Management system with cameras inputs for all the cameras Built in multiplexer, Digital Video recorder, Video motion Detection system, with external alarm inputs & outputs TCPIP network feature & hard disk to have a storage space for one month. The price shall also include connectors, junction boxes in various buildings, cabling from the buildings to the central console etc. 16-Channel Embedded DVR, 400/480fps, CIF recording, Real-time, Support (Simplified) and English OSD, SATA, 230VAC
Supply,installation,testing and commissioning of 55" inches Full HD (1080P) Wall mounting Monitors with Minimum 2 HDMI ports.Samsung/Sony/LG/Panasonic.
Supplying, Installation, testing and commissioning of Cat 6 Structured cabling with power over ethernet.
Supply, installation, testing & commissioning of PoE Layer II Managed Ethernet switch: 16 port RJ-45 10 base 100 T with 2 Fibre Ports.
Supply, installation, testing & commissioning of 19 inck rack mount console unit - 42 U with 4 cooling fans on top and bottom at control room.
Any other network equipment like Patch Chords, Patch Panels, Jack Panels, Splicing and LIU required for successful operation.
Supply, laying & testing of 2 x 1.5 sqmm FRLS PVC insulated Power Cable for powering all the SWITCHES.
Supply and fixing of following sizes of PVC conduit along with the accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
25 mm dia
Electrical (DG set with AMF Panel)
Providing installation, Testing and commissioning of 'Silent Type Diesel Generating set of Prime Powe Rating of 700 KVA 415 volts, 50 Hz, 3 Phase system at 0.8 lagging power factor & 0.85 Load factor and consisting of the following, capable of taking 10% over loading for one hour in any period of 12 hours of continuous operation at full load.
Diesel Engine: 4 stroke water cooled electric start Diesel engine of 154 BHP rating at 1500 RPM with turbo charged air cooled aspiration, A1 class mechanical governor, suitable for above output of Alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, The engine will be fitted complete with all the required accessories i/c Safety Controls to shut down the Engine in the event of any abnormality of temperature/ pressure/ speed/ voltage/ current etc. The Engine mounted instrument panel with indication for temperature/ pressure/ hour etc. as per OEM.
Engine mounted instrument panel fitted with and having digital display for following:
Start-stop switch with key
Water temperature indication
Lubrication oil pressure indication
Battery charging indication.
RPM indication.
Over speed indication.
Low lub. oil trip indication.
Engine Hours indication.
Alternator:
Synchronous alternator rated at 750 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 meter MSL. The alternator shall be having Screen Protected Drip Proof enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation.
Base Frame and Foundation:
Both the engine and alternator shall be mounted on the base frame made of MS Channel and vibration isolation arrangement (AVM pads) including providing of suitable cement concrete foundation as per recommendations of OEM/OEA.
Fuel Tank:
In built fuel tank Daily service fuel tank of suitable capacity as per OEM/OEA standard complete with all standard accessories and MS class C fuel piping between fuel tank and diesel engine
Extra fuel tank: Extra service fuel tank of 500 liters capacity fabricated out of 2 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS pipes 'C' class of suitable dia. (appx. length 10 mtr.) Complete with valves, level indications and accessories as required.
Exhaust System:
Dry exhaust manifold with residential exhaust silencer as per manufacturer specifications to meet stringent sound emission standards laid down by CPCB/MOEF (beyond standard length if required shall be paid extra).
Starting System:
12 V DC starting system comprising of starter motors, voltage regulator and arrangement for initial excitation complete (as per standard supply of the OEM).
Acoustic enclosure:
Acoustic and weather proof enclosure manufactured by OEM as per CPCB norms suitable for outdoor application with arrangement for fresh air, intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere as per specifications of OEM/OEA.
Control Cable:
Supplying & laying control cable between DG set to AMF panel as upto 40 Mtrs. Length is the scope of the work and beyond this will be paid extra.
Fabricating, Installing, Testing and commissioning of Automatic Mains Failure Control with manual by- pass panel shall be comprising of 2 Nos. ON Load change over switches of 250 Amp capacity each, fabricated out of 1.6mm thick CRCA steel sheet duly pre-treated and aesthetically finished , totally enclosed dust & vermin proof floor mounted suitable for 125 KVA silent type DG set complete with inter locking system. Entire Panel shall have a common copper earth bar of size 25 mm X 5mm at the rear with 2 Nos. earth stud, interconnection wiring with suitable size cooper conductor PVC insulated cables / solid connections between switchgear to switchgear and control wiring with 2.5 sqmm PVC insulated copper conductor s/c cable, cable alloys cable gland plates in two half i/c providing following switchgears.:
2 Nos., 250 Amp. 4 Pole MCCB of 35 KA (ICS= 100% ICU) breaking capacity with contactors of AC-3 duty.
Over Voltage Relay and Under Voltage Relay
1 Set of 3 Nos. of current transformers of 15 p 1.0 accuracy for protection and 15 VA class-I for metering.
Energy analyzer unit to indicate current ,voltage, frequency, power factor and KWH etc.
Indicating lamps for load on mains and load on set.
SPMCB/Fuse for instruments.
Main supply failure monitor.
Supply failure timer
Restoration timer
Control unit with three impulse automatic engine start/ stop and failure to start lockout.
Impulse counter with locking and reset facility
ON/OFF/ Control circuit switch with indicator.
Audio/Video annunciation for:
Engine over speed
Engine fails to start
Over load warning
Sub Head - XIII (Sub Station Equipment)
Supplying installation testing & commissioning of indoor type floor mounted metal clad, 11 KV VCB panel with 3 no. VCBs, totally enclosed & fully interlocked, horizontal draw out, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below ,single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase 50 HZ A.C supply with short circuit fault level of 350 MVA, Complete with self contained, fully interlocked ,rack in and rack out mechanism, air insulated but incapsulated copper bus bars of 630 Amps capacity, breaker fearutured with mechanical ON/OFF indicator with hand trip device ,spring release coil shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories i/c connections suitable for 3 X 185 sq mm .XLPE 11 KV cable (cable entry from bottom ) and termination with heat shrinkable joining material etc. as reqd (Note :- Cost of end termination not included in this item)
A - a) Incoming 1 No 630 amp VCB
d) 1 No- Microprocessor based numerical relay with O/L, E/F and S/C protection.
e) 1 No. –set of dual core dual ratio 3 CTs 100/50/5/5 A of 15 VA burden and accuracy Class - 0.5 for metering and class 5 P10 for protection.
B) a) Outing -2 Nos 630 A VCB
C) 2 nos –Microprocessor based numerical relays with O/L ,EF and S/C protection.
D) 2 No. –set of dual core dual ratio 3 CTs 100/50/5/5 A of 15 VA burden and accuracy Class -1.0 for metering and class 5 P10 for protection.
E) Supplying installation testing & commissioning of power pack with 220 Volt A C input & 24 Volt DC continuous output suitable for closing /tripping /indication of 3 nos HT panel boards with 2 Nos 12 Volts each maintenance free ,batteries of 100 AH each charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of ammeter & Voltmeter i/c suitable capacity of ammeter & voltmeter i/c connections with 2.5 sq mm FRLS insulated copper conductor cable as reqd.
SITC of Cast Rasin Dry type 630 KVA 11/0.433 KV , 3 Phase 50 Hz, Dyn 11 vector group, cooper wound, class F insulation associated with winding temperature indicator/ ontroller actuated by means of resistance temperature detector embedded in LV winding ,indoor type transformer with approximately 4.5% impedance, tapping for off load operation on HV side in steps of +/-2.5 %, +/-5% & - 7.5% having cable end boxes on HV side suitable for 3X185 sq mm XLPE Cable of 11 KV grade and 1000 Amp bus trucking arrangement on LV side with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker for safety tripping, suitably mounted on M.S channel i/c supplying and grouting of suitable M.S channel with all accessories and confirming to IS 11171:1985 & as per per specification attached complete in all respects as reqd at site.
Supplying of unearthed / earthed armoured, aluminium conductor XLPE power cable of 11 KV grade confirming to IS 7098 (part II) amended up to date, in existing masonary opened up of the following size. (a) 3C x 185 sqmm
Supplying and laying of unearthed / earthed armoured, aluminium conductor XLPE power cable of 11 KV grade confirming to IS 7098 (part II) amended up to date, in existing masonary opened up of the following size. (a) 3C x 185 sqmm
Supplying and making indoor cable and termination with heat shrinkable joining kit complete with all accessories i/c lugs suitable for following sizes of 3.5 core XLPE Al. conductor cable of 11 KV grade as reqd.
3 X 185 sq. mm (57mm)
Supplying & Fixing of LT cubical panel board made from 2.0 mm thick CRCA MS sheet of not less than 1000 mm deep duly dust and vermin proof totally enclosed free floor standing i/c P/F 1000 ampere aluminium busbar for distribution system 3 phase, 4 wire 415 volt,50 c/s A.C. Supply i/c earth strips complete in all respects i/c painting with synthetic enamelled paint connection, interconnection so as to make the panel complete etc as reqd. i/c P/F of following electrical switch gears in the existing cubical panel board with suitable size of thimbles, ferrules etc. as reqd.(Size 5.2 Sq. Mtr. Approximately)
Incomer
a) 50 KA, 1000 A, Four Pole ACB EDO Type with O/L, S/C & G/F protection – 2 Nos.
c) LED Indicating light for incomer ACB’s
d) 6 A, SPMCB – 6 No.
Outgoing
a) 35/36KA, 630 A, TPN MCCB (thermo magnatec)– 3No.
b) 35/36KA, 200A,TPN MCCB (thermo magnatec)– 4 No.
c) 25 KA,160 A, TPN MCCB (thermo magnatec) – 3 No.
d) 25 KA, 100 A, TPN MCCB (thermo magnatec) – 2No.
e) 25 KA, 63 A, TPN MCCB (thermo magnatec) – 5 No.
Supplying, installation with support/suspension on wall/ ceiling including testing and commissioning of 1250 A 50KA for 1 sec Sandwich Type Busduct (for connection between Transformer & Main LT Panel) confirming to insulation class F and IP 54/55 for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints, elbow joints, expansion joints, bends, copper flexible for joints/termination (as per requirement ) and adopter box continuous earthing with 2 Nos aluminium strip of suitable size ( one on each side) including , G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. Busduct should be certified for Zone 5 seismic compliance and have insulation voltage of 1100 V, Imp-8 KV and tested as per IEC 61439-1&6 latest standards.
1251 A 50kA SC for 1 sec
L RISHIKANTA SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid