Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Being | |
| 2 | L2₹20.9 L+₹96,530 (4.85%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.3 L+₹4.4 L (22.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹28.4 L+₹8.5 L (43.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹29.9 L+₹10.0 L (50.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Jan 2024, 6:00 pmClosed
GE(AF) EM CHAKERI KANPUR
GE(AF)EM Chakeri
REPAIR AND RENEWAL TO EARTHING AND REPAIR AND MAINT OF LT PANEL OF AIR CONDITIONING PLANT AT TECHNICAL AREA AT AFS CHAKERI KANPUR
2023_MES_631814_1
8674/E8
Open Tender
Civil Works
Item Rate
180 days
AREA UNDER GE(AF) EM CHAKERI KANPUR
As per tender documents
9 documents required · 9 mandatory
₹500
GE(AF) EM CHAKERI
₹60,000
Yes
9 Mar 2024
8 Dec 2023
10 Jan 2024
9 Dec 2023
4 Jan 2024
22 Dec 2023
Amount
M&L for Electrical Main LT Panel,Design, fabrication, supply, installation, testing and commissioning of the Indoor type LT panel in replacement suitable to be mounted on the floor using MS channel frame work, with cable entry from bottom per drawing passed by GE with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 2 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/ compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door 1.5mm thick opening & closing mechanism and digital volt & Amp meter and all as per approved from CPRI comprising of following as under:-.
(b) 02 Nos for Condenser water pump 02 Nos 63 Amp., 25KA, 415V TP MCB with adjustable thermal settings, with starter suitable for condenser water motor rating AC 3 phase 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitable wired and interconnected with 4.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects. (c) 02 Nos for Chiller water pump (primary motor) 02 Nos 63 Amp., 25KA, 415V TP MCB with adjustable thermal settings, with starter suitable for Chiller water motor rating AC 3 phase 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitable wired and interconnected with 4.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects. (d) 02 Nos for Chiller water pump (secondery motor) 02 Nos 63 Amp., 25KA, 415V TP MCB with adjustable thermal settings, with starter suitable for Chiller water motor rating AC 3 phase 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitable wired and interconnected with 4.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects.
(e) 01 Nos for Cooling Tower 01 Nos 32Amp., 25KA, 415V TP MCCB with adjustable thermal settings, with starter suitable for cooling Tower motor rating, AC 3 duty 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc., complete in all respects. (f) 01 Nos for APFC panel. 1 No 160 Amp 36KA, 415V TP+NL MCCB with adjustable thermal settings.
M&L for Electrical Main LT Panel Design, fabrication, supply, installation, testing and commissioning of the following Indoor type LT panel in replacement suitable to be mounted on the floor using MS channel frame work, with cable entry from bottom as per drawing passed by GE with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 2 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/ compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism and digital volt & Amp meter and all as per approved from CPRI.comprising of following as under:-.
(b) 08 Nos for Chilled water pump 08 Nos 32 Amp., 25KA, 415V TP MCB with adjustable thermal with starter suitable for chilled water motor rating AC 3 duty 415V 50Hz 3 Phase motor. The starter shall be with single phase prevention & electronic timer, with sufficient auxiliary contacts for remote on/off indication lamp by metallic thermal over load relay of suitable size current rating, on/off push button suitable wired and inter connected with 4 sq mm single stranded PVC copper wire etc. complete in all respect (c) 03 Nos for Condenser water pump 03 Nos 32 Amp., 25KA, 415V TP MCB with adjustable thermal settings, with starter suitable for condenser water motor rating AC 3 phase 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitable wired and interconnected with 4.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects. (d) 02 Nos for AHU control panel 02 Nos 63 Amp., 36 KA, 415V TP MCB with adjustable thermal settings.
(e) 01 Nos for Cooling Tower 01 Nos 63Amp., 25KA, 415V TP MCB with adjustable thermal settings, with starter suitable for cooling Tower motor rating, AC 3 duty 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc., complete in all respects. (f) 01 Nos for APFC panel. 1 No 160 Amp 36KA, 415V TP+NL MCCB with adjustable thermal settings
Supply, installation, testing and commissioning of the following factory made Indoor type LT panel in replacement suitable to be mounted on the Floor as per site requirement using M.S channel frame work, with cable entry from bottom as per drawing passed by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 1.5 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, aluminum bus bars of 1.5 times capacity of main for three phases and neutral, bus bar insulators, heat shrinable PVC sleeves etc, with necessary interconnections as spectified and directed by Engr-in-charge including comprising of following switchgear and accessories complete in all respects:-.
Outgoing :(a) For Compresser-03 Nos MCCB Four ploe 63 Amps, 415Volts, 36KA breaking capacity with fixed adjustable thermal setting -3 No (i) Blower Motor 02 Nos 32 Amp., 25KA, 415V TP MCB with adjustable thermal settings, wire, etc, complete in all respects.(ii) 01 Nos for Cooling Tower 01 Nos 63Amp., 25KA, 415V TP MCB with adjustable thermal settings, with starter suitable for cooling Tower motor rating, AC 3 duty 415V, 50Hz.
Outgoing :(b) For condenser water pump-02 Nos (i) The star delta starter AC , 3 phase, 415 V suitable for condenser water pump motor of cap 10 HP, shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects.
Supply and fixing in replacement of Digital Microprocessor up controller for Vlrp V1 single compressor and fixing in LT control Panel mounted on AC Plant of Voltas model 5H80 of capacity 80TR having complete feature as per existing of cat part NO : ACEPUMPC020D of voltas make or equivalent in Blue Star/Soft Hard Automation Pvt Ltd and all as specifieed and directed by engineer-in-charge at site.
S&F in replacement MCB 40 Amps TP and breaking capacity 10 KA complete all as specified and directed.
S&F in replacement MCB 63 Amps TPN and breaking capacity 10 KA complete all as specified & directed.
S&F in replacement AC Control Power Contactor 3TF49 suitable for 100 TR compressor (110V-AC Coil Voltage) complete all as specified and directed.
S&F in replacement AC Control Power Contactor 3TF46 suitable for 50 TR compressor (110V-AC Coil Voltage) complete all as specified and directed.
S&F in replacement of power contractor MNX 32 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed. Make: L&T / ABB / Siemens / C&S
S&F in replacement of power contractor MNX 25 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed.Make: L&T / ABB / Siemens / C&S
S&F in replacement of power contractor MNX 18 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed.Make: L&T / ABB / Siemens / C&S
S&F in replacement of power contractor MNX 12 with NO NC axuilary contactor of model MNX A2 or equivalent model complete all as specified and directed.Make: L&T / ABB / Siemens / C&S
S&F in replacement of MCCB 800 Amps, TP+NL 50 KA, 415 volts 50 Hz including necessary connection for incoming/outgoing with lugs of suitable size complete all as specified and directed.Make: L&T / Legrand / CG / C&S / Schneider
All as per item no. 13 above but MCCB 200 Amps TP, 36 KA, 415V, 50 Hz
All as per item no. 13 but of 100 Amps TP 16 KA, 415 V, 50 Hz
All as per item no. 13 but of 160 Amps TP 16 KA, 415 V, 50 Hz.
All as per item no. 13 but of 125 Amps TP, 16 KA, 415 V, 50 Hz.
All as per item no. 13 but of 400 Amps TP, 25 KA, 415 V, 50 Hz.
All as per item no. 13 but of 63 Amps TP, 16 KA, 415 V, 50 Hz.
All as per item no. 13 but of 250 Amps TP, 25 KA, 415 V, 50 Hz.
S&F in replacement of kit kat fuse unit upto 100 Amps suitable for LT panel complete all as specified and directed.
S&F in replacement of 200 Amps connector suitable for LT panel complete all as specified and directed.
S&F in replacement of 100 Amps TPN isolator suitable for LT panel complete all as specified and directed.
S&F in replacement of electronc timer suitable for AC plant upto 100 TR complete all as specified and directed
S&F in replacement of single phase preventer VSP complete all as specified and directed. Make:- Minilec / L&T / Legrand / Siemens
S&F in replacement of ON/OFF Push switches complete all as specified and directed.
S&F in replacement of ammeter flush type 96X96 sqmm, 5A class 1 with suitable fixing arrangement and CT coil for easily fixing in existing LT panel including necessary wiring complete all as specified and as directed. Make:- Seimens / L&T / Legrand
S&F in replacement of voltmeter flush type 96X96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and as directed. Make:- Seimens / L&T / Legrand
S&F in replacement of over load relay range 36-60 complete all as specified and directed.
M&L for taking out old unserviceable cable & supply, laying & testing of XLPE insulated, screened PVC bedded, galvanised steel strip of wire armoured heavy duty electric power cable 1100 volts grade,with stranded aluminium conductor of size 06 sqmm 3½ complete all as Spd & directed
All as per Srl Item no. 30 above but of size 70 Sqmm 3½ core complete all as Spd & directed
All as per Srl Item no. 30 above but of size 50 Sqmm 3½ core complete all as specified and as directed.
All as per Srl Item no. 30 above but of size 25 Sqmm 3½ core complete all as specified and as directed.
All as per Srl Item no. 30 above but of size 16 Sqmm 3.5 core complete all as specified and as directed.
Supply and fix in replacement copper lugs 25 to 90 Sqmm complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminum conductor served with an inner sheathing of PVC tape overall PVC sheathed 4 sq. mm 3 core nominal cross section complete all as specified and directed by engg in charge.
M & L for earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI strip of size 32x6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel including excavation and earth work, GI pipe light grade 25mm/40 mm bore for protection of GI wire /strip from earth electrode to and inclunding the earth test point of gun metal or phosphorus bronze size of size 75 X 75 X 25mm drilled and screwed including, 3 Nos, 8mm dia 25mm long hexagonal head screw, supplying and laying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed.Note:- Earth strip up to 7.5 mtr shall be deemed to be included in quoted unit rate.
M&L for earth continuity conductor or main earthing lead GI strip 32x6mm. fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. all as directed by Engineer in Charge.
M&L in repair for fabrication of frame structure of size 4.5 X 2.4 m consisted of PVC W type4 pass eliminator with GI frame of size 1500 X 2400 X 190 MM thick louvers duly V shaped and velded with frame notch at both ends to portect spalishing of sprinkaled water on blowers and appling two coat of synthentic enamel blue shade paint over a coat of red oxied primer on exposed surfaces complete all as specified and directed.
M & L for Preparation of surface of MS/DI Pipe of 150 mm dia by amri paper/wire brush with taking out the rust/scrapped oil bound material from the surface including wash out by water and drying properly all as specified & directed by Engg-in- Charge.
All as per item no. 42 here in before but for 100 mm dia
All as per item no. 42 here in before but for 80 mm dia
All as per item no. 42 here in before but for 40 mm dia
M&L for painting the surface of DI/MS pipe of 150 mm dia of existing colour with DOCO paint by one coat with brush painting with all in sealed pack container & approved by Engg-in-Charge.Make of paint Asian,salimar,Nerolac or equivalent all as specified and directed by Eng-in-charge.
All as per item no. 46 here in before but for 100 mm dia
All as per item no. 47 here in before but for 80 mm dia
All as per item no. 47 here in before but for 40 mm dia
santosh electronics
S B ENTERPRISES
BRITE INDUSTRIES
m/s A.A brothers
JASPREET SINGH COOLING CORP.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .