Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 31 A AVANTIKA ENCLAVE SEC 2 ROHINI NORTH WEST DELHI DELHI 110083 | NORTH WEST DELHI | DELHI | 110083 | Admitted-Finance |
| 2 | Admitted-Finance 264 265 SATYAM TOWER COMMERCIAL COMPLEX PASCHIM VIHAR WEST DELHI DELHI 110063 UDYAM DL 11 0148375 | WEST DELHI | DELHI | 110063 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹85.0 L
EMD Value
₹1.7 L
Closing Date
7 Mar 2022, 11:00 amClosed
Chief Engineer
ESD CSIR Complex Pusa New Delhi
Operation and Annual Maintenance Contract of Fire Alarm Fire Fighting Talk Back and P A system installed at CSIR Hq Rafi Marg CSIR Complex Pusa and CSIR Scientist Apartments Maharani Bagh Ashram Chowk New Delhi
2022_CSIR_107543_1
11-6(29)/2022-Engg.
Open Tender
Electrical Works
Item Rate
365 days
CSIR HQ Buildings New Delhi
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
US
₹1.7 L
14 Mar 2022
26 Feb 2022
8 Mar 2022
28 Feb 2022
7 Mar 2022
28 Feb 2022
Amount
Sub-Head: I: Operation and Annual Maintenance Contract of FF, FA, Talk Back and PA system
SCHEDULE: A: CSIR Hq., Rafi Marg, New Delhi
Operation and Annual Maintenance Contract of Fire fighting, Fire hydrant, Automatic fire detection, Talk back and PA system. The scope of work including the deployment of manpower is as per annexure: I
SCHEDULE: B: CSIR Complex, PUSA New Delhi
Operation and Annual Maintenance Contract of Fire fighting, Fire hydrant, Automatic fire detection, Talk back and PA System. The scope of work including the deployment of manpower is as per annexure: I
SCHEDULE: C: CSIR Scientist Apartments, Maharani Bagh, Ashram Chowk New Delhi
Operation and Annual Maintenance Contract of Fire fighting and Fire hydrant System. The scope of work including the deployment of manpower is as per annexure: I
Sub-Head: II: Supply and Installation of Fire Fighting Equipment
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel fire red paints over primer coat etc complete as required
(a) 50 mm dia
(b) 80 mm dia
(c) 100 mm dia
(d) 150 mm dia
Service charges for Liasoning up work from the Delhi Fire Service (DFS) for obtaining NOC (excluding NOC fees which would be reimbursed against the original copy of bill) for operation of Fire fighting and Fire Alarm system. In case of descripancies pointed by the DFS the same have to comply/ executed at their requirement. (All the extra work which is not cover under AMC will be payable to the firm.)
Supplying, installation, testing and commissioning of Co2, 4.5 Kg capacity fire extinguishers including discharge horns / pipe and all accessories / parts etc complete in all respect.
Supplying, installation, testing and commissioning of Dry chemical powder type fire extinguishers of 6 Kg including discharge horns / pipe and all accessories / parts etc complete in all respect.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless Steel (Grade 304)
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Painting (one or more coats) on rain water, soil, waste, vent & fire pipes and fittings (i.e hydrant valves, NRV, landing valves & sluice valve) with synthetic enamel fire red paint of approved brand and manufacture and required (RED) colour on old work :
a) 100 mm diameter pipes
b) 150 mm diameter pipes
SUB-HEAD: III : Refilling of Fire Extinguishers
Refilling & repainting of Co2, 4.5 Kg capacity fire extinguishers including replacing damage discharge horns / pipe and all damages parts etc complete in all respect.
Refilling and repainting of Water CO2 of 9 litres capacity fire extinguishers including replacing damage discharge horn/ pipe and all damage parts etc complete in all respect.
Refilling and repainting of foam type fire extinguishers, portable type 9 litre capacity including replacing damage discharge horn/ pipe and all damage parts etc complete in all respect.
Refilling and Repainting of ABC type fire extinguishers of 1 kg capacity including replaing discharge horns and all damages parts, testing etc complete in all respect.
Refilling and repainting of CO2, 3 Kg capacity fire extinguishers including replacing damage discharge horn/ pipe and all damages parts etc complete in all respect.
Refilling & repainting of ABC 5/6 Kgs capacity fire extinguishers including replacing damage discharge horns / pipe and all damages parts etc complete in all respect.
ADP FIRE SYSTEMS
DIGITEK FIRE SAFETY PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .